FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Cisco Systems Inc/
  3. LDK102094

LDK102094Aironet 802.11ac

Cisco Systems Inc

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 12, 2015
Application Purpose
Original Equipment
Date of Application
Sep 14, 2015
Equipment Note
Aironet 802.11ac
Frequency Range
2402.00000000 - 2480.00000000
Company
Cisco Systems Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

External Photos

ID Label/Location Info

Internal Photos

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GETTING STARTED GUIDE Cisco Aironet 3700 Series Access Points 1About this Guide 2Introduction to the Access Point 3Safety Instructions 4Unpacking 5Configurations 6Access Point Ports and Connectors 7Configuring the Access Point 8Mounting the Access Point 9Deploying the Access Point on the Wireless Network 10Installing Modules 11Troubleshooting 12Declarations of Conformity and Regulatory Information 13Configuring DHCP Option 43 and DHCP Option 60 14Access Point Specifications 2 First Published: November, 2013, 78-21474-01 Last Updated: July 10, 2015 3 1 About this Guide This Guide provides instructions on how to install and configure your Cisco Aironet 3700 Series Access Point and how to install available radio modules. This guide also provides mounting instructions and limited troubleshooting procedures. The 3700 Series Access Point is referred to as the access point in this document. 2 Introduction to the Access Point The 3700 series supports high-performing Spectrum Intelligence which sustains three spatial stream rates over a deployable distance with high reliability when serving clients. The 3700 series provides high reliability and overall wireless performance. The 3700 series offers dual-band radios (2.4 GHz and 5 GHz) with integrated and external antenna options. The access points support full inter-operability with leading 802.11ac clients, and support a mixed deployment with other access points and controllers. The 3700 series access point is a controller-based (Unified) product and supports: •Simultaneous dual-band (2.4-GHz and 5-GHz) radios •Integrated antennas on the 3702I access point model (AIR-CAP3702I-x-K9, AIR-AP3702I-UXK9) •External antennas for rugged 3702E access point model (AIR-CAP3702E-x-K9, AIR-AP3702E-UXK9) NoteThe ‘x’ in the model numbers represents the regulatory domain. Model numbers containing -UX, support the universal regulatory domain. For information on supported regulatory domains, see “Regulatory Domains” section on page 7 for a list of supported regulatory domains. The features of the 3700 series are: •Processing sub-systems (including CPUs and memory) and radio hardware which supports: –Network management –CleanAir—Automatic detection, classification, location and mitigation of RF interference –ClientLink 3.0 —BeamForming to 802.11a/g/n/ac clients. –VideoStream –Location –WIDS/WIPS –Security 4 –Radio Resource Management (RRM) –Rogue detection –Management Frame Protection (MFP) –Throughput, forwarding, and filtering performance scaled to meet 3 spatial stream, 1.3-Gbps data-rates •32 MB flash size •802.11af/at –CDP (Cisco Discovery Protocol) •2.4 GHz and 5 GHz 802.11n radios with the following features: –4TX x 4RX –3-spatial streams, 1.3-Gbps PHY rate –Spectrum intelligence –DPD (Digital Pre-Distortion) technology –Cisco Vector Beamforming –Radio hardware is capable of explicit compressed beamforming (ECBF) per 802.11n standard 3 Safety Instructions Translated versions of the following safety warnings are provided in the translated safety warnings document that is shipped with your access point. The translated warnings are also in the Translated Safety Warnings for Cisco Aironet Access Points, which is available on Cisco.com. WarningIMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071 SAVE THESE INSTRUCTIONS WarningRead the installation instructions before you connect the system to its power source. Statement 1004 5 WarningInstallation of the equipment must comply with local and national electrical codes. Statement 1074 WarningThis product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 20A. Statement 1005 WarningDo not operate your wireless network device near unshielded blasting caps or in an explosive environment unless the device has been modified to be especially qualified for such use. Statement 245B WarningIn order to comply with FCC radio frequency (RF) exposure limits, antennas should be located at a minimum of 7.9 inches (20 cm) or more from the body of all persons. Statement 332 CautionThe fasteners you use to mount an access point on a ceiling must be capable of maintaining a minimum pullout force of 20 lbs (9 kg) and must use all 4 indented holes on the mounting bracket. CautionThis product and all interconnected equipment must be installed indoors within the same building, including the associated LAN connections as defined by Environment A of the IEEE 802.af Standard. NoteThe access point is suitable for use in environmental air space in accordance with section 300.22.C of the National Electrical Code and sections 2-128, 12-010(3), and 12-100 of the Canadian Electrical Code, Part 1, C22.1. You should not install the power supply or power injector in air handling spaces. NoteUse only with listed ITE equipment. 6 4 Unpacking To unpack the access point, follow these steps: Step 1Unpack and remove the access point and the accessory kit from the shipping box. Step 2Return any packing material to the shipping container and save it for future use. Step 3Verify that you have received the items listed below. If any item is missing or damaged, contact your Cisco representative or reseller for instructions. –The access point –Mounting bracket (selected when you ordered the access point) –Adjustable ceiling-rail clip (selected when you ordered the access point) 5 Configurations The 3700 series access point contains two simultaneous dual-band radios, the 2.4-GHz MIMO radio and the 5-GHz 802.11ac MIMO radio. The 3700 series access point configurations are: •AIR-CAP3702E-x-K9,…

Text truncated - open the document above for the full version.

RF Exposure Info

Custom EMC Test Report No: EDCS - 1514660 Maximum Permissible Exposure (MPE) Calculations For AIR-RM3010l-B-K9 FCC ID: LDK102094 Also Covers: AIR-AP1572xy-C-K9 AIR-AP1572xy-N-K9 AIR-AP1572xy-S-K9 AIR-AP1572xy-T-K9 AIR-AP1572xy-Z-K9 Data for 5.15-5.25GHz is for –B domain only Testing - Certificate Number: 1178-01 Revision 2 Custom EMC Test Report No: EDCS - 1514660 Devices are subject to the radio frequency radiation exposure requirements specified in Sec. 1.1307(b), Sec. 2.1091 and Sec. 2.1093 of this chapter, as appropriate. All equipment shall be considered to operate in a ``general population/uncontrolled'' environment. Applications for equipment authorization of devices operating under this section must contain a statement confirming compliance with these requirements for both fundamental emissions and unwanted emissions. Technical information showing the basis for this statement must be submitted to the Commission upon request. Given E=√(30*P*G)/d and S=E^2/3770 where E=Field Strength in Volts/meter P=Power in Watts G=Numeric Antenna Gain d=Distance in meters S=Power Density in mW/cm^2 Combine equations and rearrange the terms to express the distance as a function of the remaining variables: d=√((30*P*G)/(3770*S)) Changing to units of power in mW and distance in cm, using: P(mW)=P(W)/1000 d(cm)=100*d(m) yields d=100*√((30*(P/1000)*G)/(3770*S)) d=0.282*√(P*G/S) where d=Distance in cm P=Power in mW G=Numerica Antenna Gain S=Power Density in mW/cm^2 Substituting the logarithmic form of power and gain using: P(mW)=10^(P(dBm)/10) G(numeric)=10^(G(dBi)/10) yields d=0.282*10^((P+G)/20)/√S Equation (1) and s=((0.282*10^((P+G)/20))/d)^2 Equation (2) where d=MPE distance in cm P=Power in dBm G=Antenna Gain in dBi S=Power Density in mW/cm^2 Custom EMC Test Report No: EDCS - 1514660 Equation (1) and the measured peak power are used to calculate the MPE distance. Note that for mobile or fixed location transmitters such as an access point, the minimum separation distance is 20 cm even if the calculations indicate that the MPE distance may be less. S=1mW/cm^2 maximum. Using the peak power levels recorded in the test report along with Equation 1 above, the MPE distances are calculated as follows. To maintain compliance, installations will assure a separation distance of at least 20cm. Using Equation 2, the MPE levels (s) at 20 cm are calculated as follows: (MHz) MPE Distance (cm) Peak Transmit Power (dBm) Power Density (mW/cm^2) Limit Frequency (mW/cm^2) Margin (mW/cm^2) 2437+5785 20 28.04 0.32 1 0.68 Frequency (MHz) Power Density (mW/cm^2) Peak Transmit Power (dBm) Ant enna Gain (dBi) MPE Distance (cm) Limit (cm) Mar gin (cm) 2412121.04 5.01 2014.99 2437126.44 9.34 2010.66 2462123.04 6.31 2013.69 5180122.04 5.63 2014.37 5240123.04 6.31 2013.69 52601224 5.63 2014.37 53201214 5.01 2014.99 55001164 2.82 2017.18 55801224 5.63 2014.37 57201214 5.01 2014.99 57451194 3.98 2016.02 57851234 6.31 2013.69

Test Report

Custom EMC Test Report No: EDCS - 1511861 Page No: 1 of 74 This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version. Cisco Systems, Inc. Company Confidential Test Report AIR-RM3010L-z-K9 (Where z=A, B, D, N, T or Z) FCC ID: LDK102094 IC: 2461B-102094 2400-2483.5 MHz Against the following Specifications: CFR47 Part 15.247 RSS-247 RSS-Gen Cisco Systems 170 West Tasman Drive San Jose, CA 95134 Approved by: Bud Chiller Revision: 1 This report replaces any previously entered test report under EDCS – 1511861.This test report has been electronically authorized and archived using the CISCO Engineering Document Control system. Custom EMC Test Report No: EDCS - 1511861 Page No: 2 of 74 This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version. Cisco Systems, Inc. Company Confidential This test report has been electronically authorized and archived using the CISCO Engineering Document Control system. SECTION 1: OVERVIEW ......................................................................................................................................... 3 SECTION 2: ASSESSMENT INFORMATION ...................................................................................................... 4 2.1 GENERAL ............................................................................................................................................................. 4 2.2 DATE OF TESTING ................................................................................................................................................ 7 2.3 REPORT ISSUE DATE ............................................................................................................................................ 7 2.4 TESTING FACILITIES ............................................................................................................................................. 7 2.5 EQUIPMENT ASSESSED (EUT) ............................................................................................................................. 8 2.6 EUT DESCRIPTION ............................................................................................................................................... 9 SECTION 3: RESULT SUMMARY ....................................................................................................................... 10 3.1 RESULTS SUMMARY TABLE ............................................................................................................................... 10 SECTION 4: SAMPLE DETAILS ........................................................................................................................... 13 APPENDIX A: EMISSION TEST RESULTS ................................................................................................. 14 CONDUCTED TEST SETUP DIAGRAM ........................................................................................................................ 14 TARGET MAXIMUM CHANNEL POWER .................................................................................................................... 14 A.1 6DB BANDWIDTH .................................................................................................................................... 15 A.2 99% AND 26DB BANDWIDTH .................................................................................................................. 26 A.3 MAXIMUM CONDUCTED OUTPUT POWER ................................................................................................ 37 A.4 POWER SPECTRAL DENSITY .................................................................................................................... 42 A.5 CONDUCTED SPURIOUS EMISSIONS ......................................................................................................... 53 A.6 CONDUCTED BANDEDGE ......................................................................................................................... 64 APPENDIX B: LIST OF TEST EQUIPMENT USED TO PERFORM THE TEST .................................... 72 APPENDIX C: ABBREVIATION KEY AND DEFINITIONS ...................................................................... 73 Custom EMC Test Report No: EDCS - 1511861 Page No: 3 of 74 This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version. Cisco Systems, Inc. Company Confidential Section 1: Overview The samples were assessed against the tests under the requirements of the following specifications: Emission CFR47 Part 15.247 RSS247 Issue 1: May 2015 RSS-Gen Issue 4: Nov 2014 Measurements were made in accordance with  ANSI C63.10:2013  FCC KDB 662911 D01  KDB 558074 D01 Meas Guidance v03r03 Custom EMC Test Report No: EDCS - 1511861 Page No: 4 of 74 This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version. Cisco Systems, Inc. Company Confidential Section 2: Assessment Information 2.1 General This report contains an assessment of an apparatus against Electromagnetic Compatibility Standards based upon tests carried out on the samples submitted. The testing was performed by and for the use of Cisco systems Inc: With regard to this assessment, the following points should be noted: a) The results contained in this report relate only to the items tested and were obtained in the period between the date of the initial assessment and the date of issue of the report. Manufactured products will not necessarily give identical results due to production and measurement tolerances. b) The apparatus was set up and exercised using the configuration and modes of operation defined in this report only. c) Where relevant, the apparatus was only assessed using the susceptibility criteria defined in this report and the Test Assessment Plan (TAP). d) All testing was performed under the following environmental conditions:…

Text truncated - open the document above for the full version.

Test Report

Custom EMC Test Report No: EDCS - 1514394 Page No: 1 of 15 This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version. Cisco Systems, Inc. Company Confidential Test Report Spurious and EMC Emissions AIR-RM3010L-B-K9 FCC ID: LDK102094 IC: 2461B- 102094 Also Covers: AIR-RM3010L -A-K9 AIR-RM3010L -N-K9 AIR-RM3010L-S-K9 AIR-RM3010L-T-K9 AIR-RM3010L-Z-K9 Receiver Spurious up to 40 GHz & 2412 - 2462 MHz Tx Against the following Specifications: CFR47 Part 15.247 RSS-210 LP0002 Cisco Systems 170 West Tasman Drive San Jose, CA 95134 Revision 1 Custom EMC Test Report No: EDCS - 1514394 Page No: 2 of 15 This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version. Cisco Systems, Inc. Company Confidential Contents Section 1: Overview 3 1.1 Test Summary 3 Section 2: Assessment Information 4 2.1 General 4 2.2 Date of testing 5 2.3 Report Issue Date 5 2.4 Testing facilities 5 2.5 Equipment Assessed (EUT) 5 2.6 EUT Description 5 Appendix A: Emission Test Results 6 Radiated Spurious Emissions 6 Conducted Emissions 12 Radiated emissions 12 Appendix B: Test Equipment/Software Used to perform the test 14 Custom EMC Test Report No: EDCS - 1514394 Page No: 3 of 15 This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version. Cisco Systems, Inc. Company Confidential Section 1: Overview 1.1 Test Summary The samples were assessed against the tests detailed in section 3 under the requirements of the following specifications: Emission Immunity CFR47 Part 15 RSS-210 LP0002 N/A The specifications listed above represent actual tests performed to demonstrate compliance against the specifications and basic standards listed on the front cover of this report. This list is not a one to one match to the front cover for one or more of the following reasons. 1. Basic standards call up many different test phenomena specifications such as the 61000-4-X series. The basic standards define which elements and levels shall be applied from these specifications and as such it is not appropriate to list the individual specifications on the front cover. 2. A Standard listed on the front cover may be required in a particular country but is not appropriate for the particular technologies included in the equipment under test. E.g. You cannot test a DC product to the mains Harmonics requirements in EN61000-3-2. See section 3.2. 3. Test results against a particular standard or specification may be included in a different test report. See section 3.2 for an EDCS reference of this data. 4. Where appropriate, Cisco may have substituted a later revision of a basic standard to those referenced in the specification on the front sheet of this test report. This decision was based upon improved test methodology and repeatability and/or where the newer revision represented a more stringent test. 5. Where relevant, testing has been carried out to the requirements of both EN and IEC Specifications. This was possible because of the similarities of the test methods involved and the Cisco EMC test procedures. 6. Testing may have been performed to an equivalent test that satisfies the requirements of the standards and specifications listed on the front cover of the report. See section 3.2. 7. Where radiated emissions testing has been performed to EN55022/CISPR22 the additional requirements of VCCI: V- 3/2006.04, EN55022: 1994 +A1/2 and CAN/CSA- CISPR 22-02 have also been evaluated unless otherwise stated. 8. Testing to the requirements of CFR47 Part 15 was performed against the CISPR22 limits. The results are therefore deemed satisfactory evidence of compliance with Industry Canada Interference Causing Equipment Standard ICES-003. 9. Where assessment has been performed to CISPR24, all the applicable test requirements may have not been covered. Refer to the results section for the tests performed. Notes: 1) Where a specification listed on the front cover of this report has deviations from the basic standards listed above, the additional technical requirements of the specification were also assessed. 2) Where appropriate, Cisco may have substituted a later revision of a basic standard to those referenced in the specification on the front sheet of this test report. This decision was based upon improved test methodology and repeatability and/or where the newer revision represented a more stringent test. 3) Where relevant, testing has been carried out to the requirements of both EN and IEC Specifications. This was possible because of the similarities of the test methods involved and the Cisco EMC test procedures. Custom EMC Test Report No: EDCS - 1514394 Page No: 4 of 15 This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version. Cisco Systems, Inc. Company Confidential Section 2: Assessment Information 2.1 General This report contains an assessment of an apparatus against Electromagnetic Compatibility Standards based upon tests carried out on the samples submitted. The testing was performed by and for the use of Cisco systems Inc. With regard to this assessment, the following points should be noted: a) The results contained in this report relate only to the items tested and were obtained in the period between the date of the initial assessment and the date of issue of the report. Manufactured products will not necessarily give identical results due to production and measurement tolerances. b) The apparatus was set up and exercised using the configuration and modes of operation defined in the operations manual. c) Where relevant, the apparatus was only assessed using the susceptibility criteria defined in this report and the Test Assessment Plan (TAP). d) All testing was performed under the following environmental conditions: Temperature 15°C to 35°C (54°F to 95°F) Atmospheric Pressure 860mbar to 1060mbar (25.4" to 31.3") Humidity 10% to 75*% *[Where applicable…

Text truncated - open the document above for the full version.

Test Setup Photos

AIR‐RM3010L‐B‐K9 Module FCC I.D. LDK102094 Test Setup Photos 30MHz – 1GHz Radiated Emissions and Susceptibility 1 – 18GHz Setup 18 – 40GHz Setup AC Conducted Emissions Setup

Contact Information

Applicant

Samuel Kim(Manager, Engineering)
[email protected]408-527-1446Fax: 408-527-1446

Test Firm

Cisco Systems, Inc.Dave Wilson
[email protected]408-525-0324Fax: 4085264184

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.40 GHz - 2.48 GHz870.00 µW
Software Defined Radio
Yes
Confidentiality
Long Term
Grant Notes
Output power is maximum combined conducted power. This device is capable of 4x4 MIMO operation. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Cisco Systems Inc

Wireless Phone - FCC ID LDKJ98213058 - Cisco Systems Inc
LDKJ98213058

Wireless Phone

May 25, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
LDKIW9165E

Wi-Fi 6E Outdoor Access Point

Aug 20, 2024

Equipment Class

6SD - 15E 6 GHz Standard Power Access Point
LDKIW9165DH

Wi-Fi 6E Outdoor Access Point

Aug 05, 2024

Equipment Class

6SD - 15E 6 GHz Standard Power Access Point
LDKUSBC2857

Cisco Headset USB-C Adapter

Jul 22, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
LDKESPRD2922

UC Phone

May 09, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX