FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Garmin International Inc/
  3. IPH-04853

IPH-04853Digital Transmission System Transceiver

Garmin International Inc

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Aug 12, 2024
Application Purpose
Original Equipment
Date of Application
Jul 21, 2024
Equipment Note
Digital Transmission System Transceiver
Frequency Range
5745.00000000 - 5825.00000000
Company
Garmin International Inc
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev 1/ 26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: April 25, 2024 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: IPH-04853 FRN: 0005088588 Garmin International, Inc., (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” eq uipment prohibited fr om receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Ben Karsak

Attestation Statements

Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: April 25, 2024 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: IPH-04853 Garmin International, Inc., Garmin certifies that, as of the date of t he filing o f the application, Garmin International, I nc.. is our designated U.S. agent for service of process for the above referenced FCC ID. Garmin International, Inc., accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or t he conclusion of any Commission-related proceeding involving the equipment. Garmin International, Inc. accepts, as of the date of t he filing of the application, the obligation of the designated U.S. agent for service of process for t he above referenced FCC ID. Designated U.S. Agent Information: FRN: 0005088588 Name: Garmin International, Inc. Address: 1200 East 151 st Street, O lathe, Kansas, 6 6062 Contact Person: Ben Karsak Tel.: 913-397-1946 Email: [email protected] Sincerely, Garmin International, Inc. Ben Karsak

Attestation Statements

Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: April 25, 2024 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: IPH-04853 FRN: 0005088588 Garmin International, Inc., (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered Li st (as a specifically named entity or any of i ts subsidiaries or affiliates) as an entity producing “covered” equipment. S incerely, Ben Karsak

Cover Letter(s)

March 6, 2024 Federal Communications Commission Equip Approval Services Post Office Box 358315 Pittsburgh, Pennsylvania 15215-5315 To Whom It May Concern: Pursuant to 47 CFR 2.911, Garmin International, Inc. (Garmin) has authorized Mr. Patrick Powell and Mr. Jeremy Cott of The Compatibility Center LLC to act on Garmin’s behalf for the sole and express purpose of processing applications to the Federal Communication Commission (FCC) for equipment FCC authorization. As such Mr. Powell and Mr. Cott are authorized to: 1) Sign Form 731, 2) Sign letters of application, 3) Request confidentiality, and 4) Exchange data and information with the FCC, and authorized TCBs on behalf of Garmin. This authorization is not assignable to other beyond Mr. Powell and Mr. Cott. This authorization is in effect until notified to the contrary by Garmin. Sincerely, Ben Karsak Manager Compliance Engineering

Cover Letter(s)

March 28, 2024 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Innovation, Science and Economic Development Canada Certification and Engineering Bureau 3701 Carling Avenue PO Box 11490, Station H Ottawa, Ontario, Canada K2H 8S2 To Whom It May Concern: Pursuant to 47 CFR 2.911, Garmin International, Inc. (Garmin) has authorized the following Garmin International Associates to act on Garmin's behalf for the sole and express purpose of processing applications to the Federal Communication Commission (FCC) and Innovation, Science and Economic Development Canada (ISED) for equipment authorization or certification. Mr. William Pertner, Compliance Engineering Team Lead Mr. Jay Everett, Compliance Engineering Team Lead Mr. Richard Kockelkoren, Compliance Engineer Mr. Mike Moranha, Compliance Engineer Ms. Poojita Bhattu, Compliance Engineer Mr. Jeffrey Hailey, Compliance Engineer Mr. Dan Irish, Compliance Engineer Mr. Kiran Kumar, Compliance Engineer Mr. Tim Olson, Compliance Engineer Mr. David Utt, Staff Compliance Engineer Mr. Jonathan Shafer, Design Certification Engineer Ms. Sara Jones, Design Certification Engineer Mr. Jacky Yeung, Compliance Engineer As such, the Garmin Associates listed above are authorized to: 1) sign Form 731, 2) sign letters of application, 3) request confidentiality, and 4) exchange data and information with the FCC, IC and/or authorized TCBs on behalf of Garmin. In addition, these individuals shall be considered "authorized individuals" to act on Garmin's behalf where an "authorized individual's" attestation is necessary or preferred. This authorization remains in effect until notified to the contrary by Garmin. Sincerely, Ben Karsak Manager Compliance Engineering Garmin International, Inc.

Cover Letter(s)

File: A04853 Submittal letter Page 1 of 1 June 5, 2024 Timco Engineering Inc. 13146 NW 86th DR. Suite 400 Alachua, FL 32615 Applicant: Garmin International, Inc. 1200 East 151st Street Olathe, KS 66062 CORES number: 0005088588 Equipment: FCC ID: IPH-04853 FCC Rules: Parts 2, 15C To Whom It May Concern: The form 731 and application have been electronically submitted and any attachments will be uploaded to your web site for use in obtaining a grant of certification. Confidentiality is requested as outlined below. Permanent Garmin International, Inc. requests that the material in the Block Diagram, Operational Descriptions, and Schematics be withheld from public disclosure pursuant to Sections 0.457 and 0.459 of the Commission’s Rules following grant of the application. A statement of confidentiality will be attached with the application at the time of submittal. CONFIDENTIAL FILES A04853 Block Diagram.pdf A04853 Bluetooth and WiFi Theory of Operation.pdf A04853 Conf Opdes KDB 594280.pdf A04853 Schematic (confidential).pdf Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Best Regards, Patrick Powell Rogers Labs, a division of The Compatibility Center LLC Enclosures Rogers Labs, a division of The Compatibility Center LLC 7915 Nieman Rd. Lenexa, KS 66214 Phone / Fax (913) 660-0666

Cover Letter(s)

June 19, 2024 Timco Engineering Inc. 13146 NW 86th DR. Suite 400 Alachua, FL 32615 Applicant: Garmin International, Inc. 1200 East 151st Street Olathe, KS 66062 Re: Short-term Confidentiality request for submittal information regarding FCC ID: IPH-04853 FCC Rules: Parts 2 and 15C Dear Sirs: Garmin International, Inc. requests that the following information be withheld from public disclosure pursuant to CFR47 paragraphs 0.457 and 0.459, and KDB 726920 for 180 Days. Disclosure of information would offer competitors additional unwarranted insight into the state of the product development. Short-term confidential files File A04853 Short Term Conf ExtPho.pdf A04853 Short Term Conf IntPho.pdf A04853 Short Term Conf TSup.pdf A04853 OM.pdf A04853 OM1.pdf A04853 OM2.pdf Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Best Regards, Patrick Powell Rogers Labs, a division of The Compatibility Center LLC Rogers Labs, a division of The Compatibility Center LLC 7915 Nieman Rd. Lenexa, KS 66214 Phone / Fax (913) 660-0666

Cover Letter(s)

Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: May 28, 2 024 SUBJECT: FCC Application for FCC ID: IPH-04853 To Whom It May Concern: Garmin will continue to ap ply processes and procedures t o ensure compliance with 47 CFR 2 requirements regarding products produced under Supplier’s Declaration of Conformity procedure for class B computer peripheral portion as applicable to this composite filing. Sincerely, Tim Olson Senior Compliance Engine er

Cover Letter(s)

File: A04853 Confidential Request Letter Page 1 of 2 June 5, 2024 Timco Engineering Inc. 13146 NW 86th DR. Suite 400 Alachua, FL 32615 Applicant: Garmin International, Inc. 1200 East 151st Street Olathe, KS 66062 Re: Confidentiality for submittal information regarding FCC ID: IPH-04853 Product: Transmitter operated under 47CFR Section 15C Dear Sirs: Garmin International, Inc. requests that the material in the Block Diagram, Operational Description, and Schematic be withheld from public disclosure pursuant to Sections 0.457 and 0.459 of the Commission’s Rules following grant of the application. In support of this request, Garmin International, Inc. submits the following information. CONFIDENTIAL FILES A04853 Block Diagram.pdf A04853 Bluetooth and WiFi Theory of Operation.pdf A04853 Conf Opdes KDB 594280.pdf A04853 Schematic (confidential).pdf 1. Identification of the specific information for which confidential treatment is sought: The materials set forth in the Block Diagram, Operational Description, and Schematic which are segregated, from the non-confidential exhibits of the application, are those for which confidentiality is sought. 2. Identification of the Commission proceeding in which the information was submitted or a description of the circumstances giving rise to the submission: The proceeding is that involving the application for equipment authorization (certification) under FCC ID: IPH-04853 3. Explanation of the degree to which the information is commercial or financial, or contains a trade secret or is privileged: This material includes a detailed Block Diagram, Operational Description, and Schematic. As such, this material is treated as highly confidential business information. Rogers Labs, a division of The Compatibility Center LLC 7915 Nieman Rd. Lenexa, KS 66214 Phone / Fax (913) 660-0666 File: A04853 Confidential Request Letter Page 2 of 2 4. Explanation of the degree to which the information concerns a service that is subject to competition: The material for which confidentiality is sought is employed in the design and manufacture of this transmitting equipment that is offered on a highly competitive basis. Customers for this equipment have a variety of competing sources. 5. Explanation of how disclosure of the information could result in substantial competitive harm: Disclosure would, in effect, give away the fruits of the labors of Garmin International, Inc.’s engineering personnel, who have designed the equipment and the manufacturing process. Disclosure would also offer competitors additional unwarranted insight into the state of the product development, thereby allowing competitors an advantage, not available to Garmin International, Inc. 6. Identification of any measures taken by the submitting party to prevent unauthorized disclosure: The information for which confidential treatment is sought is kept confidential by Garmin International, Inc. and not made available to third parties except pursuant to non-disclosure agreements. 7. Identification of whether the information is available to the public and the extent of any previous disclosure of the information to third parties: To the knowledge of those preparing this application, the information has not been disclosed publicly heretofore. While the general theory of operation of this equipment has been the subject of numerous disclosures in industry the protection sought is narrowly drawn as provided in regulations. 8. Justification of the period during which the submitting party asserts that the material should not be available for public disclosure: This material should not be disclosed for at least 25 years. While improvements in design are made relatively frequently, disclosure of the design information would lead to insights into both design and manufacturing techniques that could have an adverse competitive effect for many years to come. As such, it is important that the design not be made available to unauthorized persons who might attempt to use knowledge of the design to compromise the applications for which the equipment will be employed. Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Best Regards, Patrick Powell Rogers Labs, a division of The Compatibility Center LLC

ID Label/Location Info

E-Label Information A.The following specific instructions are provided in the Quick Start Manual that ships with the device a.Label viewing directions are found in the user manual (outlined here for reference) and available on line at www.garmin.com b.Getting the Owner's Manual i.The owner's manual includes instructions for using device features and accessing regulatory information Go to www.garmin.com/manuals/A04853 B.The following are the specific instructions provided in the owner’s manual that is provided at www.garmin.com/manuals: a.Device Information b.Viewing Regulatory and Compliance information. 1) From the settings menu, swipe to the bottom of the menu. 2) Select Device > Regulatory M/N: A04853 FCC ID: IPH-04853 IC: 1792A-04853 C.The above information is programmed by Garmin in such a manner that third-parties cannot modify it. a.“No special accessories or supplemental plug-ins (e.g., installation of a SIM/USIM card) are required to access the information. Access to the information is provided without special codes, accessories, or permissions beyond the normal security protection to unlock the screen, sign-in page, or overall product access.” D.The above M/N, FCC ID, and IC numbers can be found printed on the product packaging

RF Exposure Info

45461970 R1.0 Test Report Issue Date: 6 June 2024 ©2024 Celltech Labs Inc. This document is not to be reproduced in whole or in part without the expressed written permission of Celltech Labs Inc. Page 59 of 61 APPENDIX E – PROBE CALIBRATION 45461970 R1.0 Test Report Issue Date: 6 June 2024 ©2024 Celltech Labs Inc. This document is not to be reproduced in whole or in part without the expressed written permission of Celltech Labs Inc. Page 60 of 61 APPENDIX F – DIPOLE CALIBRATION NCL CALIBRATION LABORATORIES Calibration File No: DC-1904 Project Number: 5921 Client.: Celltech Address: 21 – 364 Lougheed Road, Kelowna, BC V1X 7R8, Canada C E R T I F I C A T E OF C A L I B R A T I O N It is certified that the equipment identified below has been calibrated in the NCL CALIBRATION LABORATORIES by qualified personnel following recognized procedures and using transfer standards traceable to NRC/NIST. Validation Dipole (Head) Manufacturer: SPEAG Part number: D2450V2 Frequency: 2450 MHz Serial No: 825 Calibrated: 27/04/2021 Released on: 05/05/2021 This Calibration Certificate is incomplete unless accompanied by the Calibration Results Summary NCL Calibration Laboratories Division of APREL Laboratories DC-1904 Dipole SN: 825 Page 2 of 7 This page has been reviewed for content and attested to on Page 2 of this document. Conditions Dipole SN 825 was a re-calibration. Ambient Temperature of the Laboratory: 21 C +/- 0.5C Temperature of the Tissue: 21 C +/- 0.5C Primary Measurement Standards Instrument Serial Number Cal due date Signal Generator HP 83640B 3844A00689 Sept. 17, 2022 Network Analyzer Keysight E5063A MY54502902 Mar. 9, 2023 Spectrum Analyzer Keysight N9030B MY57140772 Apr. 20, 2023 Attestation The below named signatories have conducted the calibration and review of the data which is presented in this calibration report. NCL Calibration Laboratories Division of APREL Laboratories DC-1904 Dipole SN: 825 Page 3 of 7 This page has been reviewed for content and attested to on Page 2 of this document. Calibration Results Summary The following results relate the Calibrated Dipole and should be used as a quick reference for the user. Tissue Validation Tissue Frequency Dielectric constant,  r Conductivity,  [S/m] Head 2450 MHz 40.73 1.86 Electrical Specification Tissue Frequency Return LossImpedanceSWR: Head 2450 MHz -19.83 dB 43.26  1.23U System Validation Results Tissue Frequency 1-Gram SAR 10-Gram SAR Uncertainty Head 2450 MHz 52.719 W/kg 24.015 W/kg 19.8% Head NCL Calibration Laboratories Division of APREL Laboratories DC-1904 Dipole SN: 825 Page 4 of 7 This page has been reviewed for content and attested to on Page 2 of this document. Introduction This Calibration Report has been produced in line with the SSI Dipole Calibration Procedure SSI-TP-018-ALSAS. The results contained within this report are for Validation Dipole SN 825. The calibration routine consisted of a three-step process. Step 1 was a mechanical verification of the dipole to ensure that it meets the mechanical specifications. Step 2 was an Electrical Calibration for the Validation Dipole, where the SWR, Impedance, and the Return loss were assessed. Step 3 involved a System Validation using the ALSAS-10U, along with APREL E-020 30 MHz to 6 GHz E-Field Probe Serial Number 225. References o IEEE Standard 1528:2013 IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques o EN 62209-1:2016 Human Exposure to RF Fields from hand-held and body-mounted wireless communication devices - Human models. instrumentation, and procedures - Part 1: Procedure to measure the Specific Absorption Rate (SAR) for hand-held mobile wireless devices o IEC 62209-2:2019 Human exposure to RF fields from hand-held and body-mounted wireless devices - Human models, instrumentation, and procedures - Part 2: specific absorption rate (SAR) for wireless communication devices (30 MHz - 6 GHz) o D22-012-Tissue dielectric tissue calibration procedure o D28-002-Dipole procedure for validation of SAR system using a dipole o IEEE 1309 Standard for Calibration of Electromagnetic Field Sensors and Probes, Excluding Antennas, from 9 kHz to 40 GHz Conditions Ambient Temperature of the Laboratory: 21 C +/- 0.5C Temperature of the Tissue: 21 C +/- 0.5C Dipole Calibration uncertainty The calibration uncertainty for the dipole is made up of various parameters presented below. Tolerance, % Mechanical 2.00 Positioning Error 0.10 Electrical 0.37 Tissue Permittivity 3.88 Tissue Conductivity 3.56 Dipole Validation 1.70 Combined Uncertainty, k=2 4.81 NCL Calibration Laboratories Division of APREL Laboratories DC-1904 Dipole SN: 825 Page 5 of 7 This page has been reviewed for content and attested to on Page 2 of this document. The Following Graphs are the results as displayed on the Vector Network Analyzer. Electrical Calibration Test Head S11 R/L -19.83 dB Impedance 43.26  SWR 1.23 U S11 Parameter Return Loss Head Frequency Range 2326.59 MHz to 2450 MHz NCL Calibration Laboratories Division of APREL Laboratories DC-1904 Dipole SN: 825 Page 6 of 7 This page has been reviewed for content and attested to on Page 2 of this document. Smith Chart Dipole Impedance Head NCL Calibration Laboratories Division of APREL Laboratories DC-1904 Dipole SN: 825 Page 7 of 7 This page has been reviewed for content and attested to on Page 2 of this document. SWR Head NCL CALIBRATION LABORATORIES Calibration File No: DC-1906 Project Number: 5921 Client.: Celltech Address: 21 – 364 Lougheed Road, Kelowna, BC V1X 7R8, Canada C E R T I F I C A T E OF C A L I B R A T I O N It is certified that the equipment identified below has been calibrated in the NCL CALIBRATION LABORATORIES by qualified personnel following recognized procedures and using transfer standards traceable to NRC/NIST. Validation Dipole (Head) Manufacturer: SPEAG Part number: S5GHzV2 Frequency: 450 MHz Serial No: 1031 C…

Text truncated - open the document above for the full version.

RF Exposure Info

DTS0.71 DSS<0.1 UNII1.14 Simultaneous1.24 General Pop. Limit: 1.60 DTS 0.87 DSS<0.1 UNII0.58 Simultaneous0.68 General Pop. Limit: 4.00 Ben Hewson, President Celltech Labs Inc. IC Registration 3874A 21-364 Lougheed Rd. Olathe, KS, 66062 IC Registration NumberFCC ID: A04853 In Accordance With: A04853 IPH-04853 Product Model Number / HVINProduct Name / PMN © 2024 Celltech Labs Inc, This report shall not be reproduced in any form without the expressed written consent of Celltech Labs Inc. Body (1g) Extremity (10g) USA Kelowna, BC, V1X 7R8 FCC 47 CFR §2.1093 Radiofrequency Radiation Exposure Evaluation: Portable Devices FCC Registration: CA3874 Canada Test Lab Certificate: 2470.01 Approved By: 45461970 R1.0 6 June 2024 Applicant: Garmin International Inc. Test Report Serial Number: Test Report Date: SAR Test Report - New Application 1653 Project Number: Maximum reported SAR W/kg 1200 East 151 St. 45461970 R1.0 Test Report Issue Date: 6 June 2024 ©2024 Celltech Labs Inc. This document is not to be reproduced in whole or in part without the expressed written permission of Celltech Labs Inc. Page 2 of 61 Table of Contents 1.0 REVISION HISTORY ........................................................................................................................................................ 4 2.0 CLIENT AND DEVICE INFORMATION ............................................................................................................................ 5 3.0 SCOPE OF EVALUATION ................................................................................................................................................ 6 4.0 NORMATIVE REFERENCES ........................................................................................................................................... 7 5.0 STATEMENT OF COMPLIANCE ..................................................................................................................................... 8 6.0 SAR MEASUREMENT SYSTEM ...................................................................................................................................... 9 7.0 RF CONDUCTED POWER MEASUREMENT ................................................................................................................ 10 TABLE 7.1 CONDUCTED POWER MEASUREMENTS, WLAN, BT, U-NII .............................................................................................................. 10 8.0 NUMBER OF TEST CHANNELS (N C ) ............................................................................................................................ 11 TABLE 8.1 NUMBER OF TEST CHANNELS ....................................................................................................................................................... 11 TABLE 8.2 ANTENNA DISTANCES ................................................................................................................................................................. 12 TABLE 8.3 BODY SAR TEST EXCLUSION WORKCHART ...................................................................................................................................... 13 TABLE 8.4 EXTREMITY SAR TEST EXCLUSION WORKCHART............................................................................................................................... 13 9.0 ACCESSORIES EVALUATED ........................................................................................................................................ 14 TABLE 9.1 MANUFACTURER’S ACCESSORY LIST .............................................................................................................................................. 14 10.0 SAR MEASUREMENT SUMMARY .............................................................................................................................. 15 TABLE 10.1: MEASURED RESULTS – BODY 1G – 2.4GHZ ................................................................................................................................ 15 TABLE 10.1: MEASURED RESULTS – BODY 1G – NII ....................................................................................................................................... 15 TABLE 10.3: MEASURED RESULTS – EXTREMITY 10G – 2.4GHZ ....................................................................................................................... 16 TABLE 10.4: MEASURED RESULTS – EXTREMITY 10G –U-NII ........................................................................................................................... 16 11.0 SCALING OF MAXIMUM MEASURE SAR ................................................................................................................... 17 TABLE 11.1 SAR SCALING 1G – 2.4GHZ ..................................................................................................................................................... 17 TABLE 11.2 SAR SCALING 1G – U-NII ......................................................................................................................................................... 18 TABLE 11.3 SAR SCALING 10G – 2.4GHZ ................................................................................................................................................... 19 TABLE 11.4 SAR SCALING 10G – U-NII ....................................................................................................................................................... 20 11.5 SIMULTANEOUS TRANSMISSION SAR ANALYSIS ...................................................................................................................................... 22 12.0 SAR EXPOSURE LIMITS ............................................................................................................................................. 23 TABLE 12.1 EXPOSURE LIMITS .....................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Antenna Data Sheet Antenna Manufacturer Information: The antenna(s) for Garmin Model A04853 is a custom designed and manufactured by Garmin International, Inc. (Garmin) with headquarters located at 1200 E. 151 st Street, Olathe, KS, 66062, USA. Garmin is an antenna manufacturer that specializes in antenna construction and has been a technology leader in high performance antenna design for over thirty years. State-of-the art equipment is used as described below to design, measure, and analyze new designs that are superior to competitor designs and highly proprietary in nature. Equipment Description: This data sheet contains the antenna gain information for the antenna(s) for Garmin Model A04853. The approximate operational frequency band of these technologies is given, and the maximum gain within the frequency band is reported. Reported Data: Antenna Model Number Antenna Maximum Gain @ Frequency Antenna Approximate Frequency Band A04853-A1 4.4 dBi @ 2440 MHz 2402 to 2480 MHz Data Sheet Requirements: This data sheet contains the following, as required by the FCC’s Antenna Data Sheet Requirements (Refer to Page 4 of https://transition.fcc.gov/oet/ea/presentations/files/oct22/35-Part-15-Antenna-Updates- TCB_Oct_2022.pdf): •Name and Address of the Manufacturer •Model Number of the Antenna(s) •The Maximum Antenna Gain in the frequency band of operation. Additional Information: Proprietary information regarding antenna design, dimensions, cable length, etc. are provided in the Confidential Operation Description exhibit. A04853-A2 6.0dBi @ 5220 MHz 5180 to 5250 Mhz A04853-A2 6.5dBi @ 5755MHz 5725 to 5850MHZ

Contact Information

Applicant

Ben Karsak(Manager, Compliance Engineering)
[email protected]9134401946Fax: 913 397-8282

Test Firm

Rogers Labs, a division of The Compatibility CntrPatrick Powell
[email protected]913-837-3214Fax: 913-837-3214

Technical Specifications

#Rule PartsFrequency RangePower Output
215E5.75 GHz - 5.83 GHz51.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to belt-clips and holsters that have no metallic components in the assembly and cause the device to operate with the minimum separation distance of 5.0 mm, as described in this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, simultaneous transmission and product specific (10g SAR) exposure conditions are 1.14 W/kg, 1.24 W/kg and 0.58 W/kg, respectively. This device supports 20, 40 and 80 MHz bandwidth modes.

Other Applications from Garmin International Inc

IPH-05126

Portable Digital Transceiver

Sep 09, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
IPH-A5126

Portable Digital Transceiver

Sep 09, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
IPH-04812

Mobile Digital Transceiver

Sep 01, 2026

Equipment Class

DTS - Digital Transmission System
IPH-A04825

Marine Stereo

Sep 01, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
IPH-B04825

Marine Stereo

Sep 01, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter