FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Proxim Wireless Corporation/
  3. HZB-MP50XXSU

HZB-MP50XXSUTSUNAMI MP.11 SUBSCRIBER UNIT

Proxim Wireless Corporation
TSUNAMI MP.11 SUBSCRIBER UNIT - FCC ID HZB-MP50XXSU - Proxim Wireless Corporation
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Oct 24, 2007
Application Purpose
Original Equipment
Date of Application
Oct 23, 2007
Equipment Note
TSUNAMI MP.11 SUBSCRIBER UNIT
Frequency Range
5500.00000000 - 5700.00000000
Company
Proxim Wireless Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—
β†—
β†—
β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Parts List/Tune Up Info

β†—

RF Exposure Info

β†—

Test Report

β†—
β†—
β†—
β†—

Test Setup Photos

β†—
β†—
β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Tsunami MP.11 Safety and Regulatory Compliance Guide Model 5012-SUI Model 5054-SUI Model 5012-SUR (May 2007) IMPORTANT! Visit http://support.proxim.com for the latest safety and regulatory compliance information for this product. Safety and Regulatory Information 2 Copyright Β© 2007 Proxim Wireless Corporation. All rights reserved. Covered by one or more of the following U.S. patents: 5,231,634; 5,875,179; 6,006,090; 5,809,060; 6,075,812; 5,077,753. This user’s guide and the software described in it are copyrighted with all rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means without the written permission of Proxim Wireless Corporation. Trademarks Tsunami, Proxim, and the Proxim logo are trademarks of Proxim Wireless Corporation. All other trademarks mentioned herein are the property of their respective owners. Tsunami MP.11 Models 5012-SUI, 5054-SUI, and 5012-SUR Safety and Regulatory Guide P/N 73921 June 2007 Products Covered in the GuideSafety and Regulatory Information 3 Products Covered in the Guide This document contains important safety and regulatory compliance information for the following products: Please see the following sections for more information: β€’Safety Information (USA, Canada, & European Union) –5012-SUI/5054-SUI –5012-SUR β€’Federal Communications Commission (FCC) Compliance –Modifications –Warnings β€’Regulatory Compliance Certifications Summary IMPORTANT! Visit http://support.proxim.com for the latest safety and regulatory compliance information for this product. Please read this document before installing and using your product, and save these instructions. ProductModel Numbers Tsunami MP.11 Models 5012-SUI, 5012-SUR, 5054-SUI 5012-SUI-WA-xx 5054-SUI-xx 5054-SUI-WA-xx 5012-SUR-xx Safety Information (USA, Canada, & European Union)Safety and Regulatory Information 4 Safety Information (USA, Canada, & European Union) 5012-SUI/5054-SUI This product has been evaluated to, and complies with the Safety requirements of IEC60950:1999, the Standards for the Safety of Information Technology Equipment. When using this device, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: β€’ Operate and install this product as described in this manual. This device must be installed and used in strict accordance with the manufacturer's instructions. β€’ Use only the AC/DC power supply adapter provided. For replacement, contact your local supplier or distributor. β€’ To avoid the risk of electric shock from lightning, do not use this product during an electrical storm. β€’ Installation of this product must conform to local regulations and codes. β€’ When using this product with an external antenna, see the installation documentation provided with the antenna system. β€’ No user serviceable parts; all repairs and service must be handled by a qualified service center. 5012-SUR This product has been evaluated to, and comply with, the U.S. and Canadian (Bi National) Standard for Safety of Information Technology Equipment, including Electrical Business Equipment and IEC60950:1999, the Standard for the Safety of Information Technology Equipment. The product is intended to be installed, used, and maintained by experienced telecommunications personnel only. When using this device, basic safety precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons, including the following: WARNING: These units are intended for installation in accordance with Articles 110 –18, 110-26, and 110-27, 725, 800, and 810 of the United States National Electric Code ANSINFPA 70, and per the applicable Articles in the Canadian National Electric Code. β€’ Operate and install these products as described in this manual. Equipment must be installed and used in strict accordance with the manufacturer's instructions as described in the user documentation provided. β€’ Installation of these products in the end use must conform to local regulations and codes. β€’ Products are to be used with and powered by an 802.3af compliant power injector. β€’ A 15-amp circuit breaker is required at the power source. WARNING: This equipment is intended to be grounded. A 10 AWG earthing conductor at a minimum is to be used for this purpose. β€’ Do not connect or disconnect the power cable to the equipment when the power injector is plugged into an AC power outlet. β€’ Servicing of these products should be performed only by trained personnel. Do not disassemble. By opening or removing any covers, you may expose yourself to hazardous energy parts. Incorrect reassembly of these products can cause a malfunction and/or electric shock when the units are subsequently used. No user serviceable parts; all repairs and service must be handled by a qualified service center. β€’ Do not insert any objects of any shape or size inside these products while powered on. Object may contact hazardous energy parts that could result in a risk of fire or personal injury. β€’ Do not remove or alter the Marking label provided on these products. β€’ To avoid the risk of electric shock from lightning, do not use these products during an electrical storm. Federal Communications Commission (FCC) ComplianceSafety and Regulatory Information 5 Federal Communications Commission (FCC) Compliance The 5012-SUI and 5054-SUI operate at 5.15 - 5.35 GHz, 5.47-5.725 GHz and 5.75 - 5.85 GHz in compliance with Part 15 of the FCC Rules. The 5012-SUR operates at 5.25 GHz - 5.35 GHz, 5.47-5.725 GHz and 5.75 - 5.85 GHz in compliance with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. To comply with the FCC radio frequency exposure requirements, the following antenna ins…

Text truncated - open the document above for the full version.

Cover Letter(s)

2115 O'Nel Drive, San Jose, CA 95131 P 408.731.2700 F 408.731.3675 www.proxim.com July 10, 2007 Compliance Certification Services Certification Division 561F Monterey Road Morgan Hill, CA 95037 To whom it may concern: We, the undersigned, hereby authorize the Testing Division of Compliance Engineering Services, Inc., d.b.a. Compliance Certification Services and hereafter referred to as CCS, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by CCS on our behalf shall have the same effect as acts of our own. In authorizing CCS Testing Division as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; 2115 O'Nel Drive, San Jose, CA 95131 P 408.731.2700 F 408.731.3675 www.proxim.com h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Caroline Yu Regulatory Compliance Manager Proxim Wireless Corporation REMARK: 1. This authorization letter will be sent along with your application when filing with the Certification Division. 2. Please follow the format and type it on company letterhead and send original to us.

Cover Letter(s)

2115 O’Nel Drive, San Jose, CA 95131 Tel (408) 731 2700, Fax (408)731 3675 August 1, 2007 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID: HZB-MP50XXSU To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR Β§Β§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Theory of Operation Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Best Regards Helen Zhao Regulatory Compliance Manager Proxim Wireless Corporation

Cover Letter(s)

http://mail.google.com/mail/?ui=1&ik=2a69a1bf8a&view=cv&search=inbox&th=115cdd0af84aea1c&ww=1131&cvap=1&qt=&zx=n5vcw9-7u84w3 RE: Proxim Wireless Corporation, FCC ID: HZB-MP50XXSU, Assessment NO.: AN07T7272, Notice#1 Inbox Reply from September Radecki <[email protected]> hide details 1:02 pm (5 minutes ago) to "Timothy M. Dwyer" <[email protected]> cc September Radecki <[email protected]>, Mike Kuo <[email protected]> date Oct 23, 2007 1:02 PM subject RE: Proxim Wireless Corporation, FCC ID: HZB-MP50XXSU, Assessment NO.: AN07T7272, Notice#1 Hi Tim, Below are the answers to your questions on this application. Q1: Please revise the label to include the statement of 15.19. <CCS ANSWER:> Revised ID Label and Location Exhibit is attached. Q2: Please revise the user manual to include appropriate user information, installation conditions, and RF exposure statements. <CCS ANSWER:> Please see attached revision which will be included with the manual. Q3: Test setup photos were provided only for the DFS tests. Please provide wireless conducted and radiated test setup photos for testing associated with both the IXM and AP700 reports. <CCS ANSWER:> There are two additional test setup exhibits attached. Q4: 5745-5825MHZ is listed for this 15E NII application. 5825 MHz is a 15E band-edge, so this frequency range specification is not possible under 15E. Additionally, the application is for 15E but the IXM test report submitted to cover the range is for 15C. 15E compliance is not shown in the 15C report for 5745-5825 MHz.. The AP700 report shows only 15E compliance for 5470-5725 MHz. The IXM report shows 15E compliance for 5150-5350 MHz. Please provide additional explanation or revised test reports. <CCS ANSWER:> Yes, this band should have been on the DTS application. Additional reports attached. Q5: The block diagram and schematics describe a device with 4 coaxial ports. From photos and other information, this device appears to have only a single coaxial port. Please provide some additional explanation. <CCS ANSWER:> HZB-AP700 uses one AR5112/2112 radio only, the other AR5112/2112 radio shown on the block diagram is depopulated. So there are only two antenna ports. The diference between HZB-AP700 and HZB-MP50XXSU is that HZBMP50XXSU uses only one antenna connector while HZB-AP700 uses two antenna ports. Q6: Please provide RF Exposure MPE evaluation data for this application. <CCS ANSWER:> Please see attached RF Exposure Report. Thanks and best regards, September September Radecki Compliance Certification Services 47173 Benicia Street Fremont, CA 94538 phone: 1-510-771-1090 fax: 1-510-661-0888 [email protected] <mailto:[email protected]> -----Original Message----- From: Timothy M. Dwyer Sent: Monday, October 22, 2007 4:04 PM To: September Radecki Cc: mike.kuo Subject: Proxim Wireless Corporation, FCC ID: HZB-MP50XXSU, Assessment NO.: AN07T7272, Notice#1 Dear September, The initial review of this application is complete. There is one issue that needs to be clarified before the review can be completed. The review for the composite DTS application AN07T7290 is nearly complete. Some issues for this application will be repeated in that one, but aside from those, the DTS application appears to be ok. I am sending this notice separately in the interest of expediting the process. Q1: Please revise the label to include the statement of 15.19. Q2: Please revise the user manual to include appropriate user information, installation conditions, and RF exposure statements. Q3: Test setup photos were provided only for the DFS tests. Please provide wireless conducted and radiated test setup photos for testing associated with both the IXM and AP700 reports. Q4: 5745-5825MHZ is listed for this 15E NII application. 5825 MHz is a 15E band-edge, so this frequency range specification is not possible under 15E. Additionally, the application is for 15E but the IXM test report submitted to cover the range is for 15C. 15E compliance is not shown in the 15C report for 5745-5825 MHz.. The AP700 report shows only 15E compliance for 5470-5725 MHz. The IXM report shows 15E compliance for 5150-5350 MHz. Please provide additional explanation or revised test reports. Q5: The block diagram and schematics describe a device with 4 coaxial ports. From photos and other information, this device appears to have only a single coaxial port. Please provide some additional explanation. If there is something I am missing or if you have questions, please let me know. Best regards, Tim Dwyer The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information within 30 days of the original e-mail date may result in application dismissal and forfeiture of the filing fee. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the e- mail address listed below the name of the sender. 7 attachments β€” Download all attachments MP.11_SUI-SUR_RegFlyer_v4.0.pdf 427K View as HTML Download Test setup photos.pdf 2120K View as HTML Download AP700 seup photos.pdf 464K View as HTML Download IXMAPAGAT01 FCC Report 1.pdf 2383K View as HTML Download IXMAPAGAT01 FCC Report 2.pdf 3921K View as HTML Download Revised ID Label and Location.pdf 65K View as HTML Download RF Exposure Report.pdf 139K View as HTML Download http://mail.google.com/mail/?ui=1&ik=2a69a1bf8a&view=cv&search=inbox&th=115cdd0af84aea1c&ww=1131&cvap=1&qt=&zx=n5vcw9-7u84w3 10/23/2007 1:09:19 PM

Cover Letter(s)

2115 O’Nel Drive, San Jose, CA 95131 Tel (408) 731 2700, Fax (408)731 3675 August 6, 2007 Federal Communications Commission Equipment Authorization branch 7435 Oakland Mills Road Columbia, MD 21046 Re: DFS Attestation Gentlemen: In reference to the application under FCC ID: HZB-MP50XXSU, the Applicant hereby attests that Ad Hoc Mode is disabled on non-US frequencies and on DFS frequencies. Sincerely, Best Regards Helen Zhao Regulatory Compliance Manager Proxim Wireless Corporation

Cover Letter(s)

2115 O’Nel Drive, San Jose, CA 95131 Tel (408) 731 2700, Fax (408)731 3675 August 16, 2007 Federal Communications Commission Equipment Authorization branch 7435 Oakland Mills Road Columbia, MD 21046 Re: FCC ID: HZB-MP50XXSU Model Name: 5012-SUI, 5054-SUI, 5012-SUR Dear Reviewer, This is a new application. But this device is electrically identical to the device under FCC ID: HZB-AP700 (model name: AP-700) and/or FCC ID: IXMAPAGAT01 (model name: AP-AG-AT- 01). The difference between HZB-MP50XXSU and HZB-AP700 is the software. FCC ID: HZB- AP700 is a master device, while FCC ID: HZB-MP50XXSU is a client device, with 2.4GHz band disabled. We will use the following reports for HZB-MP50XXSU certification: 1) Report under FCC ID: IXMAPAGAT01 Part 1 - please ignore 2,4GHz test data * 2) Report under FCC ID: IXMAPAGAT01 Part 2 - For 5.2, 5.3, 5/8G RF test data * 3) Report under FCC ID: IXMAPAGAT01 Part 3 - For 5.2, 5.3, 5/8G RF test data * 4) Report under FCC ID: HZB-AP700 - For 5.5G RF test data 5) Report under FCC ID: HZB-MP50XXSU - For 5.5G DFS test data * The authorization letter is attached. If you have any questions, please let me know. Sincerely, Helen Zhao Regulatory Compliance Manager Proxim Wireless Corporation

Cover Letter(s)

2115 O’Nel Drive, San Jose, CA 95131 Tel (408) 731 2700, Fax (408)731 3675 Oct. 19, 2007 Federal Communications Commission Equipment Authorization branch 7435 Oakland Mills Road Columbia, MD 21046 Re: FCC ID: HZB-MP50XXSU Dear Reviewer, This letter is to confirm that 40 MHz operation will be disabled in 5250-5350 MHz and 5470- 5725MHz bands. If you have any questions, please let me know. Sincerely, Helen Zhao Regulatory Compliance Manager Proxim Wireless Corporation

ID Label/Location Info

PROPOSED FCC ID LABEL AND LOCATION FCC /IC Label Location PROXIM CORPORATION This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: HZB-MP50XXSU IC: 1856A-MP50XXSU Model: TSUNAMI MP.11 SUBSCRIBER UNIT

Parts List/Tune Up Info

Type Manufacturer Model Number Frequency Range Mid-Band Gain Omni Proxim 5054-OA-8 5054-OA-10 1086-OA52-DC8 1086-OA54-DC8 848 072 633 1086-REA 1086-OA49-8 1086-OA49-10 5.47 – 5.85 5.47 – 5.85 4.9 – 5.35 5.4 – 5.9 5.2 – 5.9 2.4; 5.2 – 5.9 4.9 – 5.3 4.9 – 5.0 8 10 8 8 5 2.5; 3.5 8 10 Omni Mars Mars Mars Mars MTI MTI MTI MTI Stella Doradus Stella Doradus Stella Doradus Stella Doradus Stella Doradus Stella Doradus Stella Doradus Stella Doradus Stella Doradus Telex RadioWaves MA-WO49-B-X MA-WO49-7X MA-WO58-9X MA-WO55-10 MT-462006/N/A MT-482003/N MT-483003/N MT-482015/N/A 52 1360 52 2360 52 3360 56 1360 56 2360 56 3360 58 1360 58 2360 58 3360 5830 OMNH-5-8 4.9 – 5.0 4.9 – 5.0 5.47 – 5.875 4.9 – 5.9 4.9 - 5.1 5.15 – 5.875 5.725 – 5.875 5.725 – 5.925 5.1 – 5.3 5.1 – 5.3 5.1 – 5.3 5.4 – 5.7 5.4 – 5.7 5.4 – 5.7 5.7 – 5.9 5.7 – 5.9 5.7 – 5.9 5.725 – 5.85 5.725 – 5.85 2 7.5 9 10 8.5 9 12 10.5 (N-male) 7 10 13 7 10 13 7 10 13 7.5 8 (hor pol) Type Manufacturer Model Number Frequency Range Mid-Band Gain Sector Proxim 5054-WA-15-STN 5054-SA60-17 5054-SA120-14 5.2 – 5.9 4.9 – 5.9 4.9 – 5.9 15 17 14 Sector 60 degrees Mars Mars Mars MTI MTI MTI MTI MTI MTI RadioWaves RadioWaves MA-WC49-5X MA-WC50-5X MA-WC58-5EL MT-464002/NV MT-464002/NH MT-484026/NV MT-484026/NH MT-484033/NV MT-484033/NH SEC-55V-60-17 SEC-55H-60-17 4.9 – 5.0 5.15 – 5.875 5.725-5.875 4.9 - 5.35 4.9 – 5.1 5.15 – 5.875 5.15 – 5.875 5.15 – 5.875 5.15 – 5.875 5.25 – 5.85 5.25 – 5.85 17 17 16 (IR2007) 16 15.5 (h pol) 16 (Null-Fill) 15 (h pol, NF) 16.5 16.5 (h pol) 17 17 (hor pol) Sector 90 degrees Mars Mars Mars MTI MTI MTI MTI MTI RadioWaves RadioWaves Telex Telex MA-WD49-6X MA-WD50-6X MA-WD50-6H MT-464003/NH MT-484032/NV MT-484032/NH MT-484027/NV MT-484027/NH SEC-55H-90-16 SEC-55V-90-16 5801 5840 4.9 – 5.0 5.15 – 5.875 5.15 – 5.875 4.9 – 5.1 4.9 – 5.85 5.15 – 5.875 5.15 – 5.875 5.15 – 5.875 5.25 – 5.85 5.25 – 5.85 5.725 – 5.825 5.725 – 5.825 16 16 15.5 (hor pol) 15 (hor pol) 17 16.5 (h pol) 14 (Null-Fill) 14 (h pol, NF) 16 (hor pol) 16 12 15 Sector 120 degrees Mars Mars Mars Mars MTI MTI MTI MTI MTI RadioWaves RadioWaves MA-WE49-7X MA-WE50-7X MA-WE50-15 MA-WE58-7EL MT-444003/NV MT-464004/NH MT-484034/NV MT-484034/NH MT-484037/NV SEC-5V-120-14 SEC-5V-120-16 4.9 – 5.0 5.15 – 5.875 5.15 – 5.875 5.725 – 5.875 4.9 – 5.1 4.9 – 5.1 5.15 – 5.875 5.15 – 5.875 5.725 – 5.875 5.725 – 5.85 5.725 – 5.85 15 15 15 14 (IR2007) 15 15 (hor pol) 15 15 (hor pol) 15 (IR2007) 14 16 Type Manufacturer Model Number Frequency Range Mid-Band Gain Proxim 5054-PA-18 5054-PA-23 1086-PA50-7 1086-PA49-10 1086-PA49-21 5.2 – 5.9 5.7 – 5.9 5.2 – 5.9 4.9 – 5.8 4.9 – 5.0 18 23 7 10 21 Panel Gabriel Mars Mars Mars Mars MTI MTI Radiowaves DFPS.5-52 MA-WA57-3HG MA-WA57-3X MA-WA55-27 MA-WA56-DP25 MT-485001/N MT-486004/N FP.5-5-18 5.25 – 5.85 5.15 – 5.875 5.15 – 5.875 4.9 – 5.875 5.47 – 5.875 5.15 – 5.875 5.15 – 5.875 5.15 – 5.85 18 18 16 26 25.5 (dual pol) 18 26 18 1-Foot Flat Panel Andrew ARC Gabriel Mars Mars Mars MTI MTI MTI RadioWaves FPA5250D12-N ANT-A-1723-01 DFPD1-52 MA-WA49-1X MA-WA55-24 MA-WA58-1X MT-485028/N MT-485002/N MT-485034/N FP1-5-24 5.25 – 5.85 4.9 – 5.1; 5.1 – 5.9 5.25 – 5.85 4.9 – 5.4 4.9 – 5.875 5.15 – 5.875 5.15 – 5.875 5.15 – 5.875 5.25 – 5.875 5.15 – 5.85 23.6 19; 23 23.5 21 24 23 22 23 23 24 2-Foot Flat Panel Andrew Gabriel MTI MTI RSI RadioWaves FPA5250D24-N DFPD2-52 MT-486001/N MT-486009 A57A24-U FP2-5-28 5.25 – 5.85 5.25 – 5.85 5.15 – 5.875 5.15 – 6.0 5.725 – 5.85 5.15 – 5.85 28.2 28 28 28 26.5 28 Type Manufacturer Model Number Frequency Range Mid-Band Gain 2-Foot Parabolic Gabriel Gabriel Gabriel Radio Waves Radio Waves Radio Waves Andrew Andrew RSI SSP2-52B SSD2-52A HSSP2-52 SP2-5.2 HP2-5.2 SPD2-5.2 P2F-52 PX2F-52 P-57C24 5.25 – 5.85 5.25 – 5.85 5.25 – 5.85 5.25 – 5.85 5.25 – 5.85 5.25 – 5.85 5.25 – 5.85 5.25 – 5.85 5.25 – 5.85 28.5 28.4 28.1 29.0 28.6 28.1 (dual pol) 29.4 29.4 29 3-Foot Parabolic Andrew Andrew Radio Waves Radio Waves P3F-52 PX3F-52 SP3-5.2 SPD3-5.2 5.25 – 5.85 5.25 – 5.85 5.25 – 5.85 5.25 – 5.85 33.4 33.4 32.0 31.1 (dual pol)

RF Exposure Info

Report No.: 921107R01 1 RF EXPOSURE REPORT REPORT NO.: 921107R01 MODEL NO.: AP-AG-AT-01,AP-AG-AT-03, RT-AG-AT-01 ACCORDING: FCC Guidelines for Human Exposure IEEE C95.1 APPLICANT: UNIVERSAL SCIENTIFIC INDUSTRIAL CO., LTD. ADDRESS: 141, Lane 351, Taiping Road, Sec. 1, Tsao Tuen, Nan-Tou, Taiwan, R.O.C. ISSUED BY: Advance Data Technology Corporation LAB LOCATION: No. 81-1, Lu Liao Keng, 9 Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien, Taiwan, R.O.C. Lab Code: 200376-0 Report No.: 921107R01 2 RF Exposure Measurement 1. Introduction In this document, we try to prove the safety of radiation harmfulness to the human body for our product. The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 is followed. The Gain of the antenna used in this product is measured in a Fully Anechoic Chamber (FAC) calibrated for antenna measurement in ADT, and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis transmission formula is a far field assumption, the calculated result of that is an over-prediction for near field power density. We will take that as the worst case to specify the safety range. 2. RF Exposure Limit According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified in 1.1307(b) LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (minutes) (A)Limits For Occupational / Control Exposures 300-1500 ... ... F/300 6 1500-100,000 ... ... 5 6 (B)Limits For General Population / Uncontrolled Exposure 300-1500 ... ... F/1500 6 1500-100,000 ... ... 1.0 30 F = Frequency in MHz Report No.: 921107R01 3 3. Friis Formula Friis transmission formula : Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm Pd is the limit of MPE, 1 mW/cm 2 . If we know the maximum Gain of the antenna and the total power input to the antenna, through the calculation, we will know the MPE value at distance 20cm. Ref. : David K. Cheng, Field and Wave Electromagnetics, Second Edition, Page 640, Eq. (11-133). 4. EUT Operating condition The software provided by Manufacturer enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. 5. Classification This device is not fixed inside the host equipment, it is connected with host through wire. So it is easy to be re-located in the place where at least 20 cm far away from the body of the user. Warning statement to the user for keeping at least 20cm or more separation distance with the antenna should be included in users manual. So, this device is classified as Mobile Device. Report No.: 921107R01 4 6. Test Results 6.1 Antenna Gain Antenna 1: The maximum Gain of the antenna is 2.5dBi. Antenna 2: The maximum Gain of the antenna is 2.0dBi. Antenna 3: The maximum Gain of the antenna is 3.0dBi. Antenna 4: The maximum Gain of the antenna is 10.0dBi. Antenna 5: The maximum Gain of the antenna is 14.0dBi. Antenna 6: The maximum Gain of the antenna is 14.0dBi. Antenna 7: The maximum Gain of the antenna is 24.0dBi. FOR DSSS: Output Power Into Antenna & RF Exposure value at distance 20cm: Antenna 1 Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 1 2412 107.1519 0.03791 1.0 6 2437 136.1445 0.04816 1.0 11 2462 141.2537 0.04997 1.0 Antenna 2 Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 1 2412 141.9057 0.04474 1.0 6 2437 156.3148 0.49287 1.0 11 2462 138.6756 0.43725 1.0 Antenna 3 Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 1 2412 107.1519 0.04253 1.0 6 2437 136.1445 0.05404 1.0 11 2462 141.2537 0.05607 1.0 Report No.: 921107R01 5 Output Power Into Antenna & RF Exposure value at distance 100cm: Antenna 4 Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 1 2412 66.52732 0.00529 1.0 6 2437 123.02688 0.00979 1.0 11 2462 79.43282 0.00632 1.0 Antenna 5 Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 1 2412 7.26106 0.00145 1.0 6 2437 23.01442 0.00460 1.0 11 2462 23.17395 0.00463 1.0 Antenna 6 Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 1 2412 17.78279 0.00355 1.0 6 2437 60.53409 0.01210 1.0 11 2462 37.49730 0.00750 1.0 Antenna 7 Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 3 2422 7.26106 0.01451 1.0 6 2437 8.91251 0.01782 1.0 9 2452 7.14496 0.01428 1.0 Report No.: 921107R01 6 FOR OFDM: Output Power Into Antenna & RF Exposure value at distance 20cm: Antenna 1 Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 1 2412 128.5287 0.04547 1.0 6 2437 161.8080 0.05724 1.0 11 2462 137.0882 0.04850 1.0 Antenna 2 Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 1 2412 120.7814 0.03808 1.0 6 2437 212.8139 0.06710 1.0 11 2462 138.9953 0.04383 1.0 Antenna 3 Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 1 2412 128.5287 0.05102 1.0 6 2437 161.8080 0.64223 1.0 11 2462 137.0882 0.05442 1.0 Output Power Into Antenna & RF Exposure value at distance 100cm: Antenna 4 Chann…

Text truncated - open the document above for the full version.

Test Report

DFS PORTION OF FCC CFR47 PART 15 SUBPART E CERTIFICATION TEST REPORT FOR TSUNAMI MP.11 SUBSCRIBER UNIT MODEL NUMBER: 5012-SUI, 5054-SUI, 5012-SUR FCC ID: HZB-MP50XXSU REPORT NUMBER: 07U11101-1 ISSUE DATE: OCTOBER 12, 2007 Prepared for PROXIM WIRELESS 2115 O NEL DRIVE SAN JOSE, CA 95131, USA Prepared by COMPLIANCE CERTIFICATION SERVICES 47173 BENICIA STREET FREMONT, CA 94538, U.S.A. TEL: (510) 771-1000 FAX: (510) 661-0888 REPORT NO: 07U11101-1 DATE: OCTOBER 12, 2007 EUT: TSUNAMI MP.11 SUBSCRIBER UNIT FCC ID: HZB-MP50XXSU Page 2 of 2 COMPLIANCE CERTIFICATION SERVICES DOCUMENT NO: CCSUP4031A 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of CCS. Revision History Rev. Issue Date Revisions Revised By -- 10/12/07 Initial Issue M. Heckrotte REPORT NO: 07U11101-1 DATE: OCTOBER 12, 2007 EUT: TSUNAMI MP.11 SUBSCRIBER UNIT FCC ID: HZB-MP50XXSU Page 3 of 3 COMPLIANCE CERTIFICATION SERVICES DOCUMENT NO: CCSUP4031A 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of CCS. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS............................................................................................. 4 2. TEST METHODOLOGY .................................................................................................................. 5 3. FACILITIES AND ACCREDITATION .......................................................................................... 5 4. CALIBRATION AND UNCERTAINTY.......................................................................................... 5 4.1. MEASURING INSTRUMENT CALIBRATION ....................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ken Lim(Accounting Manager)
[email protected]408 383 7600Fax: 408 383 7680

Technical Contact

COMPLIANCE CERTIFICATION SERVICESMichael Heckrotte
[email protected]510-771-1000

47173 BENICIA STREET Β· FREMONT, California Β· United States

Non-Technical Contact

COMPLIANCE CERTIFICATION SERVICESMichael Heckrotte
[email protected]510-771-1000

Test Firm

Compliance Certification ServicesBarbara Judge
[email protected]510-771-1104Fax: 510-661-0888

Technical Specifications

#Rule PartsFrequency RangePower Output
315E5.50 GHz - 5.70 GHz247.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. Some antenna(s) specified in this filing must be installed to provide a separation distance of at least 20 cm from all persons. Some other antennas in this filing require professional installation. The antennas used for professional installation must be fixed-mounted on indoor/outdoor permanent structures with a separation distance of at least 100 cm from all persons. This device must not be co-located or operating in conjunction with any other antenna or transmitter other than those specified in this application. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device is approved for operation as a client device without radar detection to be used in conjunction with an approved master device.

Other Applications from Proxim Wireless Corporation

HZB-MEGA6

EdgeAX 6GHz Radio Module

Aug 12, 2026

Equipment Class

6FC - 15E 6 GHz Fixed Client
Startum X5 Gigabit 5 GHz Radio - FCC ID HZB-GIGA5 - Proxim Wireless Corporation
HZB-GIGA5

Startum X5 Gigabit 5 GHz Radio

Sep 21, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX
NGP LC 2.4 & 5 GHz Radios - FCC ID HZB-NGPAP - Proxim Wireless Corporation
HZB-NGPAP

NGP LC 2.4 & 5 GHz Radios

Apr 26, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
NGP LC 5 GHz Radio - FCC ID HZB-NGPLC - Proxim Wireless Corporation
HZB-NGPLC

NGP LC 5 GHz Radio

Mar 04, 2021

Equipment Class

DTS - Digital Transmission System
802.11 ac PCIe Module - FCC ID HZB-NGP1058W - Proxim Wireless Corporation
HZB-NGP1058W

802.11 ac PCIe Module

Nov 03, 2015

Equipment Class

DTS - Digital Transmission System