Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
CIRRONET, INC. © "ZMN2400 Design Documentation ", AP, 10/1/07. 1 of 5 ZMN2400 Series Radio Module ZMN2400HP, High Power Manual Preliminary Cirronet, Inc. CIRRONET, INC. © "ZMN2400 Design Documentation ", AP, 10/1/07. 2 of 5 Important Regulatory Information Cirronet Zigbee High Power - FCC ID: HSW-Z2400HP IC: 4492A-Z2400HP THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS. (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. FCC User Information “NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.” Warning: Changes or modifications to this device not expressly approved by Cirronet Inc. could void the user’s authority to operate the equipment. RF Exposure In accordance with FCC requirements of human exposure to radiofrequency fields, the radiating element shall be installed such that a minimum separation distance of 20cm shall be maintained from the user and/or general population. The transmitter module may not be co-located with any other transmitter or antenna. Industry Canada This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l'interférence canadienne causant des règlements d'équipement. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée. CIRRONET, INC. © "ZMN2400 Design Documentation ", AP, 10/1/07. 3 of 5 Hardware Specifications Radio Specifications Operating Band 2400-2475 MHz Radio Type Direct Sequence (DTS), IEEE 802.15.4 PHY layer Channel Bit Rate 250 Kbps Channel Chipping Rate 2 Mcps Modulation MSK with Raised Cosine Filtering Certification Type DTS device per FCC 15.247 and ETS 300-328 RF power +18 dBm typical, +15 dBm minimum Receiver Sensitivity -98 dBm typical, -95 dBm minimum Link Margin 110 dB (approximately 3 Km Line of Sight propagation) Adjacent Ch. Rejection >39 dB with jammer @ 5 MHz offset Spurious Output Per FCC 15.247 and ETS 300-328 General Input Voltage 5.5 volts minimum, 6 volts nominal, 15 volts maximum Current Consumption 70 mA typical operating, 180 mA peak (transmit) Operating Temp Range -40 C to + 70 C Humidity 95% Non-condensing RF Connector Reverse SMA Host Connector Male DB-9 (Amp 747840-3) Power Connector CUI Stack PJ-002A Theory of Operation The Cirronet ZMN2400 Series radio modules utilizes the IEEE 802.15.4 standard ZigBee Physical layer hardware for wireless low data rate monitoring and control applications. The application of the ZMN2400 Series in a wireless network for data collection in industrial monitoring and control. Block Diagram in Figure 1 The ZMN2400 Series radio modules consist of an RF transceiver and a microprocessor in one chip. The RF transceiver receives data and commands from the microprocessor as well as the clock required by the RF transceiver. The Block diagrams in Figure 1 shows both the ZMN2400 (Low Power) and the ZMN2400HP (High Power). They are the same with the exception of T/R switches and a PA (Power Amp) and a LNA (Low Noise Amp) in the high power version. The output power is +16 dBm for the high power and 0 dBm for the low power ZigBee Transceivers. CIRRONET, INC. © "ZMN2400 Design Documentation ", AP, 10/1/07. 4 of 5 ZigBee RF Transceiver and Processor S P D T S P D T LPF PA LNA BPF ZigBee ZMN2400HP High Power Module Figure 1 CIRRONET, INC. © "ZMN2400 Design Documentation ", AP, 10/1/07. 5 of 5 ZMN2400 Frequency Selection The ZMN2400 is not frequency agile during run-time, but it can select an unoccupied portion of the spectrum at startup. The ZMN-2400 series uses a set of channels as defined by the IEEE 802.15.4 / ZigBee standards which span a range from 2405 to 2480 MHz with 5 MHz spacing between channels: Center Frequency (MHz) Nominal Occupied BW ZigBee Channel Designator 2405 2402.5-2407.5 11 2410 2407.5-2412.5 12 2415 2412.5-2417.5 13 2420 2417.5-2422.5 14 2425 (default) 2422.5-2427.5 15 2430 2427.5-2432.5 16 2435 2432.5-2437.5 17 2440 2437.5-2442.5 18 2445 2442.5-2447.5 19 2450 2447.5-2452.5 20 2455 2452.5-2457.5 21 2460 2457.5-2462.5 22 2465 2462.5-2467.5 23 2470 2467.5-2472.5 24 2475 2472.5-2477.5 25 2480 NOT USED 2477.5-2482.5 26 The channel mask is the name used to describe the list of frequency channels that a ZMN-2400 can use. The defaul…
Text truncated - open the document above for the full version.
AGENCY AGREEMENT Federal Communications Commission P.O. Box 429 Columbia, MD 21045 Date: June, 30 2004 Gentlemen: I hereby appoint U.S. Technologies, Inc. to act as our agent in the preparation of an application for equipment authorization of ZMN2400HP, FCC ID: HSW-Z2400HP under Part 15 of the FCC Rules and Regulations. I certify that Exhibits _(Leave this blank for US Tech to fill in)_ properly describe the device or system for which authorization is sought, that the information described in the User's Manual will be provided with each item manufactured or distributed by the applicant, and that the labels described by Exhibit _(Leave this blank for US Tech to fill in)_ will be affixed to each item manufactured or distributed by the applicant. I further certify that appropriate arrangements have been made to assure that production units of this equipment bearing the name and FCC IDENTIFIER listed in this application will continue to comply with the Commission's requirements. I further certify by signature below that no party (per 47 CFR 1.2002(b)) to the application is subject to a denial of Federal benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This appointment also includes the authority to complete FCC Form 731 on our behalf and sign the application as an authorized agent. Al Patrick,Date: August, 17 2007 Sr. Compliance EngineerAl Patrick Cirronet [email protected] 5375 Oakbrook Parkway Norcross, GA 30093 678 684 2000 ext. 138
CONFIDENTIALITY REQUEST Federal Communications Commission Date: 8-20-07 Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: Cirronet respectfully requests confidentiality of certain materials provided with the submission of the ZigBee Module under FCC ID: HSW-Z2400HP in accordance with FCC Regulations 0.459. The confidentiality request applies to the (1) schematic diagrams, (2) detailed block diagrams and (3) detailed operational descriptions, that may be contained in this filing. The ZigBee Module has been developed at considerable effort and expense by Cirronet. These items are considered as Trade Secrets and therefore public access to the proprietary material could possible result in duplication of equipment that could severely damage the company's business advantage. I appreciate your assistance in this matter. Sincerely, Al Patrick Al Patrick Sr. Compliance Engineer Cirronet Inc. 5375 Oakbrook Parkway Norcross, GA 30093 USA TEL: 678 684 2000 FAX: 678 684 2001 www.cirronet.com [email protected]
3505 Francis Circle Alpharetta, GA 30004 PH: 770-740-0717 Fax: 770-740-1508 www.ustech-lab.com September 28, 2007 ATCB Mr. Doug Noble RE: Cirronet FCC ID: HSW-ZMN2400HP Mr. Noble, The following is our response to your comments of 9/21/2007. I have included your written questions and provide an answer to each. I have a few comments on this Application. 1. Please use the FCC guidelines for testing Spectral Power Density. I have attached the guideline PDF. Please retest and revise test report to include testing with correct procedures for SPD test. Corrected and Uploaded 2. Please provide RF Exposure MPE exhibit to support 20 cm statement in user manual. Uploaded Thank you for your attention to this matter. Please contact me with any further questions. Sincerely, Louis A. Feudi Vice President of Operations and Engineering
Louis A. Feudi From: Al Patrick [[email protected]] Sent: Monday, August 20, 2007 2:05 PM To: [email protected] Subject: FW: ZMN2430HP Module certification Importance: High Page 1 of 4Message 9/19/2007 Lou, below is the conversations with Joe Dichoso at the FCC on the on the shape and length of the micro strip lines. Now you have the whole picture. Al Patrick Sr. Compliance Engineer Cirronet Inc. 3079 Premiere Parkway, Suite 140 Duluth, GA 30097 USA Tel: 678 684 2000 Fax: 678 684 2001 [email protected] www.cirronet.com From: Mark Tucker Sent: Monday, August 13, 2007 11:48 AM To: Al Patrick Subject: ZMN2430HP Module certification Al, Here is the whole stream regarding the multiple Microstrip testing scheme we’ve used on the ZMN2430HP. Start at the bottom and work up. Mark From: Joe Dichoso [mailto:[email protected]] Sent: Thursday, March 09, 2006 10:19 AM To: Mark Tucker Cc: Paul Maziarczyk; Tim Cutler; Steven Dayhoff; Joe Dichoso Subject: RE: Tracking number 539509 Mark, I took another quick look. The only other issue that needs elaboration is the OEM instructions on the shape and length of the micro strip line and what tests you will perform to ensure that the range of installations would ensure compliance. You can prescan different shapes and sizes to check for compliance. If the only construction is a straight microstrip line with various lengths the OEM instructions should make it clear and testing easier. -Joe *** Non-Public: For Internal Use Only *** -----Original Message----- From: Mark Tucker [mailto:[email protected]] Sent: Thursday, March 09, 2006 10:01 AM To: Joe Dichoso Cc: Paul Maziarczyk; Tim Cutler Subject: RE: Tracking number 539509 Joe, Thanks for the reply. Yea, I knew this proposal might be a little involved and take a few days to resolve. I just wanted to make sure you had it in hand. Let me know if any of my points aren’t clear or need further elaboration. Regards, Mark From: Joe Dichoso [mailto:[email protected]] Sent: Thursday, March 09, 2006 9:45 AM To: Mark Tucker Subject: RE: Tracking number 539509 Mark, Yes, it was received. A quick look at it looks like it needs discussion with several staff so this one may take some time. Joe -----Original Message----- From: Mark Tucker [mailto:[email protected]] Sent: Wednesday, March 08, 2006 6:07 PM To: Joe Dichoso Subject: Tracking number 539509 Joe, Sorry to bother you about a housekeeping item, but I need to make sure a reply I submitted to your lab-help web site made it into the system and I didn’t know who else to contact to find out. I submitted a question to the lab-help site early last week and received a tracking number of 539509. OET replied within two days asking for more detail on a few of my points. I then replied to those questions using the “reply comments” section of the web site last Friday (3/3). I haven’t heard a reply since then and just wanted to make sure my reply comments were actually received. It’s fine if you’re still chewing over the answer – I just wanted to make sure my reply made it to OET’s office. Thanks, Mark From: Bessie Bordenave [mailto:[email protected]] Page 2 of 4Message 9/19/2007 Sent: Thursday, February 23, 2006 3:08 PM To: Mark Tucker Subject: RE: Modular Approval for a 15.247 device soldered on OEM's support board You should submit this inquiry through our Knowledge Database System at: www.fcc.gov/labhelp. After submitting the inquiry, you will receive a tracking number for future use concerning this inquiry. We (Cirronet) would like to obtain module approval for a Zigbee module coming out later this year. This module will be designed to be compliant as a DTS under 15.247. The module itself is very small – roughly 1 inch by 0.5 inch - and is designed to be soldered directly on to an OEM’s support board. Per the modular approval rules, our module is designed to have the following features: 1) RF shield is provided around the module 2) All data/modulation inputs are buffered 3) The module has its own internal power regulation 4) The module employs a “unique” antenna connection – a solder pad on the back side of the board that must be soldered to the OEM’s support board 5) The module would be tested in the same configuration as the OEM would use it without added shielding or other emissions-reducing circuitry added 6) The module would have the appropriate FCC ID on the top shield 7) These modules are only sold to OEM industrial monitoring and control customers. A detailed operating manual is included with the sale of each module that outlines correct usage of the module. 8) Standard SAR measurements/calculations will be made as part of the testing. Appropriate MPE warnings/alerts will be in the manual. Items 4 and 5 require more explanation. Given the module’s small size, the OEM customer will have to solder it down directly on the PWB of their product. Connection between the RF connection pin on our module and their external antenna will be made by means of a micro strip line on their PWB leading into a MMXC antenna connector. No additional matching or filtering will be required between the module and the antenna connector – just the micro strip line. Given the intended use of the module, we propose to test it in exactly the same fashion at the lab. The module will be soldered on to a support PWB with a section of 50 micro strip transmission line between the module and the antenna connector. The various antennas we want to certify with the module will then be attached to the connector through a coaxial cable for spurious emissions testing. The OEM customer will take the same approach with the module in their product as we did in our testing. They will solder down our module onto their support board and provide a short section of micro strip to connect the RF pin of our module to their external antenna. We will specify the design and construction of the 50 ohm micro strip line on the OEM’s support board in the manual for the module. [This is essentially n…
Text truncated - open the document above for the full version.
Page 1 of 2© Cirronet 2003 Cirronet, Inc.Tel: 678 684 2000 3079 Premiere Parkway Fax: 678 684 2001 Duluth, Georgia 30097 USA Date: 8/16/2007 Reference: FCC DA 00-1407 PART 15 UNLICENSED MODULAR TRANSMITTER APPROVAL Cirronet ZMN2400HP ZigBee Module FCC ID: HSW-Z2400HP Per FCC DA 00-1407, Cirronet’s ZigBee modules are compliance with the requirements listed below. 1. The modular transmitter must have its own RF shielding. Cirroent’s ZigBee Module has shielding as required. 2. The modular transmitter must have buffered modulation/data inputs. Cirroent’s ZigBee Module has buffered modulation and data inputs. 3. The modular transmitter must have its own power supply regulation. Cirronet’s ZigBee Module has its own internal regulator. 4. The modular transmitter must comply with the antenna requirements of Section 15.203 and 15.204(c). Cirronet’s ZigBee Module output is through a set of connections which are like a ball grid array and once soldered to a PC board the connects are not accessible. Without a support PC board the module is unusable. 5. The modular transmitter must be tested in a stand-alone configuration, i.e., the module must not be inside another device during testing. Cirronet’s ZigBee Module was tested on a support PC board designed to meet the requirements of modular approval. Complete open. 6. The modular transmitter must be labeled with its own FCC ID number Cirronet’s ZigBee Module is design as a OEM module. The ZigBee Page 2 of 2© Cirronet 2003 Module will be labeled and instructions given to the OEM customer for FCC label requirements. 7. The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter. An Integration Guide is provided with FCC compliance information. 8. The modular transmitter must comply with any applicable RF exposure requirements. An Integration Guide is also provides FCC MPE warnings per antenna types that are used. Al Patrick Sr. Compliance Engineer Cirronet Inc. 3079 Premiere Parkway, Suite 140 Duluth, GA 30097 USA TEL: 678 684 2000 FAX: 678 684 2001 www.cirronet.com [email protected]
ZMN2400HP top with shield
Label Placement FCC label
ZMN2400HP top inside FCC ID: HSW- Z2400HP ZMN2400HP bottom FCC ID: HSW-Z2400HP
Page 1 of 94 Cirronet Corporation FCC Part 15, Certification Application ZMN2400HP UST Project: 07-0207 Issue Date: August 17, 2007 3505 Francis Circle Alpharetta, GA 30004 PH: 770-740-0717 Fax: 770-740-1508 www.ustech-lab.com Page 2 of 94 I certify that I am authorized to sign for the manufacturer and that all of the statements in this report and in the Exhibits attached hereto are true and correct to the best of my knowledge and belief: UNITED STATES TECHNOLOGIES, INC. (AGENT RESPONSIBLE FOR TEST): By: Name: Louis A. Feudi Title: VP / Operations & Engineering Date: August 17, 2007 Cirronet Corporation 5375 Oakbrook Parkway Norcross, GA 30093 By: Name: Title: Date: This report shall not be reproduced except in full. This report may be copied in part only with the prior written approval of U.S. Technologies. The results contained in this report are subject to the adequacy and representative character of the sample provided. 3505 Francis Circle Alpharetta, GA 30004 PH: 770-740-0717 Fax: 770-740-1508 www.ustech-lab.com FCC ID: HSW-Z2400HP Page 3 of 94 MEASUREMENT/TECHNICAL REPORT COMPANY NAME: Cirronet Corporation MODEL: ZMN2400HP FCC ID: HSW- Z2400HP DATE: August 13, 2007 This report concerns (check one): Original grant X Class II change_____ Equipment type: 2.4 GHz Zigbee Radio Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? yes_____ No X If yes, defer until:_________________ date N.A. agrees to notify the Commission by N.A. date of the intended date of announcement of the product so that the grant can be issued on that date. Report prepared by: United States Technologies, Inc. 3505 Francis Circle Alpharetta, GA 30004 Phone Number: (770) 740-0717 Fax Number: (770) 740-1508 FCC ID: HSW-Z2400HP Page 4 of 94 TABLE OF CONTENTS AGENCY AGREEMENT / CONFIDENTIALITY REQUEST SECTION 1 GENERAL INFORMATION 1.1 Product Description 1.2 Related Submittal(s) SECTION 2 TESTS AND MEASUREMENTS 2.1 Configuration of Tested EUT 2.2 Test Facility 2.3 Test Equipment 2.4 Modifications 2.5 Antenna Description 2.6 Peak Power (Bandedge Antenna Conducted at Antenna Terminal) 2.7 Antenna Conducted Spurious Emissions 2.8 Peak Radiated Spurious Emissions and Average Radiated Spurious Emissions 2.9 Module Comparison Data 2.10 Bandedge Requirements 2.11 Minimum 6 dB Bandwidth 2.12 Average Time of Occupancy per Channel 2.13 Power Line Conducted for Digital Device & Receiver 2.14 Power Line Conducted Emissions for Transmitter 2.15 Radiated Emissions for Digital Device & Receiver 2.16 Peak Power Spectral Density SECTION 3 LABELING INFORMATION SECTION 4 BLOCK DIAGRAM(S)/ SCHEMATIC(S) SECTION 5 PHOTOGRAPHS SECTION 6 THEORY OF OPERATION SECTION 7 USER'S MANUAL FCC ID: HSW-Z2400HP Page 5 of 94 LIST OF FIGURES AND TABLES FIGURES 1) Test Configuration 2) Photograph(s) for Spurious and Conducted Emissions 3) Peak Output Power 4) Conducted Spurious Emissions 5) Peak Radiated Spurious Emissions 6) Bandedge Compliance Antenna Conducted 7) 6 dB Bandwidth 8) Peak Power Spectral Density TABLES 1) EUT and Peripherals 2) Test Instruments 3) Peak Power Output 4) Peak Radiated Spurious Emissions 5) Average Radiated Spurious Emissions 6) 6 dB Bandwidth 7) Conducted Emissions 8) Radiated Emissions for Digital Device and Receiver FCC ID: HSW-Z2400HP Page 6 of 94 SECTION 1 GENERAL INFORMATION FCC ID: HSW-Z2400HP Page 7 of 94 GENERAL INFORMATION 1.1 Product Description The Equipment Under Test (EUT) is a Cirronet Corporation, Model ZMN2400HP modular 2.4 GHz spread spectrum transceiver. The EUT will be used with three (3) antennas via a non standard connector. FCC ID: HSW-Z2400HP Page 8 of 94 1.2 Related Submittal(s)/Grant(s) The EUT will be used to send/receive data. The transceiver presented in this report will be used with other like transceivers: The EUT is subject to the following authorizations: a) Certification as a transceiver (modular approval) b) Verification as a digital device The information contained in this report is presented for the certification & verification authorization(s) for the EUT. The manufacturer desires to seek a modular approval on this device. FCC ID: HSW-Z2400HP Page 9 of 94 SECTION 2 TESTS AND MEASUREMENTS FCC ID: HSW-Z2400HP Page 10 of 94 TEST AND MEASUREMENTS 2.1 Configuration of Tested System The sample was tested per ANSI C63.4, Methods of Measurement from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz (2003). Conducted and radiated emissions data were taken with the test receiver or spectrum analyzer's resolution bandwidth adjusted to 9 kHz and 120 kHz, respectively. All measurements are peak unless stated otherwise. The video filter associated with the spectrum analyzer was off throughout the evaluation process. Bock diagrams of the tested systems are shown in Figures 1a and 16. Test configuration photographs for spurious and fundamental emissions are shown in Figure 2a -g. The sample used for testing was received by U.S. Technologies on July 17, 2007 in good condition. 2.2 Test Facility Testing was performed at US Tech's measurement facility at 3505 Francis Circle, Alpharetta, GA. This site has been fully described and registered with to the FCC, and under designation number US5117. Additionally this site has also been fully described and submitted to Industry Canada (IC), and has been approved under file number 2982A-1. 2.3 Test Equipment Table 2 describes test equipment used to evaluate this product. 2.4 Modifications No modifications were made by US Tech, to bring the EUT into compliance with FCC Part 15, Class B Limits for the transmitter portion of the EUT or the Class B Digital Device Requirements. FCC ID: HSW-Z2400HP Page 11 of 94 FIGURE 1 TEST CONFIGURATION Power Supply #1 Laptop Coordinator Module (EUT) Power Supply #2 1m U 1m U 6’ U 120 VAC 60 Hz 6’ U 120 VAC 60 Hz 1m U To Antenna Varied from 0.2 to 1 m S FCC ID: HSW-Z2400HP 12 TABLE 1 Test Date: August 8, 2007 UST Project: 07-0207 Customer: Cirronet Corporation Model: ZMN2400HP EUT and Peripherals PERIPHERAL …
Text truncated - open the document above for the full version.
Test Date: August 8, 2007 UST Project: 07-0207 Customer: Cirronet Corporation Model: ZMN2400HP FIGURE 2a1 Photograph(s) for Spurious Emissions Corner Antenna (Front) Test Date: August 8, 2007 UST Project: 07-0207 Customer: Cirronet Corporation Model: ZMN2400HP FIGURE 2a2 Photograph(s) for Spurious Emissions Corner Antenna (Back) Test Date: August 8, 2007 UST Project: 07-0207 Customer: Cirronet Corporation Model: ZMN2400HP FIGURE 2b1 Photograph(s) for Spurious Emissions Omni Antenna (Front) Test Date: August 8, 2007 UST Project: 07-0207 Customer: Cirronet Corporation Model: ZMN2400HP FIGURE 2b2 Photograph(s) for Spurious Emissions Omni Antenna (Back) Test Date: August 8, 2007 UST Project: 07-0207 Customer: Cirronet Corporation Model: ZMN2400HP FIGURE 2c1 Photograph(s) for Spurious Emissions Patch Antenna (Front) Test Date: August 8, 2007 UST Project: 07-0207 Customer: Cirronet Corporation Model: ZMN2400HP FIGURE 2c2 Photograph(s) for Spurious Emissions Patch Antenna (Back) Test Date: August 8, 2007 UST Project: 07-0207 Customer: Cirronet Corporation Model: ZMN2400HP FIGURE 2d Photograph(s) for Conducted Emissions
3505 Fancis Circle · Alphareatta, Georgia · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 46.00 mW |
LBMA0ZZ2NR
Equipment Class
DTS - Digital Transmission SystemCommunication Module
Equipment Class
DTS - Digital Transmission System
Type 2EG BLE Module
Equipment Class
DTS - Digital Transmission System
Wireless 2.4 GHz Industrial Transceiver
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Wireless Medical Telemetry Service Radio Module
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter