Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
External photos NSS NSS_external_photos.docx Seite 1 von 4 form 102 de .0 7 External photos NSS NSS_external_photos.docx Seite 2 von 4 form 102 de .0 7 External photos NSS NSS_external_photos.docx Seite 3 von 4 form 102 de .0 7 External photos NSS NSS_external_photos.docx Seite 4 von 4 form 102 de .0 7 25.06.2020 KFM
Annex A 1-0017/20-01-01_AnnexA External photos of the Equipment Under Test This addendum is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Document authorized: Marco Bertolino Lab Manager Radio Communications & EMC CTC advanced GmbHUntertuerkheimer Str. 6-10 66117 Saarbruecken / Germany Phone: +49 681 5 98 - 0 Fax: +49 681 5 98 - 9075 web: ctcadvanced.com e-mail: [email protected] Photos Photo 1 Photo 2 2020-05-25Document No. 1-0017/20-01-01_AnnexA2/6 Photo 3 Photo 4 2020-05-25Document No. 1-0017/20-01-01_AnnexA3/6 Photo 5 Photo 6 2020-05-25Document No. 1-0017/20-01-01_AnnexA4/6 Photo 7 2020-05-25Document No. 1-0017/20-01-01_AnnexA5/6 Document history VersionApplied changesDate of release initial release2020-05-25 - END OF DOCUMENT - 2020-05-25Document No. 1-0017/20-01-01_AnnexA6/6
CONFIDENTIAL© This documentistheexclusivepropertyofMarquardt. Withoutourconsent, itmaynot bereproducedorgiventothirdparties. 1| M301508 NSS LABEL DRAWING G A U R I D-0 4 . 0 8 . 2 0 2 0 CONFIDENTIAL© This documentistheexclusivepropertyofMarquardt. Withoutourconsent, itmaynot bereproducedorgiventothirdparties. 2| N EUES CORPORATE D ESIG N0 4 .0 8 .2 0 2 0|
Internal photos NSS NSS_internal_photos.docx Seite 1 von 3 form 102 de .0 7 Internal photos NSS NSS_internal_photos.docx Seite 2 von 3 form 102 de .0 7 Internal photos NSS NSS_internal_photos.docx Seite 3 von 3 form 102 de .0 7 25.06.2020 KFM
Annex B 1-0017/20-01-01_AnnexB Internal photos of the Equipment Under Test This addendum is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Document authorized: Marco Bertolino Lab Manager Radio Communications & EMC CTC advanced GmbHUntertuerkheimer Str. 6-10 66117 Saarbruecken / Germany Phone: +49 681 5 98 - 0 Fax: +49 681 5 98 - 9075 web: ctcadvanced.com e-mail: [email protected] Photos Photo 1 Photo 2 2020-05-25Document No. 1-0017/20-01-01_AnnexB2/5 Photo 3 Photo 4 2020-05-25Document No. 1-0017/20-01-01_AnnexB3/5 Photo 5 Photo 6 2020-05-25Document No. 1-0017/20-01-01_AnnexB4/5 Document history VersionApplied changesDate of release initial release2020-05-25 - END OF DOCUMENT - 2020-05-25Document No. 1-0017/20-01-01_AnnexB5/5
TEST REPORT Test report no.: 1-0017/20-01-02-A Testing laboratory Applicant CTC advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.ctcadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2005) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate starting with the registration number: D-PL-12076-01. Marquardt GmbH Schloss-Str. 16 78604 Rietheim-Weilheim / GERMANY Phone: +49 7424 99-0 Contact: Mathias Kiefer e-mail: [email protected] Phone: +49 7424 99-28189 Manufacturer Marquardt Schaltsysteme S.C.S. Str. München Nr. 2 550018 Sibiu Zona Industriala Vest / ROMANIA Test standard/s FCC - Title 47 CFR Part 15 FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency devices RSS - 210 Issue 10 Spectrum Management and Telecommunications Radio Standards Specification - Licence-Exempt Radio Apparatus: Category I Equipment For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Emergency start transponder module Model name: NSS FCC ID: IYZNSS IC: 2701A-NSS Frequency: 125 kHz Technology tested: RFID Antenna: Integrated antenna Power supply: 12 V DC by external power supply Temperature range: -40°C to +85°C This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: Christoph Schneider Marco Bertolino Lab Manager Lab Manager Radio Communications Radio Communications Test report no.: 1-0017/20-01-02-A © CTC advanced GmbH Page 2 of 18 1 Table of contents 1 Table of contents ............................................................................................................................................. 2 2 General information ......................................................................................................................................... 3 2.1 Notes and disclaimer ............................................................................................................................ 3 2.2 Application details ................................................................................................................................ 3 2.3 Test laboratories sub-contracted ......................................................................................................... 3 3 Test standard/s, references and accreditations .............................................................................................. 4 4 Test environment ............................................................................................................................................. 5 5 Test item .......................................................................................................................................................... 5 5.1 General description ............................................................................................................................... 5 5.2 Additional information .......................................................................................................................... 5 6 Description of the test setup............................................................................................................................ 6 6.1 Shielded fully anechoic chamber .......................................................................................................... 7 6.2 Test setup for normalized measurement configurations ..................................................................... 8 7 Sequence of testing ......................................................................................................................................... 9 7.1 Sequence of testing radiated spurious 9 kHz to 30 MHz ..................................................................... 9 8 Measurement uncertainty .............................................................................................................................. 10 9 Summary of measurement results ................................................................................................................ 11 10 Additional comments ................................................................................................................................. 11 11 Measurement results.................................................................................................................................. 12 11.1 Occupied bandwidth ........................................................................................................................ 12 11.2 Field strength of the fundamental ................................................................................................... 14 11.3 Field strength of the harmonics and spurious ................................................................................ 15 12 Observations ............................................................................................................................................... 16 13 Glossary ...................................................................................................................................................... 17 14 Document history ....................................................................................................................................... 18 15 Accreditation Certificate – D-PL-12076-01-05 ......................................................................................... 18 Test report no.: 1-0017/20-01-02-A © CTC advanced GmbH Page 3 of 18 2 General information 2.1 Notes and di…
Text truncated - open the document above for the full version.
Annex C 1-0017/20-01-01_AnnexC Setup photos of the Equipment Under Test This addendum is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Document authorized: Marco Bertolino Lab Manager Radio Communications & EMC CTC advanced GmbHUntertuerkheimer Str. 6-10 66117 Saarbruecken / Germany Phone: +49 681 5 98 - 0 Fax: +49 681 5 98 - 9075 web: ctcadvanced.com e-mail: [email protected] Photos Photo 1 Photo 2 2020-05-25Document No. 1-0017/20-01-01_AnnexC2/6 Photo 3 Photo 4 2020-05-25Document No. 1-0017/20-01-01_AnnexC3/6 Photo 5 Photo 6 2020-05-25Document No. 1-0017/20-01-01_AnnexC4/6 Photo 7 Photo 8 2020-05-25Document No. 1-0017/20-01-01_AnnexC5/6 Document history VersionApplied changesDate of release initial release2020-05-25 - END OF DOCUMENT - 2020-05-25Document No. 1-0017/20-01-01_AnnexC6/6
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |
vehicle key
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterECU Electronic Control Unit
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterNFC Reader for car access
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterPassive entry vehicle key
Equipment Class
DTS - Digital Transmission SystemNFC Door Handle Sensor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter