Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Voyager™ 1452g Series Cordless Area-Imaging Scanner Quick Start Guide 1452-QS Rev (a) 11/14 Aller à www.honeywellaidc.com pour le français. Vai a www.honeywellaidc.com per l'italiano. Gehe zu www.honeywellaidc.com für Deutsch. Ir a www.honeywellaidc.com para español. Para Português, acesse www.honeywellaidc.com.br. Перейти на русскоязычный сайт www.honeywellaidc.com. Pro češtinu jdi na www.honeywellaidc.com. Pre slovenčinu choď na www.honeywellaidc.com 日本語: www.honeywellaidc.comをご覧ください。 中文(简体),请访问:www.honeywellaidc.com。 中文(繁体),请访问: www.honeywellaidc.com。 한글 www.honeywellaidc.com로 이동합니다. P relim in ar y D r af t 11/1 0/ 14 Note: Refer to your user’s guide for information about cleaning your device. For localized language versions of this document, go to www.honeywellaidc.com. Getting Started Turn off the computer’s power before connecting the base, then power up the computer once the base is fully connected. When the base is connected and powered up, put the scanner in the base to establish a link. The green LED on the base flashes to indicate the scanner’s battery is charging. Power Supply Assembly (if included) Note: The power supply must be ordered separately, if needed. USB Connection: Keyboard Wedge Connection: RS232 Serial Port Connection: RS485 Connection: Reading Techniques The view finder projects an aiming beam that should be centered over the bar code, but it can be positioned in any direction for a good read. Hold the scanner over the bar code, pull the trigger, and center the aiming beam on the bar code. The aiming beam is smaller when the scanner is closer to the code and larger when it is farther from the code. Hold the scanner close to smaller bar codes, and farther away from large bar codes to get a proper read. If the bar code is highly reflective (e.g., laminated), you may need to tilt the scanner at an angle so the bar code can be scanned. Note: If the scanner razzes when scanning a bar code, the link has not been established. If the scanner beeps once, the link has been established. Standard Product Defaults The following bar code resets all standard product default settings. Note: PDF and 2D bar codes can only be read by Voyager model 1452g2D and cannot be read by model 1452g1D. Standard Product Defaults RS485 Interface The RS485 interface defaults to port 5B. If you have an IBM POS terminal using port 9B, scan the appropriate code below to program the terminal, then power cycle the cash register. Note: For additional RS485 interface selections, see the User’s Guide for your product at our website, www.honeywellaidc.com. USB Serial Scan the following code to program the scanner to emulate a regular RS232-based COM Port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Honeywell website (www.honeywellaidc.com). The driver will use the next available COM Port number. Apple® Macintosh computers recognize the scanner as a USB CDC class device and automatically use a class driver. Note: No extra configuration (e.g., baud rate) is necessary. IBM Port 9B HHBCR-1 Interface IBM Port 9B HHBCR-2 Interface USB Serial USB PC Keyboard Scan the following code to program the scanner for a USB PC Keyboard. Keyboard Country Scan the Program Keyboard Country bar code below, then scan the numeric bar code(s) from page 2, then the Save bar code to program the keyboard for your country. As a general rule, the following characters are not supported by the scanner for countries other than the United States: @ | $ # { } [ ] = / ‘ \ < > ~ Note: For a complete list of country codes, see the User’s Guide for your product at our website, www.honeywellaidc.com. Country CodeScanCountry CodeScan Belgium1Italy5 Denmark8Norway9 Finland2Spain10 France3Switzerland6 Germany/Austria4USA (Default)0 Great Britain7 USB PC Keyboard Program Keyboard Country Save Locked Link If you link a scanner to a base using the Locked Link Mode, other scanners are blocked from being linked if they are inadvertently placed into the base. If you do place a different scanner into the base, it will charge the scanner, but the scanner will not be linked. To use a different scanner, you need to unlink the original scanner by scanning the Unlink Scanner bar code. Override Locked Scanner If you need to replace a broken or lost scanner that is linked to a base, scan the Override Locked Scanner bar code with a new scanner, and place that scanner in the base. The locked link will be overridden; the broken or lost scanner’s link with the base will be removed, and the new scanner will be linked. Unlinking the Scanner If the base has a scanner linked to it, that scanner must be unlinked before a new scanner can be linked. Once the previous scanner is unlinked, it will no longer communicate with the base. Scan the Unlink Scanner bar code to unlink a scanner. Locked Link Mode (Single Scanner) Override Locked Scanner Unlink Scanner Prel im in ar y Dr a ft 1 1/10/14 Trigger The following bar codes will allow you to use the scanner in Manual Trigger - Normal Mode (need to press the trigger to read) or Presentation mode (the scanner is activated when it “sees” a bar code). Suffix If you want a carriage return after the bar code, scan the Add CR Suffix bar code. To add a tab after the bar code, scan the Add Tab Suffix bar code. Otherwise, scan the Remove Suffix bar code to remove the suffixes. Manual Trigger - Normal (Default) Presentation Mode Add CR Suffix Remove Suffix Add Tab Suffix Add Code ID Prefix to all Symbologies Scan the following bar code if you wish to add a Code ID prefix to all symbologies at once. Note: For a complete list of Code IDs, see the User’s Guide for your product at our website, www.honeywellaidc.com. Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in your User’s Guide. When the scanner is in keyboard wedge mode, the…
Text truncated - open the document above for the full version.
Honeywell International Inc Date: 2014-1 2-23 Federal Communications Commission Authorization and Evaluation Division FCC ID: HD5-1452G1 ATTESTATION FCC ID: HD5-1452G1 Product: Barcode Scanner Model: 1452g We don't provide any controls or software to allow operation outside the USA frequency band when we sell this product in USA. Sincerely, __________________ Michael Robinson / Product Compliance Honeywell International Inc
RF_160, Issue 02 Honeywell International Inc Declaration of Authorization We Name: Honeywell International Inc Address: 9680 old Bailes Rd Fort Mill SC29707 City: ......... South Carolina ................................................................ Country:......... United States ............................................................................ Declare that: Name Representative of agent: Gene Chang (1) Agent Company name: QuieTek Corp. Address: Fl.2, No.345, Xin-hu 2 nd Rd., Nei-hu District City: Taipei Country Taiwan is authorized to apply for Certification of the following product(s): Product description: Barcode Scanner Type designation: 1452g on our behalf. Date: 2014-12-23 City: South Carolina Name: Michael Robinson (2) Function: Product Compliance Signature: Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.
Honeywell International Inc Date: 2014-12-23 Federal Communications Commission Authorization and Evaluation Division FCC ID: HD5-1452G1 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Confidentiality Request 1 Schematics 2 Block Diagram 3 Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. Sincerely, _________________________ Michael Robinson / Product Compliance Honeywell International Inc
Honeywell International Inc 9680 old Bailes Rd Fort Mill SC29707 South Carolina United States Attestation for FCC Declaration of Conformity FCC ID: HD5-1452G1 Date: 2015/01/04 Please be notified that we, the undersigned, Honeywell International Inc declares that the product which bears the above FCC ID is also compliant with the FCC requirements for DOC. The test report number supporting the DOC is 14B0410R-ITUSP01V02 Testing in regards to this report was done by QuieTek Corp., located at No.5-22, Rueishu Keng, Rueiping Tsuen, Linkou Shiang, Taipei County 244, Taiwan, which has been accredited in accordance to all of the requirements of 47CFR 2.948 (d) and (e) of the FCC rules and KDB349827. Sincerely __________________ Michael Robinson / Product Compliance Honeywell International Inc
EUT Photograph (1) EUT Photo (2) EUT Photo (3) EUT Photo (4) EUT Photo (5) EUT Photo
EUT Photograph (1) EUT Photo (2) EUT Photo (3) EUT Photo
RF Exposure Evaluation Declaration Product Name : Barcode Scanner Model No. : 1452g FCC ID : H5D-1452G1 IC : 1693B-1452G1 Applicant : Honeywell International Inc Address : 9680 old Bailes Rd Fort Mill SC29707 South Carolina United States Date of Receipt : Nov. 17, 2014 Issued Date : Dec. 31, 2014 Report No. : 14B0410R-RF-US-P20V01 Report Version : V3.0 The test results relate only to the samples tested. The test results shown in the test report are traceable to the national/international standard through the calibration of the equipment and evaluated measurement uncertainty herein. This report must not be used to claim product endorsement by TAF or any agency of the government. The test report shall not be reproduced without the written approval of QuieTek Corporation. Report No: 14B0410R-RF-US-P20V01 Page: 2 of 6 Test Report Certification Issued Date : Dec. 31, 2014 Report No. : 14B0410R-RF-US-P20V01 Product Name : Barcode Scanner Applicant : Honeywell International Inc Address : 9680 old Bailes Rd Fort Mill SC29707 South Carolina United States Manufacturer : 1. Honeywell International Inc 2. Metro(Suzhou)Technologies Co.,Ltd Address : 1. 9680 old Bailes Rd Fort Mill SC29707 South Carolina United States 2. No.221 Xinghai street China-Singapore Suzhou Industrial Park Model No. : 1452g FCC ID : H5D-1452G1 IC : 1693B-1452G1 EUT Voltage : DC: 5.0 V Brand Name : Honeywell Applicable Standard : KDB 447498D01V05V02 FCC Part1.1310(b) RSS-102: Issue 4, March, 2010 Test Result : Complied Performed Location : Suzhou EMC Laboratory No.99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., Suzhou, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 FCC Registration Number: 800392; IC Lab Code: 4075B Documented By : Reviewed By : Approved By : Report No: 14B0410R-RF-US-P20V01 Page: 3 of 6 Laboratory Information We, QuieTek Corporation, are an independent EMC and safety consultancy that was established the whole facility in our laboratories. The test facility has been accredited/accepted(audited or listed) by the following related bodies in compliance with ISO 17025, EN 45001 and specified testing scope: The related certificate for our laboratories about the test site and management system can be downloaded from QuieTek Corporation’s Web Site :http://www.quietek.com/tw/ctg/cts/accreditations.htm The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site : http://www.quietek.com/ If you have any comments, Please don’t hesitate to contact us. Our contact information is as below: HsinChu Testing Laboratory : No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C. TEL:+886-3-592-8858 / FAX:+886-3-592-8859 E-Mail : [email protected] LinKou Testing Laboratory : No.5-22, Ruishukeng, Linkou Dist., New Taipei City 24451, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected] Suzhou Testing Laboratory : No.99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., SuZhou, China TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : [email protected] Taiwan R.O.C. :BSMI, NCC, TAF Germany :TUV Rheinland Norway :Nemko, DNV USA :FCC Japan :VCCI China :CNAS Report No: 14B0410R-RF-US-P20V01 Page: 4 of 6 History of This Test Report REPORT NO. VERSION DESCRIPTION ISSUED DATE 14B0410R-RF-US-P20V01 V1.0 Initial Issued Report Dec. 26, 2014 14B0410R-RF-US-P20V01 V2.0 Modified FCC ID and IC ID Dec. 26, 2014 14B0410R-RF-US-P20V01 V3.0 Modified applicant and manufacturer Dec. 31, 2014 Report No: 14B0410R-RF-US-P20V01 Page: 5 of 6 1. RF Exposure Evaluation 1.1. Limits According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm2) Average Time (Minutes) (A) Limits for Occupational/ Control Exposures 300-1500 -- -- F/300 6 1500-100,000 -- -- 5 6 (B) Limits for General Population/ Uncontrolled Exposures 300-1500 -- -- F/1500 6 1500-100,000 -- -- 1 30 F= Frequency in MHz Friis Formula Friis transmission formula: Pd = (Pout*G)/(4*pi*r2) Where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Report No: 14B0410R-RF-US-P20V01 Page: 6 of 6 1.2. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. The temperature and related humidity: 18°Cand 78% RH. 1.3. Test Result of RF Exposure Evaluation Product : Barcode Scanner Test Item : RF Exposure Evaluation Test Site : AC-6 z Antenna Gain: Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.8dBi and 2 in logarithm scale. z Output Power into Antenna & RF Exposure Evaluation Distance: Frequency Band (MHz) Maximum Output Power to Antenna (mW) Power Density at R = 20 cm (mW/cm2) 2402- 2480 MHz 3.6813 0.001108 Note: The power density Pd (4th column) at a distance of 20 cm calculated from the Friis transmission formula is far below the limit of 1 mW/cm2. The End
For FCC Standalone SAR test exclusion considerations FCC ID: H5D-1452G1 Tunable Range F(GHz) Low F(GHz) High 2.402 2.480 According to KDB 447498 D01 General RF Exposure Guidance v05 4.3.1 Standalone SAR test exclusion considerations The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR Note: when the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. Based on the Maximum measured transmitter power: Pout Conducted (dBm) Maximum Antenna Gain (dBi) Pout EIRP (mW) 5.66 1.8 5.57 Maximum TX Power is 3.68 mW Conducted and 5.57 mW EIRP [(5.57 mW/5 mm)* √2.480(GHz)]=1.75 <3.0 Conclusion: Bluetooth SAR was not required.
Test Report FCC Part15 Subpart C Product Name : Barcode Scanner Model No. : 1452g FCC ID : H5D-1452G1 IC : 1693B-1452G1 Applicant : Honeywell International Inc Address : 9680 old Bailes Rd Fort Mill SC29707 South Carolina United States Date of Receipt : Nov. 17, 2014 Test Date : Nov. 17, 2014~ Dec. 14, 2014 Issued Date : Dec. 31, 2014 Report No. : 14B0410R-RF-US-P06V01 Report Version : V 3.0 The test results relate only to the samples tested. The test results shown in the test report are traceable to the national/international standard through the calibration of the equipment and evaluated measurement uncertainty herein. This report must not be used to claim product endorsement by TAF or any agency of the government. The test report shall not be reproduced without the written approval of QuieTek Corporation. Report No.: 14B0410R-RF-US-P06V01 Page: 2 of 111 Test Report Certification Issued Date : Dec. 31, 2014 Report No. : 14B0410R-RF-US-P06V01 Product Name : Barcode Scanner Applicant : Honeywell International Inc Address : 9680 old Bailes Rd Fort Mill SC29707 South Carolina United States Manufacturer : 1. Honeywell International Inc 2. Metro(Suzhou)Technologies Co.,Ltd Address : 1. 9680 old Bailes Rd Fort Mill SC29707 South Carolina United States 2. No.221 Xinghai street China-Singapore Suzhou Industrial Park Model No. : 1452g FCC ID : H5D-1452G1 IC : 1693B-1452G1 EUT Voltage : DC: 5.0 V Trade Name : Honeywell Applicable Standard : FCC CFR Title 47 Part 15 Subpart C: 2014 ANSI C63.10: 2009 RSS-Gen (Issue 4), November 2014 RSS-210 (Issue 8), December 2010 Test Result : Complied Performed Location : Suzhou EMC Laboratory No.99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., Suzhou, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 FCC Registration Number: 800392; IC Lab Code: 4075B Documented By : Reviewed By : Approved By : Report No.: 14B0410R-RF-US-P06V01 Page: 3 of 111 Laboratory Information We, QuieTek Corporation, are an independent EMC and safety consultancy that was established the whole facility in our laboratories. The test facility has been accredited/accepted(audited or listed) by the following related bodies in compliance with ISO 17025, EN 45001 and specified testing scope: The related certificate for our laboratories about the test site and management system can be downloaded from QuieTek Corporation’s Web Site :http://www.quietek.com/tw/ctg/cts/accreditations.htm The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site : http://www.quietek.com/ If you have any comments, Please don’t hesitate to contact us. Our contact information is as below: HsinChu Testing Laboratory : No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C. TEL:+886-3-592-8858 / FAX:+886-3-592-8859 E-Mail : [email protected] LinKou Testing Laboratory : No.5-22, Ruishukeng, Linkou Dist., New Taipei City 24451, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected] Suzhou Testing Laboratory : No.99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., SuZhou, China TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : [email protected] Taiwan R.O.C. :BSMI, NCC, TAF Germany :TUV Rheinland Norway :Nemko, DNV USA :FCC Japan :VCCI China :CNAS Report No.: 14B0410R-RF-US-P06V01 Page: 4 of 111 TABLE OF CONTENTS Description Page 1. General Information.................................................................................................... 8 1.1. EUT Description ......................................................................................................... 8 1.2. Mode of Operation ................................................................................................... 10 1.3. Tested System Details .............................................................................................. 11 1.4. Configuration of Tested System ............................................................................... 12 1.5. EUT Exercise Software ............................................................................................ 13 2. Technical Test ........................................................................................................... 14 2.1. Summary of Test Result ........................................................................................... 14 2.2. Test Environment ..................................................................................................... 15 3. Conducted Emission ................................................................................................ 16 3.1. Test Equipment ........................................................................................................ 16 3.2. Test Setup ................................................................................................................ 16 3.3. Limit .......................................................................................................................... 17 3.4. Test Procedure ......................................................................................................... 17 3.5. Uncertainty ............................................................................................................... 17 3.6. Test Result ............................................................................................................... 18 4. Radiated Emission ................................................................................................... 20 4.1. Test Equipment ........................................................................................................ 20 4.2. Test Setup ................................................................................................................ 21 4.3. Limit .......................................................................................................................... 22 4.4. Test …
Text truncated - open the document above for the full version.
Test Setup Photograph for Part 15.247 Description: Radiated Emission Test Setup for Below 30MHz Description: Radiated Emission Test Setup for Below 1GHz Description: Radiated Emission Test Setup for 1~18GHz Description: Radiated Emission Test Setup for Above 18GHz
No.99 Hongye RD.Suzhou Industrial Park · Suzhou · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.68 mW |
A rugged accessory for the Honeywell CT47 mobile computer which enables HF and UHF reading. Reader is supplied from mobile computer CT47.
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterA rugged accessory for the Honeywell CT47 mobile computer which enables HF and UHF reading. Reader is supplied from mobile computer CT47.
Equipment Class
DTS - Digital Transmission SystemBarcode Scanner
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterMobile Computer
Equipment Class
CBE - Citizens Band End User DevicesBarcode Scanner
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter