FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Honeywell International Inc/
  3. HD5-CX85WL

HD5-CX85WLWireless Charge Rack

Honeywell International Inc
Wireless Charge Rack - FCC ID HD5-CX85WL - Honeywell International Inc
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jun 07, 2021
Application Purpose
Original Equipment
Date of Application
Jun 03, 2021
Equipment Note
Wireless Charge Rack
Frequency Range
0.12000000 - 0.30000000
Company
Honeywell International Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CN85-WL-6DESK Wireless Charge Rack, Vertical Quick Start Guide CN85-WL-6DESK-EN-QS-1 (a prelim 1) 3/21   Preliminary Draft, Not for Release, For Review Purposes Only Preliminary Draft, Not for Release, For Review Purposes Only 1 Agency Model CN85-WL-6DESK Out of the Box Make sure that your shipping box contains these items: • DIAD 6, Charge Rack (CN85-WL-6DESK) •Power Supply and Power Cable •Product Documentation If you ordered accessories for your device, verify that they are also included with the order. Be sure to keep the original packaging in case you need to return the device for service. Preliminary Draft, Not for Release, For Review Purposes Only Preliminary Draft, Not for Release, For Review Purposes Only 2 Charge Rack Features Power Connector Charge Bay, Qty. 6 Preliminary Draft, Not for Release, For Review Purposes Only Preliminary Draft, Not for Release, For Review Purposes Only 3 Back Plate Preliminary Draft, Not for Release, For Review Purposes Only Preliminary Draft, Not for Release, For Review Purposes Only 4 Connect Power The Charge Rack ships with a 12VDC, 8.5A power supply manufactured for Honeywell International Inc. 1.Connect the power cord to the power supply. 2.Connect the power supply to the Charge Rack. For connector location, see Charge Rack Features on page 2. 3.Connect the power cord to grounded power source (electrical outlet). We recommend the use of Honeywell accessories and power adapters. Use of any non-Honeywell accessories or power adapters may cause damage not covered by the warranty. Nous recommandons d’utiliser des accessoires et des adaptateurs secteur de marque Honeywell. L’utilisation de tout accessoire ou adaptateur secteur d’une autre marque est susceptible de provoquer des dommages non couverts par la garantie. Preliminary Draft, Not for Release, For Review Purposes Only Preliminary Draft, Not for Release, For Review Purposes Only 5 Charge Mobile Computer After installing the battery in the CN85, insert the computer into one of the six charging bays. Ensure all components are dry prior to mating the computers and batteries with peripheral devices. Mating wet components may cause damage not covered by the warranty. Assurez-vous que tous les composants sont secs avant de raccorder les ordinateurs et les batteries à des périphériques. L’insertion de composants humides risque de provoquer des dommages non couverts par la garantie. Preliminary Draft, Not for Release, For Review Purposes Only Preliminary Draft, Not for Release, For Review Purposes Only 6 Support To search our knowledge base for a solution or log into the Technical Support Portal and report a problem, go to www.hsmcontactsupport.com. Documentation Product documentation is available at www.honeywellaidc.com. Limited Warranty For warranty information, go to www.honeywellaidc.com and click Resources > Product Warranty. Patents For patent information, see www.hsmpats.com. Trademarks Android is a trademark of Google LLC. Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII. HII shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. HII disclaims all responsibility for the selection and use of software and/or hardware to achieve intended results. Preliminary Draft, Not for Release, For Review Purposes Only Preliminary Draft, Not for Release, For Review Purposes Only 7 This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of HII. Copyright © 2021 Honeywell International Inc. All rights reserved. Preliminary Draft, Not for Release, For Review Purposes Only Preliminary Draft, Not for Release, For Review Purposes Only Agency Information USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. ·If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Canadian Compliance This Class B digital apparatus complies with Canadian ICES-003. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Conformité à la règlementation canadienne Cet appareil numérique de la Classe B …

Text truncated - open the document above for the full version.

Cover Letter(s)

Safety and Productivity Solutions 9680 Old Bailes Road Fort Mill, SC 29707 USA www.honeywell.com www.honeywellaidc.com RF_160, Issue 04 Declaration of Authorization We Name: < HONEYWELL INTERNATIONAL INC > Address: 9680 Old Bailes Rd, Fort Mill, SC 29707-7539, USA . City:  Fort Mill . Country:  USA . Declare that: Name Representative of agent: ...Rachel Hua........... (1) Agent Company name:  DEKRA Testing and Certification (Suzhou) Co., Ltd.. Address:  No.99 Hongye RD.Suzhou Industrial Park, Suzhou China .. City:  Suzhou .. Country  China . is authorized to apply for Certification of the following product(s): Product description:  Wireless Charge Rack . Type designation:  CN85-WL-6DESK . Trademark:  Honeywell . Validity/ expiry date on our behalf. Date: 2021/03/31.. City:  Fort Mill .. Name:  Mandana Salahshour .. (2) Function: ......Global Regulatory Compliance Manager......................... Signature: . Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

FCC, Request for non-disclosure Date: 21-Nov-2018 RF_501, Issue 8 Page 1 of 1 Company Name: HONEYWELL INTERNATIONAL INC Address: 9680 Old Bailes Rd, Fort Mill, SC 29707-7539, USA City: Fort Mill Country: USA To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: HD5-CX85WL Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Date: 2021/03/31 Name and signature of applicant: Mandana Salahshour Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should stated in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period

External Photos

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-External Photo Page 1 / 8 External Photographs (1) EUT Photo (2) EUT Photo DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-External Photo Page 2 / 8 (3) EUT Photo (4) EUT Photo DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-External Photo Page 3 / 8 (5) EUT Photo (6) EUT Photo DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-External Photo Page 4 / 8 (7) EUT Photo (8) EUT Photo DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-External Photo Page 5 / 8 (9) Test Accessories Photo – client devices (10) Test Accessories Photo – client devices DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-External Photo Page 6 / 8 (9) Test Accessories Photo – client devices (10) Test Accessories Photo – client devices DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-External Photo Page 7 / 8 (9) Test Accessories Photo – client devices (10) Test Accessories Photo – client devices DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-External Photo Page 8 / 8 (11) Test Accessories Photo – client devices (12) Test Accessories Photo – client devices

ID Label/Location Info

BAdd one label for shippingDec.26/18 2018-6185 CUpdate Certification logosJul.23/19 2019-4099 C THREE Wireless Charge Rack/充电基座/充電基座 L-6DESK L L

Internal Photos

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-Internal Photo Page 1 / 5 Internal Photographs (1) EUT Photo (2) EUT Photo DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-Internal Photo Page 2 / 5 (3) EUT Photo (4) EUT Photo DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-Internal Photo Page 3 / 5 (5) EUT Photo (6) EUT Photo DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-Internal Photo Page 4 / 5 (7) EUT Photo (8) EUT Photo DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-Internal Photo Page 5 / 5 (9) EUT Photo (10) EUT Photo

RF Exposure Info

RF Exposure Evaluation Declaration Product Name : Wireless Charge Rack Model No. : CN85-WL-6DESK FCC ID : HD5-CX85WL Applicant : HONEYWELL INTERNATIONAL INC Honeywell Safety and Productivity Solutions Address : 9680 OLD BAILES RD FORT MILL SC 29707-7539, USA Date of Receipt : Jan. 26, 2021 Test Date : Jan. 27, 2021 ~ Jun. 04, 2021 Issued Date : Jun. 04, 2021 Report No. : 2110870R-RF-US-P20V01 Report Version : V1.0 The test results presented in this report relate only to the object tested. The measurement result is considered in conformance with the requirement if it is within the prescribed limit, It is not necessary to account the uncertainty associated with the measurement result. This report shall not be reproduced, except in full, without the written approval of DEKRA Testing and Certification (Suzhou) Co., Ltd. This report is not used for social proof in China (or Mainland China) market. Report No: 2110870R-RF-US-P20V01 Page: 2 of 19 Te s t R e p o r t C e r t i f i c a t i o n Issued Date: Jun. 04, 2021 Report No.: 2110870R-RF-US-P20V01 Product Name : Wireless Charge Rack Applicant : HONEYWELL INTERNATIONAL INC Honeywell Safety and Productivity Solutions Address : 9680 OLD BAILES RD FORT MILL SC 29707-7539, USA Manufacturer : 1.HONEYWELL INTERNATIONAL INC Honeywell Safety and Productivity Solutions 2.Metro(Suzhou)Technologies Co.,Ltd Address : 1.9680 OLD BAILES RD FORT MILL SC 29707-7539, USA 2.No.221 Xinghai street China-Singapore Suzhou Industrial Park Model No. : CN85-WL-6DESK FCC ID : HD5-CX85WL Brand Name : Honeywell EUT Voltage : AC 120V/60Hz Applicable Standard : KDB 680106 D01 RF Exposure Wireless Charging App v03r01 Test Result : Complied Performed Location : DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 FCC Designation Number: CN1199 Documented By : (Project Engineer: Scott Shen) Approved By : (Supervisor: Jack Zhang) Report No: 2110870R-RF-US-P20V01 Page: 3 of 19 TABLE OF CONTENTS Description Page 1. General Information .................................................................................................... 5 1.1. EUT Description ........................................................................................... 5 1.2. Antenna information ..................................................................................... 6 1.3. Mode of Operation ........................................................................................ 7 1.4. Tested System Details .................................................................................. 8 1.5. Configuration of Tested System .................................................................... 9 1.6. EUT Exercise Software............................................................................... 10 2. Technical Test ........................................................................................................... 11 2.1. Test Environment ........................................................................................ 11 3. Electric Field Strength / Magnetic Field Strength ...................................................... 12 3.1. Test Equipment ........................................................................................... 12 3.2. Test Setup................................................................................................... 13 3.3. Test Configuration ....................................................................................... 14 3.4. Limit ............................................................................................................ 15 3.5. Test Procedure ........................................................................................... 15 3.6. Uncertainty ................................................................................................. 16 3.7. Test Result .................................................................................................. 17 Report No: 2110870R-RF-US-P20V01 Page: 4 of 19 History of This Test Report REPORT NO. VERSION DESCRIPTION ISSUED DATE 2110870R-RF-US-P20V01 V1.0 Initial Issued Report Jun. 04, 2021 Report No: 2110870R-RF-US-P20V01 Page: 5 of 19 1. General Information 1.1. EUT Description Product Name Wireless Charge Rack Model No. CN85-WL-6DESK S/N 21012B2C08 Hardware Version Rev01 Working Voltage AC 120V/60Hz Frequency Range 120 kHz ~ 300 kHz Type of Modulation ASK Report No: 2110870R-RF-US-P20V01 Page: 6 of 19 1.2. Antenna information Model No. N/A Antenna manufacturer N/A Antenna Delivery 1*TX+1*RX 2*TX+2*RX 3*TX+3*RX Antenna technology SISO MIMO Basic CDD Sectorized Beam-forming Antenna Type External Dipole Sectorized Internal PIFA PCB Ceramic Chip Antenna Loop antenna Type F antenna Report No: 2110870R-RF-US-P20V01 Page: 7 of 19 1.3. Mode of Operation DEKRA has verified the construction and function in typical operation. All the test modes were carried out with the EUT in normal operation, which was shown in this test report and defined as: Test Mode Mode 1: Transmit Note: 1. Regards to the frequency band operation: the lowest、middle and highest frequency of channel were selected to perform the test, then shown on this report. 2. For portable device, radiated spurious emission was verified over X, Y, Z Axis, and shown the worst case on this report. Report No: 2110870R-RF-US-P20V01 Page: 8 of 19 1.4. Tested System Details The types for all equipment, plus descriptions of all cables used in the tested system (including inserted cards) are: Product Manufacturer Model No. Serial No. Power Cord 1 N/A N/A N/A N/A N/A Report No: 2110870R-RF-US-P20V01 Page: 9 of 19 1.5. Configuration of Tested System Test setup Diagram- Radiated Emission Report No: 2110870R-RF-US-P20V01 Page: 10 of 19 1.6. EUT Exercise Software 1 Setup the EUT and simulators as shown on above. 2 Turn on the power of equipment. 3 Start to continue transmit. Report No: 21108…

Text truncated - open the document above for the full version.

Test Report

Test Report FCC Part15 Subpart C Product Name : Wireless Charge Rack Model No. : CN85-WL-6DESK FCC ID : HD5-CX85WL Applicant : HONEYWELL INTERNATIONAL INC Honeywell Safety and Productivity Solutions Address : 9680 OLD BAILES RD FORT MILL SC 29707-7539, USA Date of Receipt : Jan. 26, 2021 Test Date : Jan. 27, 2021 ~ Mar. 23, 2021 Issued Date : Apr. 27, 2021 Report No. : 2110870R-RF-US-P06V05 Report Version : V1.0 The test results presented in this report relate only to the object tested. The measurement result is considered in conformance with the requirement if it is within the prescribed limit, It is not necessary to account the uncertainty associated with the measurement result. This report shall not be reproduced, except in full, without the written approval of DEKRA Testing and Certification (Suzhou) Co., Ltd. This report is not used for social proof in China (or Mainland China) market. Report No.: 2110870R-RF-US-P06V05 Page: 2 of 28 Te s t R e p o r t C e r t i f i c a t i o n Issued Date : Apr. 27, 2021 Report No. : 2110870R-RF-US-P06V05 Product Name : Wireless Charge Rack Applicant : HONEYWELL INTERNATIONAL INC Honeywell Safety and Productivity Solutions Address : 9680 OLD BAILES RD FORT MILL SC 29707-7539, USA Manufacturer : 1.HONEYWELL INTERNATIONAL INC Honeywell Safety and Productivity Solutions 2.Metro(Suzhou)Technologies Co.,Ltd Address : 1.9680 OLD BAILES RD FORT MILL SC 29707-7539, USA 2.No.221 Xinghai street China-Singapore Suzhou Industrial Park Model No. : CN85-WL-6DESK FCC ID : HD5-CX85WL EUT Voltage : AC 120V/60Hz Brand Name : Honeywell Applicable Standard : FCC CFR Title 47 Part 15 Subpart C; ANSI C63.10: 2013 Test Result : Complied Performed Location : DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 FCC Designation Number: CN1199 Documented By : (Project Engineer: Scott Shen) Approved By : (Supervisor: Jack Zhang) Report No.: 2110870R-RF-US-P06V05 Page: 3 of 28 TABLE OF CONTENTS Description Page 1. General Information................................................................................................................. 5 1.1. EUT Description ...................................................................................................................... 5 1.2. Antenna information ................................................................................................................ 6 1.3. Mode of Operation .................................................................................................................. 7 1.4. Tested System Details ............................................................................................................. 8 1.5. Configuration of Tested System ............................................................................................... 9 1.6. EUT Exercise Software ......................................................................................................... 10 2. Technical Test ......................................................................................................................... 11 2.1. Summary of Test Result ......................................................................................................... 11 2.2. Test Environment ................................................................................................................... 11 3. Conducted Emission ............................................................................................................. 12 3.1. Test Equipment ..................................................................................................................... 12 3.2. Test Setup ............................................................................................................................. 12 3.3. Limit ...................................................................................................................................... 13 3.4. Test Procedure ...................................................................................................................... 13 3.5. Uncertainty ............................................................................................................................ 13 3.6. Test Result ............................................................................................................................ 14 4. Radiated Emission ................................................................................................................ 16 4.1. Test Equipment ..................................................................................................................... 16 4.2. Test Setup ............................................................................................................................. 17 4.3. Limit ...................................................................................................................................... 18 4.4. Test Procedure ...................................................................................................................... 18 4.5. Uncertainty ............................................................................................................................ 19 4.6. Test Result ............................................................................................................................ 20 5. 20dB Occupied Bandwidth .................................................................................................... 24 5.1. Test Equipment ..................................................................................................................... 24 5.2. Test Setup ............................................................................................................................. 25 5.3. Limit ......................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-US-Test Photo Page 1 / 6 FCC Test Photographs Description: Radiated emission(Below 30MHz) Description: Radiated emission(Above 30MHz) DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-US-Test Photo Page 2 / 6 Description: AC Power Line Conducted Emission Description: RF Exposure Setup – One device Loaded 3kHz~100kHz DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-US-Test Photo Page 3 / 6 Description: RF Exposure Setup –One device Loaded Above 100kHz Description: RF Exposure Setup –Two devices Loaded 3kHz~100kHz DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-US-Test Photo Page 4 / 6 Description: RF Exposure Setup –Two devices Loaded Above 100kHz Description: RF Exposure Setup – Fully Loaded 3kHz~100kHz DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-US-Test Photo Page 5 / 6 Description: RF Exposure Setup – Fully Loaded Above 100kHz Description: RF Exposure Setup – Test Probe 1Hz ~ 400kHz DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 2110870R-RF-US-Test Photo Page 6 / 6 Description: RF Exposure Setup – Test Probe 100kHz ~ 3GHz

Contact Information

Applicant

Cindy Jiang(Global Regulatory Compliance Manager)
[email protected]+86(512)82258162Fax: +86(512)62571517

Technical Contact

DEKRA Testing and Certification (Suzhou) Co., Ltd.Janet Xu
[email protected]0512-62515088-5113

No.99 Hongye RD.Suzhou Industrial Park, · China

Non-Technical Contact

DEKRA Testing and Certification (Suzhou) Co., Ltd.Rachel Hua
[email protected]

Test Firm

DEKRA Testing and Certification (Suzhou) Co., Ltd.Janet Xu
[email protected]86 512 6251 50885113

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.12 MHz - 0.3 MHz-
Confidentiality
Long Term
Grant Notes
The antenna(s) used for this transmitter must be used to provide a separation distance of at least 15 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except for the conditions shown in this filing and/or in accordance with FCC multi-transmitter product guidelines. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Honeywell International Inc

HD5-CT47HFUHF

A rugged accessory for the Honeywell CT47 mobile computer which enables HF and UHF reading. Reader is supplied from mobile computer CT47.

Aug 04, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
HD5CT47HFUHF

A rugged accessory for the Honeywell CT47 mobile computer which enables HF and UHF reading. Reader is supplied from mobile computer CT47.

Aug 04, 2026

Equipment Class

DTS - Digital Transmission System
HD5-8680IC

Barcode Scanner

Jun 17, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
HD5-CT70X1

Mobile Computer

Jan 26, 2026

Equipment Class

CBE - Citizens Band End User Devices
HD5-1972

Barcode Scanner

Dec 25, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter