Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Shields ® Avoidance Solutions Indoor Micro Shields ® Owner’s Manual Please read this entire guide before operating. www.invisiblefence.com 2 Important Precautions • Invisible Fence ® Brand pet containment systems have contained over two million pets. However, there are some precautions you should take. • Read and retain manuals: Read the entire Owner’s Manual before using your new Indoor Micro Shields ® solution. If you have any questions after reading this manual, call your Invisible Fence ® Brand dealer. • Adhere to all warnings and cautions contained in any Invisible Fence ® Brand manual. Explanation of Attention Words and Symbols used in this guide This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE is used to address safe use practices not related to personal injury. • Not every pet can be trained to avoid the established boundary. Sometimes even a properly trained pet may cross theboundary. Therefore, Invisible Fence, Inc., as well as Invisible Fence ® Brand Distributors and Dealers cannot guaranteethe system will, in all cases, keep a customer’s pet within the established boundary. Accordingly, if a customer has reasonto believe that their pet may pose a danger to others, or harm itself, the customer should not rely solely upon the InvisibleFence ® Brand system to keep the pet from crossing the boundary. • Do not install, connect, or remove your system during a lightning storm. If the storm is close enough for you to hearthunder, it is close enough to create hazardous surges. • Read and follow the important tips on how to avoid pressure necrosis in your Invisible Fence ® Brand Computer Collar ® unit manual. • Train your pet according to the instructions in the Invisible Fence ® Brand training manuals. Complete all stepsbefore allowing your pet to run free. Do not become overly confident if your pet has become conditioned to theInvisible Fence ® Brand pet containment system sooner than expected. • Your Invisible Fence ® Brand dealer has professionally installed your pet containment system and ensured it is workingproperly. You will want to perform periodic maintenance checks to make sure the system is properly functioning for yourpet’s safe containment. • Check the Invisible Fence ® Brand transmitter periodically to make sure it is operating properly. To do this, simply bring theComputer Collar ® unit to the edge of the signal field to verify function. • Do not attempt to service any Invisible Fence ® Brand equipment. Refer all service to your authorized Invisible Fence ® Brand dealer. Only your authorized Invisible Fence ® Brand dealer should make adjustments to your pet containmentsystem. • All Invisible Fence ® Brand pet containment systems are designed for domesticated animal use only. Never attempt to usethis product for any purpose not specifically described in this manual. 3 Congratulations on your purchase of the Indoor Micro Shields ® solution. Please read and review this entire manual to become familiar with Indoor Micro Shields ® solution components and its operation. It is strongly recommended you review this information before using the product. The Indoor Micro Shields ® solution gives you control over the areas a pet or pets have access to inside your home. It is designed to work independently or to complement your Invisible Fence ® Brand Boundary Plus ® and/or 800 Series digital electronic pet containment system. The Indoor Micro Shields ® transmitter is designed for indoor use only. For information on or about Outdoor Shields ® products, please contact your local Invisible Fence ® Brand dealer or visit us at www.invisiblefence.com. This device is not designed to operate as acontainment transmitter. Table of Contents Important Precautions..................................................................................................... 2 Components.................................................................................................................... 4 How the Systems Works ..................................................................................................4 Operating Guide................................................................................................................5 Charging...........................................................................................................................5 Adjust Signal Field Range................................................................................................5 Verify Signal Field Range.................................................................................................5 Changing the Channel Setting on the Indoor Micro Shields ® transmitter.........................6 Multi-Area Shielding.........................................................................................................7 Programming the Computer Collar ® unit..........................................................................7 Training Guide.................................................................................................................8 For Pets Trained to the Invisible Fence ® Brand Outdoor Pet Containment System........8 For Pets New to Invisible Fence ® Brand .........................................................................8 Troubleshooting..............................................................................................................9 Battery Disposal..............................................................................................................10 Perchlorate Battery.....................................................................................…
Text truncated - open the document above for the full version.
Radio Systems Corporation Date: 2012.5.28 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: KE3-3002563 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Schematics KE3-3002563_SCH.pdf Block Diagram KE3-3002563_BlockDiagram.pdf Circuit Description KE3-3002563_CircuitDescription.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Radio Systems Corporation ---------------------------- [signature] Cindy Allen ---------------------------- [typed name]
Radio Systems Corporation FCC ID:KE3-3002563 POWER OF ATTORNEY May 28, 2012 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf shall have the same effect as acts of our own. This authorization expires on May 27,2013. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, Radio Systems Corporation, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Radio Systems Corporation .................................................................................... [signature] Cindy Allen .................................................................................... [typed name]
Page:21 of 25 Radio Systems Corporation FCC ID: KE3-3002563 WALTEK SERVICES Reference No.: WT12053359-S-S-F 8 Photographs - Constructional Details 8.1 EUT – Appearance View Page:22 of 25 Radio Systems Corporation FCC ID: KE3-3002563 WALTEK SERVICES Reference No.: WT12053359-S-S-F 8.2 EUT – Open View
FCC ID Label Sample for Model: RAC00-13547 FCC ID: KE3-3002563 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page:25 of 25 Radio Systems Corporation FCC ID: KE3-3002563 WALTEK SERVICES Reference No.: WT12053359-S-S-F 9 FCC Label This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)this device may not cause harmful interference,and (2) this device must accept any interference received, including interference that may cause undesired operation The Label must not be a stick-on paper. The Label on these products must be permanently affixed to the product and readily visible at the time of purchase and must last the expected lifetime of the equipment not be readily detachable. Proposed Label Location on EUT EUT Back View/proposed FCC Mark Location FCC ID: KE3-3002563 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page:23 of 25 Radio Systems Corporation FCC ID: KE3-3002563 WALTEK SERVICES Reference No.: WT12053359-S-S-F 8.3 EUT – PCB View Page:24 of 25 Radio Systems Corporation FCC ID: KE3-3002563 WALTEK SERVICES Reference No.: WT12053359-S-S-F
Page: 1 of 25 Radio Systems Corporation FCC ID: KE3-3002563 FCC TEST REPORT WALTEK SERVICES Reference No.: WT12053359-S-S-F FCC ID : KE3-3002563 Applicant : Radio Systems Corporation Address : 10427 PetSafe Way,Knoxville, TN 37932, USA Equipment Under Test (EUT) : Product Name : Micro Shields Model No. : RAC00-13547 Standards : FCC CFR47 Part 15 Section 15.209:2009 Date of Test : June 1 ~ 7, 2012 Date of Issue : June 7, 2012 Tested By : Zero Zhou / Engineer Reviewed By : Philo zhong / Manager Test Result : PASS Prepared By: Waltek Services (Shenzhen) Co., Ltd. 12B, West Tower, Aidi Building, No.5003, Binhe Road, Futian District, Shenzhen, Guangdong, China Tel :+86-755-83551033 Fax:+86-755-83552400 The sample detailed above has been tested to the requirements of Council Directives ANSI C63.4:2003. The test results have been reviewed against the Directives above and found to meet their essential requirements. Page:2 of 25 Radio Systems Corporation FCC ID: KE3-3002563 WALTEK SERVICES Reference No.: WT12053359-S-S-F 2 Test Summary Test Items Test Requirement Test Method Result Radiated Emissions (9kHz ~ 1GHz) Part 15.209 ANSI C63.4: 2003 PASS Conducted Emissions (150kHz ~ 30MHz) Part 15.207 ANSI C63.4:2003 PASS Page:3 of 25 Radio Systems Corporation FCC ID: KE3-3002563 WALTEK SERVICES Reference No.: WT12053359-S-S-F 3 Contents Page 1 COVER PAGE........................................................................................................................................................ 1 2 TEST SUMMARY .................................................................................................................................................. 2 3 CONTENTS............................................................................................................................................................. 3 4 GENERAL INFORMATION ................................................................................................................................ 4 4.1 CLIENT INFORMATION........................................................................................................................................... 4 4.2 GENERAL DESCRIPTION OF E.U.T. ........................................................................................................................ 4 4.3 DETAILS OF E.U.T................................................................................................................................................. 4 4.4 DESCRIPTION OF SUPPORT UNITS.......................................................................................................................... 4 4.5 STANDARDS APPLICABLE FOR TESTING................................................................................................................ 4 4.6 TEST FACILITY...................................................................................................................................................... 5 4.7 TEST LOCATION.................................................................................................................................................... 5 4.8 MEASUREMENT UNCERTAINTY............................................................................................................................. 5 5 EQUIPMENT USED DURING TEST .................................................................................................................. 6 6 CONDUCTED EMISSIONS.................................................................................................................................. 7 6.1 E.U.T. OPERATION................................................................................................................................................ 7 6.2 EUT SETUP........................................................................................................................................................... 8 6.3 CONDUCTED EMISSION TEST RESULT................................................................................................................... 8 7 RADIATED EMISSIONS .................................................................................................................................... 11 7.1 MEASUREMENT UNCERTAINTY........................................................................................................................... 12 7.2 EUT SETUP......................................................................................................................................................... 12 7.3 SPECTRUM ANALYZER SETUP............................................................................................................................. 13 7.4 TEST PROCEDURE................................................................................................................................................ 13 7.5 RADIATED EMISSIONS TEST RESULT................................................................................................................... 14 7.6 SUMMARY OF TEST RESULTS.............................................................................................................................. 14 7.7 PHOTOGRAPH – RADIATION EMISSION TEST SETUP............................................................................................ 19 7.8 PHOTOGRAPH – CONDUCTION EMISSION TEST SETUP......................................................................................... 20 8 PHOTOGRAPHS - CONSTRUCTIONAL DETAILS...................................................................................... 21 8.1 EUT – APPEARANCE VIEW................................................................................................................................. 21 8.2 EUT – OPEN VIEW.............................................................................................................................................. 22 8.3 EUT – PCB VIEW..................................................…
Text truncated - open the document above for the full version.
Page:19 of 25 Radio Systems Corporation FCC ID: KE3-3002563 WALTEK SERVICES Reference No.: WT12053359-S-S-F 7.7 Photograph – Radiation Emission Test Setup Below 30MHz Above 30MHz Page:20 of 25 Radio Systems Corporation FCC ID: KE3-3002563 WALTEK SERVICES Reference No.: WT12053359-S-S-F 7.8 Photograph – Conduction Emission Test Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.0075 MHz - 0.0105 MHz | - |

Stay & Play Wireless Fence
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
PetSafe HydroSphere 60 oz Cordless Fountain
Equipment Class
FDS - Part 15 Field Disturbance Sensor
GPS Tracker Collar
Equipment Class
DTS - Digital Transmission System
MURS radio device
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Dog Training Collar
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter