FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. APTIV Services US LLC/
  3. L2C0089TR

L2C0089TRFO3-TR903BDA

APTIV Services US LLC
FO3-TR903BDA - FCC ID L2C0089TR - APTIV Services US LLC
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jun 05, 2023
Application Purpose
Original Equipment
Date of Application
May 31, 2023
Equipment Note
FO3-TR903BDA
Frequency Range
902.37500000 - 903.42500000
Company
APTIV Services US LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

5725 Innovation Drive, Troy, Michigan USA 48098 The device under test is manufactured by the grantee (APTIV Services US LLC), and sold as an OEM product. Per 47 CFR 2.909, 2.927, 2.931, 2.1033, etc..., the grantee must ensure the end-user has all applicable / appropriate operating instructions. When end-user instructions are required, as in the case of this product, the grantee must notify the OEM to notify the end-user. APTIV Services US LLC will supply this document to the reseller/distributor dictating what must be included in the end user’s manual for the commercial product. INFORMATION TO BE INCLUDED IN THE END USER’S MANUAL The following information (in blue) must be included in the end-product user’s manual to ensure continued FCC and Industry Canada regulatory compliance. The ID numbers must be included in the manual if the device label is not readily accessible to the end user. The compliance paragraphs below must be included in the user's manual. ****************************************************************************** FCC ID: L2C0089TR IC: 3432A-0089TR This device complies with Part 15 of the FCC Rules and with ISED Canada license-exempt RSSs. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'ISDE Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : 1. L’appareil ne doit pas produire de brouillage; 2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Note: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Attestation Statements

5 Hanover Quay | Grand Canal | Dublin 2 | Ireland Certification Application Attestation Statements Re: FCC ID: L2C0089TR To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) APTIV Services US LLC certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) APTIV Services US LLC (“the applicant”) certifies that, as of the date of the filing of this application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Dated: 24 May 2023 By: ___________ _____________ __ (Signature) Brian W. Johnson Title: Engineering Group Manager E-mail: [email protected] On behalf of: APTIV Services US LLC 13085 Hamilton Crossing Blvd Carmel, Indiana, 46032 United States of America Telephone: +1 765 867 4179 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist .

Attestation Statements

5 Hanover Quay | Grand Canal | Dublin 2 | Ireland ATTENTION: FCC Certification – Section 2.911(d)(7) Information Re: FCC ID: L2C0089TR Applicant and Designated U.S. Agent Company Name: APTIV Services US LLC Grantee Code: L2C FCC Registration Number: 0025770405 Contact Name: Brian W. Johnson Street Address: 13085 Hamilton Crossing Blvd City, State, Zip, Country: Carmel, Indiana, 46032, United States of America Telephone Number: 765-867-4179 E-mail: [email protected] This letter is to confirm that we (“designate[d] agent located in the United States”) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted above. The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Dated: 24 May 2023 By: ___________ _____________ __ (Signature) Brian W. Johnson Title: Engineering Group Manager E-mail: [email protected] On behalf of: APTIV Services US LLC 13085 Hamilton Crossing Blvd Carmel, Indiana, 46032 United States of America Telephone: +1 765 867 4179

Cover Letter(s)

Willow Run (WR) Test Labs, Inc. 7117 Fieldcrest Dr., Brighton, Michigan 48116 USA Tel: (734) 252-9785, Fax: (734) 926-9785, e-mail: [email protected] Attn.:Certification and Engineering Bureau, Innovation, Science and Economic Development Canada 3701 Carling Avenue, Bldg. 94 Ottawa, Ontario K2H 8S2 Re: Certification for Aptiv Services US, LLC FO3-TR903BDA IC: 3432A-0089TR If necessary, we have enclosed application materials for certification of Aptiv Services US, LLC FO3-TR903BDA. It has been verified to comply with IC RSS-210/GENe. Current Variants: There is only a single variant of the EUT, as tested. If there are any questions regarding the application or testing performed, please contact us at the above address or call (734) 252-9785, or e-mail [email protected]. Sincerely, Joseph D. Brunett Willow Run (WR) Test Labs, Inc. Willow Run (WR) Test Labs, Inc. 7117 Fieldcrest Dr., Brighton, Michigan 48116 USA Tel: (734) 252-9785, Fax: (734) 926-9785, e-mail: [email protected] Attn.:Federal Communications Commission Equipment Approval Services P.O. Box 358315 Pittsburgh, PA 15251-5315 Re: Certification for Aptiv Services US, LLC FO3-TR903BDA FCC ID: L2C0089TR If necessary, we have enclosed application materials for certification of Aptiv Services US, LLC FO3-TR903BDA. It has been verified to comply with CFR Title 47, Part 15.231. Current Variants: There is only a single variant of the EUT, as tested. If there are any questions regarding the application or testing performed, please contact us at the above address or call (734) 252-9785, or e-mail [email protected]. Sincerely, Joseph D. Brunett Willow Run (WR) Test Labs, Inc.

Cover Letter(s)

Willow Run (WR) Test Labs, Inc. 7117 Fieldcrest Dr., Brighton, Michigan 48116 USA Tel: (734) 252-9785, Fax: (734) 926-9785, e-mail: [email protected] Re: Certification for Aptiv Services US, LLC FCC ID: L2C0089TR IC: 3432A-0089TR REQUEST FOR CONFIDENTIALITY Pursuant to USA FCC 47 CFR 0.457(d) and 0.459 and Canada IC RSP-100, Section 10, Aptiv Services US, LLC requests that a part of the subject application be held confidential. Aptiv Services US, LLC has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to ”competition” would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. ExhibitConf. TypeRational Exh 04 - Block DiagramPermanentIncludes proprietary internal oscillator frequency information. Exh 05 - SchematicsPermanentIncludes proprietary design information Exh 10 - BOM + PlacementPermanentIncludes proprietary design information Exh 12 - Operating DescriptionPermanentIncludes proprietary information Long Term Confidentiality (Permanent):Aptiv Services US, LLC requests that any exhibits listed above as permanently confidential be permanently withheld from public review. Wherein Long Term Confidentiality is not an option for specific exhibits with ISED, this request applies only to the FCC application for those exhibits. Short-Term Confidentiality (FCC Only):Aptiv Services US, LLC requests that any exhibits selected above as short term confidential be withheld from public view for a period of days (noted above) from the date of the Grant of Equipment Authorization and prior to marketing. If there are any questions regarding the application or testing performed, please contact us at the above address or call (734) 252-9785, or e-mail [email protected]. Sincerely, Joseph D. Brunett Willow Run (WR) Test Labs, Inc.

Cover Letter(s)

5 Hanover Quay | Grand Canal | Dublin 2 | Ireland To Whom It May Concern: Authority to Act as Agent Re: FCC ID: L2C0089TR, IC: 3432A-0089TR We appoint Joseph D. Brunett on behalf of Willow Run Test Labs, Inc. and Amber Helm Development, LC and Bradley J. Koski on behalf of Wireless Approval Consultants to act as our agent(s) in the preparation of this application for equipment certification and/or EU/UKCA Notified Body type examination. We certify that submitted documents properly describe the device or system for which equipment certification is sought. We also certify that each unit manufactured, imported, or marketed (as defined in Industry Canada’s regulations) will have affixed to it a label identical to that submitted for approval with this application. Further, in accordance with section 6.5 of IC CB-02, we hereby acknowledge that our company’s product cannot be distributed, leased, or offered for sale in Canada until it’s listed on the Industry Canada Radio Equipment List (REL). For instances where our authorized agent signs the application for certification on our behalf, we acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by American Certification Body, Inc. and/or TUV Rheinland Group and/or Vista Laboratories, Inc. still resides with APTIV Services US LLC. For TCB applications, we certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) regarding certified equipment. Dated: 24 May 2023 By: ___________ _____________ __ (Signature) Brian W. Johnson Title: Engineering Group Manager E-mail: [email protected] On behalf of: APTIV Services US LLC 13085 Hamilton Crossing Blvd Carmel, Indiana, 46032 United States of America Telephone: +1 765 867 4179

ID Label/Location Info

ď‚· Label Location

RF Exposure Info

Willow Run (WR) Test Labs, Inc. 7117 Fieldcrest Drive Brighton, MI 48116 Phone: (734) 252-9785, Fax (734) 926-9785 e-mail:[email protected] RF EXPOSURE CALCULATIONS Summary: The EUT with all transmitters is compliant with both the FCC power density limit and the ISED Exposure Evaluation limits. Requirement: According to USA CFR 15 §1.1307 (b )(1 ), s ystems operating under the provisions of this section shall be operated in a manner that ensures the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. For Canada, RSS-102 sets out the requirements and measurement techniques used to evaluate radio frequency (RF) exposure compliance of radiocommunication apparatus designed to be used within the vicinity of the human body.

Test Report

Amber Helm Development L.C. 92723 Michigan Hwy-152 Sister Lakes, Michigan 49047 USA Tel: 888-847-8027 APRT9-WR2313TX Issued:May 30, 2023 Electromagnetic Emissions regarding USA: CFR Title 47, Part 15.231(Emissions) Canada:IC RSS-210/GENe(Emissions) for FO3-TR903BDA Category: Transceiver Judgments: 15.231 / RSS-210v10 Compliant Testing Completed: May 29, 2023 TESTING NVLAP LAB CODE 200129-0 Prepared for: Aptiv Services US, LLC 13085 Hamilton Crossing Blvd, Carmel Indiana 46032 USA Phone: 765 451 5770, Fax: 765-451-0900 Contact: Brian Johnson, [email protected] Data Rec./Rev. by:Rpt. Auth. by: John NantzDr. Joseph Brunett, EMC-002790-NE Rpt. Prep./Rev. by:Date of Issue:May 30, 2023 Dr. Joseph Brunett, EMC-002790-NE A copy of this report will remain on file until June 2033.Page 1 of 17 Date: May 30, 2023Prepared For: Aptiv Services US, LLCReport No.: APRT9-WR2313TX Revision History Rev. No.DateDetailsRevised By r0May 30, 2023Initial Release.J. Brunett r1May 31, 2023Corr. harm table.J. Brunett r2June 6, 2023Corr. model + bw typos.J. Brunett Contents Revision History2 Table of Contents2 1 Test Report Scope and Limitations4 1.1 Laboratory Authorization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.2 Report Retention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.3 Subcontracted Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.4 Test Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.5 Limitation of Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.6 Copyright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.7 Endorsements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.8 Test Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 1.9 Traceability and Equipment Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 2 Test Specifications and Procedures6 2.1 Test Specification and General Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 3 Configuration and Identification of the Equipment Under Test7 3.1 Description and Declarations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 3.1.1EUT Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.2Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.3Variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.4Test Samples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.5Functional Exerciser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.6Modifications Made . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.7Production Intent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.8Declared Exemptions and Additional Product Notes . . . . . . . . . . . . . . . . . . . . . . . .9 4 Emissions10 4.1 General Test Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 4.1.1Radiated Test Setup and Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 4.1.2Conducted Emissions Test Setup and Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4.1.3Power Supply Variation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4.2 Intentional Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 4.2.1Fundamental Emission Pulsed Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 4.2.2Fundamental Emission Bandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 4.2.3Fundamental Emission Field Strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 4.3 Unintentional Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4.3.1Transmit Chain Spurious Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5 Measurement Uncertainty and Accreditation Documents17 Amber Helm Development L.C., 92723 Michigan Hwy-152, Sister Lakes, Michigan 49047 USAPage 2 of 17 Date: May 30, 2023Prepared For: Aptiv Services US, LLCReport No.: APRT9-WR2313TX List of Tables 1Test Site List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 2Equipment List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3EUT Declarations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 4Fundamental Emission Pulsed Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 5Fundamental Emission Bandwidth.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 6Fundamental Emission Field Strength.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 7Transmit Chain Spurious Emissions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 8Measurement Uncertainty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 List of Figures 1Photos of EUT.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 2EUT Test Configuration Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3Radiated Emissions Diagram of the EUT. . . . . . . . . . . . . . …

Text truncated - open the document above for the full version.

Test Report

ANT1 && ANT2 && ANT3 (FO3-TR903BDA) Overview: [Dimensions in mm] ANT2 – HB – SUB ANT1 – LB ANT3 – HB – MAIN

Contact Information

Applicant

Brian W Johnson(Engineering Group Manager)
[email protected]765-867-4179Fax: 765-867-5485

Technical Contact

Willow Run (WR) Test Labs, Inc.Joseph D Brunett
[email protected]7342529785

7117 Fieldcrest Dr · Brighton · United States

Non-Technical Contact

Willow Run (WR) Test Labs, Inc.Joseph D Brunett
[email protected]7342529785

Test Firm

AHD (Amber Helm Development, L.C.)Gordon Helm
[email protected]269-429-8352Fax: 269-429-9016

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231902.375 MHz - 903.425 MHz-
Confidentiality
Long Term

Other Applications from APTIV Services US LLC

L2CSRR6PS

SRR6PS

Apr 09, 2024

Equipment Class

VRD - Part 95 Vehicular Radar Systems
L2C0093TR

Wireless Charging Module

Mar 12, 2024

Equipment Class

8CC - Part 18 Consumer Device
Passive entry Keyless Go with tire pressure and door handle monitoring radio frequency module - FCC ID L2C0090TR - APTIV Services US LLC
L2C0090TR

Passive entry Keyless Go with tire pressure and door handle monitoring radio frequency module

Oct 04, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Power Transfer Charger - FCC ID L2C0084TR - APTIV Services US LLC
L2C0084TR

Wireless Power Transfer Charger

Jul 27, 2021

Equipment Class

8CC - Part 18 Consumer Device
DEA700 Series ROW - FCC ID L2C0078TR - APTIV Services US LLC
L2C0078TR

DEA700 Series ROW

Oct 07, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter