Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
UNITED STATES DESIGNATED AGENT LETTER Date: 2026-02-12 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Applicant U.S. designated agent Company Name: Master Lock Company LLC Company Name: Master Lock Company LLC Grantee Code: MZR FRN: 0021474101 Contact Name: Stephen Gaydos Contact Name: Stephen Gaydos Address: 1 Horizon Way Address: 1 Horizon Way City/Province/Zip: Deerfield City/Province/Zip: Deerfield Telephone: 847-484-4400 Telephone: 847-484-4400 Fax: Fax: Email: [email protected] Email: [email protected] Applicable Equipment: FCC ID: MZR-YMC624 ATTN: Director of Certification: We, Master Lock Company LLC, understand and acknowledge the applicants consent and the designated agent’s obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and e-mail of the designated agent listed above. We, Master Lock Company LLC, acknowledge the applicant’s acceptance of its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Applicant U.S. designated agent Name (Printed): Stephen Gaydos Name (Printed): Stephen Gaydos Title: Compliance Engineer Title: Compliance Engineer Signature: Signature:
LABEL LOCATION 1 Back of Front EUT Label
FCC ID: MZR-YMC624 According to KDB 447498 D04 Interim General RF Exposure Guidance v01 1. SAR-based Exemption A more comprehensive exemption, considering a variable power threshold that depends on both the separation distance and power, is provided in § 1.1307(b)(3)(i)(B). This exemption is applicable to the frequency range between 300 ㎒ and 6 ㎓, with test separation distances between 0.5 ㎝ and 40 ㎝, and for all RF sources in fixed, mobile, and portable device exposure conditions. Accordingly, a RF source is considered an RF exempt device if its available maximum time-averaged (matched conducted) power or its effective radiated power (ERP), whichever is greater, are below a specified threshold. This exemption threshold was derived based on general population 1-g SAR requirements and is detailed in Appendix C. 2. RF Exposure Test Exemptions for Single Source Mode Frequency Range (㎒) Minimum Separation Distance (㎝) Maximum Average Target Power (㏈m) Maximum Tune up (㏈) Maximum Average Output Power Ant. Gain (㏈i) ERP Limits P th (㎽) Ratio 1) Result (㏈m) (㎽) (㏈m) (㎽) Bluetooth Low Energy 2 402 ~ 2 480 20 0 1.5 1.5 1.413 3.19 2.54 1.79 3060 0.001 Pass Note ; - ERP (㏈m) = Maximum average power (㏈m) + Antenna gain (㏈i) -2.15 - Maximum average target power is the manufacturer’s declared rated power. - Maximum average output power = Maximum average target power (㏈m) + Maximum tune up (㏈). 1) A greater value between the ERP(㏈m) and the Maximum average output power(㏈m) is applied. 3. Conclusion: No SAR is required.
Model name: YMC624 Item Contents Antenna Type PIFA Antenna peak gain 3.19 ㏈i Manufacturer / Model name RE Haus Technology / EMICL Printed BT Antenna Address of manufacturer 1-429, 495 Parang-ro, Seo-gu, Incheon, Republic of Korea Test Laboratory 1-429, 495, Parang-ro, Seo-gu, Incheon, Republic of Korea Antenna Length 2.6 cm Antenna Width 0.8 cm Antenna Information Width Length
EMH7081-01A(2024.03.13)(2) A4(210mm*297mm) Test Report No. : F690501-RF-EMC004450 Page : 2 of 26 Contents 1. Test Laboratory .................................................................................................................... 4 1.1 General information ....................................................................................................... 4 2. General Information of E.U.T. .............................................................................................. 5 2.1 Applicant Information .................................................................................................... 5 2.2 General Information of E.U.T. ....................................................................................... 5 2.3 Configurations of E.U.T ................................................................................................. 6 3. E.U.T. Operation and Test Configuration ............................................................................. 7 3.1 Peripheral Equipments .................................................................................................. 7 3.2 Cable List ...................................................................................................................... 7 3.3 Operating Modes and Conditions .................................................................................. 7 3.4 Test System Layout ...................................................................................................... 7 3.5 Modifications to the test items during testing ................................................................. 7 4. Test Results ......................................................................................................................... 8 4.1 Summary ...................................................................................................................... 8 4.2 Note .............................................................................................................................. 8 5. Emission Test ...................................................................................................................... 9 5.1 Test Method and Limits ................................................................................................. 9 5.2 Test Limits..................................................................................................................... 9 5.3 Radiated Emission ...................................................................................................... 11 5.3.1 Test Equipments ................................................................................................ 11 5.3.2 Environment Conditions ..................................................................................... 11 5.3.3 Test Result ........................................................................................................ 12 Appendix A: Measurement Uncertainty ............................................................................. 24 EMH7081-01A(2024.03.13)(2) A4(210mm*297mm) Test Report No. : F690501-RF-EMC004450 Page : 3 of 26 Revision History Revision Report Number Description 0 F690501-RF-EMC004450 Initial EMH7081-01A(2024.03.13)(2) A4(210mm*297mm) Test Report No. : F690501-RF-EMC004450 Page : 4 of 26 1. Test Laboratory 1.1 General information Name SGS Korea Co., Ltd. - Branch Site 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Republic of Korea Tel. +82 31 428 5700 Fax. +82 31 427 5370 - Branch Site-3 35, Giheungdanji-ro 121beon-gil, Giheung-gu, Yongin-si, Gyeonggi-do, Republic of Korea Tel. +82 31 548 0710 Fax. +82 31 548 0719 - Branch Site-4 12, Dongtansandan 10-gil, Hwaseong-si, Gyeonggi-do, 18487, Republic of Korea Tel. +82 31 8007 5302 Fax. +82 31 427 2370 Website http://www.sgsgroup.kr/ee SGS Korea Co., Ltd. has been accredited by the agencies listed in the following table; Accreditation Accreditation bodies Accreditation No. KC MSIT- RRA KR0150 FCC FCC (MRA) ISED ISED (MRA) Vietnam-MIC Vietnam-MIC Japan EMI VCCI C-14102, T-11156, R-13662, G-20037 KOLAS KATS - KOLAS Testing No.123 CBTL IECEE TL 146 SDPPI SDPPI - EMH7081-01A(2024.03.13)(2) A4(210mm*297mm) Test Report No. : F690501-RF-EMC004450 Page : 5 of 26 2. General Information of E.U.T. 2.1 Applicant Information Applicant Master Lock Company LLC Applicant Address 1 Horizon Way Deerfield, IL 60015, United States Manufacturer Master Lock Company LLC Manufacturer Address Lot A10 Ba Thien II Industrial Park Thien Ke Ward Vinh Phuc Province, Vietnam 2.2 General Information of E.U.T. Classification Description Product Name SMART Lock Model Name YMC624-5.5 Alt. Model Name YMC654-5.5, YMC614-5.5, YMC634-5.5, YMC624-4, YMC654-4, YMC614-4, YMC634-4 Model Differences . The difference of Variation models is the presence or absence of key function. No any other difference related to RF function. Brand Key type Keypad Inch Model Remark Yale Keyed Touch screen 5.5 YMC624-5.5 Representative Model (Tested Model) Yale Keyless(Keyfree) Touch screen 5.5 YMC654-5.5 Derived Model Yale Keyed Push button 5.5 YMC614-5.5 Derived Model (Tested Model) Yale Keyless(Keyfree) Push button 5.5 YMC634-5.5 Derived Model Yale Keyed Touch screen 4 YMC624-4 Derived Model Yale Keyless(Keyfree) Touch screen 4 YMC654-4 Derived Model (Tested Model) Yale Keyed Push button 4 YMC614-4 Derived Model Yale Keyless(Keyfree) Push button 4 YMC634-4 Derived Model (Tested Model) . Serial No. - EMI Classification Class B Internal Clock Frequency 2 480 ㎒ (Bluetooth) Rated Power 9 Vd.c. (1.5 V_Battery*6) Tested Power 9 Vd.c. (1.5 V_Battery*6) H/W Version V1.1.6 S/W Version V1.1.6 Port - Components Interior Lock, Exterior Keypad, Deadbolt Strike Plate, Lever Strike plate, Reset Pins, Keys (2 EA), Adjustable Deadbolt, Adjustable Latch Bolt, Screws (a. Small Interior Lock Screw, b. Mounting Plate Screws (2 EA) c. Black Interior Lock Screw, d. Strike Plate and Deadbolt Screws (8 EA) e. Silver Handle Screws (2 EA),…
Text truncated - open the document above for the full version.
1001 SW Disk Drive Suite 250 · Bend, Illinois, 97702 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |
Smart Lock
Equipment Class
DTS - Digital Transmission System
6400
Equipment Class
DTS - Digital Transmission System
4400
Equipment Class
DTS - Digital Transmission System
4401
Equipment Class
DTS - Digital Transmission System
Master Lock Alert
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter