FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Garmin International Inc/
  3. IPH-04937

IPH-04937Portable Digital Transceiver

Garmin International Inc

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 27, 2026
Application Purpose
Original Equipment
Equipment Note
Portable Digital Transceiver
Frequency Range
2402.00000000 - 2480.00000000
Company
Garmin International Inc
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: February 2, 2026 Ref: Attestation Statements Part 2.911(d)(5) FCC ID: IPH-04937 FRN: 0005088588 Garmin International, Inc., (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited fr om receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Garmin International, Inc., (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as a n entit y producing “covered” equipment. Garmin International, Inc., (“the applicant”) certifies that, the device does not have cybersecurity and/or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, identified on the Covered List installed on the device, nor will it be installed by the applicant after certification. Sincerely, Ben Karsak Manager Compliance Engineering Garmin International, Inc.

Attestation Statements

Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: February 2, 2026 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: IPH-04937 Garmin International, Inc., Garmin certifies that, as of the date of t he filing of the application, Garmin International, Inc. is our designated U.S. agent for service of process for t he above referenced FCC ID. Garmin International, Inc., accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Garmin International, Inc. accepts, as of the date of t he filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: FRN: 0005088588 Name: Garmin International, Inc. Address: 1200 East 151 st Street, O lathe, Kansas, 66062 Contact Person: Ben Karsak Tel.: 913-440-1946 Email: [email protected] Sincerely, Ben Karsak Manager Compliance Engineering

Cover Letter(s)

October 18, 2025 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Innovation, Science and Economic Development Canada Certification and Engineering Bureau 3701 Carling Avenue PO Box 11490, Station H Ottawa, Ontario, Canada K2H 8S2 To Whom It May Concern: Pursuant to 47 CFR 2.911, Garmin International, Inc. (Garmin) has authorized the following Garmin International Associates to act on Garmin's behalf for the sole and express purpose of processing applications to the Federal Communication Commission (FCC) and Innovation, Science and Economic Development Canada (ISED) for equipment authorization or certification. Mr. Niklas Haydon, Compliance Engineering Team Lead Ms. Sara Jones, Design Certification Engineer Mr. Mitchell Phillipi, Compliance Engineering Team Lead Mr. Jacky Yeung, Compliance Engineer Mr. William Pertner, Compliance Engineering Team Lead Mr. Hayden Pernia, Compliance Engineer Mr. Jay Everett, Compliance Engineering Team Lead Mr. Jeremiah Darden, Compliance Engineer Mr. Richard Kockelkoren, Compliance Engineer Mr. Henry Lin, Compliance Engineer Mr. Mike Moranha, Compliance Engineer Ms. Claire Fryman, Compliance Engineer Ms. Pam Sequeira, Compliance Engineer Mr. Rick Jankovics, Compliance Engineer Mr. Jeffrey Hailey, Compliance Engineer Mr. Brodie Halbfoster, Compliance Engineer Mr. Dan Irish, Compliance Engineer Mr. Jonathan Shafer, Design Certification Engineer As such, the Garmin Associates listed above are authorized to: 1) sign Form 731, 2) sign letters of application, 3) request confidentiality, and 4) exchange data and information with the FCC, IC and/or authorized TCBs on behalf of Garmin. In addition, these individuals shall be considered "authorized individuals" to act on Garmin's behalf where an "authorized individual's" attestation is necessary or preferred. This authorization remains in effect until notified to the contrary by Garmin. Sincerely, Ben Karsak Manager Compliance Engineering Garmin International, Inc.

Cover Letter(s)

Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Dat e: Applicant: Request for Confidentiality 2 September, 2025 Garmin International FCC ID: IPH-04937 Pursuant to F CC 47 CFR 0.457(d) and 0.459, and IC RSP-100 Section 12.4, we request that a part of the FCC and ISED application be held confidential. Type Of Confidentiality Requested Exhibit ☐Short Term☒Permanent☐Not Provided Block Diagrams ☐Short Term☒Permanent☐Not Provided Schematics ☐Short Term☒Permanent☐Not Provided Operational Description/ Theory of Operation ☐Short Term☐Permanent☒Not Provided Parts List & Placement/BOM ☐Short Term☒Permanent☐Not Provided Tune-Up Procedure ☒Short Term☐Permanent☐Not Provided Test Setup Photos ☒Short Term☐Permanent☐Not Provided User’s Manual(s) ☒Short Term☐Permanent☐Not Provided External Photos ☒Short Term☐Permanent☐Not Provided Internal Photos Garmin Intern ational has spent a substantial effort in developing this product and it is one of the first of its kind in the industry. Having the subject information easily available to "competition" would negate the advantage we have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidenti ality: Garmin requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality (if applicable): The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Sincerely, Michael Moranha Compliance E ngineer Garmin International

ID Label/Location Info

A04937 Label Drawing and Placement Bottom of device FCC ID: IPH-04937 IC: 1792A-04937 M/N: A04937 Label Device

RF Exposure Info

Test Report# TR_21639-25_Remote BLE_RF Exp SAR Exclusion Revision: 2 Te s t Report - RF Exposure Evaluation Report for SAR Exclusion, Model A04937 Applicant: Garmin International Inc. Signature: Name & Title: Tim Royer, Lab Manager Date of Signature 10/28/2025 Prepared By: Mark Learner, Technical Writer This test report relates only to the items tested as identified and is not valid for any subsequent changes or modifications made to the equipment under test. 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 2 of 8 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) Table of Contents 1. APPLICANT INFORMATION ........................................................................................................................................................................... 3 2. LOCATION OF TESTING ................................................................................................................................................................................. 3 2.1 TEST LABORATORY .................................................................................................................................................................................................... 3 3. TEST SAMPLE(S) (EUT/DUT) ........................................................................................................................................................................... 3 3.1 DESCRIPTION OF THE EUT ........................................................................................................................................................................................4 4. HISTORY OF TEST REPORT CHANGES ........................................................................................................................................................ 7 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 3 of 8 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 1. Applicant Information Applicant: Garmin International Inc. Address: 1200 East 151st Street Olathe, KS 66062, USA 2. Location of Testing 2.1 Test Laboratory IIA Lab Services LLC. is a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”). Testing was performed at IIA’s permanent laboratory located at 13146 NW 86th Drive, Suite 400, Alachua, Florida 32615. FCC test firm # 578780 FCC Designation # US1070 FCC site registration is under A2LA certificate # 0955.01 ISED Canada test site registration # 2056A EU Notified Body # 1177 For all designations see A2LA scope # 0955.01 3. Test Sample(s) (EUT/DUT) The test sample was received: 6/18/2025 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 4 of 8 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 3.1 Description of the EUT A description as well as unambiguous identification of the EUT(s) tested. Where more than one sample is required for technical reasons (such as the use of connected units for the purpose of conducted output power testing where the product units will have integral antennas), each specific test shall identify which unit was tested. Identification Brief Description Portable Digital Transceiver Model(s) # A04937 Firmware version N/A Software version N/A Serial Number N/A Technical Characteristics Frequency Range 2402 – 2480 MHz RF O/P Power (Max.) 16 dBm Modulation GFSK Bandwidth & Emission Class 1.13kHz Number of Channels 37 Duty Cycle 100% Antenna Connector N/A Voltage Rating (AC or Batt.) 12v DC Antenna Characteristics Antenna Frequency Range Mode / BW Antenna Gain 1 n/a n/a 3.07dBi - Note: Information such as antenna gain, firmware/software numbers are provided by manufacturer and cannot be validated by the test lab. 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 5 of 8 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) SAR EXCLUSION CALCULATION: Section 4.3.1 General SAR test exclusion guidance Equation: RSS 102 Issue 6 Section 6.3 Exemption Limits for Routine Evaluation Equation: 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 6 of 8 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) Conclusion: SAR testing is not required Same criteria as Head/Body Ratio 0.49No d (cm):20.00 ERP 20 :7650 x:1.90 P th (mW):7650.00(exposure limit)Ratio TL EIRP:40.99 dBm(12550.51 mW)0.006 TL ERP:38.84 dBm(7650.00 mW)0.004 ERP (mW):48.77Yes! Ratio0.01 Extremity Exposure 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 7 of 8 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 4. History of Test Report Changes Test Report # Revision # Description Date of Issue TR_21639-25_Remote BLE_RF Exp SAR Exclusion_1 1 Initial release 10/28/2025 2 Updated page 6 and 4 04/23/2026 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 8 of 8 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspectio…

Text truncated - open the document above for the full version.

Test Report

Test Report# TR_21639-25_Remote BT_FCC 15.247 DTS_ Revision: 2 Te s t Report - FCC Part 15.247/ DTS FCC ID: IPH-04937 Applicant: Garmin International Inc. Signature: Name & Title: Tim Royer, Lab Manager Date of Signature 12/18/2025 Prepared By: Mark Learner, Technical Writer This test report relates only to the items tested as identified and is not valid for any subsequent changes or modifications made to the equipment under test. 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 2 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) Table of Contents 1. APPLICANT INFORMATION ........................................................................................................................................................................... 4 1.1 TEST RESULT SUMMARY ...................................................................................................................................................................................... 4 2. LOCATION OF TESTING ................................................................................................................................................................................. 6 2.1 TEST LABORATORY .............................................................................................................................................................................................. 6 3. TEST SAMPLE(S) (EUT/DUT) ........................................................................................................................................................................... 6 3.1 DESCRIPTION OF THE EUT ...................................................................................................................................................................................7 3.2 CONFIGURATION OF EUT ................................................................................................................................................................................... 8 3.3 TEST SETUP OF EUT ............................................................................................................................................................................................ 8 4. TEST METHODS & APPLICABLE REGULATORY LIMITS ............................................................................................................................ 9 4.1 TEST METHODS/STANDARDS/GUIDANCE: .......................................................................................................................................................... 9 4.2 APPLIED LIMITS AND REGULATORY LIMITS: ......................................................................................................................................................... 9 5. MEASUREMENT UNCERTAINTY .................................................................................................................................................................... 9 6. ENVIRONMENTAL CONDITIONS ................................................................................................................................................................. 9 6.1 TEMPERATURE & HUMIDITY ................................................................................................................................................................................ 9 7. LIST OF TEST EQUIPMENT AND TEST FACILITY ...................................................................................................................................... 10 7.1 LIST OF TEST EQUIPMENT .................................................................................................................................................................................. 10 8. TEST RESULTS .................................................................................................................................................................................................. 11 8.1 DTS CONDUCTED OUTPUT POWER – 1M .......................................................................................................................................................... 12 8.1.1 Conducted Output Power, 2402 MHz .......................................................................................................................................... 13 8.1.2 Conducted Output Power, 2442 MHz .......................................................................................................................................... 14 8.1.3 Conducted Output Power, 2480 MHz .......................................................................................................................................... 15 8.2 DTS CONDUCTED OUTPUT POWER – CODED ................................................................................................................................................... 16 8.2.1 Conducted Output Power, 2402 MHz .......................................................................................................................................... 17 8.2.2 Conducted Output Power, 2442 MHz .......................................................................................................................................... 18 8.2.3 Conducted Output Power, 2480 MHz .......................................................................................................................................... 19 8.3 OCCUPIED BANDWIDTH – 1M .......................................................................................................................................................................... 20 8.3.1 99% Bandwidth Plot, 2402 MHz .............................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Antenna Data Sheet Antenna Manufacturer Information: Antenna(s) are manufactured and designed at Garmin headquarters located at 1200 E. 151 st Street, Olathe, KS, 66062, USA. Garmin is an antenna manufacturer that specializes in antenna construction and has been a technology leader in high performance antenna design for over thirty years. State-of-the art equipment is used to design, measure, and analyze new designs that are superior to competitor designs and highly proprietary in nature. Antenna Description: This data sheet contains the antenna gain information for the A04937-A1 for Garmin Model A04937. The approximate operational frequency band of these technologies is given, and the maximum gain within the frequency band is shown in table 1. Table 1 Antenna Gain: Antenna Model Number Antenna Type Antenna Maximum Gain @ Frequency Antenna Approximate Frequency Band A04937-A1 Inverted F 3.07 dBi @ 2480 MHz 2350 to 2530 MHz Additional Information: Contact Garmin for other information regarding antenna design, dimensions, cable length, etc.

Test Report

13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 53 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) Band-edge Spectrum Plots 8.11.1 Lower Band Edge Plot 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 54 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.11.2 Upper Band Edge Plot Tuned Frequency (MHz) Emission Frequency (MHz) 15.205 Restricted Band 15.205, 15.35, 15.247(d) Detector Fundamental Field Strength (dBμV/m) Delta (dBm) Field Strength (dBμV/m) Limit (dBμV/m) Margin (dB) 2480.002484.49XPK84.7867.2917.4973.9856.49 2480.002484.49XPK78.5867.2911.2973.9862.69 2480.002484.49XAVG68.4867.291.1953.9852.79 2480.002484.49XAVG61.1867.29-6.1153.9860.09 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 55 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.12 Band-edge measurements – Coded Requirement from FCC KDB 558074 D01 and test procedure from ANSI C63.10-2020 section 7.8 or 11.13 as applicable. Conducted Test Setup Radiated Test Setup, 30 – 1000 MHz Radiated Test Setup, Above 1000 MHz 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 56 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) Band-edge Spectrum Plots 8.12.1 Lower Band Edge Plot 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 57 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.12.2 Upper Band Edge Plot Tuned Frequency (MHz) Emission Frequency (MHz) 15.205 Restricted Band 15.205, 15.35, 15.247(d) Detector Fundamental Field Strength (dBμV/m) Delta (dBm) Field Strength (dBμV/m) Limit (dBμV/m) Margin (dB) 2480.002483.92XPK77.8162.3215.4973.9858.49 2480.002483.92XPK82.0162.3219.6973.9854.29 2480.002483.92XAVG75.5162.3213.1953.9840.79 2480.002483.92XAVG80.1162.3217.7953.9836.19 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 58 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.13 Radiated Emissions Restricted Bands from FCC Part 15.205; Limits from FCC Part 15.209 Radiated Test Setup, Below 30 MHz Radiated Test Setup, 30 – 1000 MHz Radiated Test Setup, Above 1000 MHz 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 59 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) Radiated Emissions in Restricted Bands, Tabular Data 8.13.1 Radiated Emissions 9 kHz - 30 MHz No emissions were noted within 20dB of the limit. 8.13.2 Radiated Emissions 30-1000 MHz See test report: TR_21639-25_Remote_FCC 15B_1 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 60 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.13.3 Radiated Emissions, 2402 MHz – 1M 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 100015002000250030003500400045005000550060006500700075008000850090009500 100001050011000115001200012500130001350014000145001500015500160001650017000175001800018500190001950020000205002100021500220002250023000235002400024500 25000 Field Strength (dBμV/m) Frequency (MHz) Peak Field Strength of Radiated Emissions in Restricted Bands @ 3m PK Field Strength (dBμV/m)15.35 PK Limit (dBμV/m) 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 61 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 100015002000250030003500400045005000550060006500700075008000850090009500 100001050011000115001200012500130001350014000145001500015500160001650017000175001800018500190001950020000205002100021500220002250023000235002400024500 25000 Field Strength (dBμV/m) Frequency (MHz) Average Field Strength of Radiated Emissions in Restricted Bands @ 3m AVG Limit (dBμV/m)AVG Field Strength (dBμV/m) 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 62 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) Tuned Frequency (MHz) Emission Frequency (MHz) 15.205 Restricted Band 15.205, 15.35, 15.247(d) Meter Reading (dBμV) Antenna Polarity Coax Loss (dB) Duty Cycle Correction (dB) Antenna Correction Factor Distance (m) Field Strength (dBμV/m) Limit (dBμV/m) Margin (dB) 2402.002385.00XPK1.40H5 .620.0032.103.0039.1173.9834.87 2402.002385.00XPK0.80V5.620.0032.103.0038.5173.9835.47 2402.002385.00XAVG-14.70H5.620.0032.103.0023.0153.9830.97 2402.002385.00XAVG-14.70V5.620.0032.103.0023.0153.9830.97 2402…

Text truncated - open the document above for the full version.

Test Report

13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 34 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.6.2 6dB Bandwidth (DTS BW), 2442 MHz 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 35 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.6.3 6dB Bandwidth (DTS BW), 2480 MHz 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 36 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.7 Power Spectral Density (PSD) – 1M Limits from FCC Part 15.247 (e) and test procedure from ANSI C63.10-2020 section 11.10. Conducted Test Setup Tuned Frequency (MHz) PSD Level (dBm) 2402 -2.31 2442 -2.39 2480 -2.62 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 37 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.7.1 Power Spectral Density (PSD), 2402 MHz 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 38 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.7.2 Power Spectral Density (PSD), 2442 MHz 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 39 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.7.3 Power Spectral Density (PSD), 2480 MHz 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 40 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.8 Power Spectral Density (PSD) – Coded Limits from FCC Part 15.247 (e) and test procedure from ANSI C63.10-2020 section 11.10. Conducted Test Setup Tuned Frequency (MHz) PSD Level (dBm) 2402 7.94 2442 7.99 2480 7.62 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 41 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.8.1 Power Spectral Density (PSD), 2402 MHz 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 42 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.8.2 Power Spectral Density (PSD), 2442 MHz 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 43 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.8.3 Power Spectral Density (PSD), 2480 MHz 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 44 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) 8.9 Emissions in Nonrestricted Frequency Bands (Out of Band) – 1M Limits from FCC Part 15.247 (d) and 15.215 (b) and test procedure from ANSI C63.10-2020 section 7.8 or 11.11 as applicable. Conducted Test Setup 13146 NW 86 th Drive, Suite 400, Alachua, Florida 32615 (352) 472-5500 / [email protected] Page 45 of 79 This test report shall not be reproduced except in full without the written and signed permission of IIA Lab Services LLC. a subsidiary of Industrial Inspection & Analysis, Inc. (“IIA”) Conducted Emissions in Non-Restricted Ba…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ben Karsak(Manager, Compliance Engineering)
[email protected]Fax: 913 397-8282

Technical Contact

Garmin International, Inc.Ben Karsak
[email protected]

1200 East 151 st Street · Olathe, 66062 · United States

Test Firm

IIA LAB SERVICES, LLCBruno Clavier
[email protected]Fax: 352 472 2030

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz25.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power.

Other Applications from Garmin International Inc

IPH-05126

Portable Digital Transceiver

Sep 09, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
IPH-A5126

Portable Digital Transceiver

Sep 09, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
IPH-04812

Mobile Digital Transceiver

Sep 01, 2026

Equipment Class

DTS - Digital Transmission System
IPH-A04825

Marine Stereo

Sep 01, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
IPH-B04825

Marine Stereo

Sep 01, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter