Basic Remote Trainer operating and training guide Model Number PDT00-13882 Please reaD This eNTire guiDe before begiNNiNg 2 Customer Care Center 1-800-732-2677 Important Safety Information Explanation of Attention Words and Symbols used in this guide This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. CAUTION, used without the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in harm to your pet. Risk of explosion. Do not short circuit, mix old and new batteries, dispose of in fire, or expose to water. When batteries are stored or disposed, they must be protected from shorting. Dispose of used batteries properly. Not for use with aggressive dogs. Do not use this Product if your dog is aggressive, or if your dog is prone to aggressive behavior. Aggressive dogs can cause severe injury and even death to their owner and others. If you are unsure whether this product is appropriate for your dog, please consult your veterinarian or certified trainer. Safety during on-leash training. It is vitally important that you and your dog remain safe while learning during on-leash training. Your dog should be on a strong leash, long enough for him to attempt to chase an object, but short enough for him not to reach a road or other unsafe area. You must also be physically strong enough to restrain your dog when he tries to chase. Risk of skin damage. Please read and follow the instructions in this manual. Proper fit of the collar is important. A collar worn for too long or made too tight on the pet’s neck may cause skin damage. Ranging from redness to pressure ulcers; this condition is commonly known as bed sores. : Avoid leaving the collar on the dog for more than 12 hours per day. : When possible reposition the collar on the pet’s neck every 1 to 2 hours. : Check the fit to prevent excessive pressure; follow the instructions in this manual. : Never connect a lead to the electronic collar; it will cause excessive pressure on the contacts. : When using a separate collar for a lead, don’t put pressure on the electronic collar. : Wash the dog’s neck area and the contacts of the collar weekly with a damp cloth. : Examine the contact area daily for signs of a rash or a sore. : If a rash or sore is found, discontinue use of the collar until the skin has healed. www.petsafe.net 3 : If the condition persists beyond 48 hours, see your veterinarian. : For additional information on bed sores and pressure necrosis, please visit our website. These steps will help keep your pet safe and comfortable. Millions of pets are comfortable while they wear stainless steel contacts. Some pets are sensitive to contact pressure. You may find after some time that your pet is very tolerant of the collar. If so, you may relax some of these precautions. It is important to continue daily checks of the contact area. If redness or sores are found, discontinue use until the skin has fully healed. PetSafe ® Remote Trainers must be used only on healthy dogs. We recommend that you take your dog to a veterinarian before using the collar if he is not in good health. 4 Customer Care Center 1-800-732-2677 Thank you for choosing the PetSafe ® brand. You and your pet deserve a companionship that includes memorable moments and a shared understanding together. Our products and training tools promote a lifestyle of protection, teaching, and love—essentials that influence memories for a lifetime. If you have any questions about our products or training your pet, please visit our website at www.petsafe.net or contact our Customer Care Center at 1-800-732-2677. To get the most protection out of your warranty, please register your product within 30 days at www.petsafe.net. By registering and keeping your receipt, you will enjoy the product’s full warranty and should you ever need to call the Customer Care Center, we will be able to help you faster. Most importantly, PetSafe ® will never give or sell your valuable information to anyone. Complete warranty information is available online at www.petsafe.net. Table of Contents Components ............................................................................................................................5 Other Items You May Need .....................................................................................................5 How the System Works ...........................................................................................................5 Features ...................................................................................................................................6 Key Definitions ........................................................................................................................6 Operating Guide ....................................................................................................................8 Prepare the Remote Transmitter ..........................................................................................8 Prepare the Receiver Collar .................................................................................................9 Fit the Receiver Collar........................................................................................................10 To Pair the Receiver Collar and the Remote Transmitter ..................................................11 Training Guide ......................................................................................................................12 General Tips ................................................................................................................…
Text truncated - open the document above for the full version.
10427 PetSafe Way Knoxville, TN. 37932 865-777-5404 www.petsafe.net Date: November 28, 2012 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: KE3-3001132 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Schematics SCH.pdf Block Diagram BlockDiagram.pdf Circuit Description OperationDescription.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Radio Systems Corporation .................................................................. [signature] Cindy Allen/Product Safety and Regulatory Specialist .................................................................. [typed name and title]
10427 PetSafe Way Knoxville, TN. 37932 865-777-5404 www.petsafe.net FCC ID: KE3-3001132 POWER OF ATTORNEY November 28, 2012 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf shall have the same effect as acts of our own. This authorization expires on October 22,2013 This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, Radio Systems Corporation, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Radio Systems Corporation .................................................................................... [signature] Cindy Allen/Product Safety and Regulatory Specialist .................................................................................... [typed name and title]
Reference No.: WT12117325-S-S-F Page 17 of 23 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 9 Photographs - Constructional Details 9.1 EUT –Appearance View Reference No.: WT12117325-S-S-F Page 18 of 23 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WT12117325-S-S-F Page 19 of 23 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WT12117325-S-S-F Page 20 of 23 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn
FCC Label Location for model: RFA-486 The Label must not be a stick-on paper. The Label on these products must be permanently affixed to the product and readily visible at the time of purchase and must last the expected lifetime of the equipment not be readily detachable. Proposed Label Location on EUT EUT Bottom View/proposed FCC Label Location FCC ID: KE3-3001132 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Label Location for model: RFA-488 The Label must not be a stick-on paper. The Label on these products must be permanently affixed to the product and readily visible at the time of purchase and must last the expected lifetime of the equipment not be readily detachable. Proposed Label Location on EUT EUT Bottom View/proposed FCC Label Location FCC ID: KE3-3001132 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Label Location for model: RFA-505 The Label must not be a stick-on paper. The Label on these products must be permanently affixed to the product and readily visible at the time of purchase and must last the expected lifetime of the equipment not be readily detachable. Proposed Label Location on EUT EUT Bottom View/proposed FCC Label Location FCC ID: KE3-3001132 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Label Sample for model: RFA-486 FCC ID: KE3-3001132 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)this device may not cause harmful interference,and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Label Sample for model: RFA-488 FCC ID: KE3-3001132 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)this device may not cause harmful interference,and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Label Sample for model: RFA-505 FCC ID: KE3-3001132 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)this device may not cause harmful interference,and (2) this device must accept any interference received, including interference that may cause undesired operation.
PCB – Front View PCB – Back View
Reference No.: WT12117325-S-S-F Page 1 of 23 FCC TEST REPORT Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn FCC ID : KE3-3001132 Applicant : Radio Systems Corporation Address : 10427 Petsafe Way Knoxville, TN 37932 USA Manufacturer : Radio Systems Corporation Address : 10427 Petsafe Way Knoxville, TN 37932 USA Equipment Under Test (EUT) : Product Name : Basic Remote Trainer Model No. : RFA-486, RFA-488, RFA-505 Rules : FCC CFR47 Part 15 Section 15.109:2010 Date of Test : Nov. 02~09, 2012 Date of Issue : Nov. 12, 2012 Test Result : PASS* Remarks: * The sample described above has been tested to be in compliance with the requirements of the rules listed above. The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Services (Shenzhen) Co., Ltd. Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen, Guangdong, China Testing location: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen, Guangdong, China Tel :+86-755-83551033 Fax:+86-755-83552400 Compiled by: Approved by: Zero Zhou / Project Engineer Philo Zhong / Manager Reference No.: WT12117325-S-S-F Page 2 of 23 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 2 Test Summary Test Items Test Requirement Test Method Result Radiated Emissions Part 15.109 ANSI C63.4: 2003 PASS Conducted Emissions Part 15.107 ANSI C63.4:2003 N/A Remark: PASS Test item meets the requirement FAIL Test item does not meet the requirement N/A Test case does not apply to the test object Reference No.: WT12117325-S-S-F Page 3 of 23 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 3 Contents Page 1 COVER PAGE............................................................................................................................... 1 2 TEST SUMMARY ......................................................................................................................................................................2 3 CONTENTS .................................................................................................................................................................................3 4 GENERAL INFORMATION.....................................................................................................................................................4 4.1 GENERAL DESCRIPTION OF E.U.T. ................................................................................................................................... 4 4.2 DETAILS OF E.U.T. ............................................................................................................................................................ 4 4.3 TEST FACILITY..................................................................................................................................................................... 4 4.4 TEST LOCATION................................................................................................................................................................... 4 5 EQUIPMENT USED DURING TEST ....................................................................................................................................5 5.1 EQUIPMENTS LIST................................................................................................................................................................ 5 5.2 MEASUREMENT UNCERTAINTY .......................................................................................................................................... 5 5.3 TEST EQUIPMENT CALIBRATION ........................................................................................................................................ 5 6 CONDUCTED EMISSIONS ....................................................................................................................................................6 7 RADIATED EMISSIONS .........................................................................................................................................................7 7.1 EUT OPERATION : .............................................................................................................................................................. 7 7.2 EUT SETUP ......................................................................................................................................................................... 8 7.3 SPECTRUM ANALYZER SETUP........................................................................................................................................... 9 7.4 TEST PROCEDURE ............................................................................................................................................................. 10 7.5 TEST RESULT..................................................................................................................................................................... 10 8 PHOTOGRAPHS – TEST SETUP .................................................................................................................................... 15 8.1 PHOTOGRAPH – RADIATION EMISSION TEST SETUP .................................................................................................... 15 9 PHOTOGRAPHS - CONSTRUCTIONAL DETAILS .................................................................................................... 17 9.1 EUT –APPEARANCE VIEW ............................................................................................................................................... 17 9.2 EUT – OPEN VIEW............................................................................................................…
Text truncated - open the document above for the full version.
Photographs of Testing Radiation Emission Test View Below 30MHz From 30MHz to 1GHz Above 1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 433.92 MHz - 433.92 MHz | - |

Stay & Play Wireless Fence
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
PetSafe HydroSphere 60 oz Cordless Fountain
Equipment Class
FDS - Part 15 Field Disturbance Sensor
GPS Tracker Collar
Equipment Class
DTS - Digital Transmission System
MURS radio device
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Dog Training Collar
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter