FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Accton Technology Corp/
  3. HED7404WBRAACC

HED7404WBRAACCWireless ADSL Barricade, Wireless ADSL Router

Accton Technology Corp
Wireless ADSL Barricade, Wireless ADSL Router - FCC ID HED7404WBRAACC - Accton Technology Corp
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 27, 2003
Application Purpose
Original Equipment
Date of Application
Apr 27, 2003
Equipment Note
Wireless ADSL Barricade, Wireless ADSL Router
Frequency Range
2412.00000000 - 2462.00000000
Company
Accton Technology Corp
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗
↗
↗
↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Barricade ADSL Router Wireless Broadband Router with built-in ADSL Modem  Compatible with all leading DSLAMs  Firewall (hacker attack logging, DoS, and client filtering)  Supports DMT line modulation  Four auto-negotiating 10/100 Ethernet ports  Built-in print server  PPTP, L2TP, and IPSec pass through  Multiple user Internet access with a single-user account  Supports PPPoE and PPPoA  Plug & Play installation  Web-based management User Guide SMC7404WBRA 38 Tesla Irvine, CA 92618 Phone: (949) 679-8000 Wireless Broadband Router with built-in ADSL Modem From SMC’s line of award-winning connectivity solutions March 2003 Part No: 750.9077 R01 Pub No: 150000018500E R01 Information furnished is believed to be accurate and reliable. However, no responsibility is assumed by our company for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of our company. We reserve the right to change specifications at any time without notice. Copyright © 2003 by SMC Networks, Inc. 38 Tesla Irvine, CA 92618 All rights reserved. Printed in Taiwan Trademarks: SMC is a registered trademark; and Barricade is a trademark of SMC Networks, Inc. Other product and company names are trademarks or registered trademarks of their respective holders. i LIMITED WARRANTY Limited Warranty Statement: SMC Networks, Inc. (“SMC”) warrants its products to be free from defects in workmanship and materials, under normal use and service, for the applicable warranty term. All SMC products carry a standard 90-day limited warranty from the date of purchase from SMC or its Authorized Reseller. SMC may, at its own discretion, repair or replace any product not operating as warranted with a similar or functionally equivalent product, during the applicable warranty term. SMC will endeavor to repair or replace any product returned under warranty within 30 days of receipt of the product. The standard limited warranty can be upgraded to a Limited Lifetime* warranty by registering new products within 30 days of purchase from SMC or its Authorized Reseller. Registration can be accomplished via the enclosed product registration card or online via the SMC Web site. Failure to register will not affect the standard limited warranty. The Limited Lifetime warranty covers a product during the Life of that Product, which is defined as the period of time during which the product is an “Active” SMC product. A product is considered to be “Active” while it is listed on the current SMC price list. As new technologies emerge, older technologies become obsolete and SMC will, at its discretion, replace an older product in its product line with one that incorporates these newer technologies. At that point, the obsolete product is discontinued and is no longer an “Active” SMC product. A list of discontinued products with their respective dates of discontinuance can be found at: http://www.smc.com/index.cfm?action=customer_service_warranty. All products that are replaced become the property of SMC. Replacement products may be either new or reconditioned. Any replaced or repaired product carries either a 30-day limited warranty or the remainder of the initial warranty, whichever is longer. SMC is not responsible for any custom software or firmware, configuration information, or memory data of Customer contained in, stored on, or integrated with any products returned to SMC pursuant to any warranty. Products returned to SMC should have any customer-installed accessory or add-on components, such as expansion modules, removed prior to returning the product for replacement. SMC is not responsible for these items if they are returned with the product. Customers must contact SMC for a Return Material Authorization number prior to returning any product to SMC. Proof of purchase may be required. Any product returned to SMC without a valid Return Material Authorization (RMA) number clearly marked on the outside of the package will be returned to customer at customer’s expense. For warranty claims within North America, please call our toll-free customer support number at (800) 762-4968. Customers are responsible for all shipping charges from their facility to SMC. SMC is responsible for return shipping charges from SMC to customer. LIMITED WARRANTY ii WARRANTIES EXCLUSIVE: IF AN SMC PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT OF THE PRODUCT IN QUESTION, AT SMC’S OPTION. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. SMC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS. SMC SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER’S OR ANY THIRD PERSON’S MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, OR OTHER HAZARD. LIMITATION OF LIABILITY: IN NO EVENT, WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE), SHALL SMC BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE, LOSS OF BUSINESS, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF SMC OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR THE LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGE…

Text truncated - open the document above for the full version.

Users Manual

CONFIGURING CLIENT PC 3-26 2. Your new settings are shown in the TCP/IP window. Verify that your IP Address is now 192.168.2.xxx, your Subnet Mask is 255.255.255.0 and your Default Gateway is 192.168.2.1. These values confirm that your Barricade is functioning. 3. Close the TCP/IP window. Now your computer is configured to connect to the Barricade. 4-1 CHAPTER 4 C ONFIGURING THE BARRICADE After you have configured TCP/IP on a client computer, use a Web browser to configure the Barricade. The Barricade can be configured by any Java-supported browser including Internet Explorer 4.0 or above, or Netscape Navigator 4.0 or above. Using the Web management interface, you may configure the Barricade and view statistics to monitor network activity. To access the Barricade’s management interface, enter the IP address of the Barricade in your web browser: http://192.168.2.1 (The Barricade automatically switches to Port 88 for management access.) Then click LOGIN. (By default, there is no password.) CONFIGURING THE BARRICADE 4-2 Navigating the Web Browser Interface The Barricade’s management interface consists of a Setup Wizard and an Advanced Setup section. Setup Wizard: Use the Setup Wizard if you want to quickly set up the Barricade. Go to “Setup Wizard” on page 4-3. Advanced Setup: Advanced Setup supports more advanced functions like hacker attack detection, IP and MAC address filtering, virtual server setup, virtual DMZ host, as well as other functions. Go to “Advanced Setup” on page 4-13. Making Configuration Changes Configurable parameters have a dialog box or a drop-down list. Once a configuration change has been made on a page, click the APPLY or NEXT button at the bottom of the page to enable the new setting. Note:To ensure proper screen refresh after a command entry, be sure that Internet Explorer 5.0 is configured as follows: Under the menu Tools/Internet Options/General/Temporary Internet Files/Settings, the setting for “Check for newer versions of stored pages” should be “Every visit to the page.” SETUP WIZARD 4-3 Setup Wizard Time Zone Click on the Setup Wizard picture. The first item in the Setup Wizard is Time Zone. For accurate timing of log entries and system events, you need to set the time zone. Select your time zone from the drop-down list, and click NEXT. If your area requires it, check to enable the clock for daylight saving changes, and enter the Daylight Saving Time start and end dates for your location. CONFIGURING THE BARRICADE 4-4 Internet Sharing Select the operation mode protocol. For Disable Internet Sharing see the following page, and click NEXT. To select one of the other modes, go to “PPPoE & PPPoA - Parameter Setting” on page 4-7, or go to “Multiple Protocol over ATM Mode - Parameter Setting” on page 4-10. SETUP WIZARD 4-5 Disable Internet Sharing - Parameter Setting Enter VPI/VCI value in the provided spaces, then click NEXT. ParameterDescription VPI/VCIData flows are broken up into fixed length cells, each of which contains a Virtual Path Identifier (VPI) that identifies the path between two nodes, and a Virtual Circuit Identifier (VCI) that identifies the data channel within that virtual path. Each virtual circuit maintains a constant flow of cells between the two end points. When there is no data to transmit, empty cells are sent. And when data needs to be transmitted, it is immediately inserted into the cell flows. CONFIGURING THE BARRICADE 4-6 Disable Internet Sharing - Finish The Finish page allows you to view the connection status, as well as other information. Click APPLY. Your Barricade is now set up. If you cannot make a connection to the Internet, go to “Troubleshooting” on page A-1. ParameterDescription ProtocolIndicates the protocol used. VPI/VCIVirtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI). Go to “VPI/VCI” on page 4-5 for detailed description. AAL5 EncapsulationShows the packet encapsulation type. Go to “Encapsulation” on page 4-20 for detailed description. SETUP WIZARD 4-7 PPPoE & PPPoA - Parameter Setting Enter the PPPoE (Point-to-Point Protocol over Ethernet) information in the provided spaces, and click NEXT. ParameterDescription UsernameEnter the ISP assigned user name. PasswordEnter your password. Retype PasswordConfirm the password. DNSEnter a Domain Name Server IP address. VPI/VCIVirtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI). Go to “VPI/VCI” on page 4-5 for detailed description. CONFIGURING THE BARRICADE 4-8 PPPoE & PPPoA - Finish The Finish page allows you to view the connection status, as well as other information. Click APPLY. ParameterDescription ADSL Operation Mode (WAN) ProtocolIndicates the protocol used VPI/VCIVirtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI). Go to “VPI/VCI” on page 4-5 for detailed description. AAL5 EncapsulationShows the packet encapsulation type. Go to “Encapsulation” on page 4-20 for detailed description. ISP Parameters UsernameThe ISP assigned user name. PasswordThe password (hidden). SETUP WIZARD 4-9 Your Barricade is now set up. If you cannot make a connection to the Internet, go to “Troubleshooting” on page A-1. DHCP Parameters Default GatewayThe default gateway IP address. If the Barricade cannot find the destination address within its local network, it will forward the packets to the Default Gateway (usually supplied by your ISP). Subnet MaskThe network subnet mask. Name Server 1Primary name server IP address. Name Server 2Alternate name server IP address. Name Server 3Alternate name server IP address. Start IP AddressStart IP address of DHCP assigned IP addresses. Number of IPNumber of IPs available for assignment by the DHCP server. ParameterDescription CONFIGURING THE BARRICADE 4-10 Multiple Protocol over ATM Mode - Parameter Setting Enter ATM (Asynchronous Transfer Mode) information in the provided spaces, and click NEXT. ParameterDescription DNSEnter a Domain Name Server IP address. WAN IPEnter an IP address for the Barricade WAN interface. Su…

Text truncated - open the document above for the full version.

Users Manual

WIRELESS 4-25 Wireless The Barricade also operates as a wireless-to-wired bridge, allowing wireless computers to access resources available on the wired LAN, and to access the Internet. To configure the Barricade as a wireless access point for wireless clients (either stationary or roaming), all you need to do is enable the wireless function, define the radio channel, the domain identifier, and the encryption options. Check Enable and click APPLY. CONFIGURING THE BARRICADE 4-26 Channel and SSID You must specify a common radio channel and SSID (Service Set ID) to be used by the Barricade Wireless Router and all of your wireless clients. Be sure you configure all of your clients to the same values. ParameterDescription ESSIDExtended Service Set ID. The ESSID must be the same on the Barricade and all of its wireless clients. Transmission Rate The default is Fully Automatic. The transmission rate is automatically adjusted based on the receiving data error rate. Usually the connection quality will vary depending on the distance between the wireless router and wireless adapter. You can also select a lower transmission data rate to maximize the radio communication range. WIRELESS 4-27 Basic RateThe highest rate specified will be the rate that the Barricade will use when transmitting broadcast/multicast and management frames. Available options are: All (1, 2, 5.5, and 11Mbps), and 1, 2Mbps (default is 1, 2Mbps). ChannelThe radio channel must be the same on the Barricade and all of your wireless clients. The Barricade will automatically assign itself a radio channel, or you may select one manually. ParameterDescription CONFIGURING THE BARRICADE 4-28 Encryption If you are transmitting sensitive data across wireless channels, you should enable encryption. You must use the same set of encryption keys for the Barricade and all of the wireless clients. Choose between standard 64-bit WEP (Wired Equivalent Privacy) or the more robust 128-bit encryption. You may automatically generate encryption keys or manually enter the keys. For automatic 64-bit security, enter a passphrase and click Generate, four keys will be generated. Choose a key from the drop-down list or accept the default key. Automatic 128-bit security generates a single key. Note: The passphrase can consist of up to 32 alphanumeric characters. To manually configure the keys, enter five hexadecimal pairs of digits for each 64-bit key, or enter 13 pairs for the single 128-bit key. (A hexadecimal digit is a number or letter in the range 0-9 or A-F.) Note that WEP protects data transmitted between wireless nodes, but does not protect any transmissions over your wired network or over the Internet. WIRELESS 4-29 MAC Address Filtering Client computers can be filtered using the unique MAC address of their IEEE 802.11 network card. To secure an access point using MAC address filtering, you must enter a list of allowed/denied client MAC addresses into the filtering table. (See “Finding the MAC address of a Network Card” on page 4-57.) ParameterDescription Filtering DisableDisables MAC address filtering. EnableEnables MAC address filtering. Setting PermissionsAllows only devices with their MAC address in the list to connect to the Barricade. ProhibitionDenies access to the Barricade from devices with their MAC address in the list. CONFIGURING THE BARRICADE 4-30 NAT Some applications require multiple connections, such as Internet gaming, videoconferencing, and Internet telephony. These applications may not work when Network Address Translation (NAT) is enabled. If you need to run applications that require multiple connections, use these pages to specify the additional public ports to be opened for each application. Address Mapping Allows one or more public IP addresses to be shared by multiple internal users. This also hides the internal network for increased privacy and security. Enter the Public IP address you wish to share into the Global IP field. Enter a range of internal IPs that will share the global IP into the from field. NAT 4-31 Virtual Server If you configure the Barricade as a virtual server, remote users accessing services such as Web or FTP at your local site via public IP addresses can be automatically redirected to local servers configured with private IP addresses. In other words, depending on the requested service (TCP/UDP port number), the Barricade redirects the external service request to the appropriate server (located at another internal IP address). If you configure the Barricade as a virtual server, remote users accessing services such as Web or FTP at your local site via public IP addresses can be automatically redirected to local servers configured with private IP addresses. In other words, depending on the requested service (TCP/UDP port number), the Barricade redirects the external service request to the appropriate server (located at another internal IP address). CONFIGURING THE BARRICADE 4-32 For example, if you set Type/Public Port to TCP/80 (HTTP or Web) and the Private IP/Port to 192.168.2.2/80, then all HTTP requests from outside users will be transferred to 192.168.2.2 on port 80. Therefore, by just entering the IP Address provided by the ISP, Internet users can access the service they need at the local address to which you redirect them. The more common TCP service ports include: HTTP: 80, FTP: 21, Telnet: 23, and POP3: 110. A list of ports is maintained at the following link: http://www.iana.org/assignments/port-numbers. Note:The WAN interface should have a fixed IP address to best utilize this function. If your ISP only provides dynamic IP addresses, a search for “free dynamic IP” on any major search engine will turn up tools that will allow you to use the same domain name even though your IP address changes each time you log into the ISP. ROUTING SYSTEM 4-33 Routing System These pages define routing related parameters, including static routes and RIP (Routing Information Protocol) parameters. Static Route Click A…

Text truncated - open the document above for the full version.

Users Manual

CONFIGURING THE BARRICADE 4-50 Status ADSL 4-51 ParameterDescription Status Line StatusShows the current status of the ADSL line. Data Rate UpstreamMaximum data rate upstream. DownstreamMaximum data rate downstream. Operation Data/Defect Indication Noise Margin UpstreamMinimum noise margin upstream. DownstreamMinimum noise margin downstream. Output PowerMaximum fluctuation in the output power. Attenuation UpstreamMaximum reduction in the strength of the upstream signal. DownstreamMaximum reduction in the strength of the downstream signal. Fast Path FEC Correction There are two latency paths that may be used: fast and interleaved. For either path a forward error correction (FEC) scheme is employed to ensure higher data integrity. For maximum noise immunity, an interleaver may be used to supplement FEC. Interleaved Path FEC Correction An interleaver is basically a buffer used to introduce a delay, allowing for additional error correction techniques to handle noise. Interleaving slows the data flow and may not be optimal for real-time signals such as video transmission. Fast Path CRC Error Indicates the number of Fast Path Cyclic Redundancy Check errors. Interleaved Path CRC Error Indicates the number of Interleaved Path Cyclic Redundancy Check errors. Loss of Signal Defect Momentary signal discontinuities. Loss of Frame Defect Failures due to loss of frames. CONFIGURING THE BARRICADE 4-52 Loss of Power Defect Failures due to loss of power. Fast Path HEC Error Fast Path Header Error Concealment errors. Interleaved Path HEC Error Interleaved Path Header Error Concealment errors. Statistics(Superframes represent the highest level of data presentation. Each superframe contains regular ADSL frames, one of which is used to provide superframe synchronization, identifying the start of a superframe. Some of the remaining frames are also used for special functions.) Received Superframes Interleaved Number of interleaved superframes received. Transmitted Superframes Interleaved Number of interleaved superframes transmitted. Received Superframes Fast Number of fast superframes received. Transmitted Superframes Fast Number of fast superframes transmitted. ParameterDescription TOOLS 4-53 Tools Use the Tools menu to backup the current configuration, restore a previously saved configuration, restore factory settings, update firmware, and reset the Barricade. Configuration Tools Choose a function and click More Configuration. Backup allows you to save the Barricade Router’s configuration to a file. You can then check Restore to restore the saved backup configuration file. Restore to Factory Defaults resets the Barricade to the original settings. You will be asked to confirm your decision. CONFIGURING THE BARRICADE 4-54 Firmware Upgrade Use this screen to update the firmware or user interface to the latest versions. Download the upgrade file from the SMC Web site (www.smc.com) and save it to your hard drive. In the Upgrade Target field, choose Firmware. Then click Browse to look for the previously downloaded file. Click APPLY. Check the Status page Information section to confirm that the upgrade process was successful. TOOLS 4-55 Reset Click APPLY to reset the Barricade. The reset will be complete when the power LED stops blinking. If you perform a reset from this page, the configurations will not be changed back to the factory default settings. Note:If you use the Reset button on the front panel, the Barricade performs a power reset. If the button is held depressed for over five seconds, all the LEDs will illuminate and the factory settings will be restored. CONFIGURING THE BARRICADE 4-56 Status The Status screen displays WAN/LAN connection status, firmware, and hardware version numbers, illegal attempts to access your network, as well as information on DHCP clients connected to your network. The security log may be saved to a file by clicking Save and choosing a location. FINDING THE MAC ADDRESS OF A NETWORK CARD 4-57 The following items are included on the Status screen: Finding the MAC address of a Network Card Windows 95/98/ME Click Start/Run. Type “winipcfg” and press ENTER. The MAC address is in the “Adapter Address” section. Windows NT4/2000/XP Click Start/Programs/Command Prompt. Type “ipconfig /all” and press ENTER. The MAC address is listed as the “Physical Address.” Linux Run the command “/sbin/ifconfig.” The MAC address is the value after the word “HWaddr.” ParameterDescription INTERNETDisplays WAN connection type and status. GATEWAYDisplays system IP settings, as well as DHCP Server and Firewall status. INFORMATIONDisplays the number of attached clients, the firmware versions, the physical MAC address for each media interface, and for the Barricade, as well as the hardware version and serial number. Security LogDisplays illegal attempts to access your network. DHCP Client LogDisplays information on DHCP clients on your network. CONFIGURING THE BARRICADE 4-58 5-1 CHAPTER 5 C ONFIGURING PRINTER SERVICES To use the print server built into the Barricade, you must first install the Port Monitor program as described in the following section for Windows 95/98/Me. To set up the Barricade Print Server for Windows NT, see “Printer Server Setup in Windows NT” on page 5-4. For Windows 2000, see “Printer Server Setup in Windows 2000” on page 5-6. For Windows XP, see “Printer Server Setup in Windows XP” on page 5-8. For Unix Systems, see “Printer Server Setup in Unix Systems” on page 5-18. Printer Server Setup in Windows 95/98/ Me You may find that the instructions here do not exactly match your version of Windows. This is because these steps and screenshots were created in Windows 98. Windows 95 and Windows Millennium Edition are very similar, but not identical, to Windows 98. 1. Insert the installation CD-ROM into your CD-ROM drive. Under the PrintSvr directory, run the “setup.exe” program. The Port Monitor installation program advises you to close all other Windows programs currently running on your comp…

Text truncated - open the document above for the full version.

Attestation Statements

[email protected] www.adt.com.tw ADVANCE DATA TECHNOLOGY CORPORATION FEDERAL COMMUNICATIONS COMMISSION DECLARATION OF CONFORMITY (DoC) FOR THE FOLLOWING EQUIPMENT: PRODUCT NAME : MODEL NO : SMC7404WBRA;AR3505AW-A TRADE NAME : SMC; Accton IS HEREWITH CONFIRMED AND FOUND TO COMPLY WITH THE REQUIREMENTS OF CFR 47 PART 15 REGULATION. THE RESULTS OF ELECTROMAGNETIC EMISSION EVALUATION ARE SHOWN IN THE REPORT NO : RF911125H02 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND, (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. THE FOLLOWING LOCAL MANUFACTURER/IMPORTER IS RESPONSIBLE FOR THIS DECLARATION ManufacturerUSA Local Representative Company name: Accton Technology Corporation Company name: SMC Networks Address: No.1, Creation Rd. III, Science-based Industrial Park, Hsinchu, Taiwan, R.O.C. Address: 38 Tesla Irvine, CA 92618 Contact Person: Hsoang-Shen Chen Contact Person: Kelaine Hamilton Title: Section Manager Title: Product Line Manager Tel/Fax: Tel:886-3-5770270 Fax:886-3-5783839 Tel/Fax: Tel:949-981-5912 Fax:949-679-1481

External Photos

Page 1 CONSTRUCTION PHOTOS OF EUT

ID Label/Location Info

(Fig. 1) FCC ID: FCC LABEL LOCATION The label will be permanently affixed at a conspicuous location on the device. Label

ID Label/Location Info

Decided by Vendor ID number Decided by import and export country 662968 575668 S

Internal Photos

Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8

Operational Description

FCC ID: HED7404WBRAACC Report No.: 911125H02 ADT No.: 911125H02 Operational Description The transmitter of the EUT (Wireless ADSL Barricade, Wireless ADSL Router) is powered by power adapter. The antenna used in this product is Integral Antenna without connector. Under normal use condition, the user has to keep at least 20cm separation distance between radiator and the body of the user. The other instruction, please have a look at the users manual. DSSS Information This device is Direct Sequence Spread Spectrum, the data is mixed by pseudorandom code which is an orthogonal code. The mixed data is digital modulated by DBPSK and DQPSK technique depends on the data rates. The CCK coding is applied for increasing the data rate, and also the processing gain will be increased. The bit rates are 1,2,5.5,11Mbps.

RF Exposure Info

FCC ID: HED7404WBRAACC Report No.: 911125H02 RF EXPOSURE REPORT REPORT NO.: RF911125H02 MODEL NO.: SMC7404WBRA, AR3505AW-A ACCORDING: FCC Guidelines for Human Exposure IEEE C95.1 APPLICANT: Accton Technology Corporation ADDRESS: No.1, Creation Rd. III, Science-based Industrial Park, Hsinchu, Taiwan, R.O.C ISSUED BY: Advance Data Technology Corporation LAB LOCATION: No. 81-1, Lu Liao Keng, 9 Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien, Taiwan, R.O.C. Lab Code: 200376-0 FCC ID: HED7404WBRAACC Report No.: 911125H02 RF Exposure Measurement 1. Introduction In this document, we try to prove the safety of radiation harmfulness to the human body for our product. The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 is followed. The Gain of the antenna used in this product is measured in a Fully Anechoic Chamber (FAC) calibrated for antenna measurement in ADT, and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis transmission formula is a far field assumption, the calculated result of that is an over-prediction for near field power density. We will take that as the worst case to specify the safety range. 2. RF Exposure Limit According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified in 1.1307(b) LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (minutes) (A)Limits For Occupational / Control Exposures 300-1500......F/3006 1500-100,000......56 (B)Limits For General Population / Uncontrolled Exposure 300-1500......F/15006 1500-100,000......1.030 F = Frequency in MHz FCC ID: HED7404WBRAACC Report No.: 911125H02 3. Friis Formula Friis transmission formula : Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm Pd is the limit of MPE, 1 mW/cm 2 . If we know the maximum Gain of the antenna and the total power input to the antenna, through the calculation, we will know the MPE value at distance 20cm. Ref. : David K. Cheng, Field and Wave Electromagnetics, Second Edition, Page 640, Eq. (11-133). 4 EUT Operating condition The software provided by Manufacturer enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. 5 Climate Condition The temperature and related humidity: 20 deg. C and 63 % RH 6. Classification This device is not fixed inside the host equipment, it is connected with host through wire. So it is easy to be re-located in the place where at least 20 cm far away from the body of the user. Warning statement to the user for keeping at least 20cm or more separation distance with the antenna should be included in users manual. So, this device is classified as Mobile Device. FCC ID: HED7404WBRAACC Report No.: 911125H02 7 Test Results 7.1 Antenna Gain The maximum Gain measured in Fully Anechoic Chamber is 1.8Bi or 1.51 (numeric). 7.2 Output Power Into Antenna & RF Exposure value at distance 20cm: Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 1241236.40.010941.0 6243736.060.0108381.0 11246240.00.0120221.0

Test Report

FCC ID: HED7404WBRAACC Report No.: RF911125H021Issued: Apr. …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Abby Wei(Manager)
[email protected]886-3-577-0270Fax: 886-3-578-7550

Technical Contact

Advance Data Technology CorporationEric Lin
[email protected]+886 3 593 5343

81-1 Luliaoken, 9 th Lin, Wulung Tsuen Chiunglin · Hsinchu · Taiwan

Test Firm

Bureau Veritas CPS (H.K.) Ltd. Taoyuan BranchRichard Chen
[email protected]886-2-2605-2180-3Fax: 886-2-2605-2943

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz40.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Accton Technology Corp

Wi-Fi 7 AP - FCC ID HEDEAP115 - Accton Technology Corp
HEDEAP115

Wi-Fi 7 AP

Jan 27, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Wi-Fi 6 IoT Gateway - FCC ID HEDEAP112 - Accton Technology Corp
HEDEAP112

Wi-Fi 6 IoT Gateway

Oct 13, 2024

Equipment Class

DTS - Digital Transmission System
Wi-Fi 6 Access Point - FCC ID HEDEAP111 - Accton Technology Corp
HEDEAP111

Wi-Fi 6 Access Point

Mar 17, 2024

Equipment Class

DTS - Digital Transmission System
Outdoor Access Point - FCC ID HEDOAP101E - Accton Technology Corp
HEDOAP101E

Outdoor Access Point

Oct 24, 2023

Equipment Class

DTS - Digital Transmission System
Indoor Wall Plate WiFi 6 Access Point - FCC ID HEDEAP104 - Accton Technology Corp
HEDEAP104

Indoor Wall Plate WiFi 6 Access Point

Dec 14, 2022

Equipment Class

DTS - Digital Transmission System