FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Unitech Electronics Co., Ltd./
  3. HLERM300PU

HLERM300PURM300 Plus UHF RFID Reader Module

Unitech Electronics Co., Ltd.
RM300 Plus UHF RFID Reader Module - FCC ID HLERM300PU - Unitech Electronics Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 01, 2024
Application Purpose
Original Equipment
Date of Application
Aug 29, 2024
Equipment Note
RM300 Plus UHF RFID Reader Module
Frequency Range
902.75000000 - 927.25000000
Company
Unitech Electronics Co., Ltd.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

© 2024 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd. All product and company names are trademarks, service marks, or registered trademarks of their respective owners 4-Port UHF RFID Reader Module - RM300 Plus - User Manual V1.0 © 2024 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd. All product and company names are trademarks, service marks, or registered trademarks of their respective owners Revision History Date Change Description Version 20240719 First Published Version V1.0 i © 2024 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd. All product and company names are trademarks, service marks, or registered trademarks of their respective owners About This Manual Preface Thank you for purchasing the Unitech product. This manual explains how to install, operate and maintain our product. No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, such as photocopying, recording, or information storage and retrieval systems, without permission in writing from the manufacturer. The material in this manual is subject to change without notice. Regulatory Compliance Statements FCC Warning Statement This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference with radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference with radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: –Reorient or relocate the receiving antenna. –Increase the separation between the equipment and receiver. –Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. –Consult the dealer or an experienced radio/TV technician for help. ii © 2024 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd. All product and company names are trademarks, service marks, or registered trademarks of their respective owners 1. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2. This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. To maintain compliance with FCC RF exposure requirements, avoid direct contact to the transmitting antenna during transmitting. 3. Any changes or modifications (including the antennas) made to this device that are not expressly approved by the manufacturer may void the user’s authority to operate the equipment. 4. Operation of transmitters in the 5.925-7.125 GHz band is prohibited for control of or communications with unmanned aircraft systems. FCC Label Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. RF Radiation Exposure Statement For body contact during operation, this device has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the handset a minimum of 1.0 cm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. iii © 2024 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd. All product and company names are trademarks, service marks, or registered trademarks of their respective owners IC Statements This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. iv © 2024 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd. All product and company names are trademarks, serv…

Text truncated - open the document above for the full version.

Attestation Statements

Unitech Electronics Co., Ltd. U.S. Agent Designation for Seruice of Process (Applicant and U.S. Agent are Separate Parties) TO: Kiwa Nederland B.V, lllilmersdorf 50 7327 AC Apeldoom Posbus 137 7300 AC Apeldoom Nethe,lands ATTENTION: FGC Certification - Section 2.9f f {dX7) lnformation D+ei n{ts,{ 1L"*. Aqent Companv name: Unitech America lnc. Contact pe6on name: Larry Ru (FRN: 0033467465) Street address: 6182 Katella Ave ZIPlCity/State Cypress CA 90630 Telephone nur,nber: 714-681-8638 Emailaddress: [email protected] Signature: Date: This letter is to confirm that we ("the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S, Agent for Service of Process as required by seclion 47 CFR 2.91 1(dX7) on behalf of the Applicant noted below. ;;;;;;;;;:;.;;;";;". ;;, ;; ;;;;; ;,;,;,^ ;;;;, ;. ;" ",;;;;;;;;. after terminating all marketing and importation OR the conclusion of any Commission- related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Companv name: Unitech Electronics Co., Ltd. Grantee Code: HLE Contact person name: Ben Chiang Street address: 5F., No. 136, Ln.235, Baoqiao Rd. , Xindian Dist., ZIPlCitylState NewTaipei Cig Telephone number: 88*2-8912-1122 Emailaddress:[email protected] Signature: Date: P,p* Cliar\ AUG 22, ZOZ+ J Doc nr. -"/fl.rA [',, AUG22,2@4

External Photos

Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 2 of 17 External Photos Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 3 of 17 Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 4 of 17 Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 5 of 17 Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 6 of 17 Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 7 of 17 Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 8 of 17 Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 9 of 17

ID Label/Location Info

Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd.Appendix page 7 of 17

Internal Photos

Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 10 of 17 Internal Photos Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 11 of 17 Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 12 of 17 Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 13 of 17 Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 14 of 17

RF Exposure Info

of Applicant: unitech Electronics Co., Ltd. Address: 5F., No. 136, Ln. 235, Baoqiao Rd. , Xindian Dist., New Taipei City , Taiwan Tested and Prepared by Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Report No.: W6M22312-23185-EE 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E- mail: [email protected] FCC RF Exposure Exemption report for RM300 Plus UHF RFID Reader Module Model No.: RM300 Plus FCC ID: HLERM300PU Registration number: W6M22312-23185-EE FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 7 TABLE OF CONTENTS 1 GENERAL INFORMATION ......................................................................................................................................... 2 1.1 NOTES ...................................................................................................................................................................... 2 1.2 TESTING LABORATORY ............................................................................................................................................. 3 1.2.1 Location .............................................................................................................................................................. 3 1.2.2 Details of accreditation status ............................................................................................................................ 3 1.3 APPLICATION DETAILS .............................................................................................................................................. 3 1.4 GENERAL INFORMATION OF TEST ITEM ..................................................................................................................... 4 1.7 TEST STANDARDS ..................................................................................................................................................... 4 2 TEST CONFIGURATION ............................................................................................................................................. 5 2.1 TEST ENVIRONMENT ................................................................................................................................................. 5 2.2 MEASUREMENT UNCERTAINTY ................................................................................................................................. 5 2.3 TEST EQUIPMENT LIST .............................................................................................................................................. 5 3 EQUIVALENT ISOTROPIC RADIATED POWER (EIRP) ...................................................................................... 6 3.1 EXEMPTION LIMITS FOR ROUTINE EVALUATION ...................................................................................................... 6 Registration number: W6M22312-23185-EE FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Page 2 of 7 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. Laboratory disclaimer- 1. The test results of this test report relate exclusively to the item tested as specified in 1.5. 2. The test report may only be reproduced or published in full. 3. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Services(Taiwan) Co., Ltd. 4. Antenna gain is provided by applicant and laboratory issue relevant data and results. Tester: August 21, 2024 Rick Chen Date WTS-Lab. Name Signature Technical responsibility for area of testing: August 21, 2024 Kevin Wang Date WTS Name Signature R egistration number: W6M22312-23185-EE FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Page 3 of 7 1.2 Testing laboratory 1.2.1 Location 1 0m OATS No.5-1, Lishui, Shuang Sing Village, Wanli Dist., New Taipei City 207, Taiwan (R.O.C.) Xizhi Lab No. 99, Sec. 1, Balian Rd., Xizhi Dist., New Taipei City 221032, Taiwan (R.O.C.) Worldwide Testing Services (Taiwan) Co., Ltd. 6F., No. 58, Ln. 188, Ruiguang Rd., Neihu Dist., Taipei City 114 , Taiwan (R.O.C.) Tel: 886-2-6606-8877 1.2.2 Details of accreditation status Accredited testing laboratory FCC filed test laboratory Reg. No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Test location, where different from Worldwide Testing Services (Taiwan) Co., Ltd. : Name: ./. Accredited no.: ./. Street: ./. Town: ./. Country: ./. 1. 3 Application details Approval holder N ame: unitech Electronics Co., Ltd. Street: 5F., No. 136, Ln. 235, Baoqiao Rd. , Xindian Dist., Town: New Taipei City , Country: Taiwan Ma nufacturer: (if applicable) Name: ./. Street: ./. Town: ./. Country: ./. Registration number: W6M22312-23185-EE FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Page 4 of 7 Date of receipt of test item: June 20, 2024 Date of test: from June 21, 2024 to August 13, 2024 1.4 General information of Test item Type of test item: RM300 Plus UHF RFID Reader Module Model number: RM300 Plus Multi-listing model number: ./. Sample no.: #03 Technical data Frequenc…

Text truncated - open the document above for the full version.

Test Report

Operator: Temperature:24.9 °C File :3Data :#5Date: 2024/7/9 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Jeff Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:50.1 % Time: 下午 02:45:47 Condition : EUT : M/N: Note : TX 927.25MHz FCC_part 15 RE-Class C_Above 1GHz_PK W6M22312-23185 Test Mode : Polarization: Vertical Distance: 3m 5 Vd.c. Power : Mk. Frequency (MHz) Reading (dBuV) Corr. factor (dB/m) Result (dBuV/m) Limit (dBuV/m) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment *1855.00050.3057.6674.00-23.70peak-7.36150173 *:Maximum data x:Over limit !:over margin Operator: Temperature:24.9 °C File :3Data :#2Date: 2024/7/9 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Jeff Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:50.1 % Time: 下午 02:43:38 Condition : EUT : M/N: Note : TX 927.25MHz FCC_part 15 RE-Class C_Above 1GHz_PK W6M22312-23185 Test Mode : Polarization: Horizontal Distance: 3m 5 Vd.c. Power : Mk. Frequency (MHz) Reading (dBuV) Corr. factor (dB/m) Result (dBuV/m) Limit (dBuV/m) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment 2782.00043.5747.0974.00-30.43peak-3.52150113 3709.00055.6856.2374.00-18.32peak-0.5515096 *3709.00053.6854.2354.00-0.32AVG-0.5515096 *:Maximum data x:Over limit !:over margin Operator: Temperature:24.9 °C File :3Data :#6Date: 2024/7/9 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Jeff Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:50.1 % Time: 下午 02:46:29 Condition : EUT : M/N: Note : TX 927.25MHz FCC_part 15 RE-Class C_Above 1GHz_PK W6M22312-23185 Test Mode : Polarization: Vertical Distance: 3m 5 Vd.c. Power : Mk. Frequency (MHz) Reading (dBuV) Corr. factor (dB/m) Result (dBuV/m) Limit (dBuV/m) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment 2782.00043.5447.0674.00-30.46peak-3.52150226 3709.00055.8256.3774.00-18.18peak-0.55150101 *3709.00053.4854.0354.00-0.52AVG-0.55150101 *:Maximum data x:Over limit !:over margin Operator: Temperature:24.9 °C File :3Data :#3Date: 2024/7/9 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Jeff Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:50.1 % Time: 下午 02:44:20 Condition : EUT : M/N: Note : TX 927.25MHz FCC_part 15 RE-Class C_Above 1GHz_PK W6M22312-23185 Test Mode : Polarization: Horizontal Distance: 3m 5 Vd.c. Power : Mk. Frequency (MHz) Reading (dBuV) Corr. factor (dB/m) Result (dBuV/m) Limit (dBuV/m) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment *4636.00045.6542.3474.00-28.35peak3.31150162 5564.00044.3239.2274.00-29.68peak5.1015097 6490.75042.2333.1674.00-31.77peak9.07150110 7418.00041.6931.6874.00-32.31peak10.0115025 *:Maximum data x:Over limit !:over margin Operator: Temperature:24.9 °C File :3Data :#7Date: 2024/7/9 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Jeff Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:50.1 % Time: 下午 02:47:11 Condition : EUT : M/N: Note : TX 927.25MHz FCC_part 15 RE-Class C_Above 1GHz_PK W6M22312-23185 Test Mode : Polarization: Vertical Distance: 3m 5 Vd.c. Power : Mk. Frequency (MHz) Reading (dBuV) Corr. factor (dB/m) Result (dBuV/m) Limit (dBuV/m) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment *4636.00047.9144.6074.00-26.09peak3.31150125 5564.00044.9139.8174.00-29.09peak5.1015093 6490.75042.6133.5474.00-31.39peak9.07150219 7418.00042.4232.4174.00-31.58peak10.01150336 *:Maximum data x:Over limit !:over margin Operator: Temperature:24.9 °C File :3Data :#4Date: 2024/7/9 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Jeff Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:50.1 % Time: 下午 02:45:02 Condition : EUT : M/N: Note : TX 927.25MHz FCC_part 15 RE-Class C_Above 1GHz_PK W6M22312-23185 Test Mode : Polarization: Horizontal Distance: 3m 5 Vd.c. Power : Mk. Frequency (MHz) Reading (dBuV) Corr. factor (dB/m) Result (dBuV/m) Limit (dBuV/m) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment 8345.25041.2130.4674.00-32.79peak10.75150116 *9272.50042.9731.1774.00-31.03peak11.80150205 *:Maximum data x:Over limit !:over margin Operator: Temperature:24.9 °C File :3Data :#8Date: 2024/7/9 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Jeff Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:50.1 % Time: 下午 02:47:53 Condition : EUT : M/N: Note : TX 927.25MHz FCC_part 15 RE-Class C_Above 1GHz_PK W6M22312-23185 Test Mode : Polarization: Vertical Distance: 3m 5 Vd.c. Power : Mk. Frequency (MHz) Reading (dBuV) Corr. factor (dB/m) Result (dBuV/m) Limit (dBuV/m) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment 8345.25042.3431.5974.00-31.66peak10.75150108 *9272.50043.2931.4974.00-30.71peak11.8015027 *:Maximum data x:Over limit !:over margin Operator: Temperature:25.4 °C File :3Data :#1Date: 2024/7/10 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Gino Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:48.0 % Time: 下午 08:08:22 Condition : EUT : M/N: Note : RX 902.75MHz FCC_part 15 RE-Class B_Above 1GHz_PK W6M22312-23185 Test Mode : Polarization: Horizontal Distance: 3m 5 Vd.c. Power : Mk. Frequency (MHz) Reading (dBuV) Corr. factor (dB/m) Result (dBuV/m) Limit (dBuV/m) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment 2242.50029.8434.9574.00-44.16peak-5.11150113 *3971.50035.1434.4274.00-38.86peak0.7215023 *:Maximum data x:Over limit !:over margin RX Operator: Temperature:25.4 °C File :3Data :#3Date: 2024/7/10 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Gino Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:48.0 % Time: 下午 08:08:49 Condition : EUT : M/N: Note : RX 902.75MHz FCC_part 15 RE-Class B_Abov…

Text truncated - open the document above for the full version.

Test Report

8F, No.63, Juguang Rd, Zhonghe Dist, New Taipei City 235, Taiwan, R.O.C. Tel : ൅886-2-2225-8209 Fax: ൅886-2-2225-7523 www.aristotle.com.tw Antenna type:Directional RFA‐S3‐T283‐12626 Specifications Antenna Frequency range 902‐928 MHz Peak gain 6.96 dBi VSWR 1.5 : 1 Max. Polarization RHCP Impedance 50 Ω Connector N JACK Antenna cable Connector N PLUG / MMCX PLUG Cable Ø1.13 Length 500mm Environmental & Mechanical Characteristics Temperature ‐40°C to +85°C Humidity 95% @ 25°C VSWR 8F, No.63, Juguang Rd, Zhonghe Dist, New Taipei City 235, Taiwan, R.O.C. Tel : ൅886-2-2225-8209 Fax: ൅886-2-2225-7523 www.aristotle.com.tw Radiation Pattern 8F, No.63, Juguang Rd, Zhonghe Dist, New Taipei City 235, Taiwan, R.O.C. Tel : ൅886-2-2225-8209 Fax: ൅886-2-2225-7523 www.aristotle.com.tw Frequency (MHz) 3D Efficiency Avg. Gain Peak Gain 902.00 66.04 -1.80 6.75 915.00 67.43 -1.71 6.96 928.00 68.24 -1.66 6.87 Cable Loss Gain Table 8F, No.63, Juguang Rd, Zhonghe Dist, New Taipei City 235, Taiwan, R.O.C. Tel : ൅886-2-2225-8209 Fax: ൅886-2-2225-7523 www.aristotle.com.tw

Test Report

of Applicant: unitech Electronics Co., Ltd. Address: 5F., No. 136, Ln. 235, Baoqiao Rd. , Xindian Dist., New Taipei City , Taiwan Tested and Prepared by Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Report No.: W6M22312-23185-C-1 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E- mail: [email protected] 47 CFR PART 15 SUBPART C TEST REPORT for RM300 Plus UHF RFID Reader Module Model No.: RM300 Plus FCC ID: HLERM300PU Registration num ber: W6M22312-23185-C-1 FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 36 TABLE OF CONTENTS CERTIFICATION OF TEST REPORT ................................................................................................................................. 2 1 GENERAL INFORMATION ......................................................................................................................................... 2 1.1 NOTES ........................................................................................................................................................................... 2 1.2 TESTING LABORATORY .................................................................................................................................................. 3 1.3 DETAILS OF APPROVAL HOLDER .................................................................................................................................... 3 1.4 APPLICATION DETAILS ................................................................................................................................................... 3 1.5 GENERAL INFORMATION OF TEST ITEM ......................................................................................................................... 4 1.6 TEST STANDARDS .......................................................................................................................................................... 4 2 TECHNICAL TEST ........................................................................................................................................................ 5 2.1 SUMMARY OF TEST RESULTS ......................................................................................................................................... 5 2.2 TEST ENVIRONMENT ...................................................................................................................................................... 5 2.3 TEST EQUIPMENT LIST .................................................................................................................................................. 6 2.4 GENERAL TEST PROCEDURE .......................................................................................................................................... 7 3 TEST RESULTS (ENCLOSURE) ................................................................................................................................. 9 3.1 PEAK OUTPUT POWER (TRANSMITTER) ....................................................................................................................... 10 3.2 TRANSMITTER RADIATED EMISSIONS IN RESTRICTED BANDS ..................................................................................... 17 3.3SPURIOUS EMISSIONS (TX) ........................................................................................................................................... 18 3.4CARRIER FREQUENCY SEPARATION ............................................................................................................................ 20 3.5NUMBER OF HOPPING FREQUENCIES ........................................................................................................................... 22 3.6TIME OF OCCUPANCY (DWELL TIME) .......................................................................................................................... 24 3.720DB BANDWIDTH ...................................................................................................................................................... 28 3.8 RADIATED EMISSIONS FROM DIGITAL PART ................................................................................................................ 34 3.9 POWER LINE CONDUCTED EMISSION ............................................................... ............................................................ 35 Registration number: W6M22312-23185-C-1 FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Page 2 of 36 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. Laboratory disclaimer- 1. The test results of this test report relate exclusively to the item tested as specified in 1.5. 2. The test report may only be reproduced or published in full. 3. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Services(Taiwan) Co., Ltd. 4. Antenna gain is provided by applicant and laboratory issue relevant data and results. Tester: August 21, 2024 Rick Chen Date WTS-Lab. Name Signature Technical responsibility for area of testing: August 21, 2024…

Text truncated - open the document above for the full version.

Test Setup Photos

Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 15 of 17 Set Up Photo of Radiated Emission Below 1GHz Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 16 of 17 Above 1GHz Registration number: W6M22312-23185-FCC FCC ID: HLERM300PU Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 17 of 17

Contact Information

Applicant

Ben Chiang
[email protected]886-2-8912-1122Fax: 886-2-8912-1391

Technical Contact

Worldwide Testing Services (Taiwan) Co., Ltd.Kevin Wang
[email protected]886-2-6606-8877

6F., No.58, Lane 188, Ruey Kuand Rd., Neihu · Taiwan

Non-Technical Contact

Worldwide Testing Services (Taiwan) Co., Ltd.Chieh Tseng
[email protected]886-2-6606-8877

Test Firm

Worldwide Testing Services (Taiwan) Co., Ltd.Rex Kao
[email protected]886-2-6606-8877Fax: 886-2-6606-8879

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.75 MHz - 927.25 MHz570.00 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna's as listed in this application must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Unitech Electronics Co., Ltd.

RG768 Plus gun grip - FCC ID HLERG768PU - Unitech Electronics Co., Ltd.
HLERG768PU

RG768 Plus gun grip

Jul 29, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
HLEEA530BWNWU

Rugged Handheld Computer

Feb 16, 2026

Equipment Class

DTS - Digital Transmission System
HLEEA530BWNW

Rugged Handheld Computer

Feb 16, 2026

Equipment Class

6XD - 15E 6 GHz Low Power Indoor Client
RP300 UHF RFID Mobile Reader - FCC ID HLERP300BU - Unitech Electronics Co., Ltd.
HLERP300BU

RP300 UHF RFID Mobile Reader

Nov 24, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Rugged Tablet - FCC ID HLERT112BWN - Unitech Electronics Co., Ltd.
HLERT112BWN

Rugged Tablet

Jan 14, 2024

Equipment Class

DTS - Digital Transmission System