FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shan Yeun Co Ltd/
  3. KPG-RPP330

KPG-RPP330Wireless Personal Pager

Shan Yeun Co Ltd
Wireless Personal Pager - FCC ID KPG-RPP330 - Shan Yeun Co Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Dec 16, 2001
Application Purpose
Original Equipment
Date of Application
Dec 16, 2001
Equipment Note
Wireless Personal Pager
Frequency Range
298.00000000 - 298.00000000
Company
Shan Yeun Co Ltd
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

β†—

Block Diagram

β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Operational Description

β†—

Schematics

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

ID Label/Location Info

FCC ID LABEL FORMAT AND LOCATION Applicant: SHAN YEUN CO., LTD. FCC ID: KPG-RPP330 FCC ID: KPG-RPP330 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID LABEL AREA

Test Report

ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT CERTIFICATION TO FCC PART 15 REQUIREMENTS for INTENTIONAL RADIATOR Wireless Personal Pager MODEL NO: RPP-330 TRADE NAME: SHANTEX FCC ID NO: KPG-RPP330 REPORT NO: 01E9853 ISSUE DATE: November 26, 2001 Prepared for SHAN YEUN CO., LTD. 35, Lane 646, Sec. 2, Bin Hai Road Su-Ao, I-Lan, Taiwan, R. O. C. Prepared by COMPLIANCE ENGINE ERING SERVICES, INC. NO. 199, CHUNG SHENG ROAD, HSIN TIEN CITY, TAIPEI, TAIWAN, R. O. C. d.b.a. COMPLIANCE CERTIFICATION SERVICES REPORT NO: 01E9853 FCC ID: KPG-RPP330 DATE: November 26, 2001 COMPLIANCE ENGINEERING SERVICES, INC. TEL: (02) 2217-0894 FAX: (02) 2217-1254 NO. 199, CHUNG SHENG ROAD, HSIN TIEN CITY, TAIPEI, TAIWAN, R. O. C. This report shall not be reproduced except in full, without the written approval of CES. This document may be altered or revised by Compliance Engineering Services personnel only, and shall be noted in the revision section of the document. (CCS DOCUMENT NO: CCSTP4005) TABLE OF CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE........................................................................................1 2. Product Description.....................................................................................................................2 3. Test Facility..................................................................................................................................2 4. Measurement Standards...............................................................................................................2 5. Test Methodology........................................................................................................................2 6. Measurement Equipment Used....................................................................................................2 7. POWERLINE RFI LIMIT...........................................................................................................3 8. RADIATED EMISSION LIMITS...............................................................................................3 9. SYSTEM TEST CONFIGURATION.........................................................................................4 10. Test Procedure............................................................................................................................5 11. Equipment Modifications...........................................................................................................6 12. TEST RESULT..........................................................................................................................7 12.1 Maximum Modulation Percentage (M%)................................................................................7 12.2 The Emissions Bandwidth.......................................................................................................7 TEST DATA β€’ Emission Bandwidth Plot β€’ Radiated Emission Worksheet for Average Measurement REPORT NO: 01E9853 FCC ID: KPG-RPP330 DATE: November 26, 2001 PAGE NO: 1 COMPLIANCE ENGINEERING SERVICES, INC. TEL: (02)2217-0894 FAX: (02)2217-1254 NO. 199, CHUNG SHENG ROAD, HSIN TIEN CITY, TAIPEI, TAIWAN, R. O. C. This report shall not be reproduced except in full, without the written approval of CES. This document may be altered or revised by Compliance Engineering Services personnel only, and shall be noted in the revision section of the document. (CCS DOCUMENT NO: CCSTP4005) 1. VERIFICATION OF COMPLIANCE COMPANY NAME: SHAN YEUN CO., LTD. 35, Lane 646, Sec. 2, Bin Hai Road Su-Ao, I-Lan, Taiwan, R. O. C. CONTACT PERSON: Winship Chen TELEPHONE NO.: 886-3-990-7711 EUT DESCRIPTION: Wireless Personal Pager MODEL NAME/NUMBER: RPP-330 FCC ID: KPG-RPP330 DATE TESTED: November 15 & November 16, 2001 REPORT NUMBER: 01E9853 TYPE OF EQUIPMENT SECURITY EQUIPMENT (INTENTIONAL RADIATOR) EQUIPMENT TYPE Wireless Personal Pager MEASUREMENT PROCEDURE ANSI C63.4 / 1992 LIMIT TYPE CERTIFICATION FCC RULE CFR 47, PART 15 The above equipment was tested by Compliance Engineering Services, Inc. for compliance with the requirements set forth in the FCC CFR 47, PART 15. The results of testing in this report apply to the product/system which was tested only. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Warning : This document reports conditions under which testing was conducted and results of tests performed. This document may not be altered or revised in any way unless done so by Compliance Engineering Services, Inc. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by Compliance Engineering Services, Inc. will constitute fraud and shall nullify the document. RICK YEO / EMC MANAGER COMPLIANCE ENGINEERING SERVICES, INC. REPORT NO: 01E9853 FCC ID: KPG-RPP330 DATE: November 26, 2001 PAGE NO: 2 COMPLIANCE ENGINEERING SERVICES, INC. TEL: (02)2217-0894 FAX: (02)2217-1254 NO. 199, CHUNG SHENG ROAD, HSIN TIEN CITY, TAIPEI, TAIWAN, R. O. C. This report shall not be reproduced except in full, without the written approval of CES. This document may be altered or revised by Compliance Engineering Services personnel only, and shall be noted in the revision section of the document. (CCS DOCUMENT NO: CCSTP4005) 2. Product Description Fundamental Frequency 298 MHz Power Source 12V Transmitting Time Periodic < 5 seconds Associated Receiver Model Name: RPP-330 / (DoC) 3. Test Facility The open area test sites and conducted measurement facilities used to collect the radiated data are located at No. 199, Chung Sheng Road, Hsin Tien City, Taipei, Taiwan, R.O.C. The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and CISPR Publication 22. 4. Measurement Standards The site is constructed and calibrated in conformance with the requirements of ANSI C63.4/1992. 5. Test Methodology For an intentional radiator, the spectrum shall be investigated from the lowest rad…

Text truncated - open the document above for the full version.

Test Setup Photos

REPORT NO: 01E9853 FCC ID: KPG-RPP330 DATE: November 26, 2001 PAGE NO: 4 COMPLIANCE ENGINEERING SERVICES, INC. TEL: (02)2217-0894 FAX: (02)2217-1254 NO. 199, CHUNG SHENG ROAD, HSIN TIEN CITY, TAIPEI, TAIWAN, R. O. C. This report shall not be reproduced except in full, without the written approval of CES. This document may be altered or revised by Compliance Engineering Services personnel only, and shall be noted in the revision section of the document. (CCS DOCUMENT NO: CCSTP4005) 9. SYSTEM TEST CONFIGURATION Use a block of foam and combined it with EUT wrapping rubber band around it. This way it can test X.Y, and Z axis. To activate continuous transmission, place a small plastic block between rubber band and EUT push button. Radiated Open Site Test Set-up

Contact Information

Applicant

Winship Chen(Manager Director)
[email protected]886-3-9907711Fax: 886-3-9907722

Test Firm

Compliance Engineering ServicesSteve Hsu
[email protected]886-2-2217-0894Fax: 886-2-2217-1254

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231298 MHz - 298 MHz-

Other Applications from Shan Yeun Co Ltd

DSC - Part 15 Security/Remote Control Transmitter - FCC ID KPG-MOD900T - Shan Yeun Co Ltd
KPG-MOD900T

DSC - Part 15 Security/Remote Control Transmitter

May 13, 1999

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
KPG-RPC382-4R

R/C Receiver

Apr 18, 1995

Equipment Class

CRR - Superregenerative Receiver
KPG-RPC382-4T

RC Transmitter

Apr 17, 1995

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
KPG-FRD370R

Wireless Doorbell Receiver

Jan 16, 1995

Equipment Class

CRR - Superregenerative Receiver
KPG-FRD63872R

Wireless Doorbell Receiver

Jan 16, 1995

Equipment Class