FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Motorola Mobility LLC/
  3. IHDT56CM1

IHDT56CM1Portable Cellular/ PCS Transceiver (AMPS/CDMA)

Motorola Mobility LLC
Portable Cellular/ PCS Transceiver (AMPS/CDMA) - FCC ID IHDT56CM1 - Motorola Mobility LLC
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Dec 10, 2002
Application Purpose
Original Equipment
Date of Application
Dec 09, 2002
Equipment Note
Portable Cellular/ PCS Transceiver (AMPS/CDMA)
Frequency Range
1851.25000000 - 1908.75000000
Company
Motorola Mobility LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗

RF Exposure Info

↗
↗
↗
↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

APPLICANT: MOTOROLA, INC.FCC ID: IHDT56CM1 EXHIBIT 8 INSTRUCTION MANUAL A preliminary draft copy of the Users Manual follows: P R E L IMI N A RY Motorola V60x (Phoenix) CDMA R1.2 Verizon Mobile Phone User Guide Preliminary Review Draft August 2, 2002 P R E L IMI N A R Y 1 P R E L IMI N A RY Welcome Welcome to the world of Motorola digital wireless communications! We are pleased that you have chosen the Motorola V60x wireless phone. Earpiece Headset Jack Insert headset accessory for hands-free use. Status Light See incoming call and service status. Vo l u m e Key s Adjust earpiece and ringer volume. Smart Key Select menu items, send and end calls. Vo i c e Key Record voice notes, phonebook and shortcut names. Display Microphone Accessory Connector Port Insert charger and phone accessories. Power Key Right Soft Key Perform functions identified by right display prompt. Menu Key End Key End phone calls, exit menu system. Scroll Key Move through menus and lists. Left Soft Key Perform functions identified by left display prompt. Send Key Send and answer calls, view recent dialed calls list. 2 P R E L IMI N A R Y Personal Communications Sector 600 North U.S. Highway 45 Libertyville, Illinois 60048 1-800-331-6456 (United States) 1-888-390-6456 (TTY/TDD United States) 1-800-461-4575 (Canada) www.motorola.com (United States) www.motorola.ca (Canada) MOTOROLA, the Stylized M Logo and all other trademarks indicated as such herein are trademarks of Motorola, Inc. ® Reg. U.S. Pat. & Tm. Off. TrueSync, Sidekick, Starfish, and the Stylized Starfish Logo are registered trademarks of Starfish Software, Inc., a wholly owned independent subsidiary of Motorola, Inc. All other product or service names are the property of their respective owners. © 2001, 2002 Motorola, Inc. All rights reserved. Software Copyright Notice The Motorola products described in this manual may include copyrighted Motorola and third party software stored in semiconductor memories or other media. Laws in the United States and other countries preserve for Motorola and third party software providers certain exclusive rights for copyrighted software, such as the exclusive rights to distribute or reproduce the copyrighted software. Accordingly, any copyrighted software contained in the Motorola products may not be modified, reverse-engineered, distributed, or reproduced in any manner to the extent allowed by law. Furthermore, the purchase of the Motorola products shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents, or patent applications of Motorola or any third party software provider, except for the normal, non-exclusive, royalty-free license to use that arises by operation of law in the sale of a product. Manual number: XXXX-O Cover number:8988485L49-O 3 P R E L IMI N A RY Menu Map Main Menu • Recent Calls • Received Calls • Dialed Calls • Notepad • Call Times • Phonebook • Datebook •Radio* • Messages •Voicemail • Create Message •Inbox • Outbox • Quick Notes •Drafts • Browser Alerts •Shortcuts • Voice Notes •Browser • Calculator • Picture Viewer •GetItNow •Settings (see next page) Shortcuts Change display zoom: Press M, then press and hold M Display my phone number: Press M# Dial voicemail number: Press and hold 1 Go to dialed calls list: Press N Exit menu system: Press O * This is the standard phone menu layout. Menu organization and feature names may vary on your phone. Not all features may be available for all users. For example, the Radio option (left) is available only when the optional FM Stereo Radio Headset accessory is plugged into your phone. 4 P R E L IMI N A R Y Settings Menu •Ring Styles •Style •Style Detail • My Tones • Phone Status •My Tel. Number • Active Line • Battery Meter • Other Information •Browser Setup • In-Call Setup • In-Call Timer • Answer Options • Security • Phone Lock • Lock Application • Restrict Calls •New Passwords • Location • Other Settings • Initial Setup • Time and Date • Auto PIN Dial • Auto Redial • Backlight • Status Light •Zoom • TTY Setup •Scroll • Animation • Language • Contrast •DTMF •Master Reset • Master Clear • Personalize •Main Menu •Keys •Greeting • Banner • Connection •Network • Car Settings • Headset 5 P R E L IMI N A RY Contents Menu Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Safety and General Information. . . . . . . . . . . . . . . . . . . 11 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 What’s in the Box?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Installing the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Charging the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Changing the Convertible Covers . . . . . . . . . . . . . . . . . 19 Turning Your Phone On . . . . . . . . . . . . . . . . . . . . . . . . . 21 Making a Call. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Ending a Call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Answering a Call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Seeing Your Phone Number . . . . . . . . . . . . . . . . . . . . . 22 About Your Phone. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Using the Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Zooming In and Out. . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Using the Status Light . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Adjusting Volume. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Using the Smart Key . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Using the External Display . . . . . . . . . . . . . . . . . . . . . . 27 Battery Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Making and Answering Calls. . . . . . . . . . . . . . . . . . . . . 30 R…

Text truncated - open the document above for the full version.

Users Manual

Date: January 20, 2003 Subject: Request for additional information (FCC ID: IHDT56CM1) Reference: Application Received12/23/2002 Correspondence Reference Number:6421 731 Confirmation Number:TC269210 Date of Original Email:1/3/2003 Prepared by: Steven Hauswirth Motorola Personal Communications Sector Product Safety Laboratory Harvard, Illinois Andrew Bachler, Principal Staff Engineer Motorola Personal Communications Sector Libertyville, Illinois Summary of FCC request for additional information: Please confirm that no accessory covers mentioned on page 20 of the user manual contain metallic components/paint. Response: All covers (both optional accessories and the standard cover that ships with the device) are identical in composition. Each cover is metal and is covered with a non- metallic paint. The paint style and color varies.

Attestation Statements

Applicant: Motorola, INC.FCC ID: IHDT56CM1 Exhibit 2 1 SPECIFICATION COMPLIANCE STATEMENT Engineer-in-Charge Equipment Authorization Branch Federal Communications Commission We hereby certify that this transmit and receive equipment (FCC ID: IHDT56CM1) for dual mode mobile station cellular use is capable of compliance with TIA/EIA-95-B Mobile Station-Base Station Compatibility Standard for Dual-Mode Spread Spectrum Systems, December 1998. Steve Geske Engineering Manager Cellular Subscriber Equipment Mike Cruz Director of Engineering Cellular Subscriber Equipment Applicant: Motorola, INC.FCC ID: IHDT56CM1 Exhibit 2 2 STATEMENT OF CERTIFICATION The technical data supplied with this application, having been taken under my supervision is hereby duty certified. SIGNATURE: (signed) Steve Geske NAME: Steve Geske DATE: 11/20/02 POSITION: Engineering Manager I hereby certify that the above application was prepared under my direction and that to the best of my knowledge and belief, the facts set forth in the application and accompanying technical data are true and correct: SIGNATURE: (signed) Mike Cruz NAME: Mike Cruz DATE: 11/20/02 POSITION: Director of Engineering APPLICANT: MOTOROLA, INC. FCC ID: IHDT56CM1 MOTOROLA CONFIDENTIAL PROPRIETARY Exhibit 12I INFORMATION REGARDING ELECTRONIC SERIAL NUMBER (ESN) PROTECTION This cellular transceiver uses a microprocessor to control its call processing operation. This microprocessor accesses a programmable memory area, which is used to store an encrypted data block that contains the Electronic Serial Number (ESN). A proprietary scheme is used to create this data block whereby it is encrypted using methods similarto known public key cryptography methods. It is emphasized that the method used is similar to but different from these known methods and the actual method used is kept proprietary to provide the essential security for the ESN. Also, the transceiver will not operate unless the microprocessor is able to decrypt this data block correctly. Access is controlled to both the method of encryption and to the production/repair equipment that has the ability to program the encrypted data block. APPLICANT: MOTOROLA, INC. FCC ID: IHDT56CM1 MOTOROLA CONFIDENTIAL PROPRIETARY Exhibit 12K 911 Call Processing Method Compliance Statement Method Used The Motorola CDMA phone uses the “Automatic A/B Roaming-IR” method for providing Enhanced 911 Emergency Calling support in compliance with the FCC mandate. User Interface While in the process of attempting to complete a 911 call the Motorola CDMA phone provides both audible and visual feedback to the caller per the FCC order. The display of the phone will show the text “Connecting Emergency” and a feedback tone of three short beeps sounded at 5- second intervals will indicate that the phone is attempting to find a carrier system to complete the call. When the call has been successfully established, the sounding of the feedback tone is terminated and the content of the display is changed to the normal in call display. System Description When a 911 call is initiated, the Motorola CDMA phone ignores all programmed restrictions with regard to which systems, both analog and digital are useable for completing the call. If the Motorola CDMA phone has acquired service on a system at the time the 911 call is initiated it will attempt to complete the call using that system. If the phone is not in service on a system it will initially attempt to complete the call using any available system it can find, which may exist on any frequency band or mode, supported by the handset. The phone’ s scanning algorithm ensures that both analog sides are scanned at least once approximately every 15 seconds. The phone will continue attempting to complete the 911 call until the call is completed, the user has ended the call, or the battery is exhausted.

Cover Letter(s)

APPLICANT: MOTOROLAFCC ID: IHDT56CM1 Exhibit 13 November 20, 2002 CONFIDENTIALITY REQUEST CONTAINED WITHIN Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re: Application for Cellular/PCS Transceiver Certification Gentlemen: Application: Motorola, Inc., Personal Communications Sector, 600 N. U.S. Highway 45, Libertyville, Illinois 60048-1286 herein submits: Application for Equipment Authorization for Certification of a Cellular Transceiver, FCC ID: IHDT56CM1. Motorola is also the manufacturer of this equipment. Confidentiality: Pursuant to Section 0.459 of the Commission's rules (CFR 47), Motorola requests confidentiality for portions of the material contained in this application and that the identified material be withheld from public inspection following the grant of this authorization. This material contains Motorola's trade secrets and confidential information that Motorola does not customarily release to the public and which is otherwise not generally available to the public. Confidentiality is requested for the following exhibits:  Exhibit 4 Block Diagrams  Exhibit 5 Schematics  Exhibit 12 Operational Description Description: This equipment has the capability to operate in the conventional Analog Cellular standard in the 800 MHz cellular band, and the Digital CDMA standard in both the 800 MHz and the PCS bands, as outlined in EIA/TIA IS-95-A "Mobile Station – Base Station Compatibility Standard for Dual- Mode Wideband Spread Spectrum Cellular System”. Technical details for this alternate cellular technology (permitted under the cellular service option provisions in Section 22.933 of the Commission's rules) related to Type Acceptance of this equipment, as noted in paragraphs 31 and 32 of the Report and Order in FCC GEN. Docket No. 87-390, are detailed in Exhibit 12. Contact Information: Please contact me by telephone at (847) 523-6167, or by e-mail ([email protected]), if there are questions or additional information needed concerning this filing. Regards, Andrew J. Bachler FCC Liaison Cellular Subscriber Sector 600 N. U.S. Highway 45 Libertyville, IL 60048-5343

Cover Letter(s)

February 14, 2003 Federal Communications Commission Equipment Approval Services 7435 Oakland Mills Road Columbia, MD 21046 Attn: Mr. Martin Perrine SUBJECT: Motorola, Inc. FCC ID: IHDT56CM1 731 Confirmation No.: TC269210 Correspondence Reference No.: 6906 Request for Tech. Info.: 2/12/03 Dear Martin: Transmitted herewith, on behalf of Motorola, Inc., is an amendment provided in response to the request for technical information dated February 12, 2003. 1. The response for CRN 6421 was double-checked and is correct. Motorola’s response confirms that no accessory covers mentioned on page 20 of the user’s manual contain metallic components/paint. We trust this information is sufficient to resolve FCC questions in this application. If you have any further questions, please do not hesitate to contact us. Thank You, cc: Motorola, Inc.

External Photos

APPLICANT: MOTOROLA, INC. FCC ID: IHDT56CM1 EXHIBIT 3 Front View with Flip Open Rear View with Battery Removed to Show Equipment ID Label

ID Label/Location Info

APPLICANT: MOTOROLA INC. FCC ID: IHDT56CM1 EXHIBIT 1 FCC IDENTIFICATION (NAMEPLATE) INFORMATION The FCC label shown is representative of the label that will appear on the radio when in production. It will be placed on the outside of the equipment as shown in Exhibit 3. Other information may also be included on this label. FCC ID: IHDT56CM1

Internal Photos

APPLICANT: MOTOROLA, INC. FCC ID: IHDT56CM1 EXHIBIT 9 Front View (Shields Removed) Rear View (Shields Removed) 1 of 3 APPLICANT: MOTOROLA, INC. FCC ID: IHDT56CM1 EXHIBIT 9 Rear View (with Shields) 2 of 3 Front View (with Shields) APPLICANT: MOTOROLA, INC. FCC ID: IHDT56CM1 EXHIBIT 9 3 of 3 Rear Housing Internal View Front Housing Internal View Keypad PCB Keypad

Parts List/Tune Up Info

APPLICANT: MOTOROLA, INC. FCC ID: IHDT56CM1 EXHIBIT 9 Front View (Shields Removed) Rear View (Shields Removed) 1 of 3 APPLICANT: MOTOROLA, INC. FCC ID: IHDT56CM1 EXHIBIT 9 Rear View (with Shields) 2 of 3 Front View (with Shields) APPLICANT: MOTOROLA, INC. FCC ID: IHDT56CM1 EXHIBIT 9 3 of 3 Rear Housing Internal View Front Housing Internal View Keypad PCB Keypad

RF Exposure Info

APPLICANT: MOTOROLA, INC. FCC ID: IHDT56CM1 E E x x h h i i b b i i t t 1 1 1 1 P P a a g g e e 1 1 Exhibit 11: SAR Test Report IHDT56CM1 Date of test: Date of Report: 08/27/2002-09/06/2002 09/25/2002 Laboratory: Motorola Personal Communications Sector Product Safety & Compliance Laboratory 2001 N. Division Room: AS228 Harvard, Illinois 60033 Test Responsible: Firass Badaruzzaman SAR Engineer Accreditation: This laboratory is accredited to ISO/IEC 17025-1999 to perform the following electromagnetic exposure tests: System Validation & Interlaboratory Comparison Simulated Tissue Specifications and Procedure EME Cellular Phone Testing Procedure On the following types of products: Wireless Communications Devices (Examples): Two Way Radios; Portable Phones (including Cellular, Licensed Non-Broadcast and PCS); Low Frequency Readers; and Pagers A2LA certificate #1651-01 Statement of Compliance: Motorola declares under its sole responsibility that portable cellular telephone FCC ID IHDT56CM1 to which this declaration relates, is in conformity with the appropriate General Population/Uncontrolled RF exposure standards, recommendations and guidelines (FCC 47 CFR §2.1093). It also declares that the product was tested in accordance with the appropriate measurement standards, guidelines and recommended practices. Any deviations from these standards, guidelines and recommended practices are noted below: (none) ‘ ©Motorola, Inc. 2002 This test report shall not be reproduced except in full, without written approval of the laboratory. The results and statements contained herein relate only to the items tested. The names of individuals involved may be mentioned only in connection with the statements or results from this report. Motorola encourages all feedback, both positive and negative, on this test report. APPLICANT: MOTOROLA, INC. FCC ID: IHDT56CM1 E E x x h h i i b b i i t t 1 1 1 1 P P a a g g e e 2 2 Table of Contents 1) Introduction 3 2) Description of the Device Under Test 3 Antenna description 3 Device description 3 3) Test Equipment 3 3.1 Dosimetric system 3 3.2 Additional equipment used 4 4) Electrical parameters of the tissue simulating liquid 4 5) System Accuracy Verification 5 6) Test Results 6 6.1 Head Adjacent Test Results 6 6.2 Body-Worn Test Results 9 References: Appendix 1: SAR distribution comparison for the system accuracy verification 11 Appendix 2: SAR distribution plots for Phantom Head Adjacent Use 12 Appendix 3: SAR distribution plots for Body Worn Configuration 15 Appendix 4. Probe Calibration Certificate 17 Appendix 5. Dipole Characterization Certificate 18 Appendix 6: Measurement Uncertainty Budget 19 Appendix 7. Photographs of the device under test 22 APPLICANT: MOTOROLA, INC. FCC ID: IHDT56CM1 E E x x h h i i b b i i t t 1 1 1 1 P P a a g g e e 3 3 1. Introduction The Motorola Personal Communications Sector Product Safety Laboratory has performed measurements of the maximum potential exposure to the user of portable cellular phone (FCC ID IHDT56CM1). The Specific Absorption Rate (SAR) of this product was measured. The portable cellular phone was tested in accordance with FCC OET Bulletin 65 Supplement C 01-01. 2. Description of the Device Under Test Antenna description Type Helix Location Right Side Length 25 mm Dimensions Width 6 mm Configuration Stubby Device description FCC ID Number IHDT56CM1 Serial number 77046963 Mode(s) of Operation 800 AMPS 800 CDMA 1900 PCS Modulation Mode(s) AMPS CDMA PCS Maximum Output Power Setting 27.80 dBm 25.00 dBm 25.00 dBm Duty Cycle 1:1 1:1 1:1 Transmitting Frequency Rang(s) 824.04 – 848.97 MHz 824.70 – 848.31 MHz 1851.25 – 1908.75 MHz Production Unit or Identical Prototype (47 CFR §2..908) Identical Prototype Device Category Portable RF Exposure Limits General Population / Uncontrolled 3. Test Equipment Used 3.1 Dosimetric System The Motorola Personal Communications Sector Product Safety & Compliance Laboratory utilizes a Dosimetric Assessment System (Dasy3™ v3.1d) manufactured by Schmid & Partner Engineering AG (SPEAG™), of Zurich Switzerland. The overall RSS uncertainty of the measurement system is ±11.7% (K=1) with an expanded uncertainty of ±23.0% (K=2). The measurement uncertainty budget is given in Appendix 6. The list of calibrated equipment used for the measurements is shown below. APPLICANT: MOTOROLA, INC. FCC ID: IHDT56CM1 E E x x h h i i b b i i t t 1 1 1 1 P P a a g g e e 4 4 Description Serial Number Cal Due Date DASY3 DAE V1 SN 385 22/05/2003 DASY3 DAE V1 SN 386 5/22/2003 E-Field Probe ETDV6 SN 1391 10/25/2002 E-Field Probe ETDV6 SN1503 11/16/2002 Dipole Validation Kit, DV900V2 SN 79 10/26/2002 S.A.M. Phantom used for 800MHz TP-1106 Dipole Validation Kit, DV1800V2 283 TR 1/5/2003 Dipole Validation Kit, DV1800V2 284 TR 1/5/2003 S.A.M. Phantom used for 1900MHz TP-1133 S.A.M. Phantom used for 1900MHz TP-1159 3.2 Additional Equipment Description Serial Number Cal Due Date Signal Generator HP8648C 3847A04822 11/14/2002 Power Meter E4419B GB39511088 01/18/2002 Power Sensor #1 - 8481A US39210918 02/11/2003 Power Sensor #2 - 8481A US39211006 05/02/2003 Network Analyzer HP8753ES US39171846 05/01/2003 Dielectric Probe Kit HP85070B US99360074 Description Serial Number Cal Due Date Signal Generator HP8648C 3847A04850 12/20/2002 Power Meter E4419B GB39510900 01/18/2003 Power Sensor #1 - 8481A US39211009 02/14/2003 Power Sensor #2 - 8481A US39211008 02/15/2003 Network Analyzer HP8753ES US39171846 05/01/2003 Dielectric Probe Kit HP85070B US99360074 4. Electrical parameters of the tissue simulating liquid Prior to conducting SAR measurements, the relative permittivity, ε r , and the conductivity, σ, of the tissue simulating liquids were measured with the HP85070 Dielectric Probe Kit These values, along with the temperature of the tissue simulate are shown in the table below. The recommended limits for maximum permittivity and minimum conductivity are also shown. These come from the Federal Communication Commission, OET Bulletin 65 Supplement…

Text truncated - open the document above for the full version.

RF Exposure Info

ET3DV6 SN:1503 DASY3 - Parameters of Probe: ET3DV6 SN:1503 Sensitivity in Free SpaceDiode Compression NormX2.25 μV/(V/m) 2 DCP X95mV NormY2.10 μV/(V/m) 2 DCP Y95mV NormZ1.95 μV/(V/m) 2 DCP Z95mV Sensitivity in Tissue Simulating Liquid Head450MHz ε r =40.4 ± 5% σ = 0.87 ± 5% mho/m ConvF X6.92 extrapolatedBoundary effect: ConvF Y6.92 extrapolatedAlpha0.31 ConvF Z6.92 extrapolatedDepth2.46 Head900MHz ε r =41.5 ± 5% σ = 0.97 ± 5% mho/m Head835MHz ε r =41.5 ± 5% σ = 0.90 ± 5% mho/m ConvF X6.36 ± 9.5% (k=2)Boundary effect: ConvF Y6.36 ± 9.5% (k=2)Alpha0.39 ConvF Z6.36 ± 9.5% (k=2)Depth2.42 Head1500MHz ε r =40.4 ± 5% σ = 1.23 ± 5% mho/m ConvF X5.61 interpolatedBoundary effect: ConvF Y5.61 interpolatedAlpha0.49 ConvF Z5.61 interpolatedDepth2.36 Head1800MHz ε r =40.0 ± 5% σ = 1.40 ± 5% mho/m Head1900MHz ε r =40.0 ± 5% σ = 1.40 ± 5% mho/m ConvF X5.24 ± 9.5% (k=2)Boundary effect: ConvF Y5.24 ± 9.5% (k=2)Alpha0.54 ConvF Z5.24 ± 9.5% (k=2)Depth2.33 Sensor Offset Probe Tip to Sensor Center2.7mm Optical Surface Detection1.6 ± 0.2mm Page 2 of 7

RF Exposure Info

1 Date: December 9, 2002 Subject: Request for additional information (FCC ID: IHDT56CM1) Reference: Logged-In Date:11/21/2002 Correspondence Reference Number:221205.IHD Confirmation Number:TC1378 Date of Original Email:12/05/2002 Prepared by: Steven Hauswirth Motorola Personal Communications Sector Product Safety Laboratory Harvard, Illinois Andrew Bachler, Principal Staff Engineer Motorola Personal Communications Sector Libertyville, Illinois 2 Summary of FCC request for additional information There was a request for additional information regarding Motorola’s SAR Test Report for Motorola portable cellular phone (FCC ID IHDT56CM1). The requested information is addressed below in the same numbering sequence received. 1) Please provide justification for the probe conversion factor used for 1900 MHz Body measurements per OET 65 Supp. C. Response: The calibration certificate for the probe utilized (probe SN1503), page 2 of 8 shows that the conversion factor for 1800MHz & 1900MHz head is 6.43 for probe SN1503. This is the value that was used for testing in the original filing. Since simulated tissue targets are the same for both 1800 & 1900 MHz head and the conversion factor for both 1800 & 1900 MHz head is the same (‘5.24’ for Probe SN1503), it is also true for body worn that both 1800 & 1900 MHz share the same conversion factor (‘4.9’ for Probe SN1503) since they share the same simulated tissue targets. This is demonstrated in all newly calibrated probes from SPEAG. These new calibration sheets show that the 1800MHz & 1900MHz body do share the common conversion factor. 2) Please provide the test configuration photo/sketch of body- worn position. Photograph or sketch provided must clearly show the distance between the body of the device and the flat phantom. Response: Please see photographs below of the test setup described in the original filing: 3 Figure 1. “Twin Tub” Body-Worn Measurement Phantoms and Fixture. 4 Figure 2. Underside of “Twin Tub” showing DUT placement locations. 5 Please see photographs shown below for the body worn configuration. Figure 3. DUT below “Twin Tub” Body-Worn Measurement Phantom 6 Figure 4. DUT below “Twin Tub” Body-Worn Measurement Phantom 7 Figure 5. Separation Distance of 25 mm from Tip of Antenna to Flat Phantom and 8 mm from the bottom of the clip when rotated +90 (Clockwise Direction) 3) Confirmation that identical serial numbers and power configuration was used for both EMC and SAR testing. Response: To maximize correlation of critical values listed on the grants, the following reported parameters were based on the same unit (identical serial number):  SAR values  Conducted power  Radiated power (EIRP) Other EMC related characteristics (frequency stability, occupied bandwidth, conducted and radiated spurs) were based on units of identical power configurations. 8 4) Confirmation that power was measured for each SAR test scan. Response: The complete set of conducted output power measurements was measured prior to the complete set of SAR measurements being performed. For each SAR measurement, the SAR was be checked at a reference location immediately before and after each SAR measurement to verify device output and SAR drifts. These drifts were reported in the original filing. 5) Statement explaining the second/cutoff hotspots which are evident on several 1900 MHz head/body SAR plots. Please provide additional test data fully measuring the second hotspot, as appropriate. Response: The Cheek Touch and Body-worn SAR measurements in the 1900MHz band showed two RF hot spots. The primary RF hot spot was used for the cube measurement to determine the SAR value. The peak within the 2 nd RF hot spot for these measurements was not within 2dB of the peak within the primary RF hot spot. Supplement C specifies that only “peaks within 2.0 dB (58.5%) of the highest peak identified by the interpolated data should be evaluated with a fine resolution volume scan to determine the highest one-gram averaged SAR”. 6) Confirmation that body-worn SAR with "back to phantom" is worst case compared with "face to phantom". Please clarify if testing was performed. Response: The DUT was tested with a body-worn accessory in the original filing. This accessory only allows the DUT to be held with the back of the product towards the phantom. Additional testing is not required. 7) Please correct page 4 of the equipment used listed in the SAR report (Exhibit 11). The Power Meter E4419B contains an expired date. Response: The table below has been corrected for all errors in the original equipment list. DescriptionSerial Number Cal Due Date Signal Generator HP8648CN120299-2310-Oct-04 Power Meter E4419BN120299-2718-Jan-03 Power Sensor #1 – E9301AN120299-2514-Feb-03 Power Sensor #2 - E9301AN120299-2815-Feb-03 Network Analyzer HP8753ESUS392209992-May-03 Dielectric Probe Kit HP85070C594146-01 9 8) The two statements contained in the confidential filing of Exhibit 12 Operational Description (ESN Exh. 12I and E911 Exh. 12K only ) will be uploaded as NOT CONFIDENTIAL as part of the Attestation Statements to avoid FCC requests for these documents (ESN Protection and 911 Call Processing). Please confirm. Response: Motorola confirms.

RF Exposure Info

Date: January 20, 2003 Subject: Request for additional information (FCC ID: IHDT56CM1) Reference: Application Received12/23/2002 Correspondence Reference Number:6421 731 Confirmation Number:TC269210 Date of Original Email:1/3/2003 Prepared by: Steven Hauswirth Motorola Personal Communications Sector Product Safety Laboratory Harvard, Illinois Andrew Bachler, Principal Staff Engineer Motorola Personal Communications Sector Libertyville, Illinois Summary of FCC request for additional information: Please confirm that no accessory covers mentioned on page 20 of the user manual contain metallic components/paint. Response: All covers (both optional accessories and the standard cover that ships with the device) are identical in composition. Each cover is metal and is covered with a non- metallic paint. The paint style and color varies.

Test Report

APPLICANT: MOTOROLA INC FCC ID: IHDT56CM1 EXHIBIT 6 PERSONAL COMMUNICATIONS SECTOR PRODUCT SAFETY AND COMPLIANCE EMC LABORATORY EMC TEST REPORT Test Report Number – 8042-1 Report Date – August 20, 2002 The test results contained herein relate only to the model(s) identified. It is the manufacturer’s responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical characteristics. As the responsible EMC Engineer, I hereby declare that the equipment tested as specified in this report conforms to the requirements indicated . SignatureName: _Kirby Munroe__ Title: Compliance Engineer Date : _ 8/20/2002____ This report must not be reproduced, except in full, without written approval from this laboratory. THIS REPORT MUST NOT BE USED TO CLAIM PRODUCT ENDORSEMENT BY A2LA OR ANY AGENCY OF THE U.S. GOVERNMENT. A2LA Certificate Number: 1846-01 APPLICANT: MOTOROLA INC FCC ID: IHDT56CM1 Test Report Number: 8042-1EXHIBIT 6 2 Table of Contents Description Page Test Report Details4 Applicable Standards4 Summary of Testing5 General and Special Conditions 5 Equipment and Cable Configurations5 Measuring Equipment and Calibration Information6 Measurement Procedures and Data RF Power Output 7 Radiated Power (ERP)8 Modulation Characteristics Transmit Audio Frequency Response9 Post Limiter Filter Attenuation9 Modulation Limiting vs. Modulation Input Voltage10 Occupied Bandwidth11 AMPS Unmodulated Carrier12 AMPS Supervisory Audio Tone12 AMPS Voice13 AMPS Signaling Tone13 AMPS 10kb/s Wideband Data14 CDMA 800 Reference Plot15 CDMA 800 Mid Band Plot15 CDMA 800 Lower Band Edge16 CDMA 800 Upper Band Edge16 CDMA 1900 Reference Plot17 CDMA 1900 Mid Band Plot17 CDMA 1900 Lower Band Edge18 CDMA 1900 Upper Band Edge18 Spurious Emissions at Antenna Terminals19 AMPS Tabular and Graphical Data20 AMPS Cellular Base Station Frequency Range Plot21 CDMA 800 Tabular and Graphical Data22 CDMA 800 Cellular Base …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jeff Narducci(Director Product Compliance)
[email protected]847-687-6928Fax: 847-687-6928

Test Firm

Motorola Inc.Jonathan Munroe
[email protected]561-739-2179Fax: 561-739-2131

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
424E1.85 GHz - 1.91 GHz355.00 mW1M25F9W150 Hz
Confidentiality
Long Term
Grant Notes
Output power listed is ERP for Part 22 and EIRP for Part 24. SAR compliance for body-worn operating configuration is limited to the specific belt-clip/holsters tested for this filing. End-users must be informed of the body-worn operating requirements requirements for satisfying RF exposure compliance. The highest reported SAR values are: Part 22-Head: 1.57 W/kg; Body-worn: 0.62 W/kg; Part 24-Head: 0.414 W/kg; Body-worn: 0.59 W/kg.

Other Applications from Motorola Mobility LLC

IHDT6AC8

Qi2 wireless charger

Sep 15, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
IHDT6AC6

Wireless Earphones

Sep 14, 2026

Equipment Class

JAB - Part 15 Class B Digital Device
IHDT6AC7

Smart Watch

Sep 11, 2026

Equipment Class

JAB - Part 15 Class B Digital Device
IHDT56AX5

Mobile Cellular Phone

Aug 28, 2026

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
IHDT56AW9

Smart Watch

May 12, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX