
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
- 1 -- 1 - www.innotek.net Instruction Guide 2 Manuel d’instructions 9 Handleiding 16 Instructivo 23 Istruzioni per l’uso 30 Bedienungsanleitung 37 - 2 -- 2 - www.innotek.net Thank you for choosing Innotek®. Through consistent use of our products, you can have a better behaved dog in less time than with other training tools. If you have any questions, please contact the Customer Care Center (Centre) at 1-800-826-5527 (U.S.A./Canada). For a listing of international Customer Care Center (Centre) telephone numbers, visit our website at www.innotek.net. To get the most protection out of your warranty, please register your product within 30 days at www.innotek.net/registerproduct.shtml. By registering, and keeping your receipt, you will enjoy the product’s full warranty and should you ever need to call the Customer Care Center (Centre), we will be able to help you faster. Most importantly, Innotek® will never give or sell your valuable information to anyone. INSTRUCTION GUIDEINSTRUCTION GUIDE THE KIT INCLUDESTHE KIT INCLUDES PREPARATIONPREPARATION EnglishEnglish Congratulations! You are now the owner of an Innotek® Spray Commander® Waterproof training system with remote control designed for your dog’s education. Your new Innotek® Spray Commander® system can be used to interrupt any of your dog’s unwanted behaviors (behaviours) such as running away and chasing, stealing objects or food, digging, jumping on guests, etc. This system will improve and strengthen dog- owner relationships because the correction is associated with the action and not the owner. It will allow you to redirect your dog’s attention and behavior (behaviour) while promoting a healthy emotional state. This instruction guide will provide you with all the information required to maximize the effi ciency of your new Innotek® Spray Commander®. How it works Innotek® Spray Commander® uses a remote control and a harmless spray collar to re-direct the attention of the distracted or misbehaving dog, or one that has learned that obedience is optional. It can be activated at a distance up to 250 ft (85 m). In addition to having two levels of spray to disrupt unwanted behaviors (behaviours), the Innotek® Spray Commander® also incorporates a sound signal for positive reinforcement. You can use it to let your dog know when the behavior (behaviour) he is engaged in is acceptable. The sound becomes a reward for your dog. This innovative system causes no secondary eff ects (fear, pain). • Spray device Waterproof • Remote control • Adjustable collar • Can of stainfree, hypo-allergenic spray • Two 6-volt alkaline batteries • Instruction guide Adjusting the collar to the spray device 1. Remove the keeper from the black collar (A). Pass the black collar (B) through the loops of the spray device (C). Put the keeper back on the collar (D). The curved edge of the keeper should face inward. AB C D - 3 -- 3 - www.innotek.net Adjust the collar to fi t like a regular collar. You should be able to easily pass two fi ngers between your dog’s neck and the device (A). We suggest that you check the collar regularly to make sure that it is well adjusted. Note: If these instructions are not properly followed, the buckle can easily be pulled off the collar. This could lead to the device being lost or damaged. Your dog must get used to the device before you actually start using it. We suggest that you make your dog wear the spray device during 4 to 5 days before inserting the battery and fi lling the device. At the same time, we also suggest that you remove and put the collar back frequently on your dog. Filling the device Inserting the battery 1. Set the device on a fl at surface, with the fi ll-up valve turned upwards. Shake the spray can before using it. 2. Hold the can upside down, then insert the aerosol tip in the fi ll-up valve – the deepest cavity (A) – then press down fi rmly for 10 seconds (B). Release pressure and press down for another 10 seconds, then release. Note: If spray is escaping as you attempt to fi ll the device, increase the downward pressure on the refi ll can to get a better seal. You cannot overfi ll the device. When completely fi lled, there should be enough gas in your device for 18-23 sprays. 1. Insert a coin into the slot of the battery cover and orient towards open position. Remove cover and insert one 6 Volt battery with positive terminal towards the inside of the device. Place cover back on. Screw cover towards off position. 2. Slide off the battery cover from the remote control and insert one 6-volt alkaline battery, respecting polarity (+ and -) (C, D). Slide the cover back on. NOTE : Check if the device is working by pressing the upper button no 1 on your remote control; you should hear a beep (make sure the spray device is in the “on” position). AB C D 2. Feed the free end of the collar into the slot of the buckle (A) from the back to the front. Then, thread the free end of the collar through the outside slot (B) from the front to the back. The free end should now hang on the outside, then thread the keeper (C). When you have completed this section, the assembled collar looks as illustrated (D). - 4 -- 4 - www.innotek.net DO’S AND DON’T’SDO’S AND DON’T’S • Never infl ict punishment, pain or cruelty on your pet – even if he refuses to listen. • Reward your pet when he listens and obeys your commands. • Never let the dog ignore a command he understands. • Do not use the spray when you want your dog to obey a command that he does not understand yet. • Never fi ll the device while your dog is wearing it because it may damage the fi ll-up valve. • Never fasten a leash (lead) to the Innotek® Spray Commander® collar. • To ensure that your dog does not make the connection between you and the Innotek® Spray Commander®, don’t let him see you prepare the device, neither for the fi rst try, nor for subsequent use. Keep your dog away while you prepare the device as well as when you fi ll it or change the battery. • Make sure the device i…
Text truncated - open the document above for the full version.
10427 Electric Ave Knoxville, TN. 37932 865-777-5404 www.petsafe.net AGENCY AGREEMENT Federal Communications Commission Date: April 18, 2011 P.O. Box 429 Columbia, MD 21045 Gentlemen: By signature below, we hereby authorize Intertek Testing Services (Mr. Terry Chan) to act on our behalf in front of the Federal Communications Commission with respect to all matters relating to certification of equipment under Part 15 of the FCC Rules. I further certify that no party (as defined in §1.2002(b) of CFR 47, 2004) to this application, including myself, is subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.,862. This appointment will remain in effect until December 31, 2011. Clifton P. Brick Product Safety and Regulatory Manager (FCC contact of record as of this date) Date: 5/2/2011
10427 Electric Ave Knoxville, TN. 37932 865-777-5404 www.petsafe.net Request for Confidentiality Federal Communications Commission Date: May 2, 2011 P.O. Box 429 Columbia, MD 21045 Applicant: Radio Systems Corporation FCC ID: KE3-33611130 (Tx) To whom it may concern, Request is hereby submitted by Radio Systems Corporation to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: • Schematics • Detailed Block diagrams • Detailed Operational/Functional Description • Bill of material/ parts list (if provided) Rationale for request for confidentiality: Radio Systems Corporation has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would give them significant competitive advantages in developing similar products. Clifton P. Brick Product Safety and Regulatory Manager (FCC contact of record as of this date) Date: 5/2/2011 KE3-33611131 (Rx)
INTERTEK TESTING SERVICE Report No.: HK11031093-1 FCC ID: KE3-33611131 IC: 2721A-33611131 Equipment Photographs Model : RFA-419R (External) INTERTEK TESTING SERVICE Report No.: HK11031093-1 FCC ID: KE3-33611131 IC: 2721A-33611131 Equipment Photographs Model : RFA-419R (External)
INTERTEK TESTING SERVICE Report No.: HK11031093-1 FCC ID: KE3-33611131 IC: 2721A-33611131 Equipment Photographs Model: RFA-419R (Internal) INTERTEK TESTING SERVICE Report No.: HK11031093-1 FCC ID: KE3-33611131 IC: 2721A-33611131 Equipment Photographs Model: RFA-419R (Internal) INTERTEK TESTING SERVICE Report No.: HK11031093-1 FCC ID: KE3-33611131 IC: 2721A-33611131 Equipment Photographs Model: RFA-419R (Internal)
- The test report only allows to be revised within the retention period unless further standard or the requirement was noticed. - This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Report No.: HK11031093-1 Radio Systems Corporation Application For Certification (Original Grant) (FCC ID: KE3-33611131) (IC: 2721A-33611131) Superheterodyne Receiver Prepared and Checked by: Approved by: Signed On File Wong Cheuk Ho, Herbert Engineer Chan Chi Hung, Terry Assistant Supervisor Date: June 14, 2011 INTERTEK TESTING SERVICES Report No.: HK11031093-1 FCC ID: KE3-33611131 IC: 2721A-33611131 i GENERAL INFORMATION Radio Systems Corporation BRAND NAME: Spray Commander, MODEL: RFA-419R FCC ID: KE3-33611131 IC: 2721A-33611131 Grantee: Radio Systems Corporation Grantee Address: 10427 Electric Ave., Knoxville, TN 37932, USA. Contact Person: Clifton Brick Tel: 865-218-1557 Fax: 865-671-6855 e-mail: [email protected] Manufacturer: Blue Ocean Innovation Limited Manufacturer Address: Room 1813. Fotan Industrial Centre, 26-28 Au Pui Wan Street, Fotan Hong Kong Brand Name: Spray Commander Model: RFA-419R Type of EUT: Superheterodyne Receiver Description of EUT: Remote Control for Pet Training Serial Number: N/A FCC ID / IC: KE3-33611131 / 2721A-33611131 Date of Sample Submitted: March 23, 2011 Date of Test: March 30, 2011 Report No.: HK11031093-1 Report Date: June 14, 2011 Environmental Conditions: Temperature: +10 to 40°C Humidity: 10 to 90% INTERTEK TESTING SERVICES Report No.: HK11031093-1 FCC ID: KE3-33611131 IC: 2721A-33611131 ii SUMMARY OF TEST RESULT Radio Systems Corporation BRAND NAME: Spray Commander, MODEL: RFA-419R FCC ID: KE3-33611131 IC: 2721A-33611131 TEST SPECIFICATION REFERENCE RESULTS Maximum Peak Output Power 15.247(b), (c) / RSS-210 A8.4 N/A Hopping Channel Carrier Frequencies Separation 15.247(e) / RSS-210 A8.1 N/A 20dB Bandwidth of the Hopping Channel 15.247(a) / RSS-210 A8.1 N/A Number of Hopping Frequencies 15.247(e) / RSS-210 A8.1 N/A Average Time of Occupancy of Hopping Frequency 15.247(e) / RSS-210 A8.1 N/A Antenna Conducted Spurious Emissions 15.247(d) / RSS-210 A8.5 N/A Radiated Spurious Emissions 15.247(d) / RSS-210 A8.5 N/A RF Exposure Compliance 15.247(i) / RSS-Gen 5.5 N/A Transmitter Power Line Conducted Emissions 15.207 / RSS-Gen 7.2.2 N/A Transmitter Field Strength 15.227 / RSS-310 3.8 N/A Transmitter Field Strength 15.229 / RSS-210 A2.7 N/A Transmitter Field Strength, Bandwidth and Timing Requirement 15.231(a) / RSS-210 A1.1.1 N/A Transmitter Field Strength, Bandwidth and Timing Requirement 15.231(e) / RSS-210 A1.1.5 N/A Transmitter Field Strength and Bandwidth Requirement 15.239 / RSS-210 A2.8 N/A Transmitter Field Strength and Bandwidth Requirement 15.249 / RSS-210 A2.9 N/A Transmitter Field Strength and Bandwidth Requirement 15.235 / RSS-310 3.9 N/A Receiver Radiated Emissions 15.109 / RSS-210 2.5 Pass Digital Device Conducted Emissions 15.107 / ICES-003 N/A Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is considered sufficient to comply with the pervisions of this section. 2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was contained within the frequency band designated (mentioned as above) which the EUT operated. The effects, if any, from frequency sweeping, frequency hopping, other modulation techniques and frequency stability over excepted variations in temperature and supply voltage were considered. INTERTEK TESTING SERVICES Report No.: HK11031093-1 FCC ID: KE3-33611131 IC: 2721A-33611131 iii Table of Contents 1.0 General Description....................................................................................... 1 1.1 Product Description ...................................................................................... 1 1.2 Related Submittal(s) Grants .......................................................................... 1 1.3 Test Methodology ......................................................................................... 1 1.4 Test Facility .................................................................................................. 1 2.0 System Test Configuration ............................................................................ 2 2.1 Justification................................................................................................... 2 2.2 EUT Exercising Software .............................................................................. 2 2.3 Special Accessories...................................................................................... 2 2.4 Equipment Modification................................................................................. 2 2.5 Measurement Uncertainty ............................................................................. 2 2.6 Support Equipment List and Description........................................................ 2 3.0 Emission Results .................…
Text truncated - open the document above for the full version.
INTERTEK TESTING SERVICE Report No: HK11031093-1 FCC ID: KE3-33611131 IC : 2721A-33611131 Configuration Photographs Worst-Case Radiated Emissions (Front View) Model: RFA-419R HK11031093-1 Model: RFA-419R side A INTERTEK TESTING SERVICE Report No: HK11031093-1 FCC ID: KE3-33611131 IC : 2721A-33611131 Configuration Photographs Worst-Case Radiated Emissions (Rear View) Model: RFA-419R HK11031093-1 Model: RFA-419R side B
2/F Garment Centre · Kowloon · Hong Kong
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 916 MHz - 916 MHz | - |

Stay & Play Wireless Fence
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
PetSafe HydroSphere 60 oz Cordless Fountain
Equipment Class
FDS - Part 15 Field Disturbance Sensor
GPS Tracker Collar
Equipment Class
DTS - Digital Transmission System
MURS radio device
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Dog Training Collar
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter