FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Motorola Mobility LLC/
  3. IHDT56AS7

IHDT56AS7Mobile Cellular Phone

Motorola Mobility LLC

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Aug 06, 2024
Application Purpose
Original Equipment
Date of Application
Jul 09, 2024
Equipment Note
Mobile Cellular Phone
Frequency Range
5745.00000000 - 5825.00000000
Company
Motorola Mobility LLC
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Motorola Mobility LLC 222 W. Merchandize Mart Plaza, Chicago Il US www.motorola.com Date: June 28, 2024 Federal Communications Commission Office of Engineering and Technology Laboratory Division 7435 Oakland Mills Rd Columbia MD 21046-1609 Subject: Certifications concerning “covered” equipment pursuant to Part 2.911(d)(5)(i) and (ii) FCC ID: IHDT56AS6 FCC ID: IHDT56AS7 To Whom It May Concern, As required by section 2.911(d)(5)(i) of Commission’s rules (47 CFR), Motorola Mobility LLC certifies that, as of the date of the filing of the application, the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. As required by section 2.911(d)(5)(ii) of Commission’s rules (47 CFR), Motorola Mobility LLC certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Jeff Narducci Director, Global Regulatory Compliance [email protected]

Attestation Statements

Motorola Mobility LLC 222 W. Merchandize Mart Plaza, Chicago Il US www.motorola.com Date: June 28, 2024 Federal Communications Commission Office of Engineering and Technology Laboratory Division 7435 Oakland Mills Rd Columbia MD 21046-1609 Subject: Certification Designing a U.S. Agent for Service of Process Concerning “Covered” Equipment Pursuant to Section 1.50002 FCC ID: IHDT56AS6 FCC ID: IHDT56AS7 To Whom It May Concern, As required by section 2.911(d)(7) of Commission’s rules (47 CFR), Motorola Mobility LLC acknowledge, consents and certifies that, as of the date of the filing of the application until this certification is revoked in writing by the applicant: • The applicant designates itself as the U.S. agent to accept service of process. • The physical U.S. address and email of the applicant as designated agent are as follows: Attention: Jeff Narducci Company: Motorola Mobility LLC Address: 222 W. Merchandize Mart Plaza, Chicago Il US FRN: 0004321311 Email: Jeff Narducci <[email protected]> • Applicant will remain as the designated agent for service for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. • The agent accepts the designation by Motorola Mobility LLC as the U.S. agent to accept service of process includes, but is not limited to, delivery of any correspondence, notices, orders, decisions, and requirements of administrative, legal, or judicial process related to Commission proceedings. Sincerely, Jeff Narducci Director, Global Regulatory Compliance [email protected]

Cover Letter(s)

Motorola Mobility LLC 222 W. Merchandize Mart Plaza, Chicago Il US www.motorola.com Date: June 28, 2024 Federal Communications Commission Office of Engineering and Technology Laboratory Division 7435 Oakland Mills Rd Columbia MD 21046-1609 Subject: Request for Confidentiality FCC ID: IHDT56AS6 FCC ID: IHDT56AS7 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting confidentiality for exhibits filed with the commission supporting the application of equipment authorization for those items referenced above. Motorola Mobility respectfully requests the Commission to withhold indefinitely from public disclosure the following attachments under Long-Term Confidentiality. ⚫ Schematic Diagrams ⚫ Block Diagrams ⚫ Part List ⚫ Operational Description ⚫ Tune-up Procedure The above listed documents contain detailed system and equipment descriptions that are proprietary and confidential information under Motorola trade secret protection. Public disclosure of above documents would be harmful to our company and would provide competitors an unfair advantage. This information is not made publicly available even after commercial release of the device. In additional to the above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We request the commission to grant short-term confidentiality request on the following attachments for 180 days after the grant as outlined in Public Notice DA 04-1705. ⚫ External Photos ⚫ Internal Photos ⚫ Test Setup Photos ⚫ User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondence during certification review process cannot be granted as confidential documents and that information will be available for public review once the grant of equipment authorization is issued. Sincerely, Jeff Narducci Director, Global Regulatory Compliance [email protected]

Cover Letter(s)

Motorola Mobility LLC 222 W. Merchandize Mart Plaza, Chicago Il US www.motorola.com Date: June 28, 2024 To whom it may concern, Please be notified that I, Jeff Narducci, have designated Jones Tsai of Sporton International Inc. and Linbiaochun of Motorola Mobility LLC as the persons being responsible for this project and to sign the form 731 and other documentation. Any and all acts carried out in their professional capacity by Jones Tsai of Sporton International Inc. and Linbiaochun of Motorola Mobility LLC in connection with all processes required for FCC approval and any communication needed with the national authority, shall have the same legal authority as acts on our own behalf. We further certify that neither the applicant nor any party to this application, as defined in 47 CFR Ch. 1.2002 (b), is subject to a denial to Federal benefits, that include FCC benefits, pursuant to section 5301 of the Anti-Drug Abuse Act of 1998, 21 U.S.C. 862. This authorization is limited to the following product, and shall remain in place until completion of the certification, or until revoked, whichever is earlier: FCC ID: IHDT56AS6 FCC ID: IHDT56AS7 If you have any acknowledgement and response, please send it to Sporton International Inc. directly. Should you have any questions or comments regarding this matter, please don’t hesitate to contact me. Sincerely yours, Jeff Narducci Director, Global Regulatory Compliance [email protected]

Cover Letter(s)

Declaration Model Information: Manufacturer’s Name: Motorola Mobility LLC Manufacturer’s Business Address: 222 W, Merchandise Mart Plaza, Chicago IL 60654 USA Model Name: XT2409-2,XT2409-1,XT2409-6 HW version: DVT2 SW version: UUI34.42 Description: We Motorola Mobility LLC declare Software change history are list below Software Change Note SW 1:UUI34.42 SW 2:UUI34.32 SW 3:UUI34.38 SW 4:UUI34.45 The difference between SW 1 SW 2,SW 3 and SW4 is just for different SW version that not affect the RF test _________ Advisory Engineer,GT Cert Tel Email +86-18150396535 [email protected] Date 2024.7.05 Signature

ID Label/Location Info

FCC E-Label Information A. Images of the e-label screen are provided below: B. Access to the required information on the e-label Users are able to access the information in no more than three steps in a device’s menu. The actual steps are: Settings > then type Regulatory No any special accessories, access codes, or SIM card are required to go through the above steps. C. Devices have physical labels at point of marketing/sale visible to the purchaser (or in the alternative, on the packaging), and at time of importation? At the time of importation, marketing, and sale, the device will have the required physical label on the packaging, which will include the device’s FCC ID. D. Electronic labeling information is programmed into the device by the manufacturer at the time of manufacture. Yes. E. Electronic labeling information not modifiable by any third party. The e-label of the device is programmed by the grantee and secured in such a manner that it cannot be modified by third parties. F. All the applicable regulatory information required on the packaging or user instructions is provided according to the rules. Applicable regulatory information not found in the e-label is contained in the user manual.

RF Exposure Info

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/6/3 System Check_Head_750MHz DUT: D750V3 -SN:1087 Communication System: UID 0, CW (0); Frequency: 750 MHz;Duty Cycle: 1:1 Medium: HSL_750 Medium parameters used: f = 750 MHz; σ = 0.9 S/m; ε r = 41.192; ρ = 1000 kg/m 3 Ambient Temperature:23.3 °C; Liquid Temperature:22.6 °C DASY5 Configuration: -Probe: EX3DV4 -SN3857; ConvF(9.21, 8.75, 9.15); Calibrated: 2024/1/22 -Sensor-Surface: 1.4mm (Mechanical Surface Detection) -Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 -Phantom: SAM Twin Phantom; Type: SAM Twin; Serial: TP-1697 -Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Pin=50mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.567 W/kg Pin=50mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 26.61 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 0.617 W/kg SAR(1 g) = 0.436 W/kg; SAR(10 g) = 0.293 W/kg Smallest distance from peaks to all points 3 dB below = 16.7 mm Ratio of SAR at M2 to SAR at M1 = 70.3% Maximum value of SAR (measured) = 0.563 W/kg 0 dB = 0.563 W/kg = -2.49 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/6/5 System Check_Head_835MHz DUT: D835V2 -SN:4d091 Communication System: UID 0, CW (0); Frequency: 835 MHz;Duty Cycle: 1:1 Medium: HSL_835 Medium parameters used: f = 835 MHz; σ = 0.902 S/m; ε r = 41.24; ρ = 1000 kg/m 3 Ambient Temperature:23.3 °C; Liquid Temperature:22.9 °C DASY5 Configuration: -Probe: EX3DV4 -SN3857; ConvF(9.29, 8.23, 9.75); Calibrated: 2024/1/22 -Sensor-Surface: 1.4mm (Mechanical Surface Detection) -Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 -Phantom: SAM Twin Phantom; Type: SAM Twin; Serial: TP-1697 -Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Pin=50mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.596 W/kg Pin=50mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 27.46 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 0.658 W/kg SAR(1 g) = 0.461 W/kg; SAR(10 g) = 0.307 W/kg Smallest distance from peaks to all points 3 dB below = 16.3 mm Ratio of SAR at M2 to SAR at M1 = 69.8% Maximum value of SAR (measured) = 0.597 W/kg 0 dB = 0.597 W/kg = -2.24 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/6/7 System Check_Head_1750MHz DUT: D1750V2 -SN:1090 Communication System: UID 0, CW (0); Frequency: 1750 MHz;Duty Cycle: 1:1 Medium: HSL_1750 Medium parameters used: f = 1750 MHz; σ = 1.409 S/m; ε r = 40.669; ρ = 1000 kg/m 3 Ambient Temperature:23.2 °C; Liquid Temperature:22.8 °C DASY5 Configuration: -Probe: EX3DV4 -SN3857; ConvF(7.78, 7.1, 7.9); Calibrated: 2024/1/22 -Sensor-Surface: 1.4mm (Mechanical Surface Detection) -Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 -Phantom: SAM Twin Phantom; Type: SAM Twin; Serial: TP-1697 -Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Pin=50mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 3.02 W/kg Pin=50mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 47.95 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 3.52 W/kg SAR(1 g) = 1.91 W/kg; SAR(10 g) = 0.998 W/kg Smallest distance from peaks to all points 3 dB below = 9.6 mm Ratio of SAR at M2 to SAR at M1 = 57.1% Maximum value of SAR (measured) = 3.01 W/kg 0 dB = 3.01 W/kg = 4.79 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/6/9 System Check_Head_1900MHz DUT: D1900V2 -SN:5d118 Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1 Medium: HSL_1900 Medium parameters used: f = 1900 MHz; σ = 1.397 S/m; ε r = 39.035; ρ = 1000 3 kg/m Ambient Temperature:23.1 °C; Liquid Temperature:22.6 °C DASY5 Configuration: - Probe: EX3DV4 - SN3857; ConvF(7.93, 7.26, 8.03); Calibrated: 2024/1/22 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: SAM Twin Phantom; Type: SAM Twin; Serial: TP-1697 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Pin=50mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 2.54 W/kg Pin=50mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 43.06 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 3.51 W/kg SAR(1 g) = 2.02 W/kg; SAR(10 g) = 1.07 W/kg Smallest distance from peaks to all points 3 dB below = 11.2 mm Ratio of SAR at M2 to SAR at M1 = 57.7% Maximum value of SAR (measured) = 2.54 W/kg 0 dB = 2.54 W/kg = 4.05 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/6/11 System Check_Head_2450MHz DUT: D2450V2 - SN:1095 Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1 Medium: HSL_2450 Medium parameters used: f = 2450 MHz; σ = 1.806 S/m; ε r = 38.605; ρ = 1000 kg/m 3 Ambient Temperature:23.2 °C; Liquid Temperature:22.6 °C DASY5 Configuration: -Probe: EX3DV4 -SN3857; ConvF(7.44, 6.79, 7.48); Calibrated: 2024/1/22 -Sensor-Surface: 1.4mm (Mechanical Surface Detection) -Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 -Phantom: SAM Twin Phantom; Type: SAM Twin; Serial: TP-1697 -Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Pin=50mW/Area Scan (71x71x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 3.95 W/kg Pin=50mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 47.98 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 4.83 W/kg SAR(1 g) = 2.45 W/kg; SAR(10 g) = 1.16 W/kg Smallest distance from peaks to all points 3 dB below = 9 mm Ratio of SAR at M2 to SAR at M1 = 51.4% Maximum value of SAR (measured) = 4.00 W/kg 0 dB = 4.00 W/kg = 6.02 dBW/kg Test Laboratory: S…

Text truncated - open the document above for the full version.

RF Exposure Info

Date: 2024-06-05 01_LTE Band 12_10M_QPSK_1RB_0Offset_Right Cheek_0mm_Ch23095 Communication System: Band 12; Frequency: 707.500 Medium: HSL. Medium parameters used: f= 707.500 MHz; σ= 0.885 S/m; ε r = 41.3 Ambient Temperature: 23.3°C; Liquid Temperature: 22.8°C DASY6 Configuration: - Probe: EX3DV4 - SN7729; ConvF(9.76, 10.11, 9.77); Calibrated: 2024-01-22 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1691; Calibrated: 2024-04-19 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2022 - Measurement Software: 16.4.0.5005 Area Scan (120.0 mm x 210.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.783 W/kg; SAR (10g) = 0.487 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm; Graded Ratio:1.4 Power Drift = -0.01 dB SAR (1g) = 0.708 W/kg; SAR (10g) = 0.411 W/kg; Smallest distance from peaks to all points 3dB below is 5.8 mm Ratio of SAR at M2 to SAR at M1 = 66.1 % Date: 2024-06-05 02_LTE Band 13_10M_QPSK_1RB_0Offset_Right Cheek_0mm_Ch23230 Communication System: Band 13; Frequency: 782.000 Medium: HSL. Medium parameters used: f= 782.000 MHz; σ= 0.911 S/m; ε r = 41.1 Ambient Temperature: 23.3°C; Liquid Temperature: 22.8°C DASY6 Configuration: - Probe: EX3DV4 - SN7729; ConvF(9.76, 10.11, 9.77); Calibrated: 2024-01-22 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1691; Calibrated: 2024-04-19 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2022 - Measurement Software: 16.4.0.5005 Area Scan (120.0 mm x 210.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.776 W/kg; SAR (10g) = 0.486 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm; Graded Ratio:1.5 Power Drift = 0.14 dB SAR (1g) = 0.644 W/kg; SAR (10g) = 0.401 W/kg; Smallest distance from peaks to all points 3dB below is 6.1 mm Ratio of SAR at M2 to SAR at M1 = 65.2 % Date: 2024-06-07 03_GSM850_GPRS (4 Tx slots)_Right Cheek_0mm_Ch128 Communication System: GSM 850; Frequency: 824.200 Medium: HSL. Medium parameters used: f= 824.200 MHz; σ= 0.914 S/m; ε r = 41.6 Ambient Temperature: 23.1°C; Liquid Temperature: 22.6°C DASY6 Configuration: - Probe: EX3DV4 - SN7729; ConvF(9.83, 9.58, 9.35); Calibrated: 2024-01-22 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1691; Calibrated: 2024-04-19 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2022 - Measurement Software: 16.4.0.5005 Area Scan (120.0 mm x 210.0 mm): Measurement Grid: 15.0 mm x 15.0 mm SAR (1g) = 0.645 W/kg; SAR (10g) = 0.401 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm; Graded Ratio:1.5 Power Drift = -0.08 dB SAR (1g) = 0.702 W/kg; SAR (10g) = 0.385 W/kg; Smallest distance from peaks to all points 3dB below is 5.8 mm Ratio of SAR at M2 to SAR at M1 = 66.8 % Date: 2024-06-07 04_WCDMA V_RMC 12.2Kbps_Right Cheek_0mm_Ch4132 Communication System: Band 5; Frequency: 826.400 Medium: HSL. Medium parameters used: f= 826.400 MHz; σ= 0.893 S/m; ε r = 41.2 Ambient Temperature: 23.1°C; Liquid Temperature: 22.9°C DASY6 Configuration: - Probe: EX3DV4 - SN7729; ConvF(9.83, 9.58, 9.35); Calibrated: 2024-01-22 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1691; Calibrated: 2024-04-19 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2022 - Measurement Software: 16.4.0.5005 Area Scan (120.0 mm x 210.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.641 W/kg; SAR (10g) = 0.423 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm; Graded Ratio:1.5 Power Drift = -0.06 dB SAR (1g) = 0.704 W/kg; SAR (10g) = 0.395 W/kg; Smallest distance from peaks to all points 3dB below is 7.2 mm Ratio of SAR at M2 to SAR at M1 = 71.0 % Date: 2024-06-07 05_LTE Band 26_15M_QPSK_1RB_0Offset_Right Cheek_0mm_Ch26865 Communication System: Band 26; Frequency: 831.500 Medium: HSL. Medium parameters used: f= 831.500 MHz; σ= 0.898 S/m; ε r = 41.3 Ambient Temperature: 23.1°C; Liquid Temperature: 22.9°C DASY6 Configuration: - Probe: EX3DV4 - SN7729; ConvF(9.83, 9.58, 9.35); Calibrated: 2024-01-22 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1691; Calibrated: 2024-04-19 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2022 - Measurement Software: 16.4.0.5005 Area Scan (120.0 mm x 210.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.717 W/kg; SAR (10g) = 0.478 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm; Graded Ratio:1.5 Power Drift = 0.11 dB SAR (1g) = 0.691W/kg; SAR (10g) = 0.482 W/kg; Smallest distance from peaks to all points 3dB below is 6.8 mm Ratio of SAR at M2 to SAR at M1 = 65.3 % Date: 2024-06-07 06_FR1 n26_20M_QPSK_1RB_1Offset_Right Cheek_0mm_Ch166300 Communication System: Band n26; Frequency: 831.500 Medium: HSL. Medium parameters used: f= 831.500 MHz; σ= 0.898 S/m; ε r = 41.3 Ambient Temperature: 23.1°C; Liquid Temperature: 22.6°C DASY6 Configuration: - Probe: EX3DV4 - SN7729; ConvF(9.83, 9.58, 9.35); Calibrated: 2024-01-22 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1691; Calibrated: 2024-04-19 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2022 - Measurement Software: 16.4.0.5005 Area Scan (120.0 mm x 210.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.757 W/kg; SAR (10g) = 0.465 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm; Graded Ratio:1.5 Power Drift = -0.06 dB SAR (1g) = 0.684 W/kg; SAR (10g) = 0.411 W/kg; Smallest distance from peaks to all points 3dB below is 5.2 mm Ratio of SAR at M2 to SAR at M1 = 63.6 % Date: 2024-06-09 07_WCDMA IV_RMC 12.2Kbps_Left Cheek_0mm_Ch1413 Communication System: Band 4; Frequency: 1732.600 Medium: HSL. Medium parameters used: f= 1732.600 MHz; σ= 1.40 S/m; ε r = 40.8 Ambient Temperature: 23.3°C; Liquid Temperature: 22.6°C DASY6 Configuration: - Probe: EX3DV4 - SN7729; ConvF(8.64, 8.47, 8.41); Calibrated: 2024-01-22 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1691; Calibrated: 2024-04-19 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2022 - Measurement Software: 16.4.0.5005 Area S…

Text truncated - open the document above for the full version.

RF Exposure Info

Date: 2024-06-17 44_FR1 n78_100M_QPSK_1RB_1Offset_Right Side_5mm_Ch633332 Communication System: Band n78; Frequency: 3499.980 Medium: HSL. Medium parameters used: f= 3499.980 MHz; σ= 2.78 S/m; ε r = 38.9 Ambient Temperature: 23.1°C; Liquid Temperature: 22.9°C DASY6 Configuration: - Probe: EX3DV4 - SN7729; ConvF(7.33, 7.26, 7.22); Calibrated: 2024-01-22 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1691; Calibrated: 2024-04-19 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2022 - Measurement Software: 16.4.0.5005 Area Scan (48.0 mm x 200.0 mm): Measurement Grid: 10.0 mm x 10.0 mm SAR (1g) = 1.01 W/kg; SAR (10g) = 0.305 W/kg; Zoom Scan (28.0 mm x 28.0 mm x 28.0 mm): Measurement Grid: 4.0 mm x 4.0 mm x 1.4 mm; Graded Ratio:1.4 Power Drift = 0.02 dB SAR (1g) = 1.04 W/kg; SAR (10g) = 0.241 W/kg; Smallest distance from peaks to all points 3dB below is 4.3 mm Ratio of SAR at M2 to SAR at M1 = 64.5 % Date: 2024-06-13 45_WLAN2.4GHz_802.11b 1Mbps_Right Side_5mm_Ch1 Communication System: IEEE 802.11b WiFi 2.4 GHz (DSSS, 1 Mbps); Frequency: 2412.000 MHz; Duty Cycle: 1:1 Medium: Head Simulating Liquid Medium parameters used: f= 2412.000 MHz; σ= 1.80 S/m; ε r = 37.5 Ambient Temperature: 23.2°C; Liquid Temperature: 22.7°C DASY6 Configuration: - Probe: EX3DV4 - SN7764; ConvF(8.03, 8.03, 8.03); Calibrated: 2023-10-05 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1691; Calibrated: 2024-04-19 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2022; Section: Flat - Measurement Software: 16.4.0.5005 Area Scan (48.0 mm x 210.0 mm): Measurement Grid: 8.0 mm x 15.0 mm SAR (1g) = 0.356 W/kg; SAR (10g) = 0.155 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 5.0 mm x 5.0 mm x 1.5 mm Power Drift = -0.17 dB SAR (1g) = 0.354 W/kg; SAR (10g) = 0.154 W/kg Smallest distance from peaks to all points 3 dB below = 5.6 mm Ratio of SAR at M2 to SAR at M1 = 76.8 % Date: 2024-06-13 46_Bluetooth_1Mbps_Top Side_5mm_Ch39 Communication System: IEEE 802.15.1 Bluetooth (GFSK, DH5); Frequency: 2441.000 MHz; Duty Cycle: 1:1.302 Medium: Head Simulating Liquid Medium parameters used: f= 2441.000 MHz; σ= 1.83 S/m; ε r = 37.5 Ambient Temperature: 23.8°C; Liquid Temperature: 22.8°C DASY6 Configuration: - Probe: EX3DV4 - SN7764; ConvF(8.03, 8.03, 8.03); Calibrated: 2023-10-05 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1691; Calibrated: 2024-04-19 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2022; Section: Flat - Measurement Software: 16.4.0.5005 Area Scan (48.0 mm x 120.0 mm): Measurement Grid: 8.0 mm x 15.0 mm SAR (1g) = 0.164 W/kg; SAR (10g) = 0.104 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 5.0 mm x 5.0 mm x 1.5 mm Power Drift = 0.03 dB SAR (1g) = 0.159 W/kg; SAR (10g) = 0.092 W/kg Smallest distance from peaks to all points 3 dB below = 5.0 mm Ratio of SAR at M2 to SAR at M1 = 79.2 % Date: 2024-06-19 47_WLAN5GHz_802.11n-HT40 MCS0_Right Side_5mm_Ch46 Communication System: WLAN 5GHz; Frequency: 5230.000 MHz;Duty Cycle: 1:1.067 Medium: HSL. Medium parameters used: f= 5230.000 MHz; σ= 4.51 S/m; ε r = 36.2 Ambient Temperature: 23.3°C; Liquid Temperature: 22.7°C DASY6 Configuration: - Probe: EX3DV4 - SN7729; ConvF(5.99, 5.85, 5.81); Calibrated: 2024-01-22 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1691; Calibrated: 2024-04-19 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2022 - Measurement Software: 16.4.0.5005 Area Scan (48.0 mm x 200.0 mm): Measurement Grid: 8.0 mm x 10.0 mm SAR (1g) = 0.365 W/kg; SAR (10g) = 0.119 W/kg; Zoom Scan (24.0 mm x 22.0 mm x 22.0 mm): Measurement Grid: 4.0 mm x 4.0 mm x 1.4 mm; Graded Ratio:1.4 Power Drift = 0.11 dB SAR (1g) = 0.451 W/kg; SAR (10g) = 0.133 W/kg; Smallest distance from peaks to all points 3dB below is 6.1 mm Ratio of SAR at M2 to SAR at M1 = 64.1 % Date: 2024-06-23 48_WLAN5GHz_802.11ac-VHT80 MCS0_Right Side_5mm_Ch155 Communication System: IEEE 802.11ax (80MHz, MCS0, 90pc duty cycle); Frequency: 5775.000 MHz; Duty Cycle: 1:1.145 Medium: Head Simulating Liquid Medium parameters used: f= 5775.000 MHz; σ= 5.20 S/m; ε r = 35.1 Ambient Temperature: 23.8°C; Liquid Temperature: 22.8°C DASY6 Configuration: - Probe: EX3DV4 - SN7729; ConvF(5.42, 5.2, 5.18); Calibrated: 2024-01-22 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1691; Calibrated: 2024-04-19 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2022 - Measurement Software: 16.4.0.5005 Area Scan (48.0 mm x 200.0 mm): Measurement Grid: 8.0 mm x 10.0 mm SAR (1g) = 0.427 W/kg; SAR (10g) = 0.154 W/kg; Zoom Scan (22.0 mm x 22.0 mm x 22.0 mm): Measurement Grid: 4.0 mm x 4.0 mm x 1.4 mm Power Drift = 0.15 dB SAR (1g) = 0.363 W/kg; SAR (10g) = 0.136 W/kg Smallest distance from peaks to all points 3 dB below = 4.9 mm Ratio of SAR at M2 to SAR at M1 = 65.5 % Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/6/3 49_LTE Band 12_10M_QPSK_1RB_0Offset_Back_5mm_Ch23095 Communication System: UID 0, LTE-FDD (0); Frequency: 707.5 MHz;Duty Cycle: 1:1 Medium: HSL_750 Medium parameters used: f = 707.5 MHz; σ = 0.885 S/m; ε = 41.296; ρ = 1000 r 3 kg/m Ambient Temperature:23.3 °C; Liquid Temperature:22.6 °C DASY5 Configuration: - Probe: EX3DV4 - SN3857; ConvF(9.21, 8.75, 9.15); Calibrated: 2024/1/22 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: SAM Twin Phantom; Type: SAM Twin; Serial: TP-1697 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (81x141x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 1.46 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 16.10 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 1.73 W/kg SAR(1 g) = 0.783 W/kg; SAR(10 g) = 0.383 W/kg Smallest distance from peaks to all points 3 dB below = 9.6 mm Ratio of SAR at M2 to SAR at M1 = 38% Maximum value of SAR (measured) = 1.25 W/kg 0 dB = 1.25 W/kg = 0.97 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing…

Text truncated - open the document above for the full version.

RF Exposure Info

Date: 2024-05-28 System Check_Head_750MHz DUT:D750V3 - SN:1087 Communication System: ; Frequency: 750.000 Medium: HSL. Medium parameters used: f= 750.000 MHz; σ= 0.905 S/m; ε r = 42.7 Ambient Temperature: 23.1°C; Liquid Temperature: 22.8°C DASY6 Configuration: - Probe: EX3DV4 - SN7706; ConvF(9.34, 10.73, 9.7); Calibrated: 2024-01-24 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1303; Calibrated: 2023-11-20 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2024 - Measurement Software: 16.4.0.5005 Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.436 W/kg; SAR (10g) = 0.291 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm; Graded Ratio:1.5 Power Drift = 0.02 dB SAR (1g) = 0.435 W/kg; SAR (10g) = 0.292 W/kg; Smallest distance from peaks to all points 3dB below is 19.7 mm Ratio of SAR at M2 to SAR at M1 = 88.7 % Date: 2024-05-29 System Check_Head_835MHz DUT:D835V2 - SN:4d091 Communication System: ; Frequency: 835.000 Medium: HSL. Medium parameters used: f= 835.000 MHz; σ= 0.924 S/m; ε r = 41.4 Ambient Temperature: 23.1°C; Liquid Temperature: 22.9°C DASY6 Configuration: - Probe: EX3DV4 - SN7706; ConvF(9.26, 10.67, 9.28); Calibrated: 2024-01-24 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1303; Calibrated: 2023-11-20 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2024 - Measurement Software: 16.4.0.5005 Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 0.508 W/kg; SAR (10g) = 0.317 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm; Graded Ratio:1.5 Power Drift = 0.01 dB SAR (1g) = 0.505 W/kg; SAR (10g) = 0.328 W/kg; Smallest distance from peaks to all points 3dB below is 15.6 mm Ratio of SAR at M2 to SAR at M1 = 89.7 % Date: 2024-05-30 System Check_Head_1750MHz DUT:D1750V2 - SN:1090 Communication System: ; Frequency: 1750.000 Medium: HSL. Medium parameters used: f= 1750.000 MHz; σ= 1.35 S/m; ε r = 40.1 Ambient Temperature: 23.4°C; Liquid Temperature: 22.7°C DASY6 Configuration: - Probe: EX3DV4 - SN7706; ConvF(7.87, 9.06, 8.09); Calibrated: 2024-01-24 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1303; Calibrated: 2023-11-20 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2024 - Measurement Software: 16.4.0.5005 Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 1.99 W/kg; SAR (10g) = 1.00 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm; Graded Ratio:1.5 Power Drift = 0.01 dB SAR (1g) = 1.99 W/kg; SAR (10g) = 1.01 W/kg; Smallest distance from peaks to all points 3dB below is 9.6 mm Ratio of SAR at M2 to SAR at M1 = 82.4 % Date: 2024-05-31 System Check_Head_1900MHz DUT:D1900V2 - SN:5d118 Communication System: ; Frequency: 1900.000 Medium: HSL. Medium parameters used: f= 1900.000 MHz; σ= 1.43 S/m; ε r = 39.8 Ambient Temperature: 23.1°C; Liquid Temperature: 22.6°C DASY6 Configuration: - Probe: EX3DV4 - SN7706; ConvF(7.77, 8.97, 7.88); Calibrated: 2024-01-24 - Sensor-Surface: 1.4 mm - Electronics: DAE4 Sn1303; Calibrated: 2023-11-20 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 2024 - Measurement Software: 16.4.0.5005 Area Scan (40.0 mm x 90.0 mm): Measurement Grid: 10.0 mm x 15.0 mm SAR (1g) = 2.01 W/kg; SAR (10g) = 1.06 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm; Graded Ratio:1.5 Power Drift = 0.01 dB SAR (1g) = 2.09 W/kg; SAR (10g) = 1.10 W/kg; Smallest distance from peaks to all points 3dB below is 9.2 mm Ratio of SAR at M2 to SAR at M1 = 83.7 % Date: 2024-06-01 System Check_Head_2450MHz DUT:D2450V2 - SN:1095 Communication System: ; Frequency: 2450.000 Medium: HSL. Medium parameters used: f= 2450.000 MHz; σ= 1.86 S/…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jeff Narducci(Director Product Compliance)
[email protected]847-687-6928Fax: 847-687-6928

Test Firm

Sporton International Inc. (Kunshan)Jim Tsai
[email protected]+86 0512 57900158

Technical Specifications

#Rule PartsFrequency RangePower Output
415E5.75 GHz - 5.83 GHz127.40 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to belt-clips and holsters that have no metallic components in the assembly and cause the device to operate with the minimum separation distance of 5.0 mm, as described in this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), simultaneous transmission and product specific (10g SAR) exposure conditions are 1.12 W/kg, 1.18 W/kg, 0.64 W/kg, 1.59 W/kg and 3.18 W/kg, respectively. This device supports 20, 40 and 80 MHz bandwidths modes.

Other Applications from Motorola Mobility LLC

IHDT6AC8

Qi2 wireless charger

Sep 15, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
IHDT6AC6

Wireless Earphones

Sep 14, 2026

Equipment Class

JAB - Part 15 Class B Digital Device
IHDT6AC7

Smart Watch

Sep 11, 2026

Equipment Class

JAB - Part 15 Class B Digital Device
IHDT56AX5

Mobile Cellular Phone

Aug 28, 2026

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
IHDT56AW9

Smart Watch

May 12, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX