IYZGR2NFC reader

Marquardt GmbH
NFC reader - FCC ID IYZGR2 - Marquardt GmbH
Click to zoom

Application Details

Equipment Class
JAB - Part 15 Class B Digital Device
Date of Grant
Aug 20, 2023
Application Purpose
Original Equipment
Date of Application
Aug 20, 2023
Equipment Note
NFC reader
Company
Marquardt GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GR2 Technical Description Editor : X. Gong Department : SDYE-A-SH Tel. : 86 21 58973302- 9412 Fax. : Email : [email protected] Original version : 05.19.2023 Revision : 05.19.2023 Version : 1.0 Technical Description GR2 Functional description The GR2 (NFC reader) is a component of a driving authorisation system of a car. When the authorized digital key is close to GR2, it sends authorization data to the control unit to execute the access request like Door lock/unlock. NFC Reader PCB is fixed on decoration board through four location holes by hot melting plastic pins on the decoration board. The decoration board is then installed at driver side window frame in car. This device is not freely available on the market and is installed only by trained specialized personnel from the car manufacturer. To avoid risk of fire, please just connect the product to a power supply of which output capability is less than 15W. Technical Description GR2 Technical Data: Operating Voltage: 9 ~ 16v DC Operating temperature: -40 ~ +85 degree PCB dimension: (71+79.4)*145.5/2 mm Frequency: 13.56MHz Technical Description GR2 FCC Regulations: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: âš« Reorient or relocate the receiving antenna. âš« Increase the separation between the equipment and receiver. âš« Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. âš« Consult the dealer or an experienced radio/TV technician for help. FCC Caution: ➢ Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. ISED Notice  This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device.  Le prĂ©sent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisĂ©e aux deux conditions suivantes: 1) l'appareil ne doit pas produire de brouillage, et 2) l'utilisateur de l'appareil doit accepter tout brouillage radioĂ©lectrique subi, mĂŞme si le brouillage est susceptible d'en compromettre le fonctionnement.  This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except tested built-in radios.  Cet appareil et son antenne ne doivent pas ĂŞtre situĂ©s ou fonctionner en conjonction avec une autre antenne ou un autre Ă©metteur, exception faites des radios intĂ©grĂ©es qui ont Ă©tĂ© testĂ©es.  The County Code Selection feature is disabled for products marketed in the US/ Canada.  La fonction de sĂ©lection de l'indicatif du pays est dĂ©sactivĂ©e pour les produits commercialisĂ©s aux États-Unis et au Canada. Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled Technical Description GR2 environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. DĂ©claration d'exposition aux radiations: Cet Ă©quipement est conforme aux limites d'exposition aux rayonnements IC Ă©tablies pour un environnement non contrĂ´lĂ©. Cet Ă©quipement doit ĂŞtre installĂ© et utilisĂ© avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.

Attestation Statements

Rev 1/26/2023 Marquardt GmbH Schloss-str.16,78604 Rietheim-Weilheim,Germany Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 10,2023 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: IYZGR2 Marquardt GmbH (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Gerd Villing Tel: 00497424991747 Fax: 00497424992122 E-mail: [email protected] Rev 1/26/2023 Marquardt GmbH Schloss-str.16,78604 Rietheim-Weilheim,Germany Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 10,2023 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: IYZGR2 Marquardt GmbH (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered”equipment. Sincerely, Gerd Villing Tel: 00497424991747 Fax: 00497424992122 E-mail: [email protected]

Attestation Statements

Rev 1/26/2023 Marquardt GmbH Schloss-str.16,78604 Rietheim-Weilheim,Germany Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 10,2023 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: IYZGR2 Marquardt GmbH (“the applicant”) certifies that, as of the date of the filing of the application, Marquardt Switches,Inc is our designated U.S. agent for service of process for the above referenced FCC ID. Marquardt GmbH accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Marquardt Switches,Inc accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Marquardt Switches,Inc U.S. Agent FRN: The agent for service of process does no other business with the FCC and does not have an FRN. Address: 2990 Waterview Drive ,Rochester Hills,MI 48309,USA Contact Person: Michael Fera Tel.: Michael Fera Email: [email protected] Sincerely, Marquardt GmbH Marquardt Switches,Inc Gerd Villing Michael Fera Michael FeraGerd Villing Applicant FRN: 0007486251

Cover Letter(s)

Marquardt GmbH Schloss-str.16,78604 Rietheim-Weilheim,Germany Date: August 14, 2023 Federal Communications Commission 7435 Oakland Mills Road - Gate A Columbia, Maryland 21046 Subject: Request for Confidentiality FCC ID: IYZGR2 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission’s rules (47CFR§§0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. âš« Schematic Diagram âš« Block Diagram âš« Parts List âš« Operational Description Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFT §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachments until 180 days after the Grant Date of Equipment Authorizations. â—† External Photos â—† Internal Photos â—† Test Setup Photos â—† Users Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards, Gerd Villing Tel: 00497424991747 Fax: 00497424992122 E-mail: [email protected]

Cover Letter(s)

Marquardt GmbH Schloss-str.16,78604 Rietheim-Weilheim,Germany Date: August 14, 2023 Power of Attorney To whom it may concern, Please be notified that I, Gerd Villing, have designated Joey Lao of Bureau Veritas 7Layers Communications Technology (Shenzhen) Co., Ltd as the person being responsible for this project and to sign the form 731 and other documentation. Any and all acts carried out by Joey Lao of Bureau Veritas 7Layers Communications Technology (Shenzhen) Co. Ltd on the matters relating to all processes required in the FCC approval and any communication needed with the national authority, shall have the same legal authority as acts on our own behalf. As defined in 47 CFR Ch. 1.U.S.C. 862, we further certify that neither the applicant nor any party to this application is subject to a denial to Federal benefits, including FCC benefits, pursuant to section 5301 of the Anti-Drug Abuse Act. This authorization is limited to the product of as following: FCC ID: IYZGR2 If you have any acknowledgement and response, please send it to Joey Lao of Bureau Veritas 7Layers Communications Technology (Shenzhen) Co., Ltd directly. Should you have any question or comment regarding this matter, please have my best attention. Sincerely yours, Gerd Villing Tel: 00497424991747 Fax: 00497424992122 E-mail: [email protected]

External Photos

BV 7Layers Communications Technology (Shenzhen) Co., Ltd No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, China Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected] Page 1 of 1 Report Version 1 Reference No.: W7L-P23030026 FCC ID: IYZGR2 PHOTOGRAPHS OF THE EUT

ID Label/Location Info

CONFIDENTIAL© This documentistheexclusivepropertyofMarquardt. Withoutourconsent, itmaynot bereproducedorgiventothirdparties. 1| MARQUARD T1 6 .0 8 .2 0 2 3| NFCR V216

Internal Photos

BV 7Layers Communications Technology (Shenzhen) Co., Ltd No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, China Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected] Page 1 of 2 Report Version 1 Reference No.: W7L-P23030026 FCC ID: IYZGR2 PHOTOGRAPHS OF THE EUT BV 7Layers Communications Technology (Shenzhen) Co., Ltd No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, China Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected] Page 2 of 2 Report Version 1 Reference No.: W7L-P23030026 FCC ID: IYZGR2

RF Exposure Info

FCC RF Exposure Test Report Report Format Version 5.0.0 Issued Date : Jun. 25, 2023 Report No. : W7L-P23030026SA01 FCC RF Exposure Test Report Report No. : W7L-P23030026SA01 Applicant : Marquardt GmbH Address : Schloss-str.16,78604 Rietheim-Weilheim,Germany Manufacturer : Marquardt GmbH Address : Schloss-str.16,78604 Rietheim-Weilheim,Germany Product : NFC reader FCC ID : IYZGR2 Brand : Marquardt Model No. : GR2 Standards : FCC Part 2 (Section 2.1091) KDB 447498 D01 General RF Exposure Guidance v06 Sample Received Date : Apr. 13, 2023 Date of Testing : Apr. 14, 2023 ~ May. 10, 2023 CERTIFICATION: The above equipment have been tested by BV 7LAYERS COMMUNICATIONS TECHNOLOGY (SHENZHEN) CO., LTD., and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s SAR characteristics under the conditions specified in this report. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval, or endorsement by A2LA or any government agencies. Prepared By : Approved By : Jerry Chen / Engineer Luke Lu / Manager This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about- us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. FCC RF Exposure Test Report Report Format Version 5.0.0 Issued Date : Jun. 25, 2023 Report No. : W7L-P23030026SA01 Table of Contents RELEASE CONTROL RECORD .................................................................................................................................................... 3 1. DESCRIPTION OF EQUIPMENT UNDER TEST .................................................................................................................... 4 2. RF EXPOSURE EXEMPTION EVALUATION ......................................................................................................................... 5 2.1 INTRODUCTION .......................................................................................................................................................... 5 2.2 RF RADIATION EXPOSURE LIMITS ........................................................................................................................... 5 2.3 MPE ASSESSMENT METHOD .................................................................................................................................... 6 2.4 MPE CALCULATION FOR STANDALONE OPERATIONS .......................................................................................... 6 3. INFORMATION ON THE TESTING LABORATORIES ........................................................................................................... 8 FCC RF Exposure Test Report Report Format Version 5.0.0 Issued Date : Jun. 25, 2023 Report No. : W7L-P23030026SA01 Release Control Record Report No. Reason for Change Date Issued W7L-P23030026SA01 Initial release May. 10, 2023 FCC RF Exposure Test Report Report Format Version 5.0.0 Issued Date : Jun. 25, 2023 Report No. : W7L-P23030026SA01 1. Description of Equipment Under Test EUT Type NFC reader FCC ID IYZGR2 Brand Name Marquardt Model Name GR2 Tx Frequency Bands (Unit: MHz) NFC : 13.56 MHz Uplink Modulations NFC : ASK Antenna Type PCB Antenna EUT Stage Production Unit Note: 1. The above EUT information is declared by manufacturer and for more detailed features description please refers to the manufacturer's specifications or User's Manual. FCC RF Exposure Test Report Report Format Version 5.0.0 Issued Date : Jun. 25, 2023 Report No. : W7L-P23030026SA01 2. RF Exposure Exemption Evaluation 2.1 Introduction According to 47 CFR §2.1091, a mobile device is defined as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 cm is normally maintained between the transmitting antenna and the body of the user or nearby persons. In this context, the term “fixed location” means that the device is physically secured at one location and is not able to be easily moved to another location. Transmitting devices designed to be used by consumers or workers that can be easily re-located, such as wireless devices associated with a personal computer, are considered to be mobile devices if they meet the 20 cm separation requirement. The limits to be used for MPE evaluation are specified in §1.1310…

Text truncated - open the document above for the full version.

Test Report

Antenna Information:V216 Applicant information Marquardt GmbH Scholss-Strasse 16, 78604 Rietheim-Weilheim, Germany Frequency Range(MHz) 13.56MHz VSMR ≤1.5 Gain(dBi) 0 Input Impedance(Ω) 50Ω Connector Type PCB antenna which permanently attached Antenna Size Approx 110*30 mm Polarization Type Omnidirection

Test Report

BV 7Layers Communications Technology (Shenzhen) Co., Ltd No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected] Page 1 of 15 Report Version 1 Test Report No.: W7L-P23030026EM02 EMC TEST REPORT Applicant: Marquardt GmbH Address: Schloss-str.16,78604 Rietheim-Weilheim,Germany Manufacturer or Supplier: Marquardt GmbH Address: Schloss-str.16,78604 Rietheim-Weilheim,Germany Product: NFC reader Brand Name: Marquardt Model Name: GR2 FCC ID: IYZGR2 Date of tests: Apr. 14, 2023 ~ May. 10, 2023 The submitted sample of the above equipment has been tested for according to the requirements of the following standards: FCC Part 15, Subpart B, Class A FCC Part 15, Subpart B, Class B ANSI C63.4:2014 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Prepared by Simon Wang Engineer / Mobile Department Approved by Luke Lu Manager / Mobile Department Date: May. 10, 2023 Date: May. 10, 2023 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. BV 7Layers Communications Technology (Shenzhen) Co., Ltd No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected] Page 2 of 15 Report Version 1 Test Report No.: W7L-P23030026EM02 TABLE OF CONTENTS RELEASE CONTROL RECORD .......................................................................................................................... 3 1 GENERAL INFORMATION ........................................................................................................................... 4 1.1 GENERAL DESCRIPTION OF EUT ...................................................................................................... 4 1.2 SUMMARY OF TEST RESULTS ............................................................................................................. 5 2.1 MEASUREMENT UNCERTAINTY ........................................................................................................ 5 2.1 DESCRIPTION OF TEST MODES ........................................................................................................ 6 2.1 DESCRIPTION OF SUPPORT UNITS ................................................................................................. 7 2 EMISSION TEST ............................................................................................................................................. 8 2.1 RADIATED EMISSION MEASUREMENT ............................................................................................ 8 2.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT ............................................................... 8 2.1.2 TEST INSTRUMENTS .................................................................................................................... 9 2.1.3 TEST PROCEDURE ..................................................................................................................... 10 2.1.4 DEVIATION FROM TEST STANDARD ....................................................................................... 11 2.1.5 TEST SETUP ................................................................................................................................. 12 2.1.6 EUT OPERATING CONDITIONS ................................................................................................ 12 2.1.7 TEST RESULTS............................................................................................................................. 13 3 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB .......................................................................................................................................................... 15 BV 7Layers Communications Technology (Shenzhen) Co., Ltd No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected] Page 3 of 15 Report Version 1 Test Report No.: W7L-P23030026EM02 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED W7L-P23030026EM02 Original release May. 10, 2023 BV 7Layers Communications Technol…

Text truncated - open the document above for the full version.

Test Setup Photos

BV 7Layers Communications Technology (Shenzhen) Co., Ltd No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected] Page 1 of 1 Report Version 1 Reference No.: W7L-P23030026 FCC ID: IYZGR2 SET-UP FOR RADIATED EMISSION TEST Frequency Range< 30MHz ~1GHz >

Contact Information

Applicant

Gerd Villing
[email protected]00497424991747Fax: 00497424992122

Test Firm

BV 7Layers Communications Technology (Shenzhen) CoEdwin Ye
[email protected]86-20-8714 8549

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from Marquardt GmbH

IYZZK1

vehicle key

Jul 23, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
IYZZE1

ECU Electronic Control Unit

Jul 01, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
IYZOR1

NFC Reader for car access

Mar 05, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
IYZGK2A

Passive entry vehicle key

Dec 11, 2025

Equipment Class

DTS - Digital Transmission System
IYZ-NH3

NFC Door Handle Sensor

Dec 09, 2025

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter