Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
NOTE: This equipment has been tested and found to comply with the limits for aNOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits areClass B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in adesigned to provide reasonable protection against harmful interference in adesigned to provide reasonable protection against harmful interference in adesigned to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radioresidential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However,instructions, may cause harmful interference to radio communications. However,instructions, may cause harmful interference to radio communications. However,instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is which can be determined by turning the equipment off and on, the user is which can be determined by turning the equipment off and on, the user is which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:encouraged to try to correct the interference by one or more of the following measures: - - Reorient or relocate the receiving antenna.- - Reorient or relocate the receiving antenna. - - Increase the separation between the equipment and receiver.- - Increase the separation between the equipment and receiver. - - Connect the equipment into an outlet on a circuit different from that to which- - Connect the equipment into an outlet on a circuit different from that to which- - Connect the equipment into an outlet on a circuit different from that to which- - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.the receiver is connected. - - Consult the dealer or an experienced radio/TV technician for help.- - Consult the dealer or an experienced radio/TV technician for help. REMARK: Modifications not authorized by the manufacturer may void usersREMARK: Modifications not authorized by the manufacturer may void users authority to operate this device.authority to operate this device.
To: [email protected] Cc: [email protected] Subject: FCC ID:L5C0762TX Ansen Electronics Hi Alice, I see that Chris granted this today. Congratulations. I have a favor to ask. I realize that I neglected to pick up on the lack of a 15.105 statement in the users manual. Eventhough the Grant has already been issued, so that either one of us does not have any future problems with the FCC, could you request Ansen to resubmit a revised manual page showing the addition of that statement? It would just be better for all involved if they would. Thank you, and again, I apologize for my oversight. I won't be back at work until Monday Dec 3, but I will check with you then on this. Thanks again, and have a good week. Regards, Mariannne
FCC ID: L5C0762TX PHOTOGRAPH OF THE PRODUCT FRONT VIEW OF THE PRODUCT REAR VIEW OF THE PRODUCT
TX
FCC ID: L5C0762TX LABEL LOCATION BOTTOM VIEW OF THE DEVICE WITH FCC ID LABEL
FCC ID: L5C0762TX PHOTOGRAPH OF THE PRODUCT INNER CIRCUIT TOP VIEW INNER CIRCUIT BOTTOM VIEW
FCC ID: L5C0762TX Circuit Description The 434MHz crystal oscillator drives the base of Q2 the final/buffer amplifier. The modulation provided by Mic. The output of Q2 has the matching network consisting of L6 and C8 that limit the harmonic content and effect the proper coupling of the antenna to the output stage. Antenna, Ground and Power Source There is no external Ant. Build in on the Printed Circuit Board. There is no external ground connection. The ground is only that of the printed circuit board. Electric current is supplied by a 3 Volt (“AA” size battery x 2) primary battery
Date: 2001-11-17 TEST REPORT Page 1of 23 No.: HM106251 FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER TEST REPORT No.:HM106251 Equipment Under Test [EUT]:RF Wireless Thermometer Model Number:0762 Applicant:Ansen Electronics Company FCC ID :L5C0762TX Date: 2001-11-17 TEST REPORT Page 2of 23 No.: HM106251 CONTENT: Cover Page 1 of 23 Content Page 2-3 of 23 Conclusion Page 4 of 23 1.0General Details 1.1Test Laboratory Page 5 of 23 1.2Applicant Details Page 5 of 23 Applicant HKSTC Code Number for Applicant Manufacturer 1.3Equipment Under Test [EUT] Page 6 of 23 Description of EUT operation 1.4Date of Order Page 6 of 23 1.5Submitted Sample Page 6 of 23 1.6Test Duration Page 6 of 23 1.7Country of Origin Page 6 of 23 1.8 Additional Information of EUT Page 7 of 23 2.0Technical Details 2.1Investigations Requested Page 8 of 23 2.2Test Standards and Results Summary Page 8 of 23 3.0Test Results 3.1Emission Page 9-14 of 23 3.2Bandwidth Measurement Page 15-16 of 23 Date: 2001-11-17 TEST REPORT Page 3of 23 No.: HM106251 Appendix A List of Measurement Equipment Page 17 of 23 Appendix B Duty Cycle Correction During 100 msec Page 18-19 of 23 Appendix C Periodic Operation Page 20-21 of 23 Appendix D Photographs Page 22-23 of 23 Date: 2001-11-17 TEST REPORT Page 4of 23 No.: HM106251 CONCLUSION The submitted product was deemed to have COMPLIED with the requirements of Federal Communications Commission [FCC] Rules and Regulations Part 15. The tests were performed in accordance with the standards described above and on Section 2.2 in this Test Report. Verify byPatrick Wong for Chief Executive Date: 2001-11-17 TEST REPORT Page 5of 23 No.: HM106251 1.0General Details 1.1Test Laboratory The Hong Kong Standards and Testing Centre Ltd. EMC Laboratory 10 Dai Wang Street, Taipo Industrial Estate New Territories, Hong Kong Telephone:852 2666 1888 Fax:852 2664 4353 1.2Applicant Details Applicant Ansen Electronics Company. Room 78,2/F.,Sino Industrial Plaza, 9 Kai Cheung Road, Kowloon Bay, Kowloon, Hong Kong Telephone:852 27959473 Fax:852 27516577 HKSTC Code Number for ApplicantANE001 Manufacturer Ansen Electronics Company. Room 78,2/F.,Sino Industrial Plaza, 9 Kai Cheung Road, Kowloon Bay, Kowloon, Hong Kong Telephone:852 27959473 Fax:852 27516577 Date: 2001-11-17 TEST REPORT Page 6of 23 No.: HM106251 1.3Equipment Under Test [EUT] Description of Sample Product:RF Wireless Thermometer Manufacturer:Ansen Electronics Company. Brand Name:N/A Model Number:0762 Input Voltage:3Vd.c (“AAA” size battery x 2) Additional Model Number:GE5805WS1 1.3.1Description of EUT Operation The Equipment Under Test (EUT) is an Ansen Electronics Company, 433.05MHz RF wireless thermometer. The transmitter is an automatic transmitter. The EUT is to transmit RF signal while temperature measurement is changed. The EUT is for data transmission, Modulation by Data Code. Tape is pulses modulation. 1.4Date of Order 2001-11-07 1.5Submitted Sample(s): 1 Sample per model 1.6Test Duration 2001-11-14 1.7Country of Origin China Date: 2001-11-17 TEST REPORT Page 7of 23 No.: HM106251 1.8Additional Information of EUT SubmittedNot Available User Manual Part List Circuit Diagram Printed Circuit Board [PCB] Layout Rating Label Block diagram FCC ID Label Date: 2001-11-17 TEST REPORT Page 8of 23 No.: HM106251 2.0Technical Details 2.1Investigations Requested Perform ElectroMagnetic Interference measurement in accordance with FCC 47CFR [Codes of Federal Regulations] Part 15 and ANSI C63.4:2000 for FCC Certification. 2.2Test Standards and Results Summary Tables EMISSION Results Summary Test ConditionTest RequirementTest MethodClass /Test Result SeverityPassFailedN/A Field Strength of Fundamental Emissions & Spurious Emissions FCC 47CFR 15.231eANSI C63.4:2000N/A Radiated Emissions, 30MHz to 1GHz FCC 47CFR 15.209ANSI C63.4:2000Class B Conducted Emissions on AC, 0.45MHz to 30MHz FCC 47CFR 15.207ANSI C63.4:2000Class B Note: N/A - Not Applicable Date: 2001-11-17 TEST REPORT Page 9of 23 No.: HM106251 3.0Test Results 3.1Emission 3.1.1Radiated Emissions Test Requirement:FCC 47CFR 15.231e Test Method:ANSI C63.4:2000 Test Date:2001-11-14 Mode of Operation:On mode Test Method: The sample was placed 0.8m above the ground plane on the OATS *. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigate all operating modes, rotated about all 3 axis (X, Y & Z) to obtain worst position, manipulating interconnecting cables, rotating turntable, varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown in Test Results of the following pages. *:OATS [Open Area Test Site] located at HKSTC with a metal ground plane on filed with the FCC pursuant to section 2.948 of the FCC rules, with Registration Number: 90657. Test Setup: Date: 2001-11-17 TEST REPORT Page 10of 23 No.: HM106251 Limits for Field Strength of Fundamental Emissions [FCC 47CFR 15.231e]: Frequency Range of Fundamental Field Strength of Fundamental Emissions Field Strength of Spurious Emissions [MHz] [μV/m][μV/m] 40.66-40.701,000100 70-13050050 130-174500 to 1,500 *50 to 150 * 174-2601,500150 260-4701,500 to 5,000 *150 to 500 * Above 4705,000500 Where F is the frequency in MHz, the formula for calculating the maximum permitted fundamental field strengths are as follows: for the band 130-174 MHz, ìV/m at meters=22.72727(F)-2454.545; for the band 260-470 MHz, ìV/m at 3 meters =16.6667(F)-2833.3333. The maximum permissible unwanted emission level is 20dB below the maximum fundamental level. Results: Field Strength of Fundamental Emissions Peak Value Frequency Level @3m Correction Factor Field Strength Field Strength Limit ** @3m Antenna Polarity MHz dBμV dB/m dBμV/mμV/mμV/m 434.0556.722.479.19015.7144008.48Vertical 868.1029.734.564.21621.814400.85Horizontal According to FCC 47CFR15.35, the limit on the radio frequency emissions as measured using…
Text truncated - open the document above for the full version.
FCC ID: L5C0762TX TEST SET UP PHOTOGRAPH OF THE PRODUCT MEASUREMENT OF RADIATED EMISSION TEST SET UP
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231(e) | 434 MHz - 434 MHz | - |

Stereo Diamond Bluetooth Speaker/Stereo Powerball
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Candle Light Speaker
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterBONE BLUETOOTH SPEAKER
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterX-CONCEPT BLUETOOTH SPEAKER
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterCandle Bluetooth Speaker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter