KDYMG5075Wireless control panel board

Paradox Security Systems
Wireless control panel board - FCC ID KDYMG5075 - Paradox Security Systems
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Aug 25, 2020
Application Purpose
Original Equipment
Date of Application
Aug 24, 2020
Equipment Note
Wireless control panel board
Frequency Range
433.92000000 - 433.92000000
Company
Paradox Security Systems
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

. MGSP Installation Guide Always Armed, Never Disarmed SP5500, SP6000 & SP7000 v7.14 SP4000 v5.23 SP65 v5.24 MG5075 v1.01 MG5050 & MG5000 v4.90 MG5050E v7.14 32-Zone Wireless Security Systems 4 to 32-Zone Expandable Security Systems Table of Contents Introduction ............................................................................ 5 Features ................................................................................................................................ 5 MG5075 Additional Features ........................................................................................ 5 System Overview ...............................................................................................................5 Modules Current Consumption List .......................................................................... 5 Specifications ...................................................................................................................... 6 Installation .............................................................................. 7 Location and Mounting .................................................................................................. 7 EN 50131 Compliancy ...................................................................................................... 7 Earth Ground ...................................................................................................................... 7 AC Power .............................................................................................................................. 7 Backup Battery ................................................................................................................... 7 MG5000 PCB Layout ......................................................................................................... 8 MG5050 / MG5050 EN PCB Layout .............................................................................. 9 MG5075 PCB Layout .......................................................................................................10 SP4000 PCB Layout .........................................................................................................11 SP5500 PCB Layout .........................................................................................................12 SP6000 PCB Layout .........................................................................................................13 SP7000 PCB Layout .........................................................................................................14 PCB Metal Box Installation ...........................................................................................15 Plastic Box Installation ...................................................................................................15 Auxiliary Power Terminals ............................................................................................17 Telephone Line Connection ........................................................................................17 Alarm Transmissions ......................................................................................................17 Bell Output Connection ................................................................................................17 Programmable Output Connections .......................................................................17 Single Zone Inputs ..........................................................................................................18 Advanced Technology Zone (ATZ) Connections .................................................19 Fire Circuits ........................................................................................................................20 Programming Methods ........................................................ 21 BabyWare Software for Windows ..............................................................................21 Programming Using a Keypad ...................................................................................21 Configuring the Keypad Zone Number ..................................................................22 Programming Using A Paradox Memory Key* .....................................................22 LCD Keypad Labels ............................................................... 23 Input Keys ..........................................................................................................................23 Label Sections ...................................................................................................................23 Special Characters and Keypad Letter Assignment ............................................23 Access Codes ......................................................................... 26 Access Code Length .......................................................................................................26 Installer Code (Default: 0000 / 000000) ...................................................................26 Maintenance Code (Default: Empty) ........................................................................26 System Master Code (Default: 1234 / 123456) .....................................................26 User Code Options ..........................................................................................................26 Lock Master Code ............................................................................................................27 StayD Mode ........................................................................... 28 Overview ............................................................................................................................28 Entry/Exit Paths ................................................................................................................28 Entry/Exit with a Keypad ........................................................................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

RF_160, Issue 04 Declaration of Authorization We Name: Paradox Security Systems Ltd. Address: 780 Industriel Blvd . City: Saint-Eustache, Quebec J7R 5V3. Country: Canada . Declare that: Name Representative of agent: ............. (1) Agent Company name: Hermon Laboratories Ltd.. Address: Harakevet Industrial Zone .. City: Binyamina 30500.. Country Israel . is authorized to apply for Certification of the following product(s): Product description: Wireless control panel board Type designation: MG5075. Trademark: Paradox. Validity/ expiry date: August 17, 2021 on our behalf. Date: August 17, 2020 City: Saint-Eustache .. Name: Alex Chaplik .. (2) Function: Certification manager ............................... Signature: . Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

FCC, Request for non-disclosure Date: 19-Oct-10 RF_501, Issue 7 Page 1 of 1 Company Name: Paradox Security Systems Address: 780 Industriel Blvd City: Saint-Eustache, QC, J7R 5V3 Country: Canada To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: KDYMG5075 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (note 1): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Patent pending, Competative advantage Planned Release Date STC: 180 days from the grant date (notes 2, 3, 4, 5). If no date is given, 45 days from grant date will be used. Date: August 17, 2020 Name and signature of applicant: Alex Chaplik Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period

External Photos

Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG5075 Page 1 of 3 EXTERNAL PHOTOGRAPHS This document contains 2 photographs Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG5075 Page 2 of 3 Photograph No.1 Wireless control panel board front view Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG5075 Page 3 of 3 Photograph No.2 Wireless control panel board rear side view

ID Label/Location Info

Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG5075 Page 1 of 1 Label The label shown below is affixed on the internal side of the control panel. The label material is PVC with a permanent adhesive. Label location Label with FCC ID:KDYMG5075 and IC:2438A-MG5075 will be located here. The statement according to FCC part 15 §15.19(a)(3) is placed in User Manual, page 4 (Application exhibit User_manual_34150).

Internal Photos

Paradox Security Systems Ltd. FCC ID: KDYM G5075 IC:2438A-MG5075 Page 1 of 6 INTERNAL PHOTOGRAPHS This document contains 5 photographs Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG5075 Page 2 of 6 Photograph No.1 Wireless control panel board internal view Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG5075 Page 3 of 6 Photograph No.2 PCB front view Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG50 75 Page 4 of 6 Photograph No.3 PCB second side view Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG5075 Page 5 of 6 Photograph No.4 PCB close view Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG5075 Page 6 of 6 Photograph No.5 Antenna close view

Test Report

Hermon Laboratories Ltd. P.O. Box 23, Binyamina 3055001, Israel Tel. +972 4628 8001 Fax. +972 4628 8277 E-mail: [email protected] Page 1 of 46 Report ID: PARRAD_FCC.34150 Date of Issue: 23-Aug-20 ELECTRICAL TESTING 0839.01 TEST REPORT ACCORDING TO: FCC CFR 47 Part 15 subpart C, section 15.231 and subpart B, RSS-210 issue 10 Annex A, RSS-Gen issue 5, ICES-003 Issue 6:2016 FOR: Paradox Security Systems Ltd. Wireless control panel board Product name: MG5075 FCC ID: KDYMG5075 IC: 2438A-MG5075 This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Report ID: PARRAD_FCC.34150 Date of Issue: 23-Aug-20 Page 2 of 46 Table of contents 1 Applicant information .............................................................................................................................................. 3 2 Equipment under test attributes............................................................................................................................... 3 3 Manufacturer information ........................................................................................................................................ 3 4 Test details ............................................................................................................................................................ 3 5 Tests summary ....................................................................................................................................................... 4 6 EUT description ...................................................................................................................................................... 5 6.1 General information ................................................................................................................................................ 5 6.2 Ports and lines ....................................................................................................................................................... 5 6.3 Changes made in EUT ........................................................................................................................................... 5 6.4 Test configuration ................................................................................................................................................... 6 6.5 Transmitter characteristics ...................................................................................................................................... 7 7 Transmitter tests according to 47CFR part 15 subpart C and RSS-210 requirements ................................................ 8 7.1 Periodic operation requirements .............................................................................................................................. 8 7.2 Field strength of emissions ................................................................................................................................... 11 7.3 Occupied bandwidth test....................................................................................................................................... 25 7.4 Conducted emissions ........................................................................................................................................... 28 7.5 Antenna requirements .......................................................................................................................................... 31 8 Unintentional emissions according to 47CFR part 15 subpart B and ICES-003 requirements .................................. 32 8.1 Conducted emissions ........................................................................................................................................... 32 8.2 Radiated emission measurements ........................................................................................................................ 35 9 APPENDIX A Test equipment and ancillaries used for tests ................................................................................... 39 10 APPENDIX B Test equipment correction factors .................................................................................................... 40 11 APPENDIX C Measurement uncertainties ............................................................................................................. 43 12 APPENDIX D Test laboratory description .............................................................................................................. 44 13 APPENDIX E Specification references .................................................................................................................. 44 14 APPENDIX G Manufacturer’s declaration about periodic operation ........................................................................ 45 15 APPENDIX F Abbreviations and acronyms ............................................................................................................ 46 Report ID: PARRAD_FCC.34150 Date of Issue: 23-Aug-20 Page 3 of 46 1 Applicant information Client name: Paradox Security Systems Ltd. Address: 780 Industrial Boulevard St.Eustache, Quebec J7R 5V3 Canada Telephone: 450-491-7444 Fax: 450-497-1095 E-mail: [email protected] Contact name: Mr. Alex Chaplik 2 Equipment under test attributes Product description: Wireless control panel board Product type: Transceiver Product name: MG5075 Serial number: E2000431 Hardware version: 910-2002-160 Software release: V1.03 Receipt date 31-Jun-20 3 Manufacturer information Manufacturer name: Paradox Security Systems (Bahamas) Ltd Address: 780 Industrial Boulevard St.Eustache, Quebec J7R 5V3 Canada Telephone: 450-4…

Text truncated - open the document above for the full version.

Test Setup Photos

Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG5075 Page 1 of 6 SETUP PHOTOGRAPHS This document contains 5 photographs Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG5075 Page 2 of 6 Photograph No.1 Setup for spurious emission field strength measurements in the anechoic chamber below 30 MHz Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG5075 Page 3 of 6 Photograph No.2 Setup for carrier field strength, spurious emission field strength measurements in the anechoic chamber in 30 – 1000 MHz range Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG5075 Page 4 of 6 Photograph No.3 Setup for spurious emission field strength measurements in the anechoic chamber above 1000 MHz Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG5075 Page 5 of 6 Photograph No.4 Setup for periodic operation measurements Paradox Security Systems Ltd. FCC ID: KDYMG5075 IC:2438A-MG5075 Page 6 of 6 Photograph No.5 Setup for OBW measurements

Contact Information

Applicant

Alex Chaplik(Certification Manager)
[email protected]450-491-7444Fax: 450-491-2313

Technical Contact

Hermon Laboratories Ltd.Michael Nikishin
[email protected]972 4626 8440

Harakevet Industrial zone, P.O.Box 23 · Israel

Non-Technical Contact

Paradox Security Systems Ltd.Alex Chaplik
[email protected]972 4850 0499

Test Firm

Hermon Laboratories Ltd.George Shleimovich
[email protected]97246268468Fax: +972 4 626 8469

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Paradox Security Systems

KDYX45

Hybrid Head Unit/Console

May 07, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
KDYZP2M

Dual Input /Output Wireless Bus Expander Two Garage Door

Dec 23, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
KDYK70M

7 inch Touchscreen Keypad

Dec 12, 2025

Equipment Class

DTS - Digital Transmission System
KDYDCT12M

Door /Window Magnetic Contact + Zone

Nov 25, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
PGM Expander - FCC ID KDYPGM8M - Paradox Security Systems Ltd
KDYPGM8M

PGM Expander

Nov 25, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter