
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
These calculations are an estimate and should not be relied on as the only source of information. • If you have a pacemaker or other implantable medical device, consult your physician before you dive. Scuba diving creates physical stresses on the body, which may not be suitable for individuals with pacemakers and other implantable medical devices. •Use a wrench when installing the transmitter on your tank regulator. Do not overtighten. Do not use the transmitter housing to tighten the transmitter. • Do not grip the regulator or the transmitter to move, carry, or adjust the air tank. • Perform pre-dive safety checks, such as checking proper device function and settings, display function, battery level, tank pressure, and bubble checks to check hoses for leaks. • Confirm the dive computer is receiving a signal from the transmitter prior to starting your dive. The pressure value and battery level should appear on the dive computer screen. Each diver is responsible for their own safety and tank pressure. • Check your device regularly during a dive. If there is any apparent malfunction, terminate the dive immediately and safely return to the surface. • If the dive computer receives no signal from the transmitter, the pressure value is replaced by "NO COMMS." Check the position of the transmitter relative to the dive computer, and change the position as needed to acquire a signal. If a signal is not acquired, terminate the dive immediately and safely return to the surface. • If a tank pressure warning or battery warning appears on the dive computer, terminate the dive immediately and safely return to the surface. Disregarding the alarm may result in serious injury or death. • For safety reasons, you should never dive alone. Dive with a designated buddy. You should also stay with others for an extended time after a dive, because the potential onset of decompression illness (DCI) may be delayed or triggered by surface activities. • This device is not intended for commercial or professional dive activities. It is for recreational purposes only. Commercial or professional dive activities can expose the user to extreme depths or conditions that increase the risk of DCI. • Do not dive with a gas if you have not personally verified its contents and input the analyzed value to the device. Failure to verify tank contents and input the appropriate gas values to the device will result in incorrect dive planning information and could result in serious injury or death. •Diving with more than one gas mixture presents a much greater risk than diving with a single gas mixture. Mistakes related to the use of multiple gas mixtures may lead to serious injury or death. • After analyzing your gas, always round down the result when inputting it to the device. For example, if the analyzed gas is 31.7% oxygen, input the gas as 31%. This buffer will result in more conservative and safer calculations. • The transmitter is not an oxygen cleaned product. Do not use the transmitter with anything greater than 40% oxygen. • Diving with a partial pressure of oxygen (PO2) greater than 1.6, a central nervous system (CNS) oxygen toxicity exposure of 80% or greater, or daily oxygen tolerance units (OTU) of 300 or greater can be hazardous, and could result in serious injury or death. Terminate the dive if you reach oxygen toxicity levels. • The maximum operating pressure of the transmitter should not be exceeded. • Traveling to a higher elevation, including air travel, can temporarily cause a change in the equilibrium of dissolved nitrogen in the body. Always acclimatize to new altitudes before and after diving, because failure to do so may result in personal injury or death. Battery Warnings This device must use replaceable lithium batteries. Declaration of Conformity Hereby, Garmin declares that this product is in compliance with the Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: garmin.com/compliance. UK Declaration of Conformity Hereby, Garmin declares that this product is in compliance with the relevant statutory requirements. The full text of the declaration of conformity is available at the following internet address: garmin.com/compliance. Innovation, Science and Economic Development Canada Compliance This device contains licence-exempt transmitter(s)/ receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Radio Frequency Radiation Exposure This device is a mobile transmitter and receiver that uses an internal antenna to send and receive low levels of radio frequency (RF) energy for data communications. The device emits RF energy below the published limits when operating in its maximum output power mode and when used with Garmin authorized accessories. To comply with RF exposure compliance requirements, the device should be used as described in the manual. The device should not be used in other configurations. This device must not be co-located or operated in conjunction with any other transmitter or antenna. FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and may cause harmful interference to radio communications if not insta…
Text truncated - open the document above for the full version.
Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: August 22, 2023 SUBJECT: FCC Application for FCC ID: IPH-04770 To Whom It May Concern: Garmin International, Inc. will continue to apply processes and procedures to ensure compliance with 47 CFR 2 requirements regarding products produced under Supplier’s Declaration of Conformity procedure for class B computer peripheral portion as applicable to this composite filing. Sincerely, Michael Moranha Lead Compliance Engineer Garmin International, Inc.
Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 22, 2023 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: IPH-04770 Garmin International, Inc., (“ the applicant”) certifies that the equipment for which authorization is sought i s not “covered ” equipment prohibited from receivin g an equipment authorization pursuan t to section 2.903 of the FCC rules. Sincerely, Ben Karsak
Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 22, 2023 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: IPH-04770 Garmin International, Inc., Garmin certifies that, as of the date of the filing of the application, Garmin International, Inc. (FRN: 0005088588) is our designated U.S. agent for service of process for the above referenced FCC ID. Garmin International, Inc., accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- related proceeding involving the equipment. Garmin International, Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Garmin International, Inc. Address: 1200 East 151 st Street, Olathe, Kansas, 66062 Contact Person: Ben Karsak Tel.: 913-397-8200 Email: [email protected] Sincerely, Garmin International, Inc. Ben Karsak
Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 22, 2023 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: IPH-04770 Garmin International, Inc., (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as an specifically named entity or any of its subsidiaries or affiliates) as an producing “covered” equipment. Sincerely, Ben Karsak
June 21, 2023 Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Innovation, Science and Economic Development Canada Certification and Engineering Bureau 3701 Carling Avenue PO Box 11490, Station H Ottawa, Ontario, Canada K2H 8S2 To Whom It May Concern: Pursuant to 47 CFR 2.911, Garmin International, Inc. (Garmin) has authorized the following Garmin International Associates to act on Garmin's behalf for the sole and express purpose of processing applications to the Federal Communication Commission (FCC) and Innovation, Science and Economic Development Canada (ISED) for equipment authorization or certification. Mr. Chris Strauss, Compliance Engineering Team Lead Mr. William Pertner, Compliance Engineering Team Lead Mr. Jay Everett, Compliance Engineering Team Lead Mr. Mike Moranha, Compliance Engineer Ms. Poojita Bhattu, Compliance Engineer Mr. Jeffrey Hailey, Compliance Engineer Mr. Dan Irish, Compliance Engineer Mr. Kiran Kumar, Compliance Engineer Mr. Tim Olson, Compliance Engineer Mr. Carlos Ortega, Compliance Engineer Mr. David Utt, Staff Compliance Engineer Mr. Jonathan Shafer, Design Certification Engineer Ms. Sara Jones, Design Certification Engineer Mr. Jacky Yeung, Compliance Engineer As such, the Garmin Associates listed above are authorized to: 1) sign Form 731, 2) sign letters of application, 3) request confidentiality, and 4) exchange data and information with the FCC, IC and/or authorized TCBs on behalf of Garmin. In addition, these individuals shall be considered "authorized individuals" to act on Garmin's behalf where an "authorized individual's" attestation is necessary or preferred. This authorization remains in effect until notified to the contrary by Garmin. Sincerely, Ben Karsak Manager Compliance Engineering Garmin International, Inc.
REQUEST FOR CONFIDENTIALITY Date: 22 August 2023 Applicant: Garmin Interna�onal Subject: Confiden�ality Request for FCC ID: IPH-04770 IC: 1792A-04770 Pursuant to FCC 47 CFR 0.457(d) and 0.459, and IC RSP-100 Sec�on 12.4, we request that a part of the FCC and ISED applica�on be held confiden�al. Type Of Confiden�ality Requested Exhibit ☐ Short Term ☒ Permanent ☐ Not Provided Block Diagrams ☐ Short Term ☒ Permanent ☐ Not Provided Schema�cs ☐ Short Term ☒ Permanent ☐ Not Provided Opera�onal Descrip�on/ Theory of Opera�on ☐ Short Term ☐ Permanent ☒ Not Provided Parts List & Placement/BOM ☐ Short Term ☒ Permanent ☐ Not Provided Tune-Up Procedure ☒ Short Term ☐ Permanent ☐ Not Provided Test Setup Photos ☒ Short Term ☐ Permanent ☐ Not Provided User’s Manual(s) ☒ Short Term ☐ Permanent ☐ Not Provided External Photos ☒ Short Term ☐ Permanent ☐ Not Provided Internal Photos Garmin Interna�onal has spent a substan�al effort in developing this product and it is one of the first of its kind in the industry . Having the subject informa�on easily available to "compe��on" would negate the advantage we have achieved by developing this product. Not protec�ng the details of the design will result in financial hardship. Permanent Confiden�ality: Garmin requests the exhibits listed above as permanently confiden�al be permanently withheld from public review due to materials that contain trade secrets and proprietary informa�on not customarily released to the public. Short-Term Confiden�ality (if applicable): The applicant requests the exhibits selected above as short term confiden�al be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authoriza�on and prior to marke�ng. This is to avoid premature release of sensi�ve informa�on prior to marke�ng or release of the product to the public. Sincerely, Mike Moranha Compliance Engineer
External Photos - A04770 Front Right Back Le� To p Botom
Product Label Drawing and Placement Side of the housing product Side of the housing Top Housing Location of label
Internal Photos - A04770
Test Report 2023-053 Version B Issued 12 Sep 2023 Project GCL-0315 Model Identifier A04770 Primary Test Standard 47CFR 1.1310 47CFR 2.1093 RSS-102 Issue 5 Amd. 1 Garmin Compliance Lab Garmin International 1200 E 151 st Street Olathe Kansas 66062 USA Client-supplied Information FCC ID: IPH-04770 IC ID: 1792A-04770 See section 6 of this report regarding the presence or absence of accreditation logos or marks on this cover page. Page 2 of 13 GCL Test Report 2023-053 Version B This report may be reproduced in whole. Reproduction of parts or excerpts requires lab management approval. Garmin 1. Summary The equipment or product described in section 5 of this report was tested at the Garmin Compliance Lab according to standards listed in section 6. This report focuses on the 2.4 GHz transceiver(s). The results are as follows. Parameter Description Key Performance Values [Performance Class] Result Data starts at page Transmit Power The average transmit power presented to the antenna is used to determine the undesired biological effects the test sample could evoke. This data has no Pass or Fail values under this standard, but is used in subsequent analyses. Measured 9 Exemption from routine evaluation Radio emissions at the separation distance are sufficiently low to exempt the radio from a detailed evaluation. The tuned time-averaged EIRP power was below the exemption limit in each case analyzed. Exempt 11 Exposure Reference Level (MPE) Radio emissions at the separation distance are below the exposure reference level where health effects could be a concern. N/A N/A N/A NT (Not Tested) means the requirement may or may not be applicable, but the relevant measurement or test was not performed as part of this test project. N/A (Not Applicable) means the lab judged that the test sample is exempt from the requirement. Table 1: Summary of results Report Organization For convenience of the reader, this report is organized as follows: 1. Summary 2. Test Background 3. Report History and Approval 4. Test Sample Modifications and Special Conditions 5. Description of Equipment Tested 6. Test Standards Applied 7. Measurement Instrumentation Uncertainty 8. Selected Examples of Calculations 9. Environmental Conditions During Test 10. Immunity Performance Criteria Annex: Test records are provided for each type of test, following the order and page numbering stated in the summary table. Concluding notes appear on the final page of this report. Page 3 of 13 GCL Test Report 2023-053 Version B This report may be reproduced in whole. Reproduction of parts or excerpts requires lab management approval. Garmin 2. Test Background The testing reported here was performed at the Garmin Compliance Lab, an organization within Garmin International, located at 1200 E 151 st St, Olathe Kansas, USA. The contact telephone number is +1.913.397.8200. The testing was performed on behalf of the Garmin design group, a separate organization located at 1200 E 151 st St, Olathe Kansas, USA. Witnesses from the business group included: None. Test Sample received: 22 Jun 2023 Test Start Date: 23 Jul 2023 Test End Date: 03 Aug 2023 The data in this test report apply only to the specific samples tested. Upon receipt all test samples were believed to be properly assembled and ready for testing. 3. Report History and Approval This report was written by Majid Farah and initially issued on 29 Aug 2023 as Version A. Version B issued on 12 Sep 2023 Report Technical Review: _________________________________________ David Arnett Technical Lead EMC Engineer Report Approval: _________________________________________ Shruti Kohli Manager Test and Measurement (EMC, Reliability and Calibration) 4. Test Sample Modifications and Special Conditions The following special conditions or usage attributes were judged during test to be necessary to achieve compliance with one or more of the standards listed in section 6 of this report: None The following modifications to the test sample(s) were made, and are judged necessary to achieve compliance with one or more of the standards listed in section 6 of this report: None Page 4 of 13 GCL Test Report 2023-053 Version B This report may be reproduced in whole. Reproduction of parts or excerpts requires lab management approval. Garmin 5. Description of the Equipment Tested 5.1 Unique Identification Product Model A04770 Serial Numbers Tested 817000237 This product tested is a transceiver for multiple types of diving purposes. The client affirmed that the test samples will be representative of production in all relevant aspects. 5.2 Key Parameters EUT Input Power: Battery operated 3 Vdc I/O Ports: None Radio Transceivers: Bluetooth Low Energy, ANT Radio Receivers: None Primary Functions: Sharing data between different devices Typical use location: Body worn Highest internal frequency: 2.484 GHz Firmware Revision V0.98 5.3 Operating modes During test, the EUT was operated in one or more of the following modes. Mode 1: M1 (ANT Tx). EUT in test mode and ANT Tx always On. Mode 2: M2 (ANT Lnk). EUT linked to companion device through ANT. Mode 3: M3 (BLE Tx). EUT in test mode and BLE Tx always On. Mode 4: M4 (BLE Lnk). EUT linked to companion device through BLE. Mode 5: M5 (All Tx off). EUT in test mode and all transmitters turned off. Mode 6: M6 (All Tx on). EUT in test mode and all transmitters are always On. Mode 7: M7 (All Rx on). EUT in test mode and in receiver mode only. 5.4 EUT Arrangement During test, the EUT components and associated support equipment were selected including the following arrangement sets. Arrangement 1: A1 (Standalone) EUT powered up through internal battery Arrangement 2: A2 (PwrSupply) EUT powered up through an adjustable DC power supply 5.5 Associated Equipment (AE) used Description Manufacturer Model Serial Number USB ANT stick Garmin 010-01058-00 R203-JN6016 Table 2: List of associated equipment that may have been used during test 5.6 Cables used Description From To Length EMC Treatment Battery i…
Text truncated - open the document above for the full version.
Test Report 2023-039 Version A Issued 23 Aug 2023 Project GCL-0315 Model Identifier A04770 Primary Test Standard FCC Part 15.247 RSS-247 Issue 2 Amd 1 Garmin Compliance Lab Garmin International 1200 E 151 st Street Olathe Kansas 66062 USA Client-supplied Information FCC ID: IPH-04770 IC ID: 1792A-04770 See section 6 of this report regarding the presence or absence of accreditation logos or marks on this cover page. Page 2 of 33 GCL Test Report 2023-039 Version A This report may be reproduced in whole. Reproduction of parts or excerpts requires lab management approval. Garmin 1. Summary The equipment or product described in section 5 of this report was tested at the Garmin Compliance Lab according to standards listed in section 6. This report focuses on the 2.4 GHz transceiver(s). The results are as follows. Parameter Description Key Performance Values Result Data starts at page Hopping Channels The radio manages it use of channels appropriately. [15.247(a)(1); RSS-247 at 5.1] N/A. The radios described in this report are not subjected to the Frequency Hopping rules. N/A N/A DTS Bandwidth The nature of the radio signal is broadband, being at least 500 kHz wide. [15.247(a)(2); RSS-247 at 5.2(a)] The 6dB bandwidth is 694.1 kHz or greater. PASS 10 Other Bandwidths Regulatory agencies also require the reporting of signal bandwidths using alternate processes. [2.202; RSS-GEN at 6.7] These values are reported but have no actual performance requirements. Reported 13 Transmit Power The peak transmit power presented to the antenna is no greater that 1 Watt or 30 dBm. The effective radiated power is limited to 4 Watts or 36 dBm EIRP. [15.247(b); RSS-247 at 5.4(d)] The maximum transmit power is 5.7 dBm. PASS 16 Antenna Gain The radio should not focus too much energy in any direction. Unless additional rules are applied, the antenna gain is no greater than 6 dBi. [15.247(b)(4) and (c)] NT. The client stated that the maximum antenna gain was -0.3 dBi and will document antenna gain separately. NT NT Unwanted Emissions (Conducted Spurious) The radio should not provide too much radio energy to the antenna at frequencies beyond its intended frequency band. [15.247(d); RSS-247 at 5.5] Emissions outside the band must be reduced at least 20 dB from in-band levels. The measured reduction was at least 36.30 dB. PASS 18 Restricted Bands The radio must not emit in certain designated restricted frequency bands above a set of limit values. [15.247(d) and 15.205; RSS- 247 at 3.3] Emissions in the restricted bands were at least 8.417 dB below the applicable limits. PASS 22 Power Spectral Density The radio must not focus too much radio energy in a narrow frequency band. [15.247(e); RSS-247 at 5.2(b)] The limit is 8 dBm in a 3 kHz band. The strongest emission level was -11.16 dBm in a band of at least 3 kHz. PASS 26 Page 3 of 33 GCL Test Report 2023-039 Version A This report may be reproduced in whole. Reproduction of parts or excerpts requires lab management approval. Garmin Hybrid Systems A radio that is both frequency hopping and digitally modulated should satisfy a combination of system rules. [15.247(f); RSS-247 at 5.3] N/A. The radios described in this report are not subjected to the Hybrid System rules. N/A N/A Frequency Hopping Rules Frequency hopping systems have additional functional requirements. [15.247(g) and (h); RSS-247 at 5.1] N/A. The radios described in this report are not subjected to the Frequency Hopping rules. N/A N/A Radio Safety The radio emissions must meet public health & safety guidelines related to human exposure. [15.247(i) and 1.1307; RSS- Gen at 3.4] NT. Client will report radio energy safety results separately. NT NT Frequency Stability The radio tuning must be robust over a range of temperature and supply voltage conditions. [RSS-Gen at 6.11] Radio emissions remained within the allowed radio band under all environmental conditions tested. PASS 28 NT (Not Tested) means the requirement may or may not be applicable, but the relevant measurement or test was not performed as part of this test project. N/A (Not Applicable) means the lab judged that the test sample is exempt from the requirement. Table 1: Summary of results Report Organization For convenience of the reader, this report is organized as follows: 1. Summary 2. Test Background 3. Report History and Approval 4. Test Sample Modifications and Special Conditions 5. Description of Equipment Tested 6. Test Standards Applied 7. Measurement Instrumentation Uncertainty 8. Selected Examples of Calculations 9. Environmental Conditions During Test 10. Immunity Performance Criteria Annex: Test records are provided for each type of test, following the order and page numbering stated in the summary table. Concluding notes appear on the final page of this report. Due to confidentiality, certain material (such as test setup photographs) has been removed from this report and placed in GCL Test Report 2023-041. That report is treated as a part of this document by way of this reference. Page 4 of 33 GCL Test Report 2023-039 Version A This report may be reproduced in whole. Reproduction of parts or excerpts requires lab management approval. Garmin 2. Test Background The testing reported here was performed at the Garmin Compliance Lab, an organization within Garmin International, located at 1200 E 151 st St, Olathe Kansas, USA. The contact telephone number is +1.913.397.8200. The testing was performed on behalf of the Garmin design group, a separate organization located at 1200 E 151 st St, Olathe Kansas, USA. Witnesses from the business group included: None. Test Sample received: 22 Jun 2023 Test Start Date: 23 Jul 2023 Test End Date: 03 Aug 2023 The data in this test report apply only to the specific samples tested. Upon receipt all test samples were believed to be properly assembled and ready for testing. 3. Report History and Approval This report was written by Majid Farah and initially issued on 23 Aug 2023 as Version A. Report Technical Review: _…
Text truncated - open the document above for the full version.
File Name: Polarization ThetaFrequency (MHz) 2350Theta Angle (∞)015 Phi Angle (∞)Response (dB)Phi Angle (∞)Response (dB)Phi Angle (∞) 0-14.140-15.150 15-25.4860-8.0530 30-20.58120-4.9960 45-12.62180-11.9290 60-8.91240-11.28120 75-6.78300-4.68150 90-5.56360-15.15180 105-5.04210 120-5.12240 135-5.82270 150-7.26300 165-9.73330 180-14.14360 195-25.48 210-20.58 225-12.62 240-8.91 255-6.78 270-5.56 285-5.04 300-5.12 315-5.82 330-7.26 345-9.73 355-12.34 360-14.14 2360Theta Angle (∞)015 Phi Angle (∞)Response (dB)Phi Angle (∞)Response (dB)Phi Angle (∞) 0-13.820-15.140 15-25.0560-7.6730 30-20.37120-4.5760 45-12.36180-11.4690 60-8.64240-11.13120 75-6.5300-4.41150 90-5.28360-15.14180 105-4.75210 120-4.83240 135-5.53270 150-6.96300 165-9.43330 180-13.82360 195-25.05 210-20.37 225-12.36 240-8.64 255-6.5 270-5.28 285-4.75 300-4.83 315-5.53 330-6.96 345-9.43 355-12.02 360-13.82 2370Theta Angle (∞)015 Phi Angle (∞)Response (dB)Phi Angle (∞)Response (dB)Phi Angle (∞) 0-13.760-15.370 15-24.6360-7.8130 30-20.75120-4.6660 45-12.55180-11.4790 60-8.78240-11.37120 75-6.61300-4.64150 90-5.37360-15.37180 105-4.83210 120-4.9240 135-5.58270 150-7300 165-9.43330 180-13.76360 195-24.63 210-20.75 225-12.55 240-8.78 255-6.61 270-5.37 285-4.83 300-4.9 315-5.58 330-7 345-9.43 355-12 360-13.76 2380Theta Angle (∞)015 Phi Angle (∞)Response (dB)Phi Angle (∞)Response (dB)Phi Angle (∞) 0-13.040-14.860 15-23.6260-7.3330 30-20.4120-4.1260 45-12.03180-10.9790 60-8.22240-10.83120 75-6.03300-4.21150 90-4.78360-14.86180 105-4.23210 120-4.28240 135-4.95270 150-6.35300 165-8.77330 180-13.04360 195-23.62 210-20.4 225-12.03 240-8.22 255-6.03 270-4.78 285-4.23 300-4.28 315-4.95 330-6.35 345-8.77 355-11.3 360-13.04 2390Theta Angle (∞)015 Phi Angle (∞)Response (dB)Phi Angle (∞)Response (dB)Phi Angle (∞) 0-12.70-14.560 15-23.6360-6.9630 30-19.61120-3.7460 45-11.44180-10.790 60-7.68240-10.25120 75-5.52300-3.95150 90-4.28360-14.56180 105-3.74210 120-3.81240 135-4.5270 150-5.92300 165-8.36330 180-12.7360 195-23.63 210-19.61 225-11.44 240-7.68 255-5.52 270-4.28 285-3.74 300-3.81 315-4.5 330-5.92 345-8.36 355-10.93 360-12.7 2400Theta Angle (∞)015 Phi Angle (∞)Response (dB)Phi Angle (∞)Response (dB)Phi Angle (∞) 0-12.520-14.440 15-24.1560-6.4830 30-18.65120-3.3260 45-10.83180-10.4590 60-7.15240-9.56120 75-5.03300-3.64150 90-3.83360-14.44180 105-3.32210 120-3.41240 135-4.12270 150-5.57300 165-8.07330 180-12.52360 195-24.15 210-18.65 225-10.83 240-7.15 255-5.03 270-3.83 285-3.32 300-3.41 315-4.12 330-5.57 345-8.07 355-10.7 360-12.52 2410Theta Angle (∞)015 Phi Angle (∞)Response (dB)Phi Angle (∞)Response (dB)Phi Angle (∞) 0-12.650-14.610 15-25.2460-6.0730 30-17.89120-3.0360 45-10.43180-10.3390 60-6.86240-9.02120 75-4.79300-3.44150 90-3.62360-14.61180 105-3.14210 120-3.26240 135-4270 150-5.49300 165-8.05330 180-12.65360 195-25.24 210-17.89 225-10.43 240-6.86 255-4.79 270-3.62 285-3.14 300-3.26 315-4 330-5.49 345-8.05 355-10.76 360-12.65 2420Theta Angle (∞)015 Phi Angle (∞)Response (dB)Phi Angle (∞)Response (dB)Phi Angle (∞) 0-12.970-15.060 15-26.3460-5.7930 30-17.62120-2.9160 45-10.4180-10.2990 60-6.89240-8.77120 75-4.86300-3.39150 90-3.72360-15.06180 105-3.25210 120-3.39240 135-4.16270 150-5.67300 165-8.28330 180-12.97360 195-26.34 210-17.62 225-10.4 240-6.89 255-4.86 270-3.72 285-3.25 300-3.39 315-4.16 330-5.67 345-8.28 355-11.04 360-12.97 2430Theta Angle (∞)015 Phi Angle (∞)Response (dB)Phi Angle (∞)Response (dB)Phi Angle (∞) 0-13.350-15.750 15-27.2760-5.6830 30-17.64120-2.9560 45-10.55180-10.3190 60-7.08240-8.73120 75-5.07300-3.46150 90-3.95360-15.75180 105-3.49210 120-3.64240 135-4.42270 150-5.96300 165-8.59330 180-13.35360 195-27.27 210-17.64 225-10.55 240-7.08 255-5.07 270-3.95 285-3.49 300-3.64 315-4.42 330-5.96 345-8.59 355-11.39 360-13.35 2440Theta Angle (∞)015 Phi Angle (∞)Response (dB)Phi Angle (∞)Response (dB)Phi Angle (∞) 0-13.850-16.70 15-28.0760-5.8830 30-17.94120-3.2860 45-10.92180-10.5890 60-7.48240-8.97120 75-5.48300-3.81150 90-4.36360-16.7180 105-3.92210 120-4.07240 135-4.86270 150-6.4300 165-9.05330 180-13.85360 195-28.07 210-17.94 225-10.92 240-7.48 255-5.48 270-4.36 285-3.92 300-4.07 315-4.86 330-6.4 345-9.05 355-11.87 360-13.85 2450Theta Angle (∞)015 Phi Angle (∞)Response (dB)Phi Angle (∞)Response (dB)Phi Angle (∞) 0-14.390-17.850 15-29.0360-6.2530 30-18.24120-3.7360 45-11.31180-10.9490 60-7.89240-9.3120 75-5.91300-4.26150 90-4.8360-17.85180 105-4.36210 120-4.53240 135-5.32270 150-6.88300 165-9.54330 180-14.39360 195-29.03 210-18.24 225-11.31 240-7.89 255-5.91 270-4.8 285-4.36 300-4.53 315-5.32 330-6.88 345-9.54 355-12.39 360-14.39 2460Theta Angle (∞)015 Phi Angle (∞)Response (dB)Phi Angle (∞)Response (dB)Phi Angle (∞) 0-14.80-19.040 15-30.2260-6.5430 30-18.24120-4.0860 45-11.46180-11.2190 60-8.09240-9.53120 75-6.13300-4.63150 90-5.03360-19.04180 105-4.61210 120-4.79240 135-5.6270 150-7.18300 165-9.87330 180-14.8360 195-30.22 210-18.24 225-11.46 240-8.09 255-6.13 270-5.03 285-4.61 300-4.79 315-5.6 330-7.18 345-9.87 355-12.76 360-14.8 2470Theta Angle (∞)015 Phi Angle (∞)Response (dB)Phi Angle (∞)Response (dB)Phi Angle (∞) 0-14.810-19.760 15-30.0860-6.5630 30-18.33120-4.1160 45-11.52180-11.1390 60-8.14240-9.55120 75-6.17300-4.72150 90-5.08360-19.76180 105-4.65210 120-4.83240 135-5.64270 150-7.21300 165-9.9330 180-14.81360 195-30.08 210-18.33 225-11.52 240-8.14 255-6.17 270-5.08 285-4.65 300-4.83 315-5.64 330-7.21 345-9.9 355…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.70 mW |
Portable Digital Transceiver
Equipment Class
NII - Unlicensed National Information Infrastructure TXPortable Digital Transceiver
Equipment Class
NII - Unlicensed National Information Infrastructure TXMobile Digital Transceiver
Equipment Class
DTS - Digital Transmission SystemMarine Stereo
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterMarine Stereo
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter