Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Date of Grant
Dec 06, 2006
Application Purpose
Original Equipment
Date of Application
Dec 06, 2006
Equipment Note
Vehicle Entry System Receiver
Frequency Range
312.15000000 - 312.15000000
Company
Denso Corporation
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Product Description This system is mainly used for locking or unlocking the doors of the vehicle. The transmitter sends a radio wave signal while the button is pushed. The receiver becomes active in response to the signal from the transmitter. NOTE This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

External Photos

DENSO CORPORATION Remote Keyless Entry System (Receiver) FCC ID: HYQ13CZA IC: 1551A-13CZA External Photo Top Bottom DENSO CORPORATION Remote Keyless Entry System (Receiver) FCC ID: HYQ13CZA IC: 1551A-13CZA External Photo Left Right DENSO CORPORATION Remote Keyless Entry System (Receiver) FCC ID: HYQ13CZA IC: 1551A-13CZA External Photo Rear Front

ID Label/Location Info

7. Marking location and layout Scale: free Note. Compliance statement of marking will not be changed. But marking layout, size and other indications maybe changed. Fig. Marking location and layout of Receiver

Internal Photos

DENSO CORPORATION Remote Keyless Entry System (Receiver) FCC ID: HYQ13CZA Internal Photos Component Side Solder Side

Test Report

Test report No. : 27CE0103-HO-D-1 Page : 8 of 12 Issued date : November 21, 2006 Revised date : November 30, 2006 FCC ID : HYQ13CZA UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 MF060b(14.06.06) APPENDIX 1: Photographs of test setup Radiated Emission Front Rear Test report No. : 27CE0103-HO-D-1 Page : 9 of 12 Issued date : November 21, 2006 Revised date : November 30, 2006 FCC ID : HYQ13CZA UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 MF060b(14.06.06) Worst Case Position (Horizontal : Z-axis/ Vertical: Y-axis) X-axis Y-axis Z-axis

Test Report

Test report No. : 27CE0103-HO-D-1 Page : 10 of 12 Issued date : November 21, 2006 Revised date : November 30, 2006 FCC ID : HYQ13CZA UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 MF060b(14.06.06) APPENDIX 2: Data of EMI test Radiated Emission (below 1GHz) DATA OF RADIATED EMISSION TEST UL Apex Co., Ltd. Head Office EMC Lab. No.3 Semi Anechoic Chamber Date : 2006/11/11 13:18:14 Company : DENSO CORPORATIONReport No.:27CE0103-HO Kind of EUT: Remote Keyless Entry System (Receiver) Power:DC 13.2V Model No.: 13CZA Temp./Humi.:25deg.C. / 57% Serial No.: No.2 Operator:Mitsuru fujimura Mode / Remarks : Rx 312.15MHz Hori(Z-axis) Vert(Y-axis) LIMIT : FCC Part15 Subpart B (3m)/USA, below1GHz:QP Except for the data below : adequate margin data below the limits. CHART:WITH FACTOR ANT TYPE:-30MHz LOOP,30-300MHz BICONICAL,300MHz-1000MHz LOGPERIODIC,1000MHz- HORN CALCULATION:RESULT = READING + ANT FACTOR + LOSS(CABLE+ATTEN.) - GAIN(AMP) Frequency[Hz] [dBuV/m]<< QP DATA >> Horizontal Vertical Horizontal Vertical 30M 1G 50M 70M 100M200M300M500M700M 0 10 20 30 40 50 60 70 80 FrequencyReading DET AntennaLoss& LevelAngleHeight Polar. LimitMargin Comment FrequencyReading DET FactorGain LevelAngleHeight Polar. LimitMargin Comment [MHz] [dBuV] DET [dB/m][dB][dBuV/m][Deg][cm] Polar. [dBuV/m][dB] Comment 37.68026.2 QP 15.3-25.016.5309100Vert.40.023.5 37.68025.0 QP 15.3-25.015.3200300Hori.40.024.7 301.45228.6 QP 14.5-22.320.831223Vert.46.025.2 301.46330.4 QP 14.5-22.322.6208100Hori.46.023.4 312.15022.2 QP 14.9-22.214.90100Vert.46.031.1 312.15022.3 QP 14.9-22.215.0208100Hori.46.031.0 339.14024.5 QP 15.9-22.118.331223Vert.46.027.7 339.15024.1 QP 15.9-22.117.9208100Hori.46.028.1 Test report No. : 27CE0103-HO-D-1 Page : 11 of 12 Issued date : November 21, 2006 Revised date : November 30, 2006 FCC ID : HYQ13CZA UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 MF060b(14.06.06) Radiated Emission (above 1GHz) DATA OF RADIATED EMISSION TEST UL Apex Co., Ltd. Head Office EMC Lab. No.3 Semi Anechoic Chamber Date : 2006/11/11 14:56:56 Company : DENSO CORPORATIONReport No.:27CE0103-HO Kind of EUT: Remote Keyless Entry System (Receiver) Power:DC 13.2V Model No.: 13CZA Temp./Humi.:25deg.C. / 57% Serial No.: No.2 Operator:Mitsuru Fujimura Mode / Remarks : Rx 312.15MHz Hori(Y-axis) Vert(Y-axis) LIMIT : FCC Part15 Subpart B (3m)/USA, above1GHz:PK FCC Part15 Subpart B (3m)/USA, above1GHz:AV CHART:WITH FACTOR ANT TYPE:-30MHz LOOP,30-300MHz BICONICAL,300MHz-1000MHz LOGPERIODIC,1000MHz- HORN CALCULATION:RESULT = READING + ANT FACTOR + LOSS(CABLE+ATTEN.) - GAIN(AMP) Frequency[Hz] [dBuV/m]<< AV/PEAK DATA >> Horizontal Vertical Horizontal Vertical 1G 2G 0 10 20 30 40 50 60 70 80 90 FrequencyReading DET AntennaLoss& LevelAngleHeight Polar. LimitMargin Comment FrequencyReading DET FactorGain LevelAngleHeight Polar. LimitMargin Comment [MHz] [dBuV] DET [dB/m][dB][dBuV/m][Deg][cm] Polar. [dBuV/m][dB] Comment 1205.80044.9 PK 25.9-33.237.61100Hori.73.936.4 1205.80032.6 AV 25.9-33.225.31100Hori.53.928.6 1205.80042.5 PK 25.9-33.235.21100Vert.73.938.8 1205.80032.6 AV 25.9-33.225.31100Vert.53.928.6 1257.40041.7 PK 25.9-32.934.71100Hori.73.939.2 1257.40031.8 AV 25.9-32.924.81100Hori.53.929.1 1257.40031.7 AV 25.9-32.924.71100Vert.53.929.2 1257.40044.0 PK 25.9-32.937.01100Vert.73.936.9 1507.25041.3 PK 26.1-32.235.21100Hori.73.938.7 1507.25030.7 AV 26.1-32.224.61100Vert.53.929.3 1507.25042.3 PK 26.1-32.236.21100Vert.73.937.7 1507.25030.8 AV 26.1-32.224.71100Hori.53.929.2 Test report No. : 27CE0103-HO-D-1 Page : 12 of 12 Issued date : November 21, 2006 Revised date : November 30, 2006 FCC ID : HYQ13CZA UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 MF060b(14.06.06) APPENDIX 3: Test instruments Control No. Instrument Manufacturer Model No Test Item Calibration Date * Interval(month) MAEC-03 Anechoic Chamber TDK Semi Anechoic Chamber 3m RE 2006/03/03 * 12 MOS-12 Thermo- Hygrometer Custom CTH-180 RE 2006/01/19 * 24 MSA-04 Spectrum Analyzer Agilent E4448A RE 2006/06/02 * 12 MDPS-05 DC Power Supply KENWOOD TMI PW8-3ATP RE Pre Check MCB-03 Car Battery YUASA 40B19L RE Pre Check MBA-03 Biconical Antenna Schwarzbeck BBA9106 RE 2006/01/29 * 12 MLA-03 Logperiodic Antenna Schwarzbeck USLP9143 RE 2006/01/29 * 12 MCC-51 Coaxial cable UL Apex - RE 2006/03/11 * 12 MAT-30 Attenuator(6dB) TME UFA-01 RE 2006/03/11 * 12 MPA-13 Pre Amplifier SONOA INSTRUMENT 310 RE 2006/03/25 * 12 MHA-20 Horn Antenna 1- 18GHz Schwarzbeck BBHA9120D RE 2006/04/06 * 12 MCC-56 Microwave Cable 1G-26.5GHz Suhner SUCOFLEX104 RE 2006/04/15 * 12 MPA-11 MicroWave System Amplifier Agilent 83017A RE 2006/03/27 * 12 MSTW-14 EMI measurement program TSJ TEPTO-DV RE 2006/06/19 * 60 MJM-07 Measure PROMART SEN1955 RE - The expiration date of the calibration is the end of the expired month. All equipment is calibrated with traceable calibrations. Each calibration is traceable to the national or international standards. Test Item: RE: Radiated emission

Test Setup Photos

Test report No. : 27CE0103-HO-D-1 Page : 8 of 12 Issued date : November 21, 2006 Revised date : November 30, 2006 FCC ID : HYQ13CZA UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 MF060b(14.06.06) APPENDIX 1: Photographs of test setup Radiated Emission Front Rear Test report No. : 27CE0103-HO-D-1 Page : 9 of 12 Issued date : November 21, 2006 Revised date : November 30, 2006 FCC ID : HYQ13CZA UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 MF060b(14.06.06) Worst Case Position (Horizontal : Z-axis/ Vertical: Y-axis) X-axis Y-axis Z-axis

Contact Information

Applicant

Keijiro Kumagai(Manager)
[email protected]81-566-55-9563Fax: 81-566-25-4546

Technical Contact

UL ApexNaoki Sakamoto
[email protected]81-596-24-8116

4383-326 Asamo-cho · Ise-shi, Mie-ken · Japan

Non-Technical Contact

UL ApexYoshiko Mizuta
[email protected]81-596-24-8116

Test Firm

UL Japan, Inc.Mitsuru Fujimura
[email protected]81-596-24-8116Fax: 81-596-24-8124

Technical Specifications

#Rule PartsFrequency RangePower Output
115B312.15 MHz - 312.15 MHz-
Confidentiality
Long Term

Other Applications from Denso Corporation

HYQDNILR001

LiDsEYE

Aug 04, 2026

Equipment Class

JAB - Part 15 Class B Digital Device
HYQDNMWR020

Millimeter Wave Radar Sensor

Mar 27, 2026

Equipment Class

VRD - Part 95 Vehicular Radar Systems
HYQDNMWR021

Millimeter Wave Radar Sensor

Mar 10, 2026

Equipment Class

VRD - Part 95 Vehicular Radar Systems
HYQ23ABR

Remote Keyless Entry System and TPMS (Receiver)

Mar 05, 2026

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
HYQDNMWR018RAM

Millimeter Wave Radar Sensor

Oct 10, 2024

Equipment Class

VRD - Part 95 Vehicular Radar Systems