DB7 - FHD Video Doorbell Features } Answer audio/video calls with speakerphone } View and listen at any time } Optional internal wireless chime module (DBC5) } Record events for up to 60 days on the cloud (with paid subscription) with 5 seconds pre-event } FHD video (1080x1920) resolution } HiFi audio with crisp and clear two-way communication } Day/Night mode with IR night illumination } Event trigger with PIR and/or video processing } Push notifications } WiFi connection } IP54 dust/water resistance } DB7 angle mount bracket (optional) } Theft protection plan Description Paradox DB7 Video Doorbell adds surveillance protection to home or business security. It integrates security with style into your daily life. With the DB7, you will get verification of every visitor to your property entrance. The DB7 allows you to see and clearly hear who is at your entrance 24/7, and Paradox servers will keep your visitors’ events up to 60 days (a monthly charge applies). The DB7 provides FHD video (1920x1080) and two-way communication speakerphone supported with 2.5W rms power and high quality speaker, delivering crisp conversations. The DB7 captures 5-second pre-event recordings, with exceptional video in dark conditions, complimented by night IR illumination. Push events can alert if anyone approaches even if they don’t ring the doorbell, with PIR and/or video detection. Integrated with Paradox systems, a door opening can be easily configured with a panel PGM or with Paradox access control. Video and audio data is encrypted with AES. The DB7 uses video H.264 data compression to save bandwidth. Adding internal wireless chime anywhere on the site is easy with the optional DBC5 wireless chime. BlueEye Application The newly designed Paradox BlueEye mobile app in conjunction with the Swan server, manages the alarm system, access, lights and garage doors, and also answer calls or connect anytime to the DB7 to view, listen, and talk when desired. Swan service keeps the history of recordings for 60 days when subscribed to recording services. History files can be viewed, downloaded, and protected from editing while in Paradox video format. The BlueEye application is used to configure easily and customize the DB7. Video Encryption DB7 videos are encrypted with 256 byte TLS encryption. Paradox can not decrypt the videos stored on our recording servers, only permitted users can choose to decrypt and share video files from the application. Safe, secure and private. One Application Security, Video Doorbell, Access, Outputs, and more. Loud and crisp audio. Finally, talking and understanding. Resolution1920 x 1080 Inverted Full HD, H.264, 15 FPS Night VisionInfrared, 10 FPS, IR Filter when active, Anti-Glare detection AudioHD, Class D amplifier 2.5W RMS Power Connection 12-24 AC, DC 500 mA / 7.5W minimum (Supply connection is NOT supporting bells in series) Detection TypeImage recognition and/or PIR detection Pre-event Recording5 seconds before event Field of View155° Vertical, 94° Horizontal WiFi2.4 GHz, supports 802.11b/g/n BatteryRechargeable Lithium-ion up to 10 hours in normal use TamperWall Operating Temperature-20 to 45 °C (-4 to 113 °F) Operating Humidity80% Dimensions (H x W x D)16 x 6.5 x 3.5 cm (6.3 x 2.5 x 1.5 in.) Weight180g (6.3 oz) Color OptionsKohinor white and Stevio black CertificationsCE, FCC, IP54 Installation Requirements Paradox panel produced on or after 2017 with IP150, IP150+, or PCS265LTE. All latest FW. Power (two wires), WiFi 2.4 GHz Internal Chime (optional) DBC5, 433 MHz, 1 per doorbell, up to 100 ft, 8 chime sounds Cloud Recording (subscription) Unlimited event recordings/storage for 60 days, for all calls (2.5 minutes file length), movement detection up to 30 sec. and Cooldown 30 sec. All videos include 5 sec. pre-event. Subscription activation needed via application. Theft/vandalize Insurance (subscription) Insurance purchase available upon registration via BlueEye mobile application. Conditions apply. Warranty2 years, see full warranty conditions on paradox.com/terms Technical Specifications Accesories The installation works with existing doorbell wires, but does NOT support bell in series, wide supply range of 12-24 Vac or DC and 500 mA / 7.5W minimum. Connects via WiFi. Internal wireless chime can be added easily with the DBC5 accessory. The DB7 is an outdoor device; in case of theft, or if vandalized, Paradox offers an insurance program. When enrolled, the DB7 is replaced once a year, no questions asked, and two times more per year at $50 cost. All stolen/ damaged DB7’s will be blacklisted and can’t be used anymore. DB7 angle mount bracket DB7 view cam DBC5 www.paradox.com TDB7-G2K rev.06 - Printed in Canada 12/2022. Specifications may change without prior notice. International patents may apply. Paradox is a trademark or registered trademark of Paradox Security Systems (Bahamas) Ltd. FCC and Industry Canada Compliance Statement This device complies with FCC Rules Part 15 and with Industry Canada license exempt RSS standard(s). Operation is subject to two conditions: • This device may not cause harmful interference. • This device must accept any interference that may be received or that may cause undesired operation. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : • L’appareil ne doit pas produire de brouillage. • L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. FCC ID: KDYDB7 IC: 2438A-DB7 FCC NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful int…
Text truncated - open the document above for the full version.
Page 1 of 1 November 29, 2022 Telefication B.V. Attn: Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Application for certification of a Video Doorbell, DB7, FCC ID: KDYDB7 Dear Gentlemen, Please find attached our application for certification of the Video Doorbell, brand name DB7, FCC ID: KDYDB7, prepared in accordance with FCC Rules part 15 subpart C section 15.231. The product testing and this application for certification were performed by Hermon Laboratories, which is recognized and accredited by FCC, Test Firm Registration Number is 927748, Designation Number is IL1001. Hermon Labs responsible person is Mr. Michael Nikishin, tel: +972 4626 8440, fax:+972 4628 8277, e-mail: [email protected]. Please send an invoice to Hermon Labs. We hope this application satisfies your requirements Sincerely yours, Alex Chaplik, Certification Manager
RF_160, Issue 04 Declaration of Authorization We Name: Paradox Security Systems Ltd. Address: 780 Industriel Blvd . City: Saint-Eustache, Quebec J7R 5V3. Country: Canada . Declare that: Name Representative of agent: ............. (1) Agent Company name: Hermon Laboratories Ltd.. Address: Harakevet Industrial Zone .. City: Binyamina 30500.. Country Israel . is authorized to apply for Certification of the following product(s): Product description: Video Doorbell Type designation: DB7 . Trademark: Paradox. Validity/ expiry date: November 29, 2023 on our behalf. Date: November 29, 2022 City: Saint-Eustache .. Name: Alex Chaplik .. (2) Function: Certification manager ............................... Signature: . Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.
FCC, Request for non-disclosure Date: 21-Nov-2018 RF_501, Issue 8 Page 1 of 1 Company Name: Paradox Security Systems Address: 780 Industriel Blvd City: Saint-Eustache, QC, J7R 5V3 Country: Canada To: Telefication B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: KDYDB7 Reference number: 48750 Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Patent pending, Competative advantage Date: November 29, 2022 Name and signature of applicant: Alex Chaplik Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should stated in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period
Paradox Security Systems Ltd. FCC ID: KDYDB7 IC: 2438A-DB7 Page 1 of 3 EXTERNAL PHOTOGRAPHS This document contains 2 photographs Paradox Security Systems Ltd. FCC ID: KDYDB7 IC: 2438A-DB7 Page 2 of 3 Photograph No.1 Front view Paradox Security Systems Ltd. FCC ID: KDYDB7 IC: 2438A-DB7 Page 3 of 3 Photograph No.2 Rear view
Paradox Security Systems Ltd. FCC ID: KDYDB7 IC:2438A-DBY Page 1 of 1 Label The label shown below is affixed on the rear side of the detector. The label material is PVC with a permanent adhesive. Label location Label with FCC ID:KDYDB7 and IC:2438A-DB7 will be located here. The statement according to FCC part 15 §15.19(a)(3) is placed in User Manual, page 4 (Application exhibit User_manual_48750).
Paradox Security Systems Ltd. FCC ID: KDYDB7 IC: 2438A-DB7 Page 1 of 5 INTERNAL PHOTOGRAPHS This document contains 4 photographs Paradox Security Systems Ltd. FCC ID: KDYDB7 IC: 2438A-DB7 Page 2 of 5 Photograph No.1 Internal view Paradox Security Systems Ltd. FCC ID: KDYDB7 IC: 2438A-DB7 Page 3 of 5 Photograph No.2 Print side of the main PCB Paradox Security Systems Ltd. FCC ID: KDYDB7 IC: 2438A-DB7 Page 4 of 5 Photograph No.3 Camera Module Paradox Security Systems Ltd. FCC ID: KDYDB7 IC: 2438A-DB7 Page 5 of 5 Photograph No.4 Antenna assembly
Video Doorbell DB7 – Antenna Specification (photographs, length of wire antenna) • Total Length of 433MHz Antenna of DB7 is 15.7 ± 0.5 cm • First 2 photos show the configuration of antenna in EUT DB7. • Photos #3 and #4 show soldering of Antenna on pcb of DB7. Photograph No.1 Photograph No.2 Photograph No.3 Photograph No.4
Hermon Laboratories Ltd. P.O. Box 23, Binyamina 3055001, Israel Tel. +972 4628 8001 Fax. +972 4628 8277 E-mail: [email protected] Page 1 of 43 Report ID: PARRAD_FCC.48750.docx Date of Issue: 28-Nov-22 ELECTRICAL TESTING 0839.01 TEST REPORT ACCORDING TO: FCC CFR 47 Part 15 subpart C, section 15.231 and subpart B, RSS-210 issue 10 Annex A, RSS-Gen issue 5, ICES-003 Issue 7:2020 FOR: Paradox Security Systems Ltd. Video Doorbell Model: DB7 FCC ID: KDYDB7 IC: 2438A-DB7 This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Report ID: PARRAD_FCC.48750.docx Date of Issue: 28-Nov-22 Page 2 of 43 Table of contents 1 Applicant information ..................................................................................................................................................... 3 2 Equipment under test attributes .................................................................................................................................... 3 3 Manufacturer information .............................................................................................................................................. 3 4 Test details .................................................................................................................................................................... 3 5 Tests summary .............................................................................................................................................................. 4 6 EUT description ............................................................................................................................................................. 5 6.1 General information ....................................................................................................................................................... 5 6.2 Test configuration .......................................................................................................................................................... 5 6.3 Changes made in EUT .................................................................................................................................................. 5 6.4 Transmitter characteristics ............................................................................................................................................ 6 7 Transmitter tests according to 47CFR part 15 subpart C requirements ........................................................................ 7 7.1 Periodic operation requirements ................................................................................................................................... 7 7.2 Field strength of emissions ............................................................................................................................................ 9 7.3 Occupied bandwidth test ............................................................................................................................................. 21 7.4 Conducted emissions .................................................................................................................................................. 23 7.5 Antenna requirements ................................................................................................................................................. 27 8 Unintentional emissions according to 47CFR part 15 subpart B and ICES-003 requirements .................................... 28 8.1 Conducted emissions .................................................................................................................................................. 28 8.2 Radiated emission measurements .............................................................................................................................. 32 9 APPENDIX A Test equipment and ancillaries used for tests ....................................................................................... 36 10 APPENDIX B Test equipment correction factors ......................................................................................................... 37 11 APPENDIX C Measurement uncertainties .................................................................................................................. 39 12 APPENDIX D Test laboratory description ................................................................................................................... 40 13 APPENDIX E Specification references........................................................................................................................ 41 14 APPENDIX F Abbreviations and acronyms ................................................................................................................. 42 15 APPENDIX G Manufacturer’s declaration about periodic operation ............................................................................ 43 Report ID: PARRAD_FCC.48750.docx Date of Issue: 28-Nov-22 Page 3 of 43 1 Applicant information Client name: Paradox Security Systems Ltd. Address: 780 Industrial Boulevard St.Eustache, Quebec J7R 5V3 Canada Telephone: 450-491-7444 Fax: 450-497-1095 E-mail: [email protected] Contact name: Mr. Alex Chaplik 2 Equipment under test attributes Product name: Video doorbell Product type: Transceiver Model(s): DB7 Serial number: YSYN9F Hardware version: 428-5001-997 Software release: V1.00 Receipt date 24-Oct-22 3 Manufacturer information Manufacturer name: Paradox Security Systems Ltd. Address: 780 Industrial Boulevard St.Eustache, Quebec J7R 5V3 Canada Telephone: 450-491-7444 Fax: 450-497-1095 E-Mail: [email protected] Contact name: …
Text truncated - open the document above for the full version.
Paradox Security Systems Ltd. FCC ID: KDYDB7 IC: 2438A-DB7 Page 1 of 5 SETUP PHOTOGRAPHS This document contains 4 photographs Paradox Security Systems Ltd. FCC ID: KDYDB7 IC: 2438A-DB7 Page 2 of 5 Photograph No.1 Setup for spurious emission field strength measurements in the anechoic chamber below 30 MHz Paradox Security Systems Ltd. FCC ID: KDYDB7 IC: 2438A-DB7 Page 3 of 5 Photograph No.2 Setup for carrier field strength, spurious emission field strength measurements in the anechoic chamber in 30 – 1000 MHz range Paradox Security Systems Ltd. FCC ID: KDYDB7 IC: 2438A-DB7 Page 4 of 5 Photograph No.3 Setup for carrier field strength, spurious emission field strength measurements in the anechoic chamber above 1000 MHz Paradox Security Systems Ltd. FCC ID: KDYDB7 IC: 2438A-DB7 Page 5 of 5 Photograph No.4 Setup for OBW measurements
Harakevet Industrial zone, P.O.Box 23 · Israel
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |
Hybrid Head Unit/Console
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterDual Input /Output Wireless Bus Expander Two Garage Door
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter7 inch Touchscreen Keypad
Equipment Class
DTS - Digital Transmission SystemDoor /Window Magnetic Contact + Zone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
PGM Expander
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter