FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Marquardt GmbH/
  3. IYZHH6

IYZHH6HH6 SV

Marquardt GmbH

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jun 19, 2024
Application Purpose
Original Equipment
Date of Application
Jun 19, 2024
Equipment Note
HH6 SV
Frequency Range
13.56000000 - 13.56000000
Company
Marquardt GmbH
Country
Germany

Documents & Files

Select a file to view

Attestation Statements

β†—
β†—
β†—

Cover Letter(s)

β†—
β†—

ID Label/Location Info

β†—

RF Exposure Info

β†—

Test Report

β†—
β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

FRN: 0007486251 Applicant:Company Name: Marquardt GmbHAddress: Schloss-Straße 16 78604 Rietheim-Weilheim, Germany Contact name: Gerd, VillingTel.: 00497424991747 Email: [email protected]

ID Label/Location Info

Label draft – HH6 2024-06-13_Label_Draft-HH6.docx page 1 of 2 IYZHH6 2701A-HH6 HH6 Label draft – HH6 2024-06-13_Label_Draft-HH6.docx page 2 of 2

RF Exposure Info

FCC ID: IYZHH6 According to KDB 447498 D04 Interim General RF Exposure Guidance v01 1. 1-mW Test Exemption Per Β§ 1.1307(b)(3)(i)(A), a single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1 ㎽, regardless of separation distance. This exemption applies to all operating configurations and exposure conditions, for the frequency range 100 γŽ‘ to 100 γŽ“, regardless of fixed, mobile, or portable device exposure conditions. This is a standalone exemption, and it cannot be applied in conjunction with any other test exemption. 2. Test Result Frequency Range (γŽ’) Radiated Power (㏈uV/m) ERP (㏈m) ERP (㎽) Limit (㎽) Result 13.56 65.17 -32.21 0.000 603 1 Pass Note; According to ANSI C63.10 Annex G.2 ERP(W) = p t x g t = (Exd) 2 / 49.2 Where; p t is the transmitter output power in watts g t is the numeric gain of the transmitting antenna (dimensionless) E is the electric field strength in V/m d is the measurement distance in meters (m) V/m = 10 (dBuV)-120)/20) 3. Conclusion: No SAR is required.

Test Report

SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Te l . + 82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL005153 Page: 2 of 24 RTT7081-02(2020.10.05)(0) A4(210 mmx297 mm) INDEX Table of contents 1. General Information ----------------------------------------------------------------------------------- 3 2. Radiated Emissions ------------------------------------------------------------------------ ----------- 7 3. Frequency Stability --------------------------------------------------------------- --------------------- 18 4. 20 ㏈ Bandwidth & 99 % Bandwidth ---------- --------------------------------------------------- 23 SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Te l . + 82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL005153 Page: 3 of 24 RTT7081-02(2020.10.05)(0) A4(210 mmx297 mm) 1. General Information 1.1. Testing Laboratory SGS Korea Co., Ltd. (Gunpo Laboratory) - 10-2, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 - 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 - Designation number: KR0150 All SGS services are rendered in accordance with the applicable SGS conditions of service available on request and accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx. Phone No. : +82 31 688 0901 Fax No. : +82 31 688 0921 1.2. Details of Applicant FCC Applicant : Marquardt GmbH FCC Address : Schloss - Str. 16, Rietheim - Weilheim, Germany, 78604 IC Applicant : MARQUARDT GMBH IC Address : Schloss-Str. 16, Rietheim-Weilheim, Germany (Federal Republic Of), 78604 Contact Person : Gerd, Villing Phone No. : 49 74 2499 1747 1.3. Details of manufacturer Company : Marquardt GmbH Address : Schloss - Str. 16, Rietheim - Weilheim, Germany, 78604 1.4. Description of EUT Kind of Product HH6 SV Model Name HH6 Serial Number 124101094590834 Power Supply DC 12 V Frequency Range 13.56 γŽ’ (NFC) Modulation Technique ASK Number of Channels 1 channel Antenna Type PCB trace antenna Antenna Part Number N/A H/W Version 749 S/W Version F FVIN N/A SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Te l . + 82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL005153 Page: 4 of 24 RTT7081-02(2020.10.05)(0) A4(210 mmx297 mm) 1.5. Test Equipment List Equipment Manufacturer Model S/N Cal. Date Cal. Int erval Cal. Due Signal Generator R&S SMBV100A 259067 Jun. 15, 2023 Annual Jun. 15, 2024 DC Power Supply R&S HMP2020 102130 May 02, 2024 Annual May 02, 2025 DC Power Supply Agilent U8002A MY49030063 Jan. 17, 2024 Annual Jan. 17, 2025 Temperature Chamber ESPEC CORP. PL-1J 15000796 Dec. 01, 2023 Annual Dec. 01, 2024 Spectrum Analyzer R&S FSW8 101660 May 23, 2024 Annual May 23, 2025 Spectrum Analyzer Agilent N9020A MY53421758 Sep. 01, 2023 Annual Sep. 01, 2024 Amplifier H.P. 8447F 2944A03909 Aug. 04, 2023 Annual Aug. 04, 2024 Loop Antenna Schwarzbeck Mess-Elektronik FMZB 1519 1519-039 Aug. 21, 2023 Biennial Aug. 21, 2025 Bilog Antenna Schwarzbeck Mess-Elektronik VULB 9163 9163-437 May 29, 2024 Biennial May 29, 2026 EMI Test Receiver R&S ESU26 100109 Jan. 16, 2024 Annual Jan. 16, 2025 Turn Table Innco systems GmbH DS 1200 S N/A N.C.R. N/A N.C.R. Controller Innco systems GmbH CONTROLLER CO3000-4P CO3000/963/3833 0516/L N.C.R. N/A N.C.R. Antenna Mast Innco systems GmbH MA4640-XP-ET MA4640/536/3833 0516/L N.C.R. N/A N.C.R. Anechoic Chamber SY Corporation L Γ— W Γ— H (9.6 m Γ— 6.4 m Γ— 6.6 m) N/A N.C.R. N/A N.C.R. Coaxial Cable SENSORVIEW NMST-13A26-NMST-5 m TPC2402190004 Apr. 03, 2024 Semi- Annual Oct. 03, 2024 Coaxial Cable SENSORVIEW NMST-13A26-NMST-10 m TPC2402190001 Apr. 03, 2024 Semi- Annual Oct. 03, 2024 Coaxial Cable RADIALL TESTPRO 3 182287 Apr. 12, 2024 Semi- Annual Oct. 12, 2024 Note; - For equipment listed above that has a calibration date or calibration due date that falls within the test date range, care was taken to ensure that this equipment was used after the calibration date and before the calibration due date. SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Te l . + 82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL005153 Page: 5 of 24 RTT7081-02(2020.10.05)(0) A4(210 mmx297 mm) 1.6. Summary of Test Results The EUT has been tested according to the following specifications: Applied standard : FCC Part15 subpart C, IC RSS-210 Issue 10, RSS-Gen Issue 5 Section in FCC Section in IC Test item(s) Result 15.225(a)(b)(c)(d) 15.209 RSS-210 Issue 10 B.6 RSS-Gen Issue 5 8.9 Radiated Emission, Spurious Emission and Field Strength of Fundamental Complied 15.225(e) RSS-210 Issue 10 B.6 RSS-Gen Issue 5 6.11 Frequency Stability Complied 15.215(c) RSS-Gen Issue 5 6.7 20 ㏈ Bandwidth & 99 % Bandwidth Complied 15.207 RSS-Gen Issue 5 8.8 AC Power Line Conducted Emissions N/A 1) Note; 1) The AC power line test was not performed because the EUT use battery power for operation and which do not operate from the AC power lines. 1.7. Sample calculation Where relevant, the following sample calculation is provided: 1.7.1. Radiation test Field strength level (㏈㎢/m) = Measured level (㏈㎢) + Antenna factor (㏈/m) + Cable loss (㏈) - Amplifier gain (㏈) 1.8. Information of software for test. Using the software of Internal to testing of EUT. SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Te l . + 82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL005153 Page: 6 of 24 RTT7081-02(2020.10.05)(0) A4(210 mmx297 mm) 1.9. Measurement Uncertainty Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the apparatus: Parameter Uncertainty 99 % Bandwidth 0.04 γŽ‘ 20 ㏈ Bandwidth 0.04 γŽ‘ Frequency Stability 0.11 γŽ‘ Radiated Emission, 9 γŽ‘ to 30 γŽ’ H 3.60 ㏈ V 3.60 ㏈ Radiated Emission, below 1 γŽ“ H 4.60 ㏈ V 4.90 ㏈ All measurement uncertainty values are shown with a…

Text truncated - open the document above for the full version.

Test Report

Model name: HH6 <NFC> Item Contents Antenna Type PCB trace Antenna Antenna peak gain - ㏈i Manufacturer Marquardt GmbH Address of manufacturer Schloss - Str. 16, 78604 Rietheim - Weilheim, Germany, 78604 Model name Test laboratory - Size Information Length : 1.6 cm / Width :5.0 cm Antenna Information Width 5.0cm Length 1.6 cm

Contact Information

Applicant

Gerd Villing
[email protected]00497424991747Fax: 00497424992122

Technical Contact

SGS Korea Co., LtdInho Park
[email protected]82-31-688-0917

4, LS-ro, 182 beon-gil Β· Gunpo-si, Gyeonggi-do Β· South Korea

Non-Technical Contact

SGS Korea Co., LtdJimyoung Hong
[email protected]82-31-428-5702

Test Firm

SGS Korea Co., LtdHwang Gihee
[email protected]+82-31-688-0901Fax: +82-31-427-2370

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from Marquardt GmbH

IYZZK1

vehicle key

Jul 23, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
IYZZE1

ECU Electronic Control Unit

Jul 01, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
IYZOR1

NFC Reader for car access

Mar 05, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
IYZGK2A

Passive entry vehicle key

Dec 11, 2025

Equipment Class

DTS - Digital Transmission System
IYZ-NH3

NFC Door Handle Sensor

Dec 09, 2025

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter