Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RF_160, Issue 04 Declaration of Authorization We Name: Paradox Security Systems Ltd. Address: 780 Industriel Blvd . City: Saint-Eustache, Quebec J7R 5V3. Country: Canada . Declare that: Name Representative of agent: ............. (1) Agent Company name: Hermon Laboratories Ltd.. Address: Harakevet Industrial Zone .. City: Binyamina 30500.. Country Israel . is authorized to apply for Certification of the following product(s): Product description: Wireless PIR Motion Detector Type designation: PMD75N . Trademark: Paradox. Validity/ expiry date: July 06, 2022 on our behalf. Date: July 06, 2021 City: Saint-Eustache .. Name: Alex Chaplik .. (2) Function: Certification manager ............................... Signature: Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.
FCC, Request for non-disclosure Date: 19-Oct-10 RF_501, Issue 7 Page 1 of 1 Company Name: Paradox Security Systems Address: 780 Industriel Blvd City: Saint-Eustache, QC, J7R 5V3 Country: Canada To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: KDYPMD75N Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (note 1): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Patent pending, Competative advantage Planned Release Date STC: 180 days from the grant date (notes 2, 3, 4, 5). If no date is given, 45 days from grant date will be used. Date: July 07, 2021 Name and signature of applicant: Alex Chaplik Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period
Paradox Security Systems Ltd. FCC ID: KDYPMD75N IC: 2438A-PMD75N Page 1 of 3 EXTERNAL PHOTOGRAPHS This document contains 2 photographs Paradox Security Systems Ltd. FCC ID: KDYPMD75N IC: 2438A-PMD75N Page 2 of 3 Photograph No.1 Front view Paradox Security Systems Ltd. FCC ID: KDYPMD75N IC: 2438A-PMD75N Page 3 of 3 Photograph No.2 Rear view
Paradox Security Systems Ltd. FCC ID: KDYPMD75N IC:2438A-PMD75N Page 1 of 2 Label The label shown below is affixed on the rear side of the detector. The label material is PVC with a permanent adhesive. Paradox Security Systems Ltd. FCC ID: KDYPMD75N IC:2438A-PMD75N Page 2 of 2 Label location Label with FCC ID:KDYPMD75N and IC:2438A-PMD75N will be located here. The statement according to FCC part 15 §15.19(a)(3) is placed in User Manual, page 2 (Application exhibit User_manual_42332).
Paradox Security Systems Ltd. FCC ID: KDYPMD75N IC: 2438A-PMD75N Page 1 of 4 INTERNAL PHOTOGRAPHS This document contains 3 photographs Paradox Security Systems Ltd. FCC ID: KDYPMD75N IC: 2438A-PMD75N Page 2 of 4 Photograph No.1 Internal view Paradox Security Systems Ltd. FCC ID: KDYPMD75N IC: 2438A-PMD75N Page 3 of 4 Photograph No.2 Print side of the main PCB Paradox Security Systems Ltd. FCC ID: KDYPMD75N IC: 2438A-PMD75N Page 4 of 4 Photograph No.3 Antenna assembly
Hermon Laboratories Ltd. P.O. Box 23, Binyamina 3055001, Israel Tel. +972 4628 8001 Fax. +972 4628 8277 E-mail: [email protected] Page 1 of 36 Report ID: PARRAD_FCC.42332 Date of Issue: 27-Jul-21 ELECTRICAL TESTING 0839.01 TEST REPORT ACCORDING TO: FCC CFR 47 Part 15 subpart C, section 15.231 and subpart B, RSS-210 issue 10 Annex A, RSS-Gen issue 5, ICES-003 Issue 6:2016 FOR: Paradox Security Systems Ltd. Wireless PIR Motion Detector Model: PMD75N FCC ID: KDYPMD75N IC: 2438A-PMD75N This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Report ID: PARRAD_FCC.42332 Date of Issue: 27-Jul-21 Page 2 of 36 Table of contents 1 Applicant information ..................................................................................................................................................... 3 2 Equipment under test attributes .................................................................................................................................... 3 3 Manufacturer information .............................................................................................................................................. 3 4 Test details .................................................................................................................................................................... 3 5 Tests summary .............................................................................................................................................................. 4 6 EUT description ............................................................................................................................................................. 5 6.1 General information ....................................................................................................................................................... 5 6.2 Test configuration .......................................................................................................................................................... 5 6.3 Changes made in EUT .................................................................................................................................................. 5 6.4 Transmitter characteristics ............................................................................................................................................ 6 7 Transmitter tests according to 47CFR part 15 subpart C and RSS-210 requirements .................................................. 7 7.1 Periodic operation requirements ................................................................................................................................... 7 7.2 Field strength of emissions .......................................................................................................................................... 11 7.3 Occupied bandwidth test ............................................................................................................................................. 21 7.4 Antenna requirements ................................................................................................................................................. 24 8 Unintentional emissions according to 47CFR part 15 subpart B and ICES-003 requirements .................................... 25 8.1 Radiated emission measurements .............................................................................................................................. 25 9 APPENDIX A Test equipment and ancillaries used for tests ....................................................................................... 29 10 APPENDIX B Test equipment correction factors ......................................................................................................... 30 11 APPENDIX C Measurement uncertainties .................................................................................................................. 33 12 APPENDIX D Test laboratory description ................................................................................................................... 34 13 APPENDIX E Specification references........................................................................................................................ 34 14 APPENDIX F Manufacturer’s declaration about periodic operation ............................................................................ 35 15 APPENDIX G Abbreviations and acronyms ................................................................................................................ 36 Report ID: PARRAD_FCC.42332 Date of Issue: 27-Jul-21 Page 3 of 36 1 Applicant information Client name: Paradox Security Systems Ltd. Address: 780 Industrial Boulevard St.Eustache, Quebec J7R 5V3 Canada Telephone: 450-491-7444 Fax: 450-497-1095 E-mail: [email protected] Contact name: Mr. Alex Chaplik 2 Equipment under test attributes Product name: Wireless PIR Motion Detector Product type: Transmitter Model(s): PMD75N Serial number: 034173 Hardware version: 304-7007-070 Software release: V1.00 Receipt date 14-Mar-21 3 Manufacturer information Manufacturer name: Paradox Security Systems Ltd. Address: 780 Industrial Boulevard St.Eustache, Quebec J7R 5V3 Canada Telephone: 450-491-7444 Fax: 450-497-1095 E-Mail: [email protected] Contact name: Mr. Alex Chaplik 4 Test details Project ID: 42332 Location: Hermon Laboratories Ltd. P.O. Box 23, Binyamina 3055001, Israel Test started: 08-Jun-21 Test completed: 27-Jun-21 Test specification(s): FCC 47CFR part 15, subpart C, §15.231 and subpart B; RSS-210 issue 10 Annex A, RSS-Gen issue 5, ICES-003 Issue 6:2016 Report ID: PARRAD_FC…
Text truncated - open the document above for the full version.
Paradox Security Systems Ltd. FCC ID: KDYPMD75N IC: 2438A-PMD75N Page 1 of 5 SETUP PHOTOGRAPHS This document contains 4 photographs Paradox Security Systems Ltd. FCC ID: KDYPMD75N IC: 2438A-PMD75N Page 2 of 5 Photograph No.1 Setup for spurious emission field strength measurements in the anechoic chamber below 30 MHz Paradox Security Systems Ltd. FCC ID: KDYPMD75N IC: 2438A-PMD75N Page 3 of 5 Photograph No.2 Setup for carrier field strength, spurious emission field strength measurements in the anechoic chamber in 30 – 1000 MHz range Paradox Security Systems Ltd. FCC ID: KDYPMD75N IC: 2438A-PMD75N Page 4 of 5 Photograph No.3 Setup for carrier field strength, spurious emission field strength measurements in the anechoic chamber above 1000 MHz Paradox Security Systems Ltd. FCC ID: KDYPMD75N IC: 2438A-PMD75N Page 5 of 5 Photograph No.4 Setup for OBW measurements
Harakevet Industrial zone, P.O.Box 23 Binyamina · Israel
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |
Hybrid Head Unit/Console
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterDual Input /Output Wireless Bus Expander Two Garage Door
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter7 inch Touchscreen Keypad
Equipment Class
DTS - Digital Transmission SystemDoor /Window Magnetic Contact + Zone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
PGM Expander
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter