FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ZyXEL Communications Corporation/
  3. I88MAX100

I88MAX1002.5GHz WiMAX PCMCIA card

ZyXEL Communications Corporation
2.5GHz WiMAX PCMCIA card - FCC ID I88MAX100 - ZyXEL Communications Corporation
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Dec 18, 2007
Application Purpose
Original Equipment
Date of Application
Dec 13, 2007
Equipment Note
2.5GHz WiMAX PCMCIA card
Frequency Range
2505.00000000 - 2685.00000000
Company
ZyXEL Communications Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗
↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ZyXEL MAX-100 Series WiMAX PCMCIA Card User’s Guide Version 1.00 Edition 1 03/2007 ZyXEL MAX-100 Series User’s Guide Copyright3 Copyright Copyright © 2007 by ZyXEL Communications Corporation. The contents of this publication may not be reproduced in any part or as a whole, transcribed, stored in a retrieval system, translated into any language, or transmitted in any form or by any means, electronic, mechanical, magnetic, optical, chemical, photocopying, manual, or otherwise, without the prior written permission of ZyXEL Communications Corporation. Published by ZyXEL Communications Corporation. All rights reserved. Disclaimer ZyXEL does not assume any liability arising out of the application or use of any products, or software described herein. Neither does it convey any license under its patent rights nor the patent rights of others. ZyXEL further reserves the right to make changes in any products described herein without notice. This publication is subject to change without notice. Trademarks ZyNOS (ZyXEL Network Operating System) is a registered trademark of ZyXEL Communications, Inc. Other trademarks mentioned in this publication are used for identification purposes only and may be properties of their respective owners. ZyXEL MAX-100 Series User’s Guide 4Certifications Certifications Federal Communications Commission (FCC) Interference Statement The device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: • This device may not cause harmful interference. • This device must accept any interference received, including interference that may cause undesired operations. This device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio/television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1Reorient or relocate the receiving antenna. 2Increase the separation between the equipment and the receiver. 3Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement • This device has been tested to the FCC exposure requirements (Specific Absorption Rate). • Testing was performed on laptop computers with antennas at 0mm spacing. The maximum SAR value is: 0.85 0W/kg. The device must not be collocated with any other antennas or transmitters. • This equipment has been SAR-evaluated for use in laptops (notebooks) with side slot configuration. • The device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment, under 47 CFR 2.1093 paragraph (d)(2). End users must follow the specific operating instructions for satisfying RF exposure compliance. To maintain compliance with FCC RF exposure compliance requirements, please follow operation instruction as documented in this manual. • This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. ZyXEL MAX-100 Series User’s Guide Certifications5 注意 ! 依據 低功率電波輻射性電機管理辦法 第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用 者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現 有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。 前項合法通信,指依電信規定作業之無線電信。低功率射頻電機須忍 受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。 Notices Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Viewing Certifications 1Go to http://www.zyxel.com. 2Select your product from the drop-down list box on the ZyXEL home page to go to that product's page. 3Select the certification you wish to view from this page. ZyXEL MAX-100 Series User’s Guide 6Safety Warnings Safety Warnings For your safety, be sure to read and follow all warning notices and instructions. • Do NOT use this product near water, for example, in a wet basement or near a swimming pool. • Do NOT expose your device to dampness, dust or corrosive liquids. • Do NOT store things on the device. • Do NOT install, use, or service this device during a thunderstorm. There is a remote risk of electric shock from lightning. • Connect ONLY suitable accessories to the device. • Do NOT open the device or unit. Opening or removing covers can expose you to dangerous high voltage points or other risks. ONLY qualified service personnel should service or disassemble this device. Please contact your vendor for further information. • Do not use the device outside, and make sure all the connections are indoors. There is a remote risk of electric shock from lightning. • Antenna Warning! This device meets ETSI and FCC certification requirements when using the included antenna(s). Only use the included antenna(s). This product is recyclable. Dispose of it properly. ZyXEL MAX-100 Series User’s Guide ZyXEL Limited Warranty7 ZyXEL Limited Warranty ZyXEL warrants to the original end user (purchaser) that this product is free from any defects in materials or workmanship for a period of up to two years from the date of purchase. During the warranty period, and upon proof of purchase, should the product have indications of failure due to faulty workmanship and/or materials, ZyXEL will, at its discretion, repair or replace the defective products or components without charge for either parts…

Text truncated - open the document above for the full version.

Cover Letter(s)

American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 August 2, 2007 RE: ZyXEL Communications Corp FCC ID: I88MAX100 I have a few comments on this Application. Depending on your responses, kindly understand there may be additional comments. 1.) Please correct the application form 731 to show all information required for all Licensed radio transmitter devices. This will include frequency tolerance and emission designator. Please also indicate if the requested output power is radiated or conducted. 2.) Please provide better and clearer internal photographs. It should be possible to read the designators written on the cases of the integrated circuits. 3.) The SAR report does not included any of the required Z-axis plots. Please review. 4.) The calibration certificate includes probe correction values for 2600 MHz that were created by extrapolation. We are checking with FCC to confirm if this is a valid methodology. 5.) The label shows a DofC logo. Where was this devices tested for Part 15B compliance? 6.) The test report for Section 6, Table 2 does not appear to have been performed using the substitution method required by FCC and described in TIA/EIA 603. Please expand your measurement table of harmonic emissions to include antenna correction factors, cable loss, generator output level, etc. In addition, if a narrowband CW generator is used, please show how corrections between narrowband and broadband emissions are performed for both your 5 and 10 MHz bandwidths. 7.) Please provide voltage and current through the final power amplification elements as required by FCC rules. 8.) Please provide all required frequency stability data. 9.) Please provide written justification for all emission designators. 10.) FYI: Please note the tune up procedure specified by the Applicant specifies the power at 23dBm +/- 0.5dB. Please look carefully at all instances of conducted power before I begin my final review. You are reminded that conducted RF power is still the simplest and best way to compare RF power seen in the EMC report with RF power seen in the SAR report. William H. Graff President and Director of Engineering mailto: [email protected] The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information may result in application termination. Correspondence should be considered part of the permanent submission and may be viewed from the Internet after a Grant of Equipment Authorization is issued. Please do not respond to this correspondence using the email reply button. In order for your response to be processed expeditiously, you must submit your documents through the AmericanTCB.com website. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the sender.

Cover Letter(s)

Attention: Application Examiner Date: Nov. 13, 2007 Re: Response to FCC ID: I88MAX100 Comments Dear Sir, Thanks for your comments on Nov. 8 for FCC ID: I88MAX100, please see the answer as below. 1) With initial e-filing upload, please identify, justify, and describe: a) specific RF Profiles, certification profiles, test cases, test scripts that are appropriate for and were used to test this device, among those in the applicable conformance documents and standards b) relevant subclause cross-references to RF conformance test documents and standards, also info about availability of applicable sta ndards c) specific modulations, subchannelizations, permutations used for each test d) specific communications test eqpt and setup info and installed options/add-ons Answer: a)&b) The RF profile of EUT is followed WiMax forum Document “ WiMAX Forum™ Mobile System Profile Release 1.0 Approved Specification” Please see clause 4.1.1.2 table 6 of attachment 1. c) Please see Page 5 of the Test Report as attachment 2 and WiMAX forum document as attachment 1, clause 7, and Table 131. d) The Equipment photo and set-up information had been put on the FCC test report page 94 & 95 of attachement 3. 2) With initial e-filing upload, please describe how FDD and/or TDD modes are allowed under FCC allocated frequency range, i.e., device channel bandwidths allowed relative to available blocks and block sizes, and how device operates within system using specific paired (uplink/downlink) or unpaired bands Answer: The EUT is WiMAX device which used TDD mode not FDD mode. From the page 15, clause 4.1.1.2 table 6 of attachment 1, the EUT is compliant to not only frequency band (2496~2690MHz) of WiMAX Forum specification, but also lowest bandedge and highest bandedge of FCC Part 27 requirement. 3) With initial e-filing upload, please describe smart-antenna and/or beamforming modes if applicable Answer: The EUT does not use any beam-forming or smart antenna. 4) SAR report has: "The conducted output power was measured before and after the test using a wideband peak power meter." With initial e-filing upload, please provide info to show resolution bandwidth of peak-power meter is greater than signal bandwidth (10 MHz), and/or other info to support all related test results. Answer: please see the power meter spec. as attachment 4, you can find the bandwidth of instrument is over EUT’s bandwidth. Should you have any question, please don’t hesitate to let me know. Best regards. JT Chen Consultant Attachment 1 Page - 1 WiMAX FORUM PROPRIETARY – SUBJECT TO CHANGE WITHOUT NOTICE 1 2 WiMAX Forum ™ Mobile System Profile 3 Release 1.0 Approved Specification 4 (Revision 1.4.0: 2007-05-02) 5 WiMAX Forum™ Mobile System Profile Release 1.0 Approved Specification (Revision 1.4.0: 2007-04-12) Page - 15 WiMAX FORUM PROPRIETARY – SUBJECT TO CHANGE WITHOUT NOTICE 4. PHY Profile 1 4.1 Profiles of BS and MS 2 3 4.1.1 System Parameters 4 5 4.1.1.1 PHY Mode 6 Table 5. PHY Mode 7 Item Description Reference Status BS Required MS Required Comment 1 OFDMA 8.4 m Y Y OFDMA is the sole PHY mode within the scope of this document. 8 4.1.1.2 Band Class Index 9 10 System profile requirements of this document are applied to the following band class indices. Each index 11 shall specify one frequency range and one or more combinations of channel bandwidth, FFT size, channel 12 raster and duplexing mode. 13 14 BS support for a particular band class requires support of a frequency range that is a subset of the 15 complete frequency range defined by the band-class. The BS vendor shall provide a declaration of the 16 supported frequency range. The supported frequency range shall be a minimum of three (3) times the 17 largest supported channel bandwidth. MS must support the entire range of frequency defined by a band 18 class (or sub-bands) while the BS is required to support only sub-range of the band class declared by 19 vendor. 20 21 Table 6. Band Class Index 22 23 Band Class Index Frequency Range (GHz) Channel Frequency Step (kHz) Channel Bandwidth(s) (MHz) FFT Size Duplexing Mode Comments 5 512 TDD 10 1024 TDD Both bandwidths must be supported by the MS 1 2.3-2.4 250 8.75 1024 TDD 3.5 512 TDD 5 512 TDD 2 2.305-2.320, 2.345-2.360 250 10 1024 TDD 5 512 TDD 3 2.496-2.69 250 (200 KHz step size is also 10 1024 TDD Both bandwidths must be supported WiMAX Forum™ Mobile System Profile Release 1.0 Approved Specification (Revision 1.4.0: 2007-04-12) Page - 16 WiMAX FORUM PROPRIETARY – SUBJECT TO CHANGE WITHOUT NOTICE recommended for band class 3 in Europe) to by the MS 5 512 TDD 7 1024 TDD 4 3.3-3.4 250 10 1024 TDD 5 512 TDD 7 1024 TDD 3.4-3.8 250 10 1024 TDD 5 512 TDD 7 1024 TDD 3.4-3.6 250 10 1024 TDD 5 512 TDD 7 1024 TDD 5 3.6-3.8 250 10 1024 TDD 1 2 4.1.1.3 Sampling Factor 3 Table 7. Sampling Factor 4 Item Description Reference Status BS Required MS Required Comment 1 If channel bandwidth is a multiple of 1.75MHz then n=8/7 else if channel bandwidth is a multiple of any of 1.25, 1.5, 2 or 2.75 MHz then n=28/25 else if not otherwise specified then n=8/7. 8.4.2.3 m Y Y 5 4.1.1.4 Cyclic Prefix 6 Table 8. Cyclic Prefix 7 Item Description Reference Status BS Required MS Required Comment 1 1/4 8.4.2.3 oi N N 2 1/8 8.4.2.3 oi Y Y 3 1/16 8.4.2.3 oi N N 4 1/32 8.4.2.3 oi N N 8 4.1.1.5 Frame Length 9 Table 9. Frame Length 10 Item Description Reference Status BS Required MS Required Comment 1 20 ms 8.4.5.2 oi N N 2 12.5 8.4.5.2 oi N N 3 10 8.4.5.2 oi N N Attachment 2 FCC ID. : I88MAX100 Report No.: EME-070467 Page 5 of 95 EUT RF Profile of WiMax forum: 1. RF Profile: Frequency Range (GHz) Channel Frequency Step (kHz) Channel Bandwidth(s)(MHz) FFT size Duplexing Mode 5 512 TDD 2.496 – 2.69 250 10 1024 TDD 2. PHY Parameter: Parameter Uplink Uplink System Bandwidth 5MHz 10MHz FFT Size 512 1024 Null Sub-Carriers 104 184 Pilot Sub-Carriers 136 280 Data Sub-Carriers 272 560 Sub-Channels 17 35 Symbol Period, Ts 102.9 microseconds Frame Duration 5 millisecond OFDM Symbols/Frame 48 D…

Text truncated - open the document above for the full version.

Cover Letter(s)

George Chen 寄件者: Lyn Yang Intertek [[email protected]] 寄件日期: 2007年12月14日星期五 上午 9:28 收件者: Major Chen 副本: William Graff; GeorgeChen; [email protected]; Angela Lin Intertek; Sunny Liu Intertek 主旨: RE: Response to Inquiry to FCC (Tracking Number 950231) (TCB) 2007/12/15 Dear Major, It's really a good news!! Ha..ha.... Many thanks for you all kind help for this project. Best regards. Lynn Yang Sr. Specialist Tel: 886-3-519-1411 ext:303 Intertek 11, Ln. 275, Ko Nan 1st st. Shiang-Shan District, Hsinchu 300 Taiwan, R.O.C. Fax: 886-3-519-1410 e-mail: [email protected] www.taiwan.intertek-etlsemko.com From: Major Chen [mailto:[email protected]] Sent: Friday, December 14, 2007 8:49 AM To: Lyn Yang Intertek Cc: 'William Graff'; 'GeorgeChen'; '[email protected]'; 'Major Chen' Subject: FW: Response to Inquiry to FCC (Tracking Number 950231) (TCB) Importance: High Dear Lynn, Good morning! And good news for you. We will proceed to generate the preliminary grant and do the e-filing today. But we still need final approval from FCC. Thanks, Major From: [email protected] [mailto:[email protected]] Sent: Friday, December 14, 2007 5:21 AM To: [email protected] Subject: Response to Inquiry to FCC (Tracking Number 950231) (TCB) Importance: High Inquiry: --- Reply from Customer on 12/12/2007 --- 11/14/07 "Reply to an Inquiry Response" did not re-set FCC-internal status to "Pending Inquiry" "Reply to an Inquiry Response" by FCC herein intended to re-set TCB please notify TCBC to contact FCC about apparent system issues with "Reply to an Inquiry Response" function Response: as stated in 11/5/07: -------------------- Filing approved for initial e-filing upload contingent upon below items - when upload complete but before final grant, please respond within this inquiry number to request approval to grant. --------------------------------------------- after upload but before grant, please reply to this inquiry herein, including TC and / or FCC ID, to request final approval to grant Do not reply to this message. Please select the Reply to an Inquiry Response link from the OET Inquiry System to add any additional information pertaining to this inquiry. CONFIDENTIALITY NOTICE This email may contain confidential or privileged information, if you are not the intended recipient, or the person responsible for delivering the message to the intended recipient then please notify us by return email immediately. Should you have received this email in error then you should not copy this for any purpose nor disclose its contents to any other person. www.intertek.com <http://www.intertek.com> 在這裡按一下滑鼠右鍵 下載圖片。為了協助保 護您的隱私,Outlook 避 免自動從網際網路下載 Office of Engineering and Technology 2007/12/15

External Photos

Photo 1: External photo of EUT Photo 2: External photo of EUT NWD670

ID Label/Location Info

FCC ID Label Location

Internal Photos

Photo 1: Internal photo of EUT Photo 2: Internal photo of EUT MAX-100 MAX-100 Photo 3: Internal photo of EUT Photo 4: Internal photo of EUT MAX-100

Operational Description

Currently Displaying Inquiry Tracking Number: 950231 l Inquiry Details l Correspondence l Status History Contact Information: Customer First Name: William Customer Last Name: Graff Telephone Number: 703-847-4700 Extension: E-mail Address: [email protected] Address: Line 1:6731 Line 2:Suite P.O. Box: City:McLean State:Virginia Zip Code:22101 Country: United States Inquiry Details: First category: TCB Procedures Second category: Permit but Ask Third category: Non-handset SAR Subject: Part 27 Text of Inquiry: Inquiry: Gentlemen, Attached please find External Photos, a Test Report and SAR Report for a Part 27 2.5 GHz WiMax PCMCIA card. We have reviewed the filing and seek permission to Grant. Users manual will be coming shortly Best Regards, Bill Response: following from KDB pub 450824 appears to be applicable When other radiating sources instead of reference dipoles are used for system verification, vigorous validations are required to determine SAR target values. SAR measurements with system verifications using Page 1 of 3OET Inquiry System Inquiry Tracking Number 950231 12/13/2007http://fccweb01w.fcc.gov/oetcf/kdb/processing/reports/InquiryDetailReport.cfm?tracking... non-standard RF sources should be submitted to the FCC for equipment approval. Inquiry: ---Reply from Customer on 10/12/2007--- On behalf of Bill Graff, I have been requested to upload a new revised Test report and the Users Manual. Please see attached. Does this affect the response as provided. Tim Johnson for Bill Graff. Response: preceding FCC response pertains to that SAR report does not use dipole standard source for system verification; new attachments appear to be unrelated to SAR Inquiry: ---Reply from Customer on 10/28/2007--- The following response is provided by the submitting laboratory for this KDB inquiry: Response: per 2.962(f)(5)(i) and KDB 450824 applications containing SAR reports which do not use reference dipoles of type described in IEEE Std 1528 do not qualify for TCB processing, instead should be filed at FCC Inquiry: ---Reply from Customer on 11/05/2007--- Please find the following revised SAR test report which use standard reference dipole for system validation and also re-conducts the SAR measurements for this device. Response: -------------------- Filing approved for initial e-filing upload contingent upon below items - when upload complete but before final grant, please respond within this inquiry number to request approval to grant. --------------------------------------------- 1) With initial e-filing upload, please identify, justify, and describe: a) specific RF Profiles, certification profiles, test cases, test scripts that are appropriate for and were used to test this device, among those in the applicable conformance documents and standards b) relevant subclause cross-references to RF conformance test documents and standards, also info about availability of applicable standards c) specific modulations, subchannelizations, permutations used for each test d) specific communications test eqpt and setup info and installed options/add-ons 2) With initial e-filing upload, please describe how FDD and/or TDD modes are allowed under FCC allocated frequency range, i.e., device channel bandwidths allowed relative to available blocks and block sizes, and how device operates within system using specific paired (uplink/downlink) or unpaired bands 3) With initial e-filing upload, please describe smart-antenna and/or beamforming modes if applicable 4) SAR report has: Page 2 of 3OET Inquiry System Inquiry Tracking Number 950231 12/13/2007http://fccweb01w.fcc.gov/oetcf/kdb/processing/reports/InquiryDetailReport.cfm?tracking... Attachment List: External photos EMC Test Report , for internal use only SAR test report , for internal use only Operational description , for internal use only New Revised Test Report Users Manual , for internal use only revised SAR test report SAR Validation Antenna Description , for internal use only Reply to OET inquiry "The conducted output power was measured before and after the test using a wideband peak power meter." With initial e-filing upload, please provide info to show resolution bandwidth of peak-power meter is greater than signal bandwidth (10 MHz), and/or other info to support all related test results. --------------------------------------------- Inquiry: ---Reply from Customer on 11/14/2007--- Please find the following replies to OET inquiry item-by-item. Response: Inquiry: ---Reply from Customer on 12/12/2007--- 11/14/07 "Reply to an Inquiry Response" did not re-set FCC-internal status to "Pending Inquiry" "Reply to an Inquiry Response" by FCC herein intended to re-set TCB please notify TCBC to contact FCC about apparent system issues with "Reply to an Inquiry Response" function Response: as stated in 11/5/07: -------------------- Filing approved for initial e-filing upload contingent upon below items - when upload complete but before final grant, please respond within this inquiry number to request approval to grant. --------------------------------------------- after upload but before grant, please reply to this inquiry herein, including TC and / or FCC ID, to request final approval to grant Page 3 of 3OET Inquiry System Inquiry Tracking Number 950231 12/13/2007http://fccweb01w.fcc.gov/oetcf/kdb/processing/reports/InquiryDetailReport.cfm?tracking...

Operational Description

Major Chen 寄件者: [email protected] 寄件日期: 2007年12月20日星期四 上午 2:28 收件者: [email protected] 主旨: Response to Inquiry to FCC (Tracking Number 950231) (TCB) 重要性: 高 第 1 頁,共 2 頁 2007/12/20 Inquiry: --- Reply from Customer on 12/19/2007 --- All the required documents for FCC ID: I88MAX100 were uploaded completely under TC807673 and waiting for your final approval to grant. Response: filing approved to grant without additional correspondence in this KDB, and contingent upon completion of following items: - as stated several places in FCC-TCB guidance notes, intergral-antenna CardBus-type cards please use Eqpt Class TNB not TNT (PCB if device has part 24) - TCB please apply KDB pub 388264 requirement to include internal-only comment in Form-731 stating present KDB inquiry no. - if not in filing already, please submit test setup photos and/or spec-sheet for SAR system verification dipole Do not re ply to this message. Please select the Reply to an Inquiry Response link from the OET Link to Federal Communications Commission Home FCC Home | Search | Updates | E-Filing | Initiatives | For Consumers | Find Office of Engineering and Technology Office of Engineering and Technology Inquiry System to add any additional information pertaining to this inquiry. 第 2 頁,共 2 頁 2007/12/20

RF Exposure Info

FCC ID.: I88MAX100 Report No.: EME-070469 Page 1 of 146 Specific Absorption Rate (SAR) Test Report for ZyXEL Communications Corporation on the 2.5GHz WiMAX PCMCIA card Model Number: MAX-100 Test Report: EME-070469 Issue date: Oct. 31, 2007 Total No of Pages Contained in this Report: 146 Tested by: Kevin Chen Reviewed by: JT Chen Review Date: Nov. 01, 2007 All services undertaken are subject to the following general policy: Reports are submitted for exclusive use of the client to whom they are addressed. Their significance is subject to the adequacy and representative character of the samples and to the comprehensiveness of the tests, examinations or surveys made. This report shall not be reproduced except in full, without written consent of Intertek Testing Services, Taiwan Ltd. 0597 FCC ID.: I88MAX100 Report No.: EME-070469 Page 2 of 146 Table of Contents 1.0 General information .................................................................................................................. 3 1.1 Client Information ............................................................................................................. 3 1.2 Equipment under test (EUT).............................................................................................. 4 1.3 Test plan reference ............................................................................................................. 4 1.4 Modifications required for compliance ............................................................................. 4 1.5 Test configuration .............................................................................................................. 5 1.5.1 Support equipment & EUT antenna position.................................................................. 5 1.5.2 Test Condition................................................................................................................. 6 2.0 SAR Evaluation......................................................................................................................... 7 2.1 SAR Limits ........................................................................................................................ 7 2.2 Configuration Photographs ................................................................................................ 8 2.3 SAR measurement system ............................................................................................... 18 2.4 SAR measurement system validation .............................................................................. 20 2.4.1 System Validation result ............................................................................................... 21 2.4.2 System Performance Check result ................................................................................ 23 2.5 Test Result........................................................................................................................ 25 3.0 Test Equipment ....................................................................................................................... 26 3.1 Equipment List ................................................................................................................ 26 3.2 Tissue Simulating Liquid................................................................................................. 26 3.2.1 Body Tissue Simulating Liquid for evaluation test ...................................................... 26 3.2.2 Body Liquid result ........................................................................................................ 26 3.3 E-Field Probe and 2600 Balanced Validation Dipole Antenna Calibration..................... 26 4.0 Measurement Uncertainty ....................................................................................................... 26 5.0 WARNING LABEL INFORMATION - USA ....................................................................... 26 6.0 REFERENCES........................................................................................................................ 26 7.0 Document Revision Record .................................................................................................... 26 APPENDIX A - SAR Evaluation Data ......................................................................................... 26 APPENDIX B - Photographs ........................................................................................................26 APPENDIX C - E-Field Probe and 2600MHz Dipole Antenna Calibration Data FCC ID.: I88MAX100 Report No.: EME-070469 Page 3 of 146 1.0 General information The EUT is WiMax product with PCMCIA interface card; it was tested at the Intertek Testing Services facility in Hsinchu, Taiwan. The maximum output power declared by the ZyXEL. EUT model MAX-100 was evaluated in accordance with the requirements for compliance testing defined in FCC OET Bulletin 65, Supplement C (Edition 01-01) and meet the SAR requirement, the phantom employed was the box phantom of 2mm thick in one wall. The total uncertainty for the evaluation of the spatial peak SAR values averaged over a cube of 1g tissue mass had been assessed for this system to be ±20.6%, the dosimetry assessment system INDEXSAR SARA2 was used. In summary, the maximum spatial peak SAR value for the sample device averaged over 1g was found to be: Phantom Position (worst case) SAR 1g , W/kg 2mm thick box phantom wall EUT perpendicular to …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Emma Bao(Section Manager)
[email protected]886 3 578-3942Fax: 886 3 578-2439

Technical Contact

Intertek Testing Services Taiwan Ltd.Kevin Chen
[email protected]886-3-519-1411

No.11,Ko-Tze-Nan Chia-Tung Li, Shiang-Shan · Hsinchu · Taiwan

Test Firm

Intertek Testing Services Taiwan Ltd.Alpha Liu
[email protected]886-3-519-1411Fax: 886-3-519-1410

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
2272.50 GHz - 2.69 GHz259.00 mW9M66G9W9.7 ppm
Confidentiality
Long Term
Grant Notes
Power Output is EIRP. SAR compliance has been established in a laptop computer configuration with side PCMCIA slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter. The highest reported SAR values is: 0.85 W/kg.

Other Applications from ZyXEL Communications Corporation

I88EE6601-00

Tri-Band Wireless BE19000 10G Ethernet VoIP Gateway with SFP+ / Tri-Band Wireless BE19000 10G Ethernet VoIP Gateway / Tri-Band Wireless BE19000 10G Ethernet Gateway with SFP+ / Tri-Band Wireless BE19000 10G Ethernet Gateway

Jul 18, 2024

Equipment Class

6ID - 15E 6 GHz Low Power Indoor Access Point
802.11be (WiFi 7) Triple-Radio Unified Pro Access Point - FCC ID I8803935 - ZyXEL Communications Corporation
I8803935

802.11be (WiFi 7) Triple-Radio Unified Pro Access Point

Oct 17, 2023

Equipment Class

DTS - Digital Transmission System
802.11ax (WiFi 6) Dual-Radio Wall-Plate Unified Access Point - FCC ID I8803973 - ZyXEL Communications Corporation
I8803973

802.11ax (WiFi 6) Dual-Radio Wall-Plate Unified Access Point

Aug 01, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX
AX7800 WiFi 6E Tri-Band Gigabit Wireless Extender - FCC ID I88WX5610-B0 - ZyXEL Communications Corporation
I88WX5610-B0

AX7800 WiFi 6E Tri-Band Gigabit Wireless Extender

Apr 25, 2023

Equipment Class

DTS - Digital Transmission System
AX11000 WiFi 6E 10G Ethernet Gateway - FCC ID I88EX7710-B0 - ZyXEL Communications Corporation
I88EX7710-B0

AX11000 WiFi 6E 10G Ethernet Gateway

Apr 16, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX