Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Honeywell Confidential and Proprietary USER MANUAL IM11-PRT RFID MODULE Revision MODEL NO:IM11-PRT RFID MODULE Table of Contents Introduction ....................................................................................................... 1 Technical Specifications ................................................................................... 3 Mechanical Integration ...................................................................................... 7 Electrical Integration ......................................................................................... 8 Power Requirements ....................................................................... 8 Reader Power States ...................................................................... 9 Supported Antennas: ...................................................................................... 10 Mini-PCI Connector Pin Descriptions .............................................................. 11 Agency Approvals ........................................................................................... 14 FCC Communications commission interface statement ................ 14 Industry Canada .......................................................................... 17 1 Introduction This document specifies the details for a IM11-PRT RFID MODULE About IM11 IM11-PRT RFID Reader Module is designed for quick integration into computers, printers, and any other products that need to be RFID-enabled. The IM11 includes these features:  Allows the RFID-enabled product to read and write to tags used in most worldwide applications: • The IM11 can comply with the regulatory requirements for ETSI 4 channels in Europe, USA, Taiwan, Australia, Thailand, Brazil, Hong Kong, Malaysia, Singapore, China, Philippines, South Africa, Israel, South Korea, and New Zealand. • The IM11 cannot comply with regulatory requirements for Japan. • Operates across the entire frequency band. The country code defines the frequency bands of operation, the power levels, the hop tables, and other country- specific parameters. The default country code is defined by the location where the Chapter 2 module is delivered. • Covers UHF bands from 865 to 928 MHz Supports four channel operation over the 865 to 868 MHz band. • Supports 50 channels in the FCC band from 902 to 928 MHz. • Supports the ISO 18000-6c protocol (EPC Class 1, Gen 2) • Supports the BRI (Basic Reader Interface) host communication protocol. 3 Technical Specifications Physical Specifications Physical 50.95 mm long x 30 mm wide x 4.76 mm thick Weight Environmental Specifications Operating Temperature Storage Temperature -20 °C to +60 °C -40 °C to +70 °C Humidity 25 °C to 60 °C, 0% to 95% relative humidity, non-condensing process Shock 2000 g, 0.5 ms pulse, 10 times on each axis Vibration GRMS. 10 to 500 Hz, in 3 axis ESD Passes CE mark requirements. 4 kV contact discharge and 8 kV air discharge, while unpowered. Chapter Specification Values Specification Values 4 Transmitter Specifications Specification Minimum Typical Maximum Unit Notes Frequency -20 +20 PPM Stability Spurious -55 dBc In band Emissions - -50 dBc Out of band FCC Spurious -54 dBm Out of band Emissions - ETSI 5 Thermal 85 °C As measured by Shutdown sensor on module Thermal 75 °C Recovery Transceiver Specifications Output Power Control 29.5 dBm. User adjustable in 1 dB down to 10.5 dBm. Tolerance drift from +0.5 to -0.7. Bus Interface (USB or serial) USB 2.0 compliant client 12 Mbps (full speed) Serial 115.2 Kbps RF Output Impedance 50 Ohms with better than 10 dB return loss Modulation PR-ASK Data Encoding DRM or FM0 RF Sensitivity DRM: Monostatic 15 dB S/N Power [dBm] ON: -70 dBm RF sensitivity is the minimum RF conducted power for measuring a given 15 dB return loss on the antenna port. Tags/Protocols Supported EPC Class 1 Gen 2, UHF Version 1.2.0 ISO 18000-6C NXP SL3ICS1002 G2XM, can read 512-bit extended user memory and custom commands Fujitsu FJ64 Kb Impinj Monza 4QT Tag Data Rate EPC Class 1 Gen2, ISO 18000-6C DRM back link frequency up to 320 KHz FM0 back link frequency 160 KHz Read Range >6 m (20 ft), provided that the module: • is using DRM operation mode. • isconnected to an antenna system with 9 dBiC gain (circular polarized). • has no occurrence of multipath or other environmental interference. Read Speed >200 tags per second (using 32 conducted Specification Values 6 tags) 50 tags per second (using over air tags) Performance Testing AD 223 tags on cardboard Receiver Specifications Sensitivity Typical: -70 dBm 15 dB return loss Maximum Reverse Input Power Maximum: +20 dBm Receiver Input Values 7 Mechanical Integration The module fits within the Mini PCI Express specifications. For physical dimensions, see the illustration. 8 Electrical Integration The module communicates either over USB or through serial:  The USB client communication follows the CDC profile and is USB 2.0- compliant, operating at 12 Mbps (full speed).  In Serial mode, the module communicates as a standard PC COM port, operating at 115.2 Kbps. It has eight general purpose inputs and outputs for monitoring and controlling external signals. A Digital Signal Processor (DSP) controls the radio functions and provides communication with the host. This interface allows direct reprogramming and updating of the on-board FLASH memory Power Requirements The module operates off power input from 3.15 VDC to 5.2 VDC. If the input is 3.3 V DC or less, you must account for significant increased current demand. If the input drops below 3.15 VDC, 1 Watt output is not possible. The module handles its own power management and goes into Standby mode automatically when there are no outstanding commands. However, even in Standby mode, the IM11 immediately responds to host activity, eliminating any potential host timeout conditions. To achieve an even lower power Standby mode, the host needs to support USB suspend and remote wakeup. 9 To reduce power, the module duty cycle…
Text truncated - open the document above for the full version.
Safety and Productivity Solutions 9680 Old Bailes Road Fort Mill, SC 29707 USA www.honeywell.com www.honeywellaidc.com Date : December 16, 2020 Authorization to Act as Agent On our behalf, I/We appoint Mr. Raghavendra Kulkarni of TUV Rheinland India Ltd. 27/B, 2 nd cross road, Electronic City, Phase 1 Hosur Road Bangalore – 560 100. INDIA to act as my/our agent in the preparation/signing of this application for equipment certification for the following FCC ID: HD5-IM11R. I/We certify that the submitted documents properly describe the device or system for which equipment certification is sought. I/We also certify that each unit manufactured, imported or marketed, as defined in FCC’s regulations, will have affixed to it a label identical to that submitted for approval with this application. Agency Agreement Expiration Date: 30 June 2021 Sincerely, Jesautheen Barakath Ali [email protected] Quality Engineer - Compliance Honeywell International Inc SPS (Safety and Productivity Solutions) Office:+1-803-835-8275
Safety and Productivity Solutions 9680 Old Bailes Road Fort Mill, SC 29707 USA www.honeywell.com www.honeywellaidc.com Date : December 16, 2020 Federal Communications Commission Authorization and Evaluation division Subject: Confidentiality Request for IM11-PRT with FCC ID: HD5-IM11R Pursuant to 47 CRF 0.457(d) and 0.459, Honeywell requests that a part of the subject application be held confidential Type of Confidentiality requested Exhibit Type File name Long Term Block Diagram 145-549-006_003_Block Diagram Long Term Bill of Material 145-549-006_002_BOM Long Term Schematic 145-549-006_001_Schematics Long Term Factory Tuning & Calibration Procedure 145-549-006_010_Factory Tuning & Calibration Procedure Long Term Theory of Operation 145-549-006_008_Theroy of operation The above materials contain proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. Sincerely, Jesautheen Barakath Ali [email protected] Quality Engineer - Compliance Honeywell International Inc SPS (Safety and Productivity Solutions) Office:+1-803-835-8275
Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: Reference Test Report No: ULR-TC568820300000067F Seite 1 von 3 Page 1 of 3 EUT External Photos EUT Top view EUT Bottom view Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: Reference Test Report No: ULR-TC568820300000067F Seite 2 von 3 Page 2 of 3 EUT-Dim ensional View EUT-Dim ensional View Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: Reference Test Report No: ULR-TC568820300000067F Seite 3 von 3 Page 3 of 3 EUT-Dim ensional View Carrier Board setup used for module configuration
PMN: IM11-PRT RFID MODULE MODEL: IM11-PRT FCC ID: HD5-IM11R IC: 1693B-IM11R Picture below shows the label location on IM11-PRT RFID MODULE and the label information.
Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: Reference Test Report No: ULR-TC568820300000067F Seite 1 von 4 Page 1 of 4 EUT Internal Photos EUT-Top-View Shield rem oved EUT-Bottom-View – Shield Rem oved Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: Reference Test Report No: ULR-TC568820300000067F Seite 2 von 4 Page 2 of 4 Carrier board Front view – used for module configuration only Carrier board Bottom view - used for module configuration only Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: Reference Test Report No: ULR-TC568820300000067F Seite 3 von 4 Page 3 of 4 RFID Module Shield opened RFID-without shield Dimensional View Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: Reference Test Report No: ULR-TC568820300000067F Seite 4 von 4 Page 4 of 4 RFID-without shield Dimensional View Carrier Board setup used for module configuration
Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: ReferenceTest Report No: ULR-TC568819300000067F Seite 1 von 3 Page 1 of 3 1 RF Exposure Report This test report shall be used with main report no.: ULR-TC568819300000067F 1.1 RF Exposure Measurement The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 & RSS-102 issue 5 is followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for near field power density. It is taken as worst case to specify the safety range. 1.2 RF Exposure Limit According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of the human exposure to radio-frequency (RF) radiation as specified in 1.1307 (b) showed in Table 1. Table 1: Limits for Maximum Permissible Exposure (MPE) as per FCC Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm²) Limits for Occupational / controlled Exposures 300 - 1500 -- -- F/300 1500 – 100000 -- -- 5.0 Limits for General population / Uncontrolled Exposure 300 - 1500 -- -- F/1500 1500 – 100000 -- -- 1.0 F or ƒ = Frequency in MHz Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: ReferenceTest Report No: ULR-TC568819300000067F Seite 2 von 3 Page 2 of 3 According to IC RSS 102 : The criteria listed in the following table shall be used to evaluate the environmental impact of the human exposure to radio-frequency (RF) radiation as specified in section 4 showed in Table 2. Table 2: Limits for Maximum Permissible Exposure (MPE) as per RSS 1.2.1 Friss Formula Friss Transmission Formula: Pd = (Pout * G) / (4*pi*r²) Where Pd = power density in mW/cm² Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = Distance between observation point and the center of radiator in cm If we know the maximum gain of the antenna and the total output power to the antenna, through calculation, we will know MPE value at distance 20cm. 1.3 Compliance criteria The Radio frequency Human Exposure Evaluation specification, method and procedures for IM11- PRT is in accordance with the following standard FCC 1.1310 and RSS 102 Issue 5 Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: ReferenceTest Report No: ULR-TC568819300000067F Seite 3 von 3 Page 3 of 3 1.4 Test Results Protocol: RFID Data Rate: 320 kbps Antenna types Antenna gain Compact yagi antenna +6 dBi Microstrip antenna coupler -19.96 dBi Microstrip antenna coupler -24.0 dBi MPE calculations : For FCC 1.1307 (b) Frequency (MHz) Measured Pout (dBm ) Output Pow er to Antenna (m W) Output Pow er to Antenna After duty cycle correction (m W) Antenna Gain (dBi) Antenna gain (dBd) Tune up (dB) Maxim um Pout including Tune-up (m W) Pow er Density (Pd) (m W/cm ²) FCC Lim it (m W/cm ²) 927.25 29.76 946.2372 236.5920 6.00 3.9811 ±0.5 265.4606 0.2102 0.43285 MPE calculations : For RSS 102 Issue 5 Frequency (MHz) Measured Pout (dBm ) Output Pow er to Antenna (m W) Output Pow er to Antenna After duty cycle correction (m W) Antenna Gain (dBi) Antenna gain (dBd) Tune up (dB) Maxim um Pout including Tune-up (m W) Pow er Density (Pd) (m W/cm ²) IC Lim it (m W/cm ²) 927.25 29.76 946.2372 236.5920 6.00 3.9811 ±0.5 265.4606 0.2102 0.2792 Note: 1. Tune up tollarance of ± 0.5 dB is considered for MPE calculation, this value is declared by manufacturer. 2. MPE evaluation is performed for 20 cm saperation distance 3. MPE evaluation is performed for highest antenna gain of 6 dBi 4. Manufacturer has declared the maximum duty cycle of 25%, hence duty cycle correction factor is considered for 25% as shown in below formula Duty Cycle Correction Factor Calculation 10*LOG (1/X) Where X is Duty Cycle Duty cycle correction factor = 6.020 dB 1.5 Conclusion: The Power density of the EUT is less than defined limit as shown above, hence EUT is exempted from routine SAR evaluation, this evaluation is only applicable to RF ID transmission
Prüfbericht – Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: ULR- TC568820300000067F Auftrags-Nr.: Order no.: 166501392 10 Seite 1 von 57 Page 1 of 57 Kunden-Referenz-Nr.: Client reference no.: NA Auftragsdatum: Order date: 2020-11-24 Auftraggeber: Client: HONEYWELL INTERNATION INC HONEYWELL SAFETY AND PROUDCTIVITY SOLUTIONS 9680 Old Bailes Road, Fort Mill, SC 29707-7539, USA Prüfgegenstand: Test item: IM11-PRT RFID MODULE Bezeichnung: Identification: IM11-PRT Auftrags-Inhalt: Order content: Testing & issue of FCC and IC grant certificate Prüfgrundlage: Test specification: FCC Part 15 Subpart C 15.247, 15.207 RSS 247 Issue 2, RSS Gen Issue 5 Wareneingangsdatum: Date of sample receipt: 2020-11-12 Prüfmuster-Nr.: & Serien -Nr.: Test sample no & Serial no.: A002948490-006 & 203400069 Prüfzeitraum: Testing period: 2020-11-13 - 2020-11-17 Ort der Prüfung: Place of testing: Wireless laboratory, Bangalore Prüflaboratorium: Testing laboratory: TÜV Rheinland (India) Pvt.Ltd.,27/B, 2nd Cross, ElectronicCityPhase1 Bangalore – 560 100, India FCC Test Site Registration No: 496599 Prüfergebnis*: Test result*: Pass geprüft von: tested by: genehmigt von: authorized by: Datum: Date: 2020-12-08 Ausstellatum: Issue date: 2020-12-30 Stellung / Position: Rajesh M Gowda Engineer Stellung / Position: Mahammadgouse Kaladagi Assistant Manager Sonstiges / Other: FCC ID : HD5-IM11R IC : 1693B-IM11R Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhaft P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TÜV Rheinland (India) Pvt. Ltd, Plot No.27/B, 2nd Cross, Electronic city, Industrial Area, Phase I, Hosur Road Bangalore-560 100, India Mail: [email protected] ∙ Web: www.ind.tuv.com Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: ULR-TC568820300000067F Seite 2 von 57 Page 2 of 57 TEST SUMMARY Test Item FCC IC Result Maximum conducted (Peak) output power 15.247 (b)(2) RSS-247 issue 2 5.4 (a) Pass Occupied bandwidth 15.247 (a) (1) (i) RSS-247 issue 2 5.1 (c) Pass Number of Hopping channels 15.247 (a) (1) (i) RSS-247 issue 2 5.1 (c) Pass Carrier Frequency Separation 15.247 (a) (1) RSS-247 issue 2 5.1 (b) Pass Time of Occupancy (Dwell Time) 15.247 (a) (1) (i) RSS-247 issue 2 5.1 (c) Pass Emissions in non-restricted frequency bands and Conducted Spurious Emission 15.247 (d) RSS-247 issue 2 5.5 Pass Spurious Radiated Emissions and Restricted Bands of Operation 15.247 (d) / (15.209 & 15.205) RSS-GEN issue 5 Clause 8.9, 8.10 Pass Conducted Emissions on Power Lines FCC 15.207 RSS-Gen Issue 5,Section 8.8 Pass Product Category: Electronics Testing Test Discipline: EMC Test Facility Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: ULR-TC568820300000067F Seite 3 von 57 Page 3 of 57 REVISION HISTORY OF THIS REPORT Report Number Version Description Issue date ULR-TC568820300000067F 01 Initial issue of report 2020-12-30 Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: ULR-TC568820300000067F Seite 4 von 57 Page 4 of 57 Table of Contents 1 GENERAL REMARKS ........................................................................................................................................... 5 1.1 Attachments .................................................................................................................................................. 5 2 TEST SITES .......................................................................................................................................................... 6 2.1 Testing Facilities............................................................................................................................................ 6 2.2 List of Test and Measurement Instruments ................................................................................................... 6 3 GENERAL PRODUCT INFORMATION ................................................................................................................. 8 3.1 Product Function and Intended Use.............................................................................................................. 8 3.2 Ratings and System Details of Equipment under Test ................................................................................. 8 3.3 Measurement Uncertainty: ............................................................................................................................ 9 4 TEST SET-UP AND OPERATION MODE ........................................................................................................... 10 4.1 Principle of Configuration Selection ............................................................................................................ 10 4.2 Test Operation and Test Software .............................................................................................................. 10 4.3 Special Accessories and Auxiliary Equipment ............................................................................................ 10 4.4 Countermeasures to achieve EMC Compliance ..........................................................…
Text truncated - open the document above for the full version.
Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: Reference Test Report No: ULR-TC568820300000067F Seite 1 von 6 Page 1 of 6 Frequency range :9KHz–30MHz Polarization : Parallel Frequency range :9KHz–30MHz Polarization : Perpendicular Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: Reference Test Report No: ULR-TC568820300000067F Seite 2 von 6 Page 2 of 6 Frequency range :30MHz–200MHz Polarization : Vertical Frequency range : 30MHz–200MHz Polarization : Horizontal Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: Reference Test Report No: ULR-TC568820300000067F Seite 3 von 6 Page 3 of 6 Frequency range :200MHz–1GHz Polarization : Vertical Frequency range :200MHz–1GHz Polarization : Horizontal Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: Reference Test Report No: ULR-TC568820300000067F Seite 4 von 6 Page 4 of 6 Frequency range :1GHz-18GHz Polarization : Vertical Frequency range :1GHz-18GHz Polarization : Horizontal Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: Reference Test Report No: ULR-TC568820300000067F Seite 5 von 6 Page 5 of 6 EUT closeup Radiated test setup of Yagi Antenna EUT closeup Radiated test setup of Microstrip antenna coupler Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: Reference Test Report No: ULR-TC568820300000067F Seite 6 von 6 Page 6 of 6 Antenna Port measurement Test Setup Photo Conducted AC Power Line Test setup Photo
Honeywell Safety and Productivity Solutions · Fort Mill · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.75 MHz - 927.25 MHz | 946.20 mW |
A rugged accessory for the Honeywell CT47 mobile computer which enables HF and UHF reading. Reader is supplied from mobile computer CT47.
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterA rugged accessory for the Honeywell CT47 mobile computer which enables HF and UHF reading. Reader is supplied from mobile computer CT47.
Equipment Class
DTS - Digital Transmission SystemBarcode Scanner
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterMobile Computer
Equipment Class
CBE - Citizens Band End User DevicesBarcode Scanner
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter