FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Agilis Communication Technologies Pte Ltd/
  3. M2EBB100

M2EBB100AUTOMATIC DOOR ACTIVATOR

Agilis Communication Technologies Pte Ltd
AUTOMATIC DOOR ACTIVATOR - FCC ID M2EBB100 - Agilis Communication Technologies Pte Ltd
Click to zoom

Application Details

Equipment Class
FDS - Part 15 Field Disturbance Sensor
Date of Grant
Nov 18, 2002
Application Purpose
Original Equipment
Date of Application
Mar 17, 1999
Equipment Note
AUTOMATIC DOOR ACTIVATOR
Frequency Range
10525.00000000 - 10525.00000000
Company
Agilis Communication Technologies Pte Ltd
Country
Singapore

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Test Report

Master: ktlPT15C-FDS Date: February 23, 1999 KTL Test Report:8R00471 Applicant:Agilis Communications Tech. Pte Ltd. Singapore Technologies Building 100 Jurong East Street 21, Level 4 Singapore 609602 Equipment Under Test:BB100 Automatic Door Activator (E.U.T.) FCC ID:M2EBB100 In Accordance With:FCC Part 15, Subpart C For Operation Within The Bands 902-928 MHz, 2435-2465 MHz, 5785-5815 MHz, 10500-10550 MHz, 24075-24175 MHz Intentional Radiators Used As Field Disturbance Sensors Excluding Perimeter Protection Systems Tested By:KTL Ottawa Inc. 3325 River Road, R.R. 5 Ottawa, Ontario K1V 1H2 Authorized By: Russell Grant, Senior Technologist Date: Total Number of Pages: KTL OttawaFCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 2 of 24 Table of Contents Section 1. Summary of Test Results General Summary of Test Data Section 2. Equipment Under Test General Equipment Information Description of E.U.T. Modifications Incorporated in E.U.T. Theory of Operation Exercise Program Section 3. Equipment Configuration Equipment Configuration List Inter-Connection Cables Configuration of E.U.T. Section 4. Radiated Emissions Test Conditions Test Results Test Data - Radiated Emissions Radiated Photographs Section 5. Powerline Conducted Emissions Test Conditions Test Results Test Data Section 6. Block Diagrams Conducted Emissions Radiated Prescan Outdoor Test Site for Radiated Emissions Indoor Measurement Setup for Emissions Above 10 GHz Section 7. Test Equipment List Annex A - Restricted Bands Annex B - Radiated Emission Limits KTL OttawaFCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 3 of 24 Section 1.Summary of Test Results Manufacturer:Agilis Communications Tech. PTE Ltd. Model No.:BB100 Serial No.:None General:All measurements are traceable to national standards. These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with Part 15, Subpart C, Paragraph 15.245. All tests were conducted using measurement procedure ANSI C63.4-1992. Radiated emissions are made on an open area test site. A description of the test facility is on file with the FCC. New SubmissionProduction Unit Class II Permissive ChangePre-Production Unit FDS Equipment Code THIS TEST REPORT RELATES ONLY TO THE ITEM(S) TESTED. THE FOLLOWING DEVIATIONS FROM, ADDITIONS TO, OR EXCLUSIONS FROM THE TEST SPECIFICATIONS HAVE BEEN MADE. See “ Summary of Test Data”. NVLAP LAB CODE: 100351-0 TESTED BY: _____________________________________ DATE: ___________________ Tom Tidwell KTL Ottawa Inc. authorizes the above named company to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. KTL Ottawa Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. This report applies only to the items tested. KTL OttawaFCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 4 of 24 Summary Of Test Data Name of TestParagraph NumberResults Radiated Emissions15.231(b)Complies Powerline Conducted Emissions15.207Complies Footnotes For N/A’s: Test Conditions: IndoorTemperature: 20 °C Humidity:30 % OutdoorTemperature: Not Applicable Humidity:Not Applicable KTL OttawaFCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 5 of 24 Section 2.Equipment Under Test (E.U.T.) General Equipment Information Frequency Range: 10.525 GHz Operating Frequency(ies) of Sample: 10.525 GHz Type of Emission: Pulsed Carrier Emission Designator: PON Supply Power Requirement: 12-24 VAC / Vdc Duty Cycle Calculation: 20 log (43.4 / 546) = -22.0 dB See attached graphs. KTL OttawaFCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 6 of 24 KTL OttawaFCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 7 of 24 KTL OttawaFCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 8 of 24 KTL OttawaFCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 9 of 24 Description of E.U.T. The E.U.T. is a 10.525 GHz motion detector used for opening doors. Modifications Incorporated in E.U.T. The EUT has not been modified from what is described by the brand name and unique type identification stated above. KTL OttawaFCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 10 of 24 Theory of Operation KTL OttawaFCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 11 of 24 Justification The E.U.T. was configured for testing as per typical installation. The following combinations were investigated to establish worst case configuration: (1) Three axis. Exercise Program The E.U.T. exercise program used during radiated and conducted testing was designed to exercise the various system components in a manner similar to typical use. Exercise Mode: (1) Tx KTL OttawaFCC PART 15, SUBPART C INTENTIONAL RADIATORS USED …

Text truncated - open the document above for the full version.

Test Report

Master: ktlPT15C-FDS Date: February 23, 1999 KTL Test Report:8R00471 Applicant:Agilis Communications Tech. Pte Ltd. Singapore Technologies Building 100 Jurong East Street 21, Level 4 Singapore 609602 Equipment Under Test:BB100 Automatic Door Activator (E.U.T.) FCC ID:M2EBB100 In Accordance With:FCC Part 15, Subpart C For Operation Within The Bands 902-928 MHz, 2435-2465 MHz, 5785-5815 MHz, 10500-10550 MHz, 24075-24175 MHz Intentional Radiators Used As Field Disturbance Sensors Excluding Perimeter Protection Systems Tested By:KTL Ottawa Inc. 3325 River Road, R.R. 5 Ottawa, Ontario K1V 1H2 Authorized By: Russell Grant, Senior Technologist Date: Total Number of Pages: KTL Ottawa FCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 2 of 24 Table of Contents Section 1. Summary of Test Results General Summary of Test Data Section 2. Equipment Under Test General Equipment Information Description of E.U.T. Modifications Incorporated in E.U.T. Theory of Operation Exercise Program Section 3. Equipment Configuration Equipment Configuration List Inter-Connection Cables Configuration of E.U.T. Section 4. Radiated Emissions Test Conditions Test Results Test Data - Radiated Emissions Radiated Photographs Section 5. Powerline Conducted Emissions Test Conditions Test Results Test Data Section 6. Block Diagrams Conducted Emissions Radiated Prescan Outdoor Test Site for Radiated Emissions Indoor Measurement Setup for Emissions Above 10 GHz Section 7. Test Equipment List Annex A - Restricted Bands Annex B - Radiated Emission Limits KTL Ottawa FCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 3 of 24 Section 1.Summary of Test Results Manufacturer:Agilis Communications Tech. PTE Ltd. Model No.:BB100 Serial No.:None General: All measurements are traceable to national standards. These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with Part 15, Subpart C, Paragraph 15.245. All tests were conducted using measurement procedure ANSI C63.4-1992. Radiated emissions are made on an open area test site. A description of the test facility is on file with the FCC. New SubmissionProduction Unit Class II Permissive ChangePre-Production Unit FDS Equipment Code THIS TEST REPORT RELATES ONLY TO THE ITEM(S) TESTED. THE FOLLOWING DEVIATIONS FROM, ADDITIONS TO, OR EXCLUSIONS FROM THE TEST SPECIFICATIONS HAVE BEEN MADE. See “ Summary of Test Data”. NVLAP LAB CODE: 100351-0 TESTED BY: _____________________________________ DATE: ___________________ Tom Tidwell KTL Ottawa Inc. authorizes the above named company to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. KTL Ottawa Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. This report applies only to the items tested. KTL Ottawa FCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 4 of 24 Summary Of Test Data Name of TestParagraph NumberResults Radiated Emissions15.231(b)Complies Powerline Conducted Emissions15.207Complies Footnotes For N/A’s: Test Conditions: Indoor Temperature: 20 °C Humidity:30 % Outdoor Temperature: Not Applicable Humidity:Not Applicable KTL Ottawa FCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 5 of 24 Section 2.Equipment Under Test (E.U.T.) General Equipment Information Frequency Range: 10.525 GHz Operating Frequency(ies) of Sample: 10.525 GHz Type of Emission: Pulsed Carrier Emission Designator: PON Supply Power Requirement: 12-24 VAC / Vdc Duty Cycle Calculation: 20 log (43.4 / 546) = -22.0 dB See attached graphs. KTL Ottawa FCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 6 of 24 KTL Ottawa FCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 7 of 24 KTL Ottawa FCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 8 of 24 KTL Ottawa FCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 9 of 24 Description of E.U.T. The E.U.T. is a 10.525 GHz motion detector used for opening doors. Modifications Incorporated in E.U.T. The EUT has not been modified from what is described by the brand name and unique type identification stated above. KTL Ottawa FCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 10 of 24 Theory of Operation KTL Ottawa FCC PART 15, SUBPART C INTENTIONAL RADIATORS USED AS FIELD DISTURBANCE SENSORS PROJECT NO.: 8R00471 EQUIPMENT: BB100 Automatic Door Activator FCC ID: M2EBB100 Page 11 of 24 Justification The E.U.T. was configured for testing as per typical installation. The following combinations were investigated to establish worst case configuration: (1) Three axis. Exercise Program The E.U.T. exercise program used during radiated and conducted testing was designed to exercise the various system components in a manner similar to typical use. Exercise Mode: (1) Tx KTL Ottawa FCC PART 15, SUBPART C INTENTIONAL R…

Text truncated - open the document above for the full version.

Contact Information

Applicant

On Yu Chan(Senior Manager)
[email protected]011655627440Fax: 011655676370

Technical Contact

AGILIS COMMUNICATIONS TECH. PTE LTDON Y CHAN
[email protected]011655627440

100 JURONG EAST ST 21 · SINGAPORE · Singapore

Non-Technical Contact

AGILIS COMMUNICATION TECH. PTE LTS.ON Y CHAN
[email protected]011655687440

Test Firm

Nemko Canada Inc.Stuart Beck
[email protected]613-737-9680Fax: 613-737-9691

Technical Specifications

#Rule PartsFrequency RangePower OutputEmission
115C10.53 GHz - 10.53 GHz-1M83PON

Other Applications from Agilis Communication Technologies Pte Ltd

Automatic door activator - FCC ID M2EKF600 - Agilis Communication Technologies Pte Ltd
M2EKF600

Automatic door activator

Nov 10, 2002

Equipment Class

FDS - Part 15 Field Disturbance Sensor