FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Renishaw plc/
  3. KQGRMP40QE

KQGRMP40QERadio Machine Probe

Renishaw plc
Radio Machine Probe - FCC ID KQGRMP40QE - Renishaw plc
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Apr 02, 2020
Application Purpose
Original Equipment
Date of Application
Apr 02, 2020
Equipment Note
Radio Machine Probe
Frequency Range
2403.00000000 - 2481.00000000
Company
Renishaw plc
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗
↗

Block Diagram

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Quick-start guide H-6588-8500-01-A RMP40 EN Publications for this product are available by scanning the barcode or visiting www.renishaw.com/rmp40. DE Weitere Informationen zu diesem Produkt sind unter folgendem Link www.renishaw.de/rmp40 abrufbar. ES Las publicaciones para este producto están disponibles a través de www.renishaw.es/rmp40. FR Les documentations pour ce produit sont disponibles en visitant le site www.renishaw.fr/rmp40. IT La documentazione per questo prodotto è disponibile visitando il sito www.renishaw.it/rmp40. 日本語 本製品に関する資料は、 www.renishaw.jp/rmp40 からダウンロードいただけます。 Issued: xx.xxxx PL Publikacje dotyczące tego produktu są dostępne w witrynie www.renishaw.pl/rmp40. CS Dokumentaci k produktu najdete na www.renishaw.cz/rmp40. RU Документация по данному изделию доступна на сайте www.renishaw.ru/rmp40. 中文 (繁體) 請訪問雷尼紹網站以獲得此產品的的相關文件檔案: www.renishaw.com.tw/rmp40。 中文 (简体) 请访问雷尼绍网站以获得此产品的相关文档 www.renishaw.com.cn/rmp40。 한국어 이 제품의 관련 자료는 www.renishaw.co.kr/rmp40 에서 확인 가능 합니다. This page is intentionally left blank. Safety Information to the user The RMP40 is supplied with two non-rechargeable ½AA lithium-thionyl chloride batteries (Please refer to the RMP40 radio machine probe installation guide [Renishaw part no. H-6588-8504]). Lithium batteries must be approved to (BS EN 62133:2013 [IEC 62133:2012]). Once the charge in the batteries is depleted, do not attempt to recharge them. The use of this symbol on the batteries, packaging or accompanying documents indicates that used batteries should not be mixed with general household waste. Please dispose of the used batteries at a designated collection point. This will prevent potential negative effects on the environment and human health which could otherwise arise from inappropriate waste handling. Please contact your local authority or waste disposal service concerning the separate collection and disposal of batteries. All lithium and rechargeable batteries must be fully discharged or protected from short circuiting prior to disposal. Please ensure replacement batteries are of the correct type and are fitted in accordance with the instructions in the installation guide (Please refer to the RMP40 radio machine probe installation guide [Renishaw part no. H-6588-8504]) for further information. For specific battery operating, safety and disposal guidelines, please refer to the battery manufacturer’s literature. • Ensure that all batteries are always inserted with the correct polarity. • Do not store batteries in direct sunlight or rain. • Do not expose to heat or dispose of the batteries in a fire. • Avoid forced discharge of the battery. • Do not short-circuit or force discharge the batteries. • Do not disassemble, pierce, deform or apply excessive pressure to the batteries. • Do not swallow the batteries. • Keep the batteries out of the reach of children. • Do not allow batteries to get wet. • Do not mix new and used batteries or battery types, as this will result in reduced life and damage to the batteries. • If a battery is damaged, exercise caution when handling to avoid contact with electrolyte. Please ensure that you comply with international and national battery transport regulations when transporting batteries or the products. NOTE: Lithium batteries are classified as dangerous goods and strict controls apply to their shipment by air. To reduce the risk of shipment delays, if you need to return the RMP40 to Renishaw for any reason, do not return any batteries. In all applications involving the use of machine tools, eye protection is recommended. The RMP40 has a glass window. Handle with care if broken to avoid injury. Information to the machine supplier/installer It is the machine supplier’s responsibility to ensure that the user is made aware of any hazards involved during operation, including those mentioned in Renishaw product literature, and to ensure that adequate guards and safety interlocks are provided. Under certain circumstances, the probe signal may falsely indicate a probe seated condition. Do not rely on probe signals to halt the movement of the machine. Information to the equipment installer All Renishaw equipment is designed to comply with the relevant EU and FCC regulatory requirements. It is the responsibility of the equipment installer to ensure that the following guidelines are adhered to, in order for the product to function in accordance with these regulations: • any interface MUST be installed in a position away from any potential sources of electrical noise, i.e. power transformers, servo drives etc; • all 0 V/ground connections should be connected to the machine “star point” (the “star point” is a single point return for all equipment ground and screen cables) . This is very important and failure to adhere to this can cause a potential difference between grounds; • all screens must be connected as outlined in the user instructions; • cables must not be routed alongside high current sources, i.e. motor power supply cables etc, or be near high-speed data lines; • cable lengths should always be kept to a minimum. Equipment operation If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 7 Batteries½ AA (3.6 V) lithium-thionyl chloride × 2  Saft Tadiran Xeno LS 14250 SL-750 XL-050F × Dubilier Maxell Sanyo Tadiran Varta SB-AA02 ER3S CR 14250 SE SL-350, SL-550, TL-4902, TL-5902, TL-2150, TL-5101 CR ½ AA 8 1 Fitting the stylus 2 M-5000-3707 1,8 Nm – 2,2 Nm (1.3 lbf.ft – 1.6 lbf.ft) 9 3 CAUTION Please remove the battery isolation device from the battery compartment before use. ¬ Take care not to short the battery contacts as this may be a fire hazard. Ensure the contact strips are located securely. 1 2 ¬ 4 10 EN Configuring the probe Probe settings can be reviewed and configured by using the Opti Logic technique or Trigger Logic™ technique. The Probe Setup app enables the application of Opti Logic and provides interactive instructions and i…

Text truncated - open the document above for the full version.

Users Manual

Quick-start guide H-6588-8500-06-A RLP40 EN Publications for this product are available by scanning the barcode or visiting www.renishaw.com/rlp40. DE Weitere Informationen zu diesem Produkt sind unter folgendem Link www.renishaw.de/rlp40 abrufbar. ES Las publicaciones para este producto están disponibles a través de www.renishaw.es/rlp40. FR Les documentations pour ce produit sont disponibles en visitant le site www.renishaw.fr/rlp40. IT La documentazione per questo prodotto è disponibile visitando il sito www.renishaw.it/rlp40. 日本語 本製品に関する資料は、 www.renishaw.jp/rlp40 からダウンロードいただけます。 Issued: xx.xxxx PL Publikacje dotyczące tego produktu są dostępne w witrynie www.renishaw.pl/rlp40. CS Dokumentaci k produktu najdete na www.renishaw.cz/rlp40. RU Документация по данному изделию доступна на сайте www.renishaw.ru/rlp40. 中文 (繁體) 請訪問雷尼紹網站以獲得此產品的的相關文件檔案: www.renishaw.com.tw/rlp40。 中文 (简体) 请访问雷尼绍网站以获得此产品的相关文档 www.renishaw.com.cn/rlp40。 한국어 이 제품의 관련 자료는 www.renishaw.co.kr/rlp40 에서 확인 가능 합니다. This page is intentionally left blank. Safety Information to the user The RLP40 is supplied with two non-rechargeable ½AA lithium- thionyl chloride batteries (Please refer to the RLP40 radio machine probe installation guide [Renishaw part no. H-6588-8504]). Lithium batteries must be approved to (BS EN 62133:2013 [IEC 62133:2012]). Once the charge in the batteries is depleted, do not attempt to recharge them. The use of this symbol on the batteries, packaging or accompanying documents indicates that used batteries should not be mixed with general household waste. Please dispose of the used batteries at a designated collection point. This will prevent potential negative effects on the environment and human health which could otherwise arise from inappropriate waste handling. Please contact your local authority or waste disposal service concerning the separate collection and disposal of batteries. All lithium and rechargeable batteries must be fully discharged or protected from short circuiting prior to disposal. Please ensure replacement batteries are of the correct type and are fitted in accordance with the instructions in the installation guide (Please refer to the RLP40 radio machine probe installation guide [Renishaw part no. H-6588-8504]) for further information. For specific battery operating, safety and disposal guidelines, please refer to the battery manufacturer’s literature. • Ensure that all batteries are always inserted with the correct polarity. • Do not store batteries in direct sunlight or rain. • Do not expose to heat or dispose of the batteries in a fire. • Avoid forced discharge of the battery. • Do not short-circuit or force discharge the batteries. • Do not disassemble, pierce, deform or apply excessive pressure to the batteries. • Do not swallow the batteries. • Keep the batteries out of the reach of children. • Do not allow batteries to get wet. • Do not mix new and used batteries or battery types, as this will result in reduced life and damage to the batteries. • If a battery is damaged, exercise caution when handling to avoid contact with electrolyte. Please ensure that you comply with international and national battery transport regulations when transporting batteries or the products. NOTE: Lithium batteries are classified as dangerous goods and strict controls apply to their shipment by air. To reduce the risk of shipment delays, if you need to return the RLP40 to Renishaw for any reason, do not return any batteries. In all applications involving the use of machine tools, eye protection is recommended. The RLP40 has a glass window. Handle with care if broken to avoid injury. Information to the machine supplier/installer It is the machine supplier’s responsibility to ensure that the user is made aware of any hazards involved during operation, including those mentioned in Renishaw product literature, and to ensure that adequate guards and safety interlocks are provided. Under certain circumstances, the probe signal may falsely indicate a probe seated condition. Do not rely on probe signals to halt the movement of the machine. Information to the equipment installer All Renishaw equipment is designed to comply with the relevant EU and FCC regulatory requirements. It is the responsibility of the equipment installer to ensure that the following guidelines are adhered to, in order for the product to function in accordance with these regulations: • any interface MUST be installed in a position away from any potential sources of electrical noise, i.e. power transformers, servo drives etc; • all 0 V/ground connections should be connected to the machine “star point” (the “star point” is a single point return for all equipment ground and screen cables) . This is very important and failure to adhere to this can cause a potential difference between grounds; • all screens must be connected as outlined in the user instructions; • cables must not be routed alongside high current sources, i.e. motor power supply cables etc, or be near high-speed data lines; • cable lengths should always be kept to a minimum. Equipment operation If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 7 Batteries½ AA (3.6 V) lithium-thionyl chloride × 2  Saft Tadiran Xeno LS 14250 SL-750 XL-050F × Dubilier Maxell Sanyo Tadiran Varta SB-AA02 ER3S CR 14250 SE SL-350, SL-550, TL-4902, TL-5902, TL-2150, TL-5101 CR ½ AA 8 1 Fitting the stylus 2 M-5000-3707 1,8 Nm – 2,2 Nm (1.3 lbf.ft – 1.6 lbf.ft) 9 3 CAUTION Please remove the battery isolation device from the battery compartment before use. ¬ Take care not to short the battery contacts as this may be a fire hazard. Ensure the contact strips are located securely.. 1 2 ¬ 4 10 EN Configuring the probe Probe settings can be reviewed and configured by using the Opti Logic technique or Trigger Logic™ technique. The Probe Setup app enables the application of Opti Logic and provides interactive instructions and…

Text truncated - open the document above for the full version.

Block Diagram

Registered office Registered number New Mills, Wotton-under-Edge, 1106260, England Gloucestershire GL12 8JR Richard Warren Product Compliance & Quality Analyst Machine Tool Products Division (MPD) +44 1453 523240 [email protected] 23/01/2020 Element Materials Technology 100 Frobisher Business Park Leigh Sinton Road Malvern, Worcestershire WR14 1BX UK FCC ID: KQGRMP40QE IC ID: 3928A-RMP40QE Models (HVIN): RMP40QE, RMP40MQE, RLP40QE, RLP40HQE To whom it may concern, We, the undersigned, hereby authorize Element Materials Technology to act on our behalf, as our agent, in the following matters related to the FCC and/or Industry Canada approval of our products: report submittal, related correspondence, the signing of all documents relating to these matters, and any other lawful activity necessary to obtain such certification. Any act carried out by Element Materials Technology within the scope of this authorization shall have the same effect as our own. This authorization shall expire 12 months from original date. Yours faithfully, Richard Warren

Cover Letter(s)

Registered office Registered number New Mills, Wotton-under-Edge, 1106260, England Gloucestershire GL12 8JR Richard Warren Product Compliance & Quality Analyst Machine Tool Products Division (MPD) +44 1453 523240 [email protected] 23/01/2020 Element Materials Technology 100 Frobisher Business Park Leigh Sinton Road Malvern, Worcestershire WR14 1BX UK To Whom It May Concern: We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application, is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. Yours faithfully, Richard Warren

Cover Letter(s)

Registered office Registered number New Mills, Wotton-under-Edge, 1106260, England Gloucestershire GL12 8JR Richard Warren Product Compliance & Quality Analyst Machine Tool Products Division (MPD) +44 1453 523240 [email protected] 23/01/2020 Element Materials Technology 100 Frobisher Business Park Leigh Sinton Road Malvern, Worcestershire WR14 1BX UK Re: Declaration of Similarity FCC ID: KQGRMP40QE Please be advised that the differences between models RMP40QE and RMP40MQE are a minor mechanical variation to the bottom of the enclosure, allowing for fitment of mechanical adaptors and extensions. The differences between the RMP40QE and the RLP40QE are minor mechanical variations to the enclosure to protect against damage in harsh machining environments. The difference between the RLP40QE and RLP40HQE are a stronger internal mechanical spring. They can share RF test data because all three models are electronically identical. Yours faithfully, Richard Warren

Cover Letter(s)

Registered office Registered number New Mills, Wotton-under-Edge, 1106260, England Gloucestershire GL12 8JR Richard Warren Product Compliance & Quality Analyst Machine Tool Products Division (MPD) +44 1453 523240 [email protected] 23/01/2020 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re: Request for confidentiality FCC ID: KQGRMP40QE To whom it may concern, We hereby respectfully request that under the provision of 47 CFR 0.459 and 0.457(d) the documents listed below and attached with this application for certification be provided with confidential status. • Schematics • Operational Description • Block Diagrams • PCB Layout • Parts List Any exhibit / information for which we have requested confidentiality, but which may not be accorded such treatment by the FCC, should be returned to us. The documents listed above contain trade secrets that are treated as confidential by us. Substantial competitive harm to us could result should they be made available to the public. Yours faithfully, Richard Warren

External Photos

RMP40QE RMP40MQE RLP40QE

ID Label/Location Info

Registered office Registered number New Mills, Wotton-under-Edge, 1106260, England Gloucestershire GL12 8JR Richard Warren Product Compliance & Quality Analyst Machine Tool Products Division (MPD) +44 1453 523240 [email protected] 27/01/2020 RMP40QE and variants – placement of Radio Approval ID numbers and model numbers. Please note; these images do not depict the complete product, only the engraved part. Registered office Registered number New Mills, Wotton-under-Edge, 1106260, England Gloucestershire GL12 8JR

RF Exposure Info

5HSRUW1XPEHU75$% 5)3DJHRI  5)([SRVXUH  .'%  6HFWLRQ*HQHUDO6$5WHVWUHGXFWLRQDQGH[FOXVLRQJXLGDQFH  )RU6WDQGDORQH6$5H[FOXVLRQFRQVLGHUDWLRQZKHQ6$5([FOXVLRQ7KUHVKROGUHTXLUHPHQWLQ.'% LVVDWLVILHGVWDQGDORQH6$5HYDOXDWLRQIRUJHQHUDOSRSXODWLRQH[SRVXUHFRQGLWLRQVE\ PHDVXUHPHQWRUQXPHULFDOVLPXODWLRQLVQRWUHTXLUHG  ,QWKHIUHTXHQF\UDQJHEHORZ0+]WR*+]DQGWHVWVHSDUDWLRQGLVWDQFHRIPPWKH6$57HVW ([FOXVLRQ7KUHVKROGIRURSHUDWLRQLQWKH±0+]EDQGZLOOEHGHWHUPLQHGDVIROORZV  6$5([FOXVLRQ7KUHVKROG 6$5(7   6$5([FOXVLRQ7KUHVKROG 6WHS6WHS  6WHS   17 > 0376' $  ¥I *+] @  17 1XPHULF7KUHVKROG IRUJ6$5DQGIRUJ6$5  03 0D[3RZHURIFKDQQHO P:  LQFWXQHXS  76' $  0LQ7HVWVHSDUDWLRQ'LVWDQFHRUPP ZKLFKHYHULVORZHU    :HFDQWUDQVSRVHWKLVIRUPXODWRDOORZXVWRILQGWKHPD[LPXPSRZHURIDFKDQQHODOORZHGDQG FRPSDUHWKLVWRWKHPHDVXUHGPD[LPXPSRZHU    > 17[76' $ ¥I *+] @  )RU'LVWDQFHV*UHDWHUWKDQPP6WHSDSSOLHV  6WHS   76' % ±PP  `   :KHUH 76' %  0LQ7HVWVHSDUDWLRQ'LVWDQFH PP   5HSRUW1XPEHU75$% 5)3DJHRI 2SHUDWLQJ)UHTXHQF\*+]  6$5(7 > [ ¥@^ ±  `  6$5(7 >@  `  6$5(7 P:   2SHUDWLQJ)UHTXHQF\*+]  6$5(7 > [ ¥@^ ±  ` 6$5(7 >@  `  6$5(7 P:   2SHUDWLQJ)UHTXHQF\*+]  6$5(7 > [ ¥@^ ±  ` 6$5(7 >@  `  6$5(7 P:    0RGH (YDOXDWLRQ)UHTXHQF\0+] 6$5([FOXVLRQ7KUHVKROGP: &RQGXFHG3RZHUG%P $QWHQQD*DLQG%L (,53P: 6$5(YDOXDWLRQ Exempt 7KHUHIRUHVWDQGDORQH6$5HYDOXDWLRQIRUJHQHUDOSRSXODWLRQH[SRVXUHFRQGLWLRQVE\PHDVXUHPHQWRU QXPHULFDOVLPXODWLRQLVQRWUHTXLUHG  5HSRUW1XPEHU75$% 5)3DJHRI 2SHUDWLQJ)UHTXHQF\*+]  6$5(7 > [ ¥@^ ±  `  6$5(7 >@  `  6$5(7 P:   2SHUDWLQJ)UHTXHQF\*+]  6$5(7 > [ ¥@^ ±  ` 6$5(7 >@  `  6$5(7 P:  2SHUDWLQJ)UHTXHQF\*+]  6$5(7 > [ ¥@^ ±  ` 6$5(7 >@  `  6$5(7 P:   0RGH (YDOXDWLRQ)UHTXHQF\0+] 6$5([FOXVLRQ7KUHVKROG:DWWV &RQGXFHG3RZHUG%P $QWHQQD*DLQG%L (,53P: 6$5(YDOXDWLRQ Exempt 7KHUHIRUHVWDQGDORQH6$5HYDOXDWLRQIRUJHQHUDOSRSXODWLRQH[SRVXUHFRQGLWLRQVE\PHDVXUHPHQWRU QXPHULFDOVLPXODWLRQLVQRWUHTXLUHG  

Test Report

RF916 10.0 Report on the Radio Testing For Renishaw Plc on RMP40QE Report no. TRA-046251-47-00B 2 April 2020 RF916 10.0 REPORT ON THE RADIO TESTING OF A Renishaw Plc RMP40QE WITH RESPECT TO SPECIFICATION FCC 47CFR 15.247 TEST DATE: 21st November 2019 - 20th December 2019 Written by: S Garwell, D Moncayola, Radio Test Engineer Approved by: J Charters Lab Manager Date: 2 April 2020 Disclaimers: [1] THIS DOCUMENT MAY BE REPRODUCED ONLY IN ITS ENTIRETY AND WITHOUT CHANGE [2] THE RESULTS CONTAINED IN THIS DOCUMENT RELATE ONLY TO THE ITEM(S) TESTED Report Number: TRA-046251-47-00B Issue: B Report Number: TRA-046251-47-00B RF916 10.0 Page 3 of 79 1 Revision Record Issue Number Issue Date Revision History A 29 January 2020 Original B 2 April 2020 Typographical Corrections Report Number: TRA-046251-47-00B RF916 10.0 Page 4 of 79 2 Summary TEST REPORT NUMBER: TRA-046251-47-00B WORKS ORDER NUMBER: TRA-046254-00 PURPOSE OF TEST: USA: Testing of radio frequency equipment per the relevant authorization procedure of chapter 47 of CFR (code of federal regulations) Part 2, subpart J.. TEST SPECIFICATION(S): 47CFR15.247 EQUIPMENT UNDER TEST (EUT): RMP40QE EQUIPMENT VARIANTS: RMP40MQE, RLP40QE, RLP40HQE FCC IDENTIFIER: KQGRMP40QE EUT SERIAL NUMBER: 1PUF52 Conducted 1PRQ12 Radiated MANUFACTURER/AGENT: Renishaw Plc ADDRESS: New Mills Wotton Under Edge Gloucestershire GL12 8JR United Kingdom CLIENT CONTACT: Rich Warren  01453 523240  [email protected] TEST DATE: 21st November 2019 - 20th December 2019 TESTED BY: S Garwell, D Moncayola Element Report Number: TRA-046251-47-00B RF916 10.0 Page 5 of 79 2.1 Test Summary Test Method and Description Requirement Clause47CFR15 Applicable to this equipment Result / Note Radiated spurious emissions (restricted bands of operation and cabinet radiation) 15.205 Pass Note 4 AC power line conducted emissions 15.207 Note 1 Carrier frequency separation 15.247(a)(1) Pass Note 2 Number of hopping channels 15.247(a)(1) (i), (ii) and (iii) Pass Note 2 Average time of occupancy 15.247(a)(1) (i), (ii) and (iii) Pass Note 2 Maximum peak conducted output power 15.247 (a)(1), (b)(1) and (b)(2) Pass Note 2 Conducted carrier power Peak 15.247(b)(3) Pass Note 3 Max. Power spectral density, conducted 15.247(e) Pass Note 3 20dB emission bandwidth 15.247(a)(1) (i) and (ii) Pass Note 2 Occupied bandwidth 15.247(a)(2) Pass Note 3 Out-of-band emissions 15.247(d) Pass Note 4 Notes: 1 Not applicable EUT is battery powered 2 Applicable for Mode 1 and Mode 2 – FHSS Operation 3 Applicable for Mode 2 – DTS operation 4 Applicable for Mode 1 and Mode 2 (both FHSS and DTS Operation) EUT uses same modulation techniques for both FHSS and DTS operation The results contained in this report relate only to the items tested, in the condition at time of test, and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. The apparatus was set up and exercised using the configurations, modes of operation and arrangements defined in this report only. Any modifications made are identified in Section 8 of this report. Particular operating modes, apparatus monitoring methods and performance criteria required by the standards tested to have been performed except where identified in Section 5.2 of this test report (Deviations from Test Standards). Report Number: TRA-046251-47-00B RF916 10.0 Page 6 of 79 3 Contents 1 Revision Record ............................................................................................................................... 3 2 Summary .......................................................................................................................................... 4 2.1 Test Summary ......................................................................................................................................... 5 3 Contents ........................................................................................................................................... 6 4 Introduction ....................................................................................................................................... 8 5 Test Specifications ........................................................................................................................... 9 5.1 Normative References ............................................................................................................................. 9 5.2 Deviations from Test Standards .............................................................................................................. 9 6 Glossary of Terms .......................................................................................................................... 10 7 Equipment Under Test .................................................................................................................... 11 7.1 EUT Identification .................................................................................................................................. 11 7.2 Equipment Variants ............................................................................................................................... 11 7.3 System Equipment ................................................................................................................................. 11 7.4 EUT Mode of Operation ......................................................................................................................... 11 7.4.1 Transmission ................................................................................................................................. 11 7.5 EUT Radio Parameters .......................................................................................................................... 12 7.5.1 General .......................................................................................................................................... 12 7.6 EUT Descrip…

Text truncated - open the document above for the full version.

Test Setup Photos

5HSRUW1XPEHU75$% 5)3DJHRI 9.2 General Set-up Photograph  7KHIROORZLQJSKRWRJUDSKVKRZVEDVLF(87VHWXS     9.3 Measurement software  :KHUHDSSOLFDEOHWKHIROORZLQJVRIWZDUHZDVXVHGWRSHUIRUPPHDVXUHPHQWVFRQWDLQHGZLWKLQWKLV UHSRUW  (OHPHQW(PLVVLRQV5 6HH1RWH  (OHPHQW7UDQVPLWWHU%HQFK7HVW 6HH1RWH  (76/LQGJUHQ(03RZHU9  1RWH  7KHYHUVLRQRIWKH(OHPHQWVRIWZDUHXVHGLVUHFRUGHGLQWKHUHVXOWVVKHHWVFRQWDLQHGZLWKLQWKLVUHSRUW  5HSRUW1XPEHU75$% 5)3DJHRI 11.5 Test Set-up Photographs     11.6 Test Equipment  Equipment Equipment Element Due For Description Manufacturer Type No Calibration 6SHFWUXP$QDO\VHU5 6)685()  %LORJ&KDVH&%/$8 /RJ3HULRGLF$QW&KDVH83$/ 3UH$PS:DWNLQV-RKQVRQ8 %$JLOHQW3UH$PS/ *+]+RUQ(0&2/ 

Test Setup Photos

5HSRUW1XPEHU75$% 5)3DJHRI 9.2 General Set-up Photograph  7KHIROORZLQJSKRWRJUDSKVKRZVEDVLF(87VHWXS     9.3 Measurement software  :KHUHDSSOLFDEOHWKHIROORZLQJVRIWZDUHZDVXVHGWRSHUIRUPPHDVXUHPHQWVFRQWDLQHGZLWKLQWKLV UHSRUW  (OHPHQW(PLVVLRQV5 6HH1RWH  (OHPHQW7UDQVPLWWHU%HQFK7HVW 6HH1RWH  (76/LQGJUHQ(03RZHU9  1RWH  7KHYHUVLRQRIWKH(OHPHQWVRIWZDUHXVHGLVUHFRUGHGLQWKHUHVXOWVVKHHWVFRQWDLQHGZLWKLQWKLVUHSRUW  5HSRUW1XPEHU75$% 5)3DJHRI 11.5 Test Set-up Photographs     11.6 Test Equipment  Equipment Equipment Element Due For Description Manufacturer Type No Calibration 6SHFWUXP$QDO\VHU5 6)685()  %LORJ&KDVH&%/$8 /RJ3HULRGLF$QW&KDVH83$/ 3UH$PS:DWNLQV-RKQVRQ8 %$JLOHQW3UH$PS/ *+]+RUQ(0&2/   

Contact Information

Applicant

Richard Warren(Product Compliance & Quality Analyst)
[email protected]441453524524Fax: 441453524201

Test Firm

Element Materials Technology Warwick LtdKeith Wright
[email protected]+44 1926 478478Fax: +44 1926 478479

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.50 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This Grant covers the following electrically identical model numbers: RMP40QE, RMP40MQE, RLP40QE and RLP40HQE.

Other Applications from Renishaw plc

KQGRUP60QE

The RUP60 is a radio probe capable of ultrasonic thickness measurement of parallel-sided metal components where access is restricted to a single side.

Mar 25, 2026

Equipment Class

DTS - Digital Transmission System
KQGRMP400SQE

The Renishaw RMP400S is a radio transmission probe capable of both touch trigger and scanning measurement.

Mar 13, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
RMI-QE Radio Machine Interface - FCC ID KQGRMI-QE - Renishaw plc
KQGRMI-QE

RMI-QE Radio Machine Interface

Mar 23, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Radio Machine Probe - FCC ID KQGRMP60QE - Renishaw plc
KQGRMP60QE

Radio Machine Probe

Apr 07, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Radio Tool Setter - FCC ID KQGRTSQE - Renishaw plc
KQGRTSQE

Radio Tool Setter

Apr 07, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter