Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Mar 09, 2010
Application Purpose
Original Equipment
Date of Application
Mar 09, 2010
Equipment Note
FMRDS
Frequency Range
88.10000000 - 107.90000000
Company
Scosche Industries Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. (Example- use only shielded interface cables when connecting to computer or peripheral devices). This equipment complies with Part 15 of FCC RF Rules. Operation is subject to the following two conditions: 1) This device may not cause interference and 2) This device must accept any interference, including interference that may cause undesired operation of the device. Caution! The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment.

External Photos

Neutron Engineering Inc. Project No.: 1001C169 Page 2 of 5 1001C169 1001C169 Neutron Engineering Inc. Project No.: 1001C169 Page 2 of 5 1001C169 1001C169 Neutron Engineering Inc. Project No.: 1001C169 Page 3 of 5 1001C169 1001C169 Neutron Engineering Inc. Project No.: 1001C169 Page 3 of 5 1001C169 1001C169

Internal Photos

Neutron Engineering Inc. Project No.: 1001C169 Page 4 of 5 1001C169 1001C169 Neutron Engineering Inc. Project No.: 1001C169 Page 4 of 5 1001C169 1001C169 Neutron Engineering Inc. Project No.: 1001C169 Page 5 of 5 1001C169 1001C169 Neutron Engineering Inc. Project No.: 1001C169 Page 5 of 5 1001C169 1001C169

Test Report

Report No.: NEI-FCCP-1-1001C169 Page 2 of 38 Neutron Engineering Inc. Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutronshall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Report No.: NEI-FCCP-1-1001C169 Page 3 of 38 Neutron Engineering Inc. Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 10 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 3.4 DESCRIPTION OF SUPPORT UNITS 12 4 . EMC EMISSION TEST 13 4.1 CONDUCTED EMISSION MEASUREMENT 13 4.1.1 POWER LINE CONDUCTED EMISSION 13 4.1.2 MEASUREMENT INSTRUMENTS LIST 13 4.1.3 TEST PROCEDURE 14 4.1.4 DEVIATION FROM TEST STANDARD 14 4.1.5 TEST SETUP 14 4.1.6 EUT OPERATING CONDITIONS 14 4.1.7 TEST RESULTS 15 4.2 RADIATED EMISSION MEASUREMENT 17 4.2.1 RADIATED EMISSION LIMITS 17 4.2.2 MEASUREMENT INSTRUMENTS LIST 18 4.2.3 TEST PROCEDURE 18 4.2.4 DEVIATION FROM TEST STANDARD 18 4.2.5 TEST SETUP 19 4.2.6 EUT OPERATING CONDITIONS 20 4.2.7 TEST RESULTS (30~1000MHZ) 21 4.3 FIELD STRENGTH OF FUNDAMENTAL AND BAND EDGE EMISSIONS MEASUREMENT 27 4.3.1 LIMITS OF FIELD STRENGTH OF FUNDAMENTAL AND BAND EDGE EMISSIONS MEASUREMENT 27 4.3.2 MEASURING INSTRUMENTS AND SETTING 27 4.3.3 TEST PROCEDURE 27 4.3.4 TEST SETUP LAYOUT 27 4.3.5 TEST DEVIATION 27 5 . BANDWIDTH REQUIREMENT 34 5.1 LIMITS OF EMISSION BAND MEASUREMENT 34 5.1.1 MEASUREMENT INSTRUMENTS LIST 34 Report No.: NEI-FCCP-1-1001C169 Page 4 of 38 Neutron Engineering Inc. Table of Contents Page 5.1.2 TEST PROCEDURE 34 5.1.3 TEST SETUP LAYOUT 34 5.1.4 TEST DEVIATION 34 5.1.5 EUT OPERATION DURING TEST 34 5.1.6 TEST RESULT OF 20dB SPECTRUM BANDWIDTH 35 6 . EUT TEST PHOTO 37 Report No.: NEI-FCCP-1-1001C169 Page 5 of 38 Neutron Engineering Inc. 1. CERTIFICATION Equipment : FMRDS Brand Name : Scosche Model Name : FMRDS Applicant : Scosche Industries Inc. Factory : TK Developing Inc Address : 2F, building 1, An-Le Industry park, ShenZhen Date of Test : Jan. 26, 2010 ~ Feb. 10, 2010 T e s t I t e m : ENGINEERING SAMPLE Standards : FCC Part15, Subpart C (15.239)/ ANCI C63.4 : 2003 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCP-1-1001C169) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). Report No.: NEI-FCCP-1-1001C169 Page 6 of 38 Neutron Engineering Inc. 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: (Antenna to EUT distance is 3 m) FCC Part15, Subpart C Standard Test Item Limit Frequency Range (MHz) Judgment 15.207 Conducted Emission Class B 0.15 - 30 PASS 15.209 Radiated Emission Class B 30-1000 PASS 15.239 Radiated Emission 250 μV/m (48dBμV/m) @ 3m 88~108 PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Report No.: NEI-FCCP-1-1001C169 Page 7 of 38 Neutron Engineering Inc. 2.1 TEST FACILITY The test facilities used to collect the test data in this report is OS01(FCC R.N.: 95335)at the location of No.132-1, Lane 329, Sec. 2, Palian Road, Shijr City, Taipei, Taiwan. 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 A. Conducted Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE C01 ANSI150 KHz ~ 30MHz 1.94 B. Radiated Measurement : Test Site Method Measurement Frequency Range Ant. H / V U,(dB) NOTE OS-01 ANSI30MHz ~ 200MHz V 3.82 30MHz ~ 200MHz H 3.60 200MHz ~ 1,000MHz V 3.86 200MHz ~ 1,000MHz H 3.94 OS-02 ANSI30MHz ~ 200MHz V 2.48 30MHz ~ 200MHz H 2.16 200MHz ~ 1,000MHz V 2.50 200MHz ~ 1,000MHz H 2.66 Report No.: NEI-FCCP-1-1001C169 Page 8 of 38 Neutron Engineering Inc. 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Equipment FMRDS Brand Name Scosche Model Name. FMRDS OEM Brand/Model No. N/A Model Difference N/A Product Description The EUT is a. FMRDS Operation Frequency: 88.1~107.9MHz Modulation Type: FM Channel Separation: 200 KHz Antenna Designation: Printed antenna Output Power: 47.12 dBuV/m(AV Max.) Based on the application, features, or specification exhibited in User's Manual, the EUT is considered as an ITE/Computing Device. More details of EUT technical spe…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: NEI-FCCP-1-1001C169 Page 37 of 38 Neutron Engineering Inc. 6. EUT TEST PHOTO Radiated Measurement Photos PC System USB Charger Report No.: NEI-FCCP-1-1001C169 Page 37 of 38 Neutron Engineering Inc. 6. EUT TEST PHOTO Radiated Measurement Photos PC System USB Charger Report No.: NEI-FCCP-1-1001C169 Page 38 of 38 Neutron Engineering Inc. Radiated Measurement Photos Report No.: NEI-FCCP-1-1001C169 Page 38 of 38 Neutron Engineering Inc. Radiated Measurement Photos

Contact Information

Applicant

Mark Larson(SR Product Manager)
[email protected]805-486-4450Fax: 805-486-9996

Technical Contact

Neutron Engineering, Inc.Cathy Wang
[email protected]+86-769-83183000

No.132-1, Lane 329, Sec. 2. Palain Road · Taipei · Taiwan

Non-Technical Contact

Neutron Engineering, Inc.Cathy Wang
[email protected]+86-769-83183000

Test Firm

BTL Inc.Andy Yeh
[email protected]+886-2-2641-8198Fax: +886-2-2641-8698

Technical Specifications

#Rule PartsFrequency RangePower Output
115C88.1 MHz - 107.9 MHz-
Confidentiality
Long Term

Other Applications from Scosche Industries Inc

FoundIT Locator Tag - FCC ID IKQLTBTN1 - Scosche Industries Inc
IKQLTBTN1

FoundIT Locator Tag

Jul 08, 2026

Equipment Class

DTS - Digital Transmission System
FoundIT Passport - FCC ID IKQLTPAS1 - Scosche Industries Inc
IKQLTPAS1

FoundIT Passport

Jul 03, 2026

Equipment Class

DTS - Digital Transmission System
FoundIT Wallet+ - FCC ID IKQLTWAL2 - Scosche Industries Inc
IKQLTWAL2

FoundIT Wallet+

Jun 24, 2026

Equipment Class

DTS - Digital Transmission System
magicMOUNT RUGGED - FCC ID IKQMRQTR - Scosche Industries Inc
IKQMRQTR

magicMOUNT RUGGED

Apr 10, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
BT FM Car Charger - FCC ID IKQ-SBTFM5 - Scosche Industries Inc
IKQ-SBTFM5

BT FM Car Charger

Apr 09, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter