CEILINGFANREMOTECONTROLLER OPERATIONANDINSTALLATIONINSTRUCTIONS (Pleasekeepthisinstructionpamphlet.) IMPORTANTPOINTSTOREMEMBER: 1.Readandsavetheseinstructions. 2.Pleasenotethatallfixedwiringappliancesshouldbeinstalledbyaqualifiedelectrician. 3.Thesupplytotheremotecontrolreceivershouldbeconnectedthroughamainsswitch,i.e.existingwallswitch. 4.Disconnectfrompowersupplyatwallswitchbeforeworkingonremotecontrolreceiverorceilingfan. 5.Installreceiverintotheceilingfancanopyofthefantoensureproperprotection. 6.ThisunitistobeusedforthecontrolofceilingfanandinaAC110/120V60Hzpowersupplyonly. 7.Donotinstallindamplocationsorimmerseinwater.(Forindooruseonly.) 8.Donotpullonorcutleadsshorter. 9.Donotdroporbumptheunit. 10.PLEASENOTE:Thebatterywillweakenwithageandshouldbereplacedbeforeleakingtakesplaceasthiswill damagethetransmitter.Disposeofusedbatteryproperly,keepthebatteryoutofreachofchildren. 11.CAUTION:Toreducetheriskoffireorinjury,donotusethisproductinconjunctionwithanyvariable(rheostat) wallcontrol. INSTALLATIONINSTRUCTIONS 1.CeilingfanmustbesetatHIGHspeedandlightkit(Ifany)atONpositionbypressingthe“LightSwitch”after installation. 2.Oncetheconnectionhasbeenmade,thereceiverinsertsintothedroprodhangingbracket.Thecanopycomesupto coverthereceiverandbracket. 3.ForbetterremoteperformancewithWinksystem,letT-shapeantennastuckorscrewonceilingandoutsideofthe steelcanopy. IMPORTANT YOUMUSTSETCEILINGFANMANUALSWITCHTOHIGHSPEEDANDLIGHTKIT (IFANY)TOONPOSITIONBEFOREOPERATINGREMOTECONTROL. CAUTION:INCORRECTWIRECONNECTIONWOULDDAMAGETHISRECEIVER. CODESWITCH 1.CODESWITCH:Codesaresetbypushingdipswitchesupordown.Itisimperativethatthecodeusedforboth transmitterandreceiverisexactlythesame,otherwiseremotecontrollerwillnotwork.Pleasenotethecodeswitch willenableyoutooperateasecondremotecontrollerindependently.Forexample,ifyouhavetwoceilingfanswith2 remotecontrolunits,set2differentcodesforeachsetoftransmitter/receivers.Thismeansyoucanoperateeach ceilingfanindependently. 2.Yourremotecontrolisreadyforuseafter2pcsDC1.5V/AAAbatteriesinstallation. LIGHTFUNCTIONSELECTSWITCH Ifinstalledenergylightontoceilingfan,pleasesetthe“lightfunctionselectswitch”“lightfunctionselectswitch”toon/off position,”O”.Ifinstalledtungstenlightontoceilingfan,pleasesetthe“lightfunctionselectswitch”todimmerposition,” D”. FUNCTIONSOFTRANSMITTER Thepowerbuttonwillturnthefanandlightpoweronoroffwhenpressthisbuttonwithin3 seconds.Whenyouholdthepowerbuttonover3seconds,the“walkawaytimedelay” functionisactivated.Whenpressthebuttoneachtime,the4pcsLEDswillon.If youwanttocancel“walkawaytimedelay”function,youcouldpressanybuttonoftransmitter. IfdipswitchtoON,thenlightkitwillblinkonce,turnoffin30seconds.IfdipswitchtoDIM, thenlightkitwilldimto50%,turnoffin30seconds. 1 st timepressthebutton,fourLEDsareonandturnfanonhighspeed 2ndtimepressthebutton,leftthreeLEDsareonandturnfanonmediumspeed 3rdtimepressthebutton,lefttwoLEDsisonandturnfanonlowspeed 4thtimepressthebutton,leftoneLEDisonandturnfanonlowerspeed 5thtimepressthebutton,andturnfanoff Pressthebutton,LEDswillonabout3seconds,forsetfanspeedbeingturnedandchangedatrandom.Ifyou wanttocancelthisfunction,pressfanbuttonorpowerbutton. Whenfanison,pressthisbuttonforsetfanturnoffautomaticallyafter2hours,4hours,8hoursoroff directly.TheLEDforeachtimerisonabout3secondsaspressingthebuttonforselection.Ifyouwantto cancelthisfunction,pressfanbuttonorpowerbuttonortimeroff. ON/OFF-Pressandreleaseimmediatelytoturnonoroffthelight DIMMER-Pressandholdontodimmerorbrightenthelight.(Forthetungstenbulband“lightfunctionselect switch”isatDposition.) TRANSMITTER MR101Z ToassurecontinuedFCCcompliance: FEDERALCOMMUNICATIONSCOMMISSIONINTERFERENCESTATEMENT ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15of theFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidential installation.Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedin accordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisno guaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterference toradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouraged totrytocorrecttheinterferencebyoneormoreofthefollowingmeasures: --Reorientorrelocatethereceivingantenna.--Increasetheseparationbetweentheequipmentandreceiver.--Connect theequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.--Consultthedealeror anexperiencedradio/TVtechnicianforhelp. CAUTION: Anychangesormodificationsnotexpresslyapprovedbythegranteeofthisdevicecouldvoidtheuser'sauthorityto operatetheequipment. FCCID:KUJCE10406 ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)This devicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation.
Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller FCC ID : KUJCE10406 EUT External Photos Photo 1 General Appearance (Front & Side View) Photo 2 General Appearance (Back & Side View)
Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller FCC ID : KUJCE10406 ID Label Location z Label Placement Location (Front View of EUT) z ID Label Format ID Label Placement Location FCC IDKUJCE10406 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller FCC ID : KUJCE10406 EUT Internal Photos Figure 3 Internal View (Removed Cover) Figure 4 Internal View (Removed Cover) Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller FCC ID : KUJCE10406 Figure 5 Internal View (Removed Shield Cover, Main Board, Front View) Figure 6 Internal View (Main Board, Back View) Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller FCC ID : KUJCE10406 Figure 7 Internal View (Control Board, Front View) Figure 8 Internal View (Control Board, Back View) Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller FCC ID : KUJCE10406 Figure 9 RF Module, Front View Figure 10 RF Module, Removed Shield Cover, Front & Back View Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller FCC ID : KUJCE10406 Figure 11 RF Antenna, Removed Shield Cover Figure 12 RF Antenna, Internal View Front & Back View
Maximum Permissive Exposure FCC ID: KUJCE10406 Product Name: Ceiling Fan Remote Controller Model No: MR101Z 1. According to FCC CFR 47 §1.1310, the criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b). Table 1 Limits for Maximum Permissible Exposure 2. MPE Calculation Chungear Industrial Co., Ltd declares that the product described above has been evaluated and found to comply with the RF exposure limits for humans, as specified based on ANSI/FCC recommendation. Based on safety distance (r) 20cm, the antenna gain (G) is 2.188 Numerical, and the highest power output (P) is 18.113mW, the power density (S) is 0.007884mW/cm^2. RF Exposure Calculations: S = (P * G) / (4* * r^2) or r = (P * G) / (4 * * S) Where : Based on safety distance (r)= 20 cm Highest Power Output (P)= 12.58 dBm = 18.113mW Antenna Gain (G)= 3.4 dBi = 2.188Numerical MPE (S) = (P*G) / (4*π*r 2 ) = = (18.113*2.188)/(4*4*π*20 2 )= 0.007884 mW/cm 2 Sincerely Yours, ____________________________________ Mr. Ben Cheng Manager AUDIX Technology Corporation
Page 1 of 40 AUDIX Technology Corp. Tel: +886 2 26099301 No. 53-11, Dingfu, Linkou, Dist., Fax: +886 2 26099303 New Taipei City244, Taiwan File Number: C1M1508198 Report Number: EM-F150636 This test report may be reproduced in full only. The document may only be updated by AUDIX Technology Corp. personnel Any changes will be noted in the Document History section of the report. FCC 15.247 2.4 GHz Report for Chungear Industrial Co., Ltd 106 Kanho Rd., Taichung, Taiwan Product Name : Ceiling Fan Remote Controller Model Name : MR101Z FCC ID : KUJCE10406 Page 2 of 40 AUDIX Technology Corp. Tel: +886 2 26099301 No. 53-11, Dingfu, Linkou, Dist., Fax: +886 2 26099303 New Taipei City244, Taiwan File Number: C1M1508198 Report Number: EM-F150636 This test report may be reproduced in full only. The document may only be updated by AUDIX Technology Corp. personnel Any changes will be noted in the Document History section of the report. TABLE OF CONTENTS Description Page TEST REPORT CERTIFICATION ............................................................................................. 4 1. REPORT HISTORY.............................................................................................................. 5 2. SUMMARY OF TEST RESULTS ....................................................................................... 6 3. GENERAL INFORMATION ............................................................................................... 7 3.1. Description of EUT ..................................................................................................................... 7 3.2. EUT Specifications Assessed in Current Report ...................................................................... 8 3.3. Antenna Information .................................................................................................................. 8 3.4. Test Configuration ...................................................................................................................... 9 3.5. Tested Supporting System List ................................................................................................ 10 3.6. Setup Configuration ................................................................................................................. 10 3.7. Operating Condition of EUT ................................................................................................... 10 3.8. Description of Test Facility ...................................................................................................... 11 3.9. Measurement Uncertainty ....................................................................................................... 11 4. MEASUREMENT EQUIPMENT LIST ............................................................................ 12 4.1. Conducted Emission Measurement ......................................................................................... 12 4.2. Radiated Emission Measurement ............................................................................................ 12 4.3. RF Conducted Measurement ................................................................................................... 12 5. CONDUCTED EMISSION MEASUREMET ................................................................... 13 5.1. Block Diagram of Test Setup ................................................................................................... 13 5.2. Power Line Conducted Emission Limit .................................................................................. 13 5.3. Test Procedure .......................................................................................................................... 13 5.4. Conducted Emission Measurement Results ........................................................................... 14 6. RADIATED EMISSION MEASUREMENT .................................................................... 16 6.1. Block Diagram of Test Setup ................................................................................................... 16 6.2. Radiated Emission Limits ........................................................................................................ 17 6.3. Test Procedure .......................................................................................................................... 17 6.4. Measurement Result Explanation ........................................................................................... 18 6.5. Test Results ................................................................................................................................ 18 7. 6dB BANDWIDTH MEASUREMENT ............................................................................. 29 7.1. Block Diagram of Test Setup ................................................................................................... 29 7.2. Specification Limits .................................................................................................................. 29 7.3. Test Procedure .......................................................................................................................... 29 7.4. Test Results ................................................................................................................................ 29 8. MAXIMUM PEAK OUTPUT POWER MEASUREMENT ........................................... 31 8.1. Block Diagram of Test Setup ................................................................................................... 31 8.2. Specification Limits .................................................................................................................. 31 8.3. Test Procedure .......................................................................................................................... 31 8.4. Test Results ................................................................................................................................ 32 9…
Text truncated - open the document above for the full version.
APPENDIX A AUDIX Technology Corp. Tel: +886 2 26099301 No. 53-11, Dingfu, Linkou, Dist., Fax: +886 2 26099303 New Taipei City244, Taiwan File Number: C1M1508198 Report Number: EM-F150636 This test report may be reproduced in full only. The document may only be updated by AUDIX Technology Corp. personnel Any changes will be noted in the Document History section of the report. APPENDIX A TEST PHOTOGRAPHS (Model: MR101Z) APPENDIX A-Page 1 of 3 AUDIX Technology Corp. Tel: +886 2 26099301 No. 53-11, Dingfu, Linkou, Dist., Fax: +886 2 26099303 New Taipei City244, Taiwan File Number: C1M1508198 Report Number: EM-F150636 This test report may be reproduced in full only. The document may only be updated by AUDIX Technology Corp. personnel Any changes will be noted in the Document History section of the report. A.1 Conducted Emission Measurement APPENDIX A-Page 2 of 3 AUDIX Technology Corp. Tel: +886 2 26099301 No. 53-11, Dingfu, Linkou, Dist., Fax: +886 2 26099303 New Taipei City244, Taiwan File Number: C1M1508198 Report Number: EM-F150636 This test report may be reproduced in full only. The document may only be updated by AUDIX Technology Corp. personnel Any changes will be noted in the Document History section of the report. A.2 Radiated Measurement at Semi-Anechoic Chamber Frequency Below 1GHz Frequency Above 1GHz APPENDIX A-Page 3 of 3 AUDIX Technology Corp. Tel: +886 2 26099301 No. 53-11, Dingfu, Linkou, Dist., Fax: +886 2 26099303 New Taipei City244, Taiwan File Number: C1M1508198 Report Number: EM-F150636 This test report may be reproduced in full only. The document may only be updated by AUDIX Technology Corp. personnel Any changes will be noted in the Document History section of the report. A.3 RF Conducted Measurement
No. 53-11, Dingfu, Linkou Dist., · New Taipei City · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 18.10 mW |

Ceiling Fan Remote Controller(Transmitter)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Ceiling Fan Remote Controller (Transmitter)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Ceiling Fan Remote Controller (Transmitter)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Ceiling Fan Remote Controller (Transmitter)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
CEILING FAN REMOTE CONTROLLER (TRANSMITTER)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter