Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
GETTING STARTED GUIDE Cisco Aironet 2600 Series Lightweight Access Points 1About this Guide 2Introduction to the Access Point 3Safety Instructions 4Unpacking 5Configurations 6Access Point Ports and Connectors 7Configuring the Access Point 8Mounting the Access Point 9Deploying the Access Point on the Wireless Network 10Troubleshooting 11Declarations of Conformity and Regulatory Information 12Configuring DHCP Option 43 and DHCP Option 60 13Access Point Specifications ap2600getstart.fm Page 1 Wednesday, February 1, 2012 3:58 PM 2 1 About this Guide This Guide provides instructions on how to install and configure your Cisco Aironet 2600 Series Access Point. This guide also provides mounting instructions and limited troubleshooting procedures. The 2600 Series Access Point is referred to as the access point in this document. 2 Introduction to the Access Point The 2600 series supports high-performing Spectrum Intelligence which sustains three spatial stream rates over a deployable distance with high reliability when serving clients. The 2600 series provides high reliability and overall wireless performance. The 2600 series offers dual-band radios (2.4 GHz and 5 GHz) with integrated and external antenna options. The access points support full inter-operability with leading 802.11n clients, and support a mixed deployment with other access points and controllers. The 2600 series access point is a controller-based (Unified) product and supports: •Simultaneous dual-band (2.4 GHz/5 GHz) radios •Integrated antennas on the 2601I and 2602I access point models (AIR-CAP2601I-x-K9 and AIR-CAP2602I-x-K9) •External antennas for rugged 2601E and 2602E access point models (AIR-CAP2601E-x-K9AIR-CAP2602E-x-K9) NoteThe ‘x’ in the model numbers represents the regulatory domain. Refer to “Regulatory Domains” section on page 6 for a list of supported regulatory domains. The features of the 2600 series are: •Processing sub-systems (including CPUs and memory) and radio hardware which supports: –Network management –CleanAir—Automatic detection, classification, location and mitigation of RF interference (not available on autonomous or standalone models) –ClientLink+—BeamForming to 802.11n clients as well as legacy 802.11a/g OFDM clients –VideoStream –Location –WIDS/WIPS –Security –Radio Resource Management (RRM) ap2600getstart.fm Page 2 Wednesday, February 1, 2012 3:58 PM 3 –Rogue detection –Management Frame Protection (MFP) –Throughput, forwarding, and filtering performance scaled to meet 3 spatial stream 450 Mbps data-rates •32 MB flash size •802.11af/at –CDP (Cisco Discovery Protocol) •2.4 GHz and 5 GHz 802.11n radios with the following features: –4TX x 4RX –3-spatial streams, 450 Mbps PHY rate –Spectrum intelligence –DPD (Digital Pre-Distortion) technology –Cisco Vector Beamforming—Implicit Co-phase beamforming for .11ag clients and 1x1 11n clients –Radio hardware is capable of explicit compressed beamforming (ECBF) per 802.11n standard 3 Safety Instructions Translated versions of the following safety warnings are provided in the translated safety warnings document that is shipped with your access point. The translated warnings are also in the Translated Safety Warnings for Cisco Aironet Access Points, which is available on Cisco.com. WarningIMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071 SAVE THESE INSTRUCTIONS WarningRead the installation instructions before you connect the system to its power source. Statement 1004 ap2600getstart.fm Page 3 Wednesday, February 1, 2012 3:58 PM 4 WarningInstallation of the equipment must comply with local and national electrical codes. Statement 1074 WarningThis product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 20A. Statement 1005 WarningDo not operate your wireless network device near unshielded blasting caps or in an explosive environment unless the device has been modified to be especially qualified for such use. Statement 245B WarningIn order to comply with FCC radio frequency (RF) exposure limits, antennas should be located at a minimum of 7.9 inches (20 cm) or more from the body of all persons. Statement 332 CautionThe fasteners you use to mount an access point on a ceiling must be capable of maintaining a minimum pullout force of 20 lbs (9 kg) and must use all 4 indented holes on the mounting bracket. CautionThis product and all interconnected equipment must be installed indoors within the same building, including the associated LAN connections as defined by Environment A of the IEEE 802.af Standard. NoteThe access point is suitable for use in environmental air space in accordance with section 300.22.C of the National Electrical Code and sections 2-128, 12-010(3), and 12-100 of the Canadian Electrical Code, Part 1, C22.1. You should not install the power supply or power injector in air handling spaces. NoteUse only with listed ITE equipment. ap2600getstart.fm Page 4 Wednesday, February 1, 2012 3:58 PM 5 4 Unpacking To unpack the access point, follow these steps: Step 1Unpack and remove the access point and the accessory kit from the shipping box. Step 2Return any packing material to the shipping container and save it for future use. Step 3Verify that you have received the items listed below. If any item is missing or damaged, contact your Cisco representative or reseller for instructions. –The access point –Mounting bracket (selected when you ordered the access point) –Adjustable ceiling-rail clip (selected when you ordered the access point) 5 Configurations The 2600 series acce…
Text truncated - open the document above for the full version.
GETTING STARTED GUIDE Cisco Aironet 2600 Series Lightweight Access Points 1About this Guide 2Introduction to the Access Point 3Safety Instructions 4Unpacking 5Configurations 6Access Point Ports and Connectors 7Configuring the Access Point 8Mounting the Access Point 9Deploying the Access Point on the Wireless Network 10Troubleshooting 11Declarations of Conformity and Regulatory Information 12Configuring DHCP Option 43 and DHCP Option 60 13Access Point Specifications ap2600getstart.fm Page 1 Wednesday, February 1, 2012 3:58 PM 2 1 About this Guide This Guide provides instructions on how to install and configure your Cisco Aironet 2600 Series Access Point. This guide also provides mounting instructions and limited troubleshooting procedures. The 2600 Series Access Point is referred to as the access point in this document. 2 Introduction to the Access Point The 2600 series supports high-performing Spectrum Intelligence which sustains three spatial stream rates over a deployable distance with high reliability when serving clients. The 2600 series provides high reliability and overall wireless performance. The 2600 series offers dual-band radios (2.4 GHz and 5 GHz) with integrated and external antenna options. The access points support full inter-operability with leading 802.11n clients, and support a mixed deployment with other access points and controllers. The 2600 series access point is a controller-based (Unified) product and supports: •Simultaneous dual-band (2.4 GHz/5 GHz) radios •Integrated antennas on the 2601I and 2602I access point models (AIR-CAP2601I-x-K9 and AIR-CAP2602I-x-K9) •External antennas for rugged 2601E and 2602E access point models (AIR-CAP2601E-x-K9AIR-CAP2602E-x-K9) NoteThe ‘x’ in the model numbers represents the regulatory domain. Refer to “Regulatory Domains” section on page 6 for a list of supported regulatory domains. The features of the 2600 series are: •Processing sub-systems (including CPUs and memory) and radio hardware which supports: –Network management –CleanAir—Automatic detection, classification, location and mitigation of RF interference (not available on autonomous or standalone models) –ClientLink+—BeamForming to 802.11n clients as well as legacy 802.11a/g OFDM clients –VideoStream –Location –WIDS/WIPS –Security –Radio Resource Management (RRM) ap2600getstart.fm Page 2 Wednesday, February 1, 2012 3:58 PM 3 –Rogue detection –Management Frame Protection (MFP) –Throughput, forwarding, and filtering performance scaled to meet 3 spatial stream 450 Mbps data-rates •32 MB flash size •802.11af/at –CDP (Cisco Discovery Protocol) •2.4 GHz and 5 GHz 802.11n radios with the following features: –4TX x 4RX –3-spatial streams, 450 Mbps PHY rate –Spectrum intelligence –DPD (Digital Pre-Distortion) technology –Cisco Vector Beamforming—Implicit Co-phase beamforming for .11ag clients and 1x1 11n clients –Radio hardware is capable of explicit compressed beamforming (ECBF) per 802.11n standard 3 Safety Instructions Translated versions of the following safety warnings are provided in the translated safety warnings document that is shipped with your access point. The translated warnings are also in the Translated Safety Warnings for Cisco Aironet Access Points, which is available on Cisco.com. WarningIMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071 SAVE THESE INSTRUCTIONS WarningRead the installation instructions before you connect the system to its power source. Statement 1004 ap2600getstart.fm Page 3 Wednesday, February 1, 2012 3:58 PM 4 WarningInstallation of the equipment must comply with local and national electrical codes. Statement 1074 WarningThis product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 20A. Statement 1005 WarningDo not operate your wireless network device near unshielded blasting caps or in an explosive environment unless the device has been modified to be especially qualified for such use. Statement 245B WarningIn order to comply with FCC radio frequency (RF) exposure limits, antennas should be located at a minimum of 7.9 inches (20 cm) or more from the body of all persons. Statement 332 CautionThe fasteners you use to mount an access point on a ceiling must be capable of maintaining a minimum pullout force of 20 lbs (9 kg) and must use all 4 indented holes on the mounting bracket. CautionThis product and all interconnected equipment must be installed indoors within the same building, including the associated LAN connections as defined by Environment A of the IEEE 802.af Standard. NoteThe access point is suitable for use in environmental air space in accordance with section 300.22.C of the National Electrical Code and sections 2-128, 12-010(3), and 12-100 of the Canadian Electrical Code, Part 1, C22.1. You should not install the power supply or power injector in air handling spaces. NoteUse only with listed ITE equipment. ap2600getstart.fm Page 4 Wednesday, February 1, 2012 3:58 PM 5 4 Unpacking To unpack the access point, follow these steps: Step 1Unpack and remove the access point and the accessory kit from the shipping box. Step 2Return any packing material to the shipping container and save it for future use. Step 3Verify that you have received the items listed below. If any item is missing or damaged, contact your Cisco representative or reseller for instructions. –The access point –Mounting bracket (selected when you ordered the access point) –Adjustable ceiling-rail clip (selected when you ordered the access point) 5 Configurations The 2600 series acce…
Text truncated - open the document above for the full version.
GETTING STARTED GUIDE Cisco Aironet 2600 Series Access Points 1About this Guide 2Introduction to the Access Point 3Safety Instructions 4Unpacking 5Configurations 6Access Point Ports and Connectors 7Configuring the Access Point 8Mounting the Access Point 9Deploying the Access Point on the Wireless Network 10Troubleshooting 11Declarations of Conformity and Regulatory Information 12Configuring DHCP Option 43 and DHCP Option 60 13Access Point Specifications ap2600getstart.fm Page 1 Wednesday, April 11, 2012 10:00 AM 2 1 About this Guide This Guide provides instructions on how to install and configure your Cisco Aironet 2600 Series Access Point. This guide also provides mounting instructions and limited troubleshooting procedures. The 2600 Series Access Point is referred to as the 2600 series or the access point in this document. 2 Introduction to the Access Point The 2600 series supports high-performing Spectrum Intelligence which sustains three spatial stream rates over a deployable distance with high reliability when serving clients. The 2600 series provides high reliability and overall wireless performance. The 2600 series offers both single-band radios (2.4 GHz in 2601 models) and dual-band radios (2.4 GHz and 5 GHz in 2602 models) with integrated and external antenna options. The access points support full inter-operability with leading 802.11n clients, and support a mixed deployment with other access points and controllers. The 2600 series access point is available in both controller-based (Unified) and standalone (Autonomous) configurations and supports: •Simultaneous single-band or dual-band (2.4 GHz/5 GHz) radios •Integrated antennas on the 2601I and 2602I access point models (AIR-CAP2601I-x-K9 and AIR-CAP2602I-x-K9) •External antennas for rugged 2601E and 2602E access point models (AIR-CAP2601E-x-K9 and AIR-CAP2602E-x-K9) NoteThe ‘x’ in the model numbers represents the regulatory domain. Refer to “Regulatory Domains” section on page 7 for a list of supported regulatory domains. The features of the 2600 series are: •Processing sub-systems (including CPUs and memory) and radio hardware which supports: –Network management –CleanAir—Automatic detection, classification, location and mitigation of RF interference (not available on autonomous or standalone models) –ClientLink+—BeamForming to 802.11n clients as well as legacy 802.11a/g OFDM clients –VideoStream –Location –WIDS/WIPS –Security ap2600getstart.fm Page 2 Wednesday, April 11, 2012 10:00 AM 3 –Radio Resource Management (RRM) –Rogue detection –Management Frame Protection (MFP) –Throughput, forwarding, and filtering performance scaled to meet 3 spatial stream 450 Mbps data-rates •32 MB flash size •802.11af/at –CDP (Cisco Discovery Protocol) •2.4 GHz and 5 GHz 802.11n radios with the following features: –4TX x 4RX –3-spatial streams, 450 Mbps PHY rate –Spectrum intelligence –DPD (Digital Pre-Distortion) technology –Cisco Vector Beamforming—Implicit Co-phase beamforming for .11ag clients and 1x1 11n clients –Radio hardware is capable of explicit compressed beamforming (ECBF) per 802.11n standard 3 Safety Instructions Translated versions of the following safety warnings are provided in the translated safety warnings document that is shipped with your access point. The translated warnings are also in the Translated Safety Warnings for Cisco Aironet Access Points, which is available on Cisco.com. WarningIMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071 SAVE THESE INSTRUCTIONS ap2600getstart.fm Page 3 Wednesday, April 11, 2012 10:00 AM 4 WarningRead the installation instructions before you connect the system to its power source. Statement 1004 WarningInstallation of the equipment must comply with local and national electrical codes. Statement 1074 WarningThis product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 20A. Statement 1005 WarningDo not operate your wireless network device near unshielded blasting caps or in an explosive environment unless the device has been modified to be especially qualified for such use. Statement 245B WarningIn order to comply with FCC radio frequency (RF) exposure limits, antennas should be located at a minimum of 7.9 inches (20 cm) or more from the body of all persons. Statement 332 CautionThe fasteners you use to mount an access point on a ceiling must be capable of maintaining a minimum pullout force of 20 lbs (9 kg) and must use all 4 indented holes on the mounting bracket. CautionThis product and all interconnected equipment must be installed indoors within the same building, including the associated LAN connections as defined by Environment A of the IEEE 802.af Standard. ap2600getstart.fm Page 4 Wednesday, April 11, 2012 10:00 AM 5 NoteThe access point is suitable for use in environmental air space in accordance with section 300.22.C of the National Electrical Code and sections 2-128, 12-010(3), and 12-100 of the Canadian Electrical Code, Part 1, C22.1. You should not install the power supply or power injector in air handling spaces. NoteUse only with listed ITE equipment. 4 Unpacking To unpack the access point, follow these steps: Step 1Unpack and remove the access point and the accessory kit from the shipping box. Step 2Return any packing material to the shipping container and save it for future use. Step 3Verify that you have received the items listed below. If any item is missing or damaged, contact your Cisco representative or reseller for instructions. –The access point –Mounting bracket (selected when …
Text truncated - open the document above for the full version.
GETTING STARTED GUIDE Cisco Aironet 2600 Series Access Points 1About this Guide 2Introduction to the Access Point 3Safety Instructions 4Unpacking 5Configurations 6Access Point Ports and Connectors 7Configuring the Access Point 8Mounting the Access Point 9Deploying the Access Point on the Wireless Network 10Troubleshooting 11Declarations of Conformity and Regulatory Information 12Configuring DHCP Option 43 and DHCP Option 60 13Access Point Specifications ap2600getstart.fm Page 1 Tuesday, April 17, 2012 10:39 AM 2 1 About this Guide This Guide provides instructions on how to install and configure your Cisco Aironet 2600 Series Access Point. This guide also provides mounting instructions and limited troubleshooting procedures. The 2600 Series Access Point is referred to as the 2600 series or the access point in this document. 2 Introduction to the Access Point The 2600 series supports high-performing Spectrum Intelligence which sustains three spatial stream rates over a deployable distance with high reliability when serving clients. The 2600 series provides high reliability and overall wireless performance. The 2600 series offers both single-band radios (2.4 GHz in 2601 models) and dual-band radios (2.4 GHz and 5 GHz in 2602 models) with integrated and external antenna options. The access points support full inter-operability with leading 802.11n clients, and support a mixed deployment with other access points and controllers. The 2600 series access point is available in both controller-based (Unified) and standalone (Autonomous) configurations and supports: •Simultaneous single-band or dual-band (2.4 GHz/5 GHz) radios •Integrated antennas on the 2601I and 2602I access point models (AIR-CAP2601I-x-K9 and AIR-CAP2602I-x-K9) •External antennas for rugged 2601E and 2602E access point models (AIR-CAP2601E-x-K9 and AIR-CAP2602E-x-K9) NoteThe ‘x’ in the model numbers represents the regulatory domain. Refer to “Regulatory Domains” section on page 7 for a list of supported regulatory domains. The features of the 2600 series are: •Processing sub-systems (including CPUs and memory) and radio hardware which supports: –Network management –CleanAir—Automatic detection, classification, location and mitigation of RF interference (not available on autonomous or standalone models) –ClientLink+—BeamForming to 802.11n clients as well as legacy 802.11a/g OFDM clients –VideoStream –Location –WIDS/WIPS –Security ap2600getstart.fm Page 2 Tuesday, April 17, 2012 10:39 AM 3 –Radio Resource Management (RRM) –Rogue detection –Management Frame Protection (MFP) –Throughput, forwarding, and filtering performance scaled to meet 3 spatial stream 450 Mbps data-rates •32 MB flash size •802.11af/at –CDP (Cisco Discovery Protocol) •2.4 GHz and 5 GHz 802.11n radios with the following features: –4TX x 4RX –3-spatial streams, 450 Mbps PHY rate –Spectrum intelligence –DPD (Digital Pre-Distortion) technology –Cisco Vector Beamforming—Implicit Co-phase beamforming for .11ag clients and 1x1 11n clients –Radio hardware is capable of explicit compressed beamforming (ECBF) per 802.11n standard 3 Safety Instructions Translated versions of the following safety warnings are provided in the translated safety warnings document that is shipped with your access point. The translated warnings are also in the Translated Safety Warnings for Cisco Aironet Access Points, which is available on Cisco.com. WarningIMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071 SAVE THESE INSTRUCTIONS ap2600getstart.fm Page 3 Tuesday, April 17, 2012 10:39 AM 4 WarningRead the installation instructions before you connect the system to its power source. Statement 1004 WarningInstallation of the equipment must comply with local and national electrical codes. Statement 1074 WarningThis product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 20A. Statement 1005 WarningDo not operate your wireless network device near unshielded blasting caps or in an explosive environment unless the device has been modified to be especially qualified for such use. Statement 245B WarningIn order to comply with FCC radio frequency (RF) exposure limits, antennas should be located at a minimum of 7.9 inches (20 cm) or more from the body of all persons. Statement 332 CautionThe fasteners you use to mount an access point on a ceiling must be capable of maintaining a minimum pullout force of 20 lbs (9 kg) and must use all 4 indented holes on the mounting bracket. CautionThis product and all interconnected equipment must be installed indoors within the same building, including the associated LAN connections as defined by Environment A of the IEEE 802.af Standard. ap2600getstart.fm Page 4 Tuesday, April 17, 2012 10:39 AM 5 NoteThe access point is suitable for use in environmental air space in accordance with section 300.22.C of the National Electrical Code and sections 2-128, 12-010(3), and 12-100 of the Canadian Electrical Code, Part 1, C22.1. You should not install the power supply or power injector in air handling spaces. NoteUse only with listed ITE equipment. 4 Unpacking To unpack the access point, follow these steps: Step 1Unpack and remove the access point and the accessory kit from the shipping box. Step 2Return any packing material to the shipping container and save it for future use. Step 3Verify that you have received the items listed below. If any item is missing or damaged, contact your Cisco representative or reseller for instructions. –The access point –Mounting bracket (selected when you orde…
Text truncated - open the document above for the full version.
Jim Nicholson EMC Compliance Engineer Cisco Systems, Inc. 4125 Highlander Parkway Richfield, OH 44286 Phone: (330) 523-2094 Fax: (330) 523-2002 E-Mail: [email protected] April 3, 2012 Re: FCC ID: LDK102080 Applicant: Cisco Systems Inc Correspondence Reference Number: 41503 Form 731 Confirmation Number: EA217668 Date of Original E-mail: 04/02/2012 1. Please notch out 5600-5650 MHz band on Form 731. The closest usable channels to the notched band in various operation bandwidth modes should be identified on Form 731 frequency listing. Chen, can you update the form to show the following please? I don’t believe I can revise the form once it is completed. 5500-5580 MHz 5660-5700 MHz 2. There seem to be multiple models which will share this FCC ID, for example, 2600E, 2600I, CAP/SAP 2602, 26011, 26021, 2601E, CAP/SAP 2602E have been mentioned in the documents. Please list in operational description (or a separate cover/attestation letter) all models which will be using this FCC ID and their differences, including corresponding antenna types and gains. Attestation statement is necessary to confirm whether or not they are electrically identical. See updated Radio Theory of Operation 3. Expedited DFS review is approved. However, in the future please do not reference a model which in turn references yet another one. Pointing to the right origin would allow us to find necessary information more quickly. Thank you, and I apologize for the confusion. 4. Please move UNII-2 (5250-5350 MHz) and UNII-Worldwide (5470-5725 MHz) EMC reports from DTS filing to the NII filing. There is no need to have the DFS report and UNII-1 EMC report in the DTS filing either, please supersede. We uploaded both in the manner you described on 3/16, and realized the mistake right after filing the DTS application. We, sent an email to FCC on 3/16 to request FCC to remove the UNII reports from DTS app. Chen, would you be able to remove the UNII reports for us in this case? Jim Nicholson EMC Compliance Engineer Cisco Systems, Inc. 4125 Highlander Parkway Richfield, OH 44286 Phone: (330) 523-2094 Fax: (330) 523-2002 E-Mail: [email protected] 5. On Software Theory of Operation: a) The regulatory domain (country code) is said to be dictated by the AP software, more specifically the variable/cookie stored on the CPU's external flash memory. Since the entire content of the NOR flash memory is overwritten after an AP software image upgrade, please describe how protection is achieved to prevent a new country code being installed. The applicant states in the Theory that "It is very difficult to write radio firmware for this system-on-a-chip." However, the applicant did just that for the Marvell 8764C SOC. On the same token, the entire AP software can be replaced by third party software. See the reply to “Question 9” in the updated software Theory of Operation. b) Furthermore, the Theory indicates that when there is a conflict of the domain setting between the AP cookie and the radio firmware TLV, the AP cookie would override the TLV. However, in answer to Question #3, the applicant states that "A single AP software release will cover all hardware SKUs ... permanent domain setting (installed in the radio firmware during manufacturing) are activated in the field" which contradicts the above claim. Please clarify. See the reply to “Question 10” in the updated software Theory of Operation. c) In addition, please elaborate on dynamic memory map (Section 5.0, Software Theory of Operation) which seems to be the main protection mechanism against the country code variable/cookie being altered. See the reply to “Question 11” in the updated software Theory of Operation. d) Finally, the Theory indicates that the regulatory domain is set at "ordering, configuration, and shipping." However, when the shipment has no known end customers, i.e., sold through distributor, web retailer, value-added reseller or system integrator, what would be the entry for the regulatory domain field? What control does the manufacturer have to ensure that the correct country is selected in such cases? See the reply to “Question 12” in the updated software Theory of Operation. Jim Nicholson EMC Compliance Engineer Cisco Systems, Inc. 4125 Highlander Parkway Richfield, OH 44286 Phone: (330) 523-2094 Fax: (330) 523-2002 E-Mail: [email protected] 6. On MPE report: a) Please consistency between maximum powers/antenna gain in the MPE reports and those in the EMC reports. Each maximum power used in the MPE estimate should have an exact source in the EMC peak power measurement table. b) Furthermore, per 2.1091 a mobile device is defined as "generally be used in such a way that a separation distance of at least 20 cm is normally maintained" Therefore, the < 20 cm minimum distances in the User’s Manual (Page 29) and the MPE reports are redundant and/or misleading. Please revise Manual and MPE report. c) Do not include one MPE report in each EMC report as an appendix. There is an exhibit type specifically for RF Exposure for each filing. Only one worst case MPE estimation for all three NII sub-bands is required; and only one MPE report for the two DTS sub-bands. This allows the public to quickly locate RF exposure information. See the new revision of the uploaded User Guide. The distances in the tables have been changed to 20cm. 7. The applicant is reminded that when the fourth transmit antenna is enabled by software upgrade, a Class III Permissive Change may be required if the output power ratings are increased. The test reports reflect all current and future operating modes, so no updates will be required. Best Regards, Jim Nicholson EMC Compliance Engineer
GETTING STARTED GUIDE Cisco Aironet 2600 Series Lightweight Access Points 1About this Guide 2Introduction to the Access Point 3Safety Instructions 4Unpacking 5Configurations 6Access Point Ports and Connectors 7Configuring the Access Point 8Mounting the Access Point 9Deploying the Access Point on the Wireless Network 10Troubles…
Text truncated - open the document above for the full version.
170 West Tasman Drive · San Jose, California · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 4 | 15E | 5.66 GHz - 5.70 GHz | 87.00 mW |

Wireless Phone
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterWi-Fi 6E Outdoor Access Point
Equipment Class
6SD - 15E 6 GHz Standard Power Access PointWi-Fi 6E Outdoor Access Point
Equipment Class
6SD - 15E 6 GHz Standard Power Access PointCisco Headset USB-C Adapter
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterUC Phone
Equipment Class
NII - Unlicensed National Information Infrastructure TX