M5X-TA58Wireless Transmitter

Mipro Electronics Co Ltd
Wireless Transmitter - FCC ID M5X-TA58 - Mipro Electronics Co Ltd
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jun 06, 2021
Application Purpose
Original Equipment
Date of Application
Jun 06, 2021
Equipment Note
Wireless Transmitter
Frequency Range
5735.00000000 - 5839.00000000
Company
Mipro Electronics Co Ltd
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Date: 2021-05-21 To whom it may concern: We, the undersigned, hereby authorize Worldwide Testing Services (Taiwan) Co., Ltd to act on our behalf in all matters relating to applications for equipment authorization FCC ID: M5X-TA58 including the signing of all documents related to these matters. Any and all acts carried out by Worldwide Testing Services (Taiwan) Co., Ltd on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name: Solomon Chang Title: President Company: MIPRO Electronics Co., Ltd.

Cover Letter(s)

Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Date: 2021-05-21 Request for Long-Term Confidentiality Company name: MIPRO Electronics Co., Ltd. FCC ID: M5X-TA58 FCC Part 15 Certification To whom it may concern: In accordance with §§ 0.457(d) and 0.459 of CFR 47, MIPRO Electronics Co., Ltd. hereby requests Long-Term confidentiality of all Block Diagrams, Schematics, Operational Description attachments for the subject application. These documents contain detailed system and equipment description and related information about the product which MIPRO Electronics Co., Ltd. considers to be proprietary, confidential and a custom design and otherwise would not release to the general public. Since the design is a basis from which future technological products will evolve, MIPRO Electronics Co., Ltd. considers that this information would be of benefit to its competitors and that the disclosure of the information in these documents would give competitors an unfair advantage in the market. Sincerely, Name: Solomon Chang Title: President Company: MIPRO Electronics Co., Ltd.

External Photos

Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 External Photos Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 1 of 18 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 2 of 18 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 3 of 18 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 4 of 18 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 5 of 18 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 6 of 18

Internal Photos

Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Internal Photos Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 7 of 18 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 8 of 18 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 9 of 18 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 10 of 18 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 11 of 18 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 12 of 18

Internal Photos

Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 13 of 18 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 14 of 18 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 15 of 18

RF Exposure Info

Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Applicant’s declaration concerning RF Radiation Exposure We hereby indicate that the product Product description: Wireless Transmitter Model No: TA-58, TA-XXXX (X=0~9,a~z,A~Z or Blank) The equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The integral antennas used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within the host device. A safety statement concerning minimum separation distances from enclosure of the Product : Transmitter will be integrated in the user’s manual to provide end-users with transmitter operating conditions for satisfying RF exposure compliance. The appropriate information can be drawn from the test report no: W6M22104-20820-C-54 and the accompanying calculations. Company: MIPRO Electronics Co., Ltd. Address: 814, Beigang Rd., Chiayi City 600079, Taiwan Date: 2021-05-21 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 3.6 Automatic Discontinuation of transmission, FCC 15.407 (c) The device shall automatically discontinue transmission in case of either absence of information to transmit or operational failure. This function will be declared by manufacturer. 3.7 Reserved, FCC 15.407 (d) 3.8 Indoor Operation Restriction, FCC 15.407 (e) Within the 5.15–5.25 GHz band, U- NII devices will be restricted to indoor operations to reduce any potential for harmful interference to co-channel MSS operations. This equipment has to be declared by manufacturer of the final product as content of the user manual. 3.9 Equivalent Isotropic Radiated Power (EIRP), FCC 15.407 (f) EIRP = max. conducted output power + antenna gain EIRP = 10.33 dBm + 0 dBi [antenna gain claimed by manufacturer] = 10.33 dBm = 10.7895 mW Test equipment used: ETSTW-RE 055 Worldwide Testing Services(Taiwan) Co., Ltd. Page 23 of 33 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 3.10 Exemption Limits for Routine Evaluation according to 47 CFR FCC Part 2 Subpart J, section 2.1091 FCC OET Bulletin 65 Edition 97.01 determines the equations for predicting RF fields and applicable limits. The prediction for power density in the far-field but will over-predict power density in the near field, where it could be used for walking a “worst case” or conservative prediction. Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device whereby a distance of 20 cm normally can be maintained between the user and the device. E = Electric field (V/m) P = output power (W) G = EUT Antenna numeric gain (numeric) d = Separation distance between radiator and human body (m) The formula can be changed to mW/m 2. Worldwide Testing Services(Taiwan) Co., Ltd. Page 24 of 33 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Established separation distance is 20 cm. Operating frequency band: 5735-5839 MHz The product meets RF exposure requirement. Because the power density of 0.0021 mW/cm 2 at 5839 MHz is below the power density limit of 1 mW/cm 2 . Limits: Limit for General Population / Uncontrolled Exposure Frequency (MHz) Power Density (mW/cm 2 ) 1500 – 100.000 1.0 Worldwide Testing Services(Taiwan) Co., Ltd. Page 25 of 33

Test Report

of Applicant: MIPRO Electronics Co., Ltd. Address: 814, Beigang Rd., Chiayi City 60096, Taiwan, R.O.C Tested and Prepared by Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1477, TW0020, TW1072 Industry Canada filed test laboratory Reg. No. 20037 Report No.: W6M22104-20820 -C-54 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E- mail: [email protected] 47 CFR PART 15 SUBPART E TEST REPORT for Wireless Transmitter Model No.: TA-58 FCC ID: M5X-TA58 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 TABLE OF CONTENTS 1 GENERAL INFORMATION .......................................................................................................... 2 1.1 NOTES .......................................................................................................................................... 2 1.2 TESTING LABORATORY ................................................................................................................ 3 1.2.1 Location .............................................................................................................................. 3 1.2.2 Details of accreditation status ............................................................................................ 3 1.3 D ETAILS OF APPROVAL HOLDER ................................................................................................... 3 1.4 APPLICATION DETAILS ................................................................................................................. 3 1.5 GENERAL INFORMATION OF TEST ITEM ........................................................................................ 4 1.6 T EST STANDARDS ......................................................................................................................... 5 2 TECHNICAL TEST ......................................................................................................................... 6 2.1 S UMMARY OF TEST RESULTS ........................................................................................................ 6 2.2 T EST ENVIRONMENT .................................................................................................................... 6 2.3 TEST EQUIPMENT LIST ................................................................................................................. 7 2.4 TEST PROCEDURE ...................................................................................................................... 10 3 TEST RESULTS (ENCLOSURE) ................................................................................................ 13 3.1 P EAK TRANSMIT POWER, FCC 15.407 (A) ................................................................................. 14 3.2 26DB EMISSION BANDWIDTH, 99% OCCUPIED BANDWIDTH, FCC 15.407 (A) ........................... 16 3.3 6DB EMISSION BANDWIDTH, 99% OCCUPIED BANDWIDTH, FCC 15.407 (A) ............................. 17 3.4 PEAK POWER SPECTRAL DENSITY, FCC 15.407 (A) .................................................................. 19 3.5 U NDESIRABLE EMISSION LIMITS, FCC 15.407 (B) ...................................................................... 21 3.6 AUTOMATIC DISCONTINUATION OF TRANSMISSION, FCC 15.407 (C) ......................................... 23 3.7 RESERVED, FCC 15.407 (D) ....................................................................................................... 23 3.8 INDOOR OPERATION RESTRICTION, FCC 15.407 (E) .................................................................. 23 3.9 EQUIVALENT ISOTROPIC RADIATED POWER (EIRP), FCC 15.407 (F) ........................................ 23 3.10 EXEMPTION LIMITS FOR ROUTINE EVALUATION ACCORDING TO 47 CFR FCC PART 2 SUBPART J, SECTION 2.1091 ..................................................................................................................... 24 3.11 TRANSMIT POWER CONTROL (TPC) .......................................................................................... 26 3.12 DYNAMIC FREQUENCY SELECTION (DFS) ................................................................................. 27 3.12.1 DFS Detection Threshold ................................................................................................. 27 3.12.2 Channel move time plot of Type1 radar waveform on 5270MHz ..................................... 27 3.12.3 30Minutes Non-Occupancy Time ...................................................................................... 27 3.13 C HANNEL MOVE TIME, CHANNEL CLOSING TRANSMISSION TIME ............................................. 28 3.14 R ADIATED EMISSIONS FROM RECEIVER PART ............................................................................ 29 3.15 POWER LINE CONDUCTED EMISSION ......................................................................................... 30 Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 33 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of …

Text truncated - open the document above for the full version.

Test Setup Photos

Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Set Up Photo of Radiated Emission Below 1 GHz Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 16 of 18 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Above 1 GHz Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 17 of 18 Registration number: W6M22104-20820-C-54 FCC ID: M5X-TA58 Set Up Photo of Conducted Emission Worldwide Testing Services(Taiwan) Co., Ltd. Appendix Page 18 of 18

Contact Information

Applicant

Solomon Chang
[email protected]+886-5-238-0809Fax: +886-5-238-0803

Technical Contact

Worldwide Testing Services (Taiwan) Co., Ltd.Danny Sung
[email protected]+886266068877

6F., No.58, Lane 188, Ruiguang Rd., Neihu District · Taipei · Taiwan

Test Firm

Worldwide Testing Services (Taiwan) Co., Ltd.Rex Kao
[email protected]886-2-6606-8877Fax: 886-2-6606-8879

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.74 GHz - 5.84 GHz10.80 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Mipro Electronics Co Ltd

Transmitter - FCC ID M5X-MT58A - MIPRO ELECTRONICS CO., LTD.
M5X-MT58A

Transmitter

Jun 05, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
TRANSMITTER - FCC ID M5X-ACT33TW - MIPRO ELECTRONICS CO., LTD.
M5X-ACT33TW

TRANSMITTER

Dec 22, 2025

Equipment Class

DWM - Part 15 Wireless Microphone
Transmitter - FCC ID M5X-ACT240T - Mipro Electronics Co Ltd
M5X-ACT240T

Transmitter

Jul 26, 2021

Equipment Class

DTS - Digital Transmission System
Wireless Transmitter - FCC ID M5X-MTM24 - Mipro Electronics Co Ltd
M5X-MTM24

Wireless Transmitter

Jul 11, 2021

Equipment Class

DTS - Digital Transmission System
Wireless Transmitter - FCC ID M5X-MTM58 - Mipro Electronics Co Ltd
M5X-MTM58

Wireless Transmitter

Jul 11, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX