Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Warning State ment Changes or modifica�ons not expressly approved by the par ty responsib le for compliance could void the user’s authorit y to operat e the equip ment. This equip ment has been tested and found to comply wit h the limit s for a Cla ss B dig it al devic e, pursuant to Par t 15 of the FCC Rule s. These limit s ar e desig ned to provid e reas onable protec�on again st har mful in terference in a resid en�al in stal la�on. This equip ment generat es uses and can radiate radio frequency energy and, if not in stalled and used in accordance wit h the in struc�ons, may cause har mful in terference to radio communic a�ons. However, there is no guar antee that in terference will not occur in a par�cular in stalla�on. If this equip ment does cause har mful in terference to radio or tele vis io n recep�on, which can be determin ed by turnin g the equip ment off and on, the user is encouraged to try to correct the in terference by one or more of the foll owin g meas ures: --Reorie nt or relo cat e the receiv in g antenna. --Increas e the separ a�on between the equip ment and receiv er. --Connect the equip ment in to an outle t on a cir cuit different from that to which the receiv er is connected. --Consult the dealer or an experie nced radio /T V technic ian for help . This devic e complies wit h par t 15 of the FCC rule s. Opera�on is subje ct to the followin g two condi�ons (1) this devic e may not cause har mful in terference, and (2) this devic e must accept any in terference receiv ed, in clu din g in terference that may cause undesir ed opera�on.
June 10, 2020 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: MN312000071 Product Name: Duo Wireless Computer Mouse Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential:  Schematics  Block diagram  Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name:Joe Volp Title:Director of Marketing Company:AbleNet, Inc.
June 10, 2020 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen Timeway Testing Laboratories/ 5/F,Block 4, Anhua Industrial Zone.,No.8 TaiRan Rd.CheGongMiao,FuTian District, Shenzhen,CHINA. (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with AbleNet, Inc./ 2625 Patton Road ,Roseville, MN 55113 , USA <Signature>: Name:Joe Volp Title:Director of Marketing Company:AbleNet, Inc.
29mm 12mm 2008 2020W33 Made in China Duoâ„¢ ablenetinc.com FCC ID: MN312000071 S/N XXXXXXXX
Label Location
RF Exposure evaluation According to 447498 D01 General RF Exposure Guidance v05 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison eirp = pt x gt = (EXd) 2 /30 where: pt = transmitter output power in watts, gt = numeric gain of the transmitting antenna (unitless), E = electric field strength in V/m, --- 10 ((dBuV/m)/ 20) /10 6 d = measurement distance in meters (m)---3m So pt = (EXd) 2 /30 x gt Field strength = 83.81dBuV/m @3m Ant gain =0.18dBi ;so Ant numeric gain= 1.04 So pt={ [10 ( 83.81/20) /10 6 x3] 2 /30x1.04 }x1000 mW =0.07mW So (0.07 mW/5mm)x √2.480GHz = 0.022 <3 Then SAR evaluation is not required
Report No.: FCC2004255-01 File Reference No.: 2020-05-15 Applicant: AbleNet, Inc. Product: Duo Wireless Computer Mouse Model No.: 12000071 Brand Name: N/A Test Standards: FCC Part 15.249 Test Result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4&FCC Part 15 Subpart C, Paragraph 15.249 regulations for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: May 15, 2020 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No.: FCC2004255-01 Page 2 of 37 Date: 2020-05-15 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used fo r adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. Industry Canada (IC) —Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 Report No.: FCC2004255-01 Page 3 of 37 Date: 2020-05-15 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used fo r adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ............................................................................................. 4 1.1 Test Lab Details............................................................................................. 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT .......................................................................................... 4 1.4 Submitted Sample............................................................................................. 5 1.5 Test Duration................................................................................................... 5 1.6 Test Uncertainty................................................................................................ 5 1.7 Test By......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details.......................................................................................... 7 4.0 EUT Modification............................................................................................. 7 5.0 Power Line Conducted Emission Test..................................................................... 8 5.1 Schematics of the Test....................................................................................... 8 5.2 Test Method and Test Procedure............................................................................ 8 5.3 Configuration of the EUT................................................................................. 8 5.4 EUT Operating Condition................................................................................. 9 5.5 Conducted Emission Limit.................................................................................. 9 5.6 Test Result...........................…
Text truncated - open the document above for the full version.
Radiated Emission Te s t Setup:
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |

Bluetooth Keyboard
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Wireless Switch System
Equipment Class
DTS - Digital Transmission SystemDSC - Part 15 Security/Remote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterR/C Switch Receiver
Equipment Class
CRR - Superregenerative Receiver