
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 1 External Photographs State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 4 Label Sample State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Label sample Label location State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 2 Internal Photographs State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 3350.32 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 3350.33 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 3350.36
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 3 Occupied Bandwidth Plot State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 20 dB Bandwidth (transceiver, 315 MHz) (for all Variants nearly the same, the worst case was recorded) State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 99 % Bandwidth (for all Variants nearly the same, the worst case was recorded) State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 20 dB Bandwidth (transmitter, 21.8 kHz) (for all Variants nearly the same, the worst case was recorded) State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 99% Bandwidth (transmitter, 21.8 kHz) (for all Variants nearly the same, the worst case was recorded)
Test report no. 10006126 Page 1 of 21 EUT: 3350.33 FCC ID: IYZ335033 Date of issue: 2010-06-10 State: 2008-04-21 Vers. no.: 1. 08 m. dudde hochfrequenz - technik Rottland 5a D-51429 Bergisch Gladbach Tel. +49 2207-96890 Fax +49 2207 968920 DAT-P-225/96 Test Report acc. to the relevant standard 47 CFR Part 15 C – Intentional Radiators Measurement Procedure: ANSI C63.4-2003 relating to Marquardt GmbH 3350.33 Variants: 3350.32 3350.36 Methods of Measurement of Radio- Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range 9 kHz to 40 GHz DAT-P-225/96 Test report no. 10006126 Page 2 of 21 EUT: 3350.33 FCC ID: IYZ335033 Date of issue: 2010-06-10 State: 2008-04-21 Vers. no.: 1. 08 m. dudde hochfrequenz - technik Rottland 5a D-51429 Bergisch Gladbach Tel. +49 2207-96890 Fax +49 2207 968920 Manufacturer’s details Manufacturer Marquardt GmbH Manufacturer‟s grantee code IYZ Manufacturer‟s address Schloß Straße 16 D-78604 Rietheim-Weilheim Germany Phone: +49(0)7424 99 1867 Fax: +49(0)7424 99 2122 e-mail: [email protected] Relevant standard used 47 CFR Part 15C - Intentional Radiators ANSI C63.4-2003 Test report prepared by Technical engineer Ralf Trepper m.dudde hochfrequenz-technik (laboratory) Rottland 5a 51429 Bergisch Gladbach Germany Phone: +49 (0) 2207 96 89-0 Fax: +49 (0) 2207 96 89-20 E-mail: [email protected] Equipment Under Test (EUT) Equipment category Inductive transmitter Trade name Marquardt Type designation 3350.33 Serial no. --- Variants 3350.32 3350.36 Test report no. 10006126 Page 3 of 21 EUT: 3350.33 FCC ID: IYZ335033 Date of issue: 2010-06-10 State: 2008-04-21 Vers. no.: 1. 08 m. dudde hochfrequenz - technik Rottland 5a D-51429 Bergisch Gladbach Tel. +49 2207-96890 Fax +49 2207 968920 1. Test result summary CFR Section Report Chapter Requirements Headline Test result 15.203 11.1 Antenna requirement Pass Fail N.t. 15.205 (a) 15.209 11.2 11.3 Restricted bands of operation Radiated emission limits, general requirements (LF transmitter part of the EUT) Pass Fail N.t. The equipment meets the requirements Yes No Signature Manager ................................... Manfried Dudde Signature Technician ................................. Ralf Trepper Test report no. 10006126 Page 4 of 21 EUT: 3350.33 FCC ID: IYZ335033 Date of issue: 2010-06-10 State: 2008-04-21 Vers. no.: 1. 08 m. dudde hochfrequenz - technik Rottland 5a D-51429 Bergisch Gladbach Tel. +49 2207-96890 Fax +49 2207 968920 Table of contents 1. Test result summary .......................................................................................................................................... 3 2. Test laboratory .................................................................................................................................................. 5 3. Introduction ...................................................................................................................................................... 5 4. Product ............................................................................................................................................................. 6 5. Test schedule .................................................................................................................................................... 6 6. Product and measurement documentation ......................................................................................................... 7 7. Observations and comments ............................................................................................................................. 7 8. Summary........................................................................................................................................................... 7 9. Conclusions ...................................................................................................................................................... 8 10. Operational description .................................................................................................................................. 9 11.1 Antenna requirement .................................................................................................................................... 10 11.1.1 Regulation ........................................................................................................................................... 10 11.1.2 Result .................................................................................................................................................. 10 11.2 Restricted bands of operation ...................................................................................................................... 11 11.2.1 Regulation ........................................................................................................................................... 11 11.2.2 Result .................................................................................................................................................. 13 11.3 Radiated emission limits, general requirements .......................................................................................... 14 11.3.1 Regulation ........................................................................................................................................... 14 11.3.2 Test equipment ................................................................................................................................... 15 11.3.3 Test procedure .................................................................................................................................... 16 11.3.4 Calculation of the field strength ......................................................................................................... 17 11.3.5 Test result ....................................................................................................................…
Text truncated - open the document above for the full version.
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 6 Test Setup Photographs State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.21845 MHz - 0.21845 MHz | - |
vehicle key
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterECU Electronic Control Unit
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterNFC Reader for car access
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterPassive entry vehicle key
Equipment Class
DTS - Digital Transmission SystemNFC Door Handle Sensor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter