Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Project Name WiFi module Approval Sheet Rev. 1.0 Foxconn Part No. J20H078.00 Prepared by Reviewed by Approved by May Sun Eddie Huang Choro Chuang Ambit Microsystems (Shanghai) LTD. No 1925, Nanle Road Songjiang Export Processing Zone Shanghai, China Tel :86-21-61206688 Ext:22165 FAX:86-21-57749230 User Manual of J20H078 802.11bgn wireless module CONTENTS 1 REVISION HISTORY 2 MANUFACTURING INFORMATION 3 PRODUCT OVERVIEW 3.1 APPLICATION SCOPE 4 MODULE HARDWARE OVERVIEW 4.1 BLOCK DIAGRAM 4.2 FEATURES 4.3 INTERFACE AND CONNECTOR 5 ELECTRICAL SPECIFICATION 5.1 ABSOLUTE MAXIMUM RATING 5.2 RECOMMENDED OPERATING RATING 5.3 DC CHARACTERISTICS 5.4 ESD INFORMATION 5.5 ENVIRONMENT STORAGE CONDITION 6 RF SPECIFICATION 6.1 IEEE802.11B 6.2 IEEE802.11G 6.3 802.11N HT20 6.4 ANTENNA ELECTRICAL SPECIFICATION 7 MECHANICAL SPECIFICATIONS 7.1 SHIELDING COVER DIMENSION 7.2 PCB ASSEMBLY DIMENSION 7.3 MOUNT POSITION OF MATERIALS 1 Revision History Date Document revision Change Description 2013/07/09 1.0 Initial release 2 Manufacturing Information Manufacture Country: Made in China Manufacturer: Ambit Microsystems (Shanghai) LTD. Manufacture Address: No 1925, Nanle Road Songjiang Export Processing Zone Shanghai, China 3 Product Overview The J20H078.00 802.11b/g/n module provides wireless modem functionality utilizing direct sequence spread spectrum and OFDM/CCK technology. This module is based on MTK MT7601U solution .It fully complies with IEEE 802.11n and IEEE 802.11 b/g standards, offering feature-rich wireless connectivity at high standards, and delivering reliable, cost-effective throughput from an extended distance. Optimized RF architecture and baseband algorithms provide superb performance and low power consumption. Intelligent MAC design deploys a high efficient DMA engine and hardware data processing accelerators which offloads the host processor. 3.1 Application scope The wireless LAN is compliant to IEEE 802.11b and IEEE 802.11g and IEEE 802.11n standard. The data rate of 802.11b is up to 11Mbps and fallback rates of 5.5, 2, 1Mbps. The data rate of 802.11g is up to 54Mbps and fallback rates of 48,36,24,18,12,9, 6Mbps. The data rate of 802.11n HT20 is up to 65Mbps and fallback rates of 58.5, 52, 39, 26, 19.5, 13, 6.5Mbps; 72.2Mbps. 4 Module Hardware Overview 4.1 Block Diagram The general HW architecture is shown below Figure: . Module Block Diagram 4.2 Features ♦ IEEE802.11b/g/n (1X1) based on MTK MT7601U solution. ♦ USB 2.0 Interface, High and Full Speeds supported. ♦ Module is powered by the host with a 5.0V +/- 5% supply. ♦ External PCB printed antennas. ♦ 2 layers through hole PCB design with halogen free FR4 material 4.3 Interface and Connector ♦ Pin definition: ♦ Vendor: Kyocera Elco ♦ Vendor P/N: 046232105102800+ Pin Number Symbol Name Status Pin definition 1 GND Ground 2 DP I/O USB positive data 3 DM I/O USB negative data 4 GND Ground 5 UV+ P USB +5V power input S1 GND Ground S2 GND Ground 5 Electrical Specification 5.1 Absolute maximum rating Element Symbol Min Typ Max Unit DC supply voltage UV+ 5.0 6.5 (V) 5.2 Recommended operating rating Element Symbol Min …
Text truncated - open the document above for the full version.
HON HAI PRECISION IND. CO., LTD. 5F-1,5 Hsin-An Road Hsinchu, Science-Based Industrial Park Taiwan, R.O.C. Date: 2013/7/4 GENERAL DECLARATION We, HON HAI PRECISION IND. CO., LTD. declare that the device does not support any non-US channels in all the operational mode(s) for the following product. FCC ID: MCLJ20H078 If you have any questions regarding the authorization, please don’t hesitate to contact us. Thank you! Signature: Rio Chen Compliance Manager HON HAI PRECISION IND. CO., LTD. TEL: +886-3-5784975 FAX: +886-3-5775100 E-mail: [email protected]
HON HAI PRECISION IND. CO., LTD. 5F-1,5 Hsin-An Road Hsinchu, Science-Based Industrial Park Taiwan, R.O.C. Federal Communications Commission Authorization and Evaluation Division Date: August 14, 2013 Confidentiality Request FCC ID: MCLJ20H078 Pursuant to DA 04-1705 of the Commission’s Rules, we request short-term confidential treatment for the following information until Oct. 15th, 2013 of Equipment Authorization in order to ensure sensitive business information remains confidential until the actual marketing of the device: External Photos Test Setup Photos User’s Manual Internal Photo Thank you! Sincerely yours, ------------------------------------------------------- Rio Chen Compliance Manager HON HAI PRECISION IND. CO., LTD. TEL: +886-3-5784975 FAX: +886-3-5775100 E-mail: [email protected]
HON HAI PRECISION IND. CO., LTD. 5F-1,5 Hsin-An Road Hsinchu, Science-Based Industrial Park Taiwan, R.O.C. Date:2013/7/4 FCC ID: MCLJ20H078 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Schematics Block Diagram The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely yours, Rio Chen Compliance Manager HON HAI PRECISION IND. CO., LTD. TEL: +886-3-5784975 FAX: +886-3-5775100 E-mail: [email protected]
HON HAI PRECISION IND. CO., LTD. 5F-1,5 Hsin-An Road Hsinchu, Science-Based Industrial Park Taiwan, R.O.C. AGENCY AUTHORIZATION LETTER Date: 2013/7/4 To whom it may concern: We, the undersigned, , HON HAI PRECISION IND. CO., LTD. hereby authorize Bureau Veritas Consumer Products Services (H.K) Ltd., Taoyuan Branch. of Taiwan to act on our behalf in all matters relating to all processes required in the FCC Part 15C+15E approval and any communication needed with the national authority. Any and all acts carried out by Bureau Veritas Consumer Products Services (H.K) Ltd., Taoyuan Branch. on our behalf shall have the same effects as acts of our own. If you have any questions regarding the authorization, please don’t hesitate to contact us. Thank you! Sincerely yours, Signature: Rio Chen Compliance Manager HON HAI PRECISION IND. CO., LTD. TEL: +886-3-5784975 FAX: +886-3-5775100 E-mail: [email protected]
FCC ID: MCLJ20H078 Report No.: RF130708E01 Modular Approval Request Letter Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch August 15, 2013 Dear Application Examiner, HON HAI Precision Ind. Co., Ltd., device: a 802.11bgn wireless module, FCC ID: MCLJ20H078 would like to have your authorization as a modular device. The requirements of section 15.212 of FCC rules have been met and shown on the following statements. 1. “The modular transmitter must have its own RF shielding.”: The radio portion of this module has been shielded, please see exhibition External Photo. 2. “The modular transmitter must have buffered modulation/data inputs.” The EUT has buffered data input. It is integrated in chip MT7601U. 3. “The modular transmitter must have its own power supply regulation.” The part number of this regulator is MT7601U. 4. “The modular transmitter must comply with the antenna requirements of section 15.203 and 15.204(C).” The EUT meets the FCC antenna requirements. The spurious emission, unique antenna connector and photo of antennas are shown in the test report. 5. “The modular transmitter must be tested in a stand-alone configuration” The EUT was tested in a stand-alone configuration via extender. Please see section Photographs of Test Configuration in the test report, the EUT was plugged in this extender. 6. “The modular transmitter must be labeled with its own FCC ID number.” Please see exhibition Label Sample for the FCC ID of this module. And also in the exhibition Users Manual, there are instructions give to the OEM on how to label the end product. 7. “The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements.” The EUT is compliant with all applicable FCC rules. Detail instructions for maintaining compliance are given in the Users Manual. 8. “The modular transmitter must comply with any applicable RF exposure requirements.” The EUT is compliant with all applicable RF exposure requirements. RF Exposure is addressed in the RF exposure exhibition. Please contact me if you have any further questions. Thanks for your attention. Best Regards, signature Hank Chung Assistant Manager Bureau Veritas Consumer Products Services (H.K.) Ltd., Hsinchu Branch
Report No.: 130708E01 Page 1 CONSTRUCTION PHOTOS OF EUT Connector Type 1 Report No.: 130708E01 Page 2 Report No.: 130708E01 Page 3 Antenna (Model No.: 96.1099T00) Report No.: 130708E01 Page 4 Report No.: 130708E01 Page 5 Connector Type 2 Report No.: 130708E01 Page 6 Report No.: 130708E01 Page 7
Report No.: 130708E01 Page 1 CONSTRUCTION PHOTOS OF EUT Connector Type 1 Connector Type 2
FCC ID: MCLJ20H078 Report No.: RF130523E10 Operational Description This device is a 802.11bgn wireless module, which operates in 2.4GHz bands the maximum data rate could be up to 72.2Mbps which OFDM technique. If the signal to noise radio is too poor which could not support 72.2Mbps, the 11Mbps data rate with DSSS technique will be applied. The transmitter of the EUT is powered by DC 5V ± 10% from host equipment. The antenna is PCB antenna without antenna connectors. The other instruction, please have a look at the users manual.
Report No.: SA130708E01 1 of 6 Report Format Version 5.0.0 RF EXPOSURE REPORT REPORT NO.: SA130708E01 MODEL NO.: J20H078 FCC ID: MCLJ20H078 RECEIVED: July 08, 2013 TESTED: July 29, 2013 ISSUED: Aug. 14, 2013 APPLICANT: Hon Hai PRECISION IND.CO.,LTD ADDRESS: 5F-1, Hsin-An Road, Hsinchu, Science Industrial Park, Taiwan, R.O.C. ` ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS: No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. TEST LOCATION (1): No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. TEST LOCATION (2): No. 49, Ln. 206, Wende Rd., Shangshan Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. This report should not be used by the client to claim product certification, approval, or endorsement by any government agencies. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Report No.: SA130708E01 2 of 6 Report Format Version 5.0.0 TABLE OF CONTENTS RELEASE CONTROL RECORD .................................................................................... 3 1. CERTIFICATION ...................................................................................................... 4 2. RF EXPOSURE LIMIT .............................................................................................. 5 3. MPE CALCULATION FORMULA ............................................................................. 5 4. CLASSIFICATION .................................................................................................... 5 5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ........................... 6 Report No.: SA130708E01 3 of 6 Report Format Version 5.0.0 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED SA130708E01 Original release Aug. 14, 2013 Report No.: SA130708E01 4 of 6 Report Format Version 5.0.0 1. CERTIFICATION PRODUCT: 802.11bgn wireless module BRAND NAME: FOXCONN MODEL NO.: J20H078 TEST SAMPLE: ENGINEERING SAMPLE APPLICANT: Hon Hai PRECISION IND.CO.,LTD TESTED DATE: July 29, 2013 STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (Model: J20H078) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE: Aug. 14, 2013 ( Phoenix Huang, Specialist ) APPROVED BY : , DATE: Aug. 14, 2013 ( May Chen, Manager ) Report No.: SA130708E01 5 of 6 Report Format Version 5.0.0 2. RF EXPOSURE LIMIT LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 3. MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale pi = 3.1416 r = distance between observation point and center of the radiator in cm 4. CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Report No.: SA130708E01 6 of 6 Report Format Version 5.0.0 5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER FREQUENCY (MHz) MAX POWER (mW) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/ cm 2 ) LIMIT (mW/cm 2 ) 2412 ~ 2462 301.301 0.59 20 0.06866 1 --- END --- CONCLUSION: Both of the 2.4GHz and 5GHz WLAN can transmit simultaneously, the formula of calculated the MPE is: CPD 1 / LPD 1 + CPD 2 / LPD 2 + ......etc. < 1 CPD = Calculation power density LPD = Limit of power density Therefore, the worst-case situation is 0.12256 / 1 + 0.42671 / 1 = 0.549, which is less than “1”. This confirmed that the device comply with FCC 1.1310 MPE limit.
Report No.: RF130708E01 1 of 51 Report Format Version 5.2.0 Reference No.: 121107E09 FCC TEST REPORT REPORT NO.: RF130708E01 MODEL NO.: J20H078 FCC ID: MCLJ20H078 RECEIVED: July 08, 2013 TESTED: July 15 to 30, 2013 ISSUED: Aug. 14, 2013 APPLICANT: Hon Hai PRECISION IND.CO.,LTD ADDRESS: 5F-1, Hsin-An Road, Hsinchu, Science Industrial Park, Taiwan, R.O.C. ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. TEST LOCATION (1): No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. TEST LOCATION (2): No. 49, Ln. 206, Wende Rd., Shangshan Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Report No.: RF130708E01 2 of 51 Report Format Version 5.2.0 Reference No.: 121107E09 Table of Contents RELEASE CONTROL RECORD ........................................................................................ 4 1. CERTIFICATION .................................................................................................... 5 2. SUMMARY OF TEST RESULTS ............................................................................ 6 2.1 MEASUREMENT UNCERTAINTY .......................................................................... 7 3. GENERAL INFORMATION ..................................................................................... 8 3.1 GENERAL DESCRIPTION OF EUT ....................................................................... 8 3.2 DESCRIPTION OF TEST MODES ....................................................................... 10 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ........................ 11 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ....................................... 14 3.4 DESCRIPTION OF SUPPORT UNITS .................................................................. 15 3.5 CONFIGURATION OF SYSTEM UNDER TEST ................................................... 15 4. TEST TYPES AND RESULTS .............................................................................. 16 4.1 CONDUCTED EMISSION MEASUREMENT ........................................................ 16 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ...................................... 16 4.1.2 TEST INSTRUMENTS .......................................................................................... 16 4.1.3 TEST PROCEDURES .......................................................................................... 17 4.1.4 DEVIATION FROM TEST STANDARD ................................................................. 17 4.1.5 TEST SETUP ....................................................................................................... 18 4.1.6 EUT OPERATING CONDITIONS ......................................................................... 18 4.1.7 TEST RESULTS ................................................................................................... 19 4.2 RADIATED EMISSION AND BANDEDGE MEASUREMENT ................................ 21 4.2.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT .............. 21 4.2.2 TEST INSTRUMENTS .......................................................................................... 22 4.2.3 TEST PROCEDURES .......................................................................................... 24 4.2.4 DEVIATION FROM TEST STANDARD ................................................................. 24 4.2.5 TEST SETUP ....................................................................................................... 25 4.2.6 EUT OPERATING CONDITIONS ......................................................................... 25 4.2.7 TEST RESULTS ................................................................................................... 26 4.3 6dB BANDWIDTH MEASUREMENT .................................................................... 36 4.3.1 LIMITS OF 6dB BANDWIDTH MEASUREMENT .................................................. 36 4.3.2 TEST INSTRUMENTS .......................................................................................... 36 4.3.3 TEST PROCEDURE ............................................................................................. 36 4.3.4 DEVIATION FROM TEST STANDARD ................................................................. 36 4.3.5 TEST SETUP ....................................................................................................... 36 4.3.6 EUT OPERATING CONDITIONS ...................…
Text truncated - open the document above for the full version.
Report No.: 130708E01 1 of 3 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST Report No.: 130708E01 2 of 3 RADIATED EMISSION TEST Report No.: 130708E01 3 of 3
81-1, Lu Laio Keng, 9th Ling, Wu Lung Tsuen, Chiun · Hsinchu Hsien · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 301.00 mW |

LTE M.2 Module
Equipment Class
CBE - Citizens Band End User Devices
LTE M.2 Module
Equipment Class
PCB - PCS Licensed Transmitter
IP Set-Top Box with Wi-Fi 11ac
Equipment Class
DTS - Digital Transmission System
IP Set-Top Box
Equipment Class
DTS - Digital Transmission System
WiFi/BT Module
Equipment Class
DTS - Digital Transmission System