N3F-ST869Data Transceiver

Advanced Tracking Technology Inc.
Data Transceiver - FCC ID N3F-ST869 - Advanced Tracking Technology Inc.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Aug 05, 2002
Application Purpose
Original Equipment
Date of Application
Aug 05, 2002
Equipment Note
Data Transceiver
Frequency Range
902.40000000 - 927.60000000
Company
Advanced Tracking Technology Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Hardware Guide © 2002 ATTI All rights reserved Shadow Tracker Premier TM TM Advanced Tracking Technologies Inc. Copyright © 2002, Advanced Tracking Technologies, Inc. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means without the prior written permission of Advanced Tracking Technologies, Inc. ATTI, Advanced Tracking Technologies, Shadow Tracker, MobilEyes and Time Traveler are trademarks of Advanced Tracking Technologies, Inc., Microsoft, Windows and the Windows logo are registered trademarks of the Microsoft Corporation. Pentium is the registered trademark of Intel Corporation. Other brands and products are trademarks of their prospective holders. www.Advantrack.com Manual Number: M-2869 Federal Communications Commission (FCC) Notification This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment operates in a commercial environment. Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Only peripherals certified to comply with the Class A limits may be attached to this device. Operation with non-certified peripherals or peripherals not recommended by Advanced Tracking Technologies, Inc. is likely to result in interference to radio and television reception. Unauthorized changes or modifications could void the user's authority to operate the equipment. This device must be operated as supplied by Advanced Tracking Technologies, Inc.. Any changes or modifications made to the device without the express written approval of Advanced Tracking Technologies, Inc. may void the user's authority to operate the device. Advanced Tracking Technologies, Inc. is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. CAUTION:The Shadow Tracker Premier has maximum transmitted output power of 200mW. It is required that the transmit antenna (located inside the Shadow Tracker™ Premier) be kept at least 23 cm away from nearby persons to satisfy FCC RF exposure requirements. TC Introduction to MobilEyes1 Connecting the Unit 3 3 4 4 5 5 Safety and Care Instructions7 Specifications of Shadow Tracker Premier8 ™ ™ Mounting and Placement Connecting Power Wiring Instructions Status Indicator Lights GPS Antenna Removing the Unit for Download Other Information6 Trouble Shooting9 TABLE OFCONTENTS Please read this manual completely before use. Thank you for purchasing Shadow Tracker™, the cornerstone of the MobilEyes vehicle tracking system from MobilEyesis a unique hardware and software combination, used for the tracking needs of today’s mobile workforce. ™ Advanced Tracking Technologies, Incorporated. ™ The Shadow Tracker™ Premier uses a stationary system of satellites placed around the globe in orbit by the Department of Defense (DOD). Signals received from one satellite are compared to signals of three others in view. The small differences in reception can be used to calculate the position anywhere on the Earth through triangulation. 1 INTRODUCTION Shadow TrackerPremier™ The Shadow Tracker™ Premier easily installs into a vehicle and use the vehicles electrical system. The unit gathers and stores vital GPS data which is downloaded into the application software providing detailed distance, location and time information necessary for accurately monitoring your mobile staff. Although rare,™ Premier DOD’s procedure of Selective Activation (SA). ™ beyond our control time may appear distorted while a Shadow Trackeris stationary for long periods of time. Data may appear as if the unit has wandered for short distances and/or brief periods of time. This is due to the In addition, there may be other atmospheric circumstances which could cause the Shadow Trackerdata to be unreliable and are. For a listing of the dates and times where problems are a possibility refer to this website: www.laafb.af.mil/SMC/CZ/homepage/ 2 INTRODUCTION Connecting Power The battery on the vehicle serves as the power source for the Shadow Tracker™ units however, if a unit is left on for an extended period in which the vehicle is not running the unit may drain the vehicle battery to the point that the vehicle cannot be started. ™ The adapter should be connected to the vehicles power source. Carefully, connect the receiver adapter to the back of the Shadow Trackerunit paying special attention not to bend any of the connector prongs. Refer to: Wiring Instructions of this manual for further explanation. 3 CONNECTING THEUNIT Mounting and Placement Mounting devices used and the specific placement location of the Shadow TrackerPremier in the vehicle is left to the discretion of the end-user. It is important, when considering the placement location for a unit, to bear in mind that it isthat the transmit antenna (located inside the Shadow TrackerPremier) be kept at least 23 cm away from any nearby persons in order to satisfy FCC RF exposure requirements Note: required ™ ™ The Red wire must be connected to a CONSTANT 12 volt positive power source, it MUST have power even when the vehicle is turned off. The Blue w…

Text truncated - open the document above for the full version.

Cover Letter(s)

July 31, 2002 Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Office of Engineering and Technology Federal Communications Commission Columbia, MD 21046 Applicant: Paul Glass Advanced Tracking Technology Inc. PO Box 168 Sugar Land, TX 77487 Re: Confidentiality for submittal information regarding FCC ID number N3F-ST869 PRODUCT: Spread Spectrum Frequency Hopping Transceiver operating in the 902-928 MHz frequency band under part 15.247. Dear Sirs: Advanced Tracking Technology Inc. requests that the material in the Block diagram, Schematics, and Operational Description be withheld from public disclosure in accordance with Section 0.459 of the Commissions Rules, 47 C.F.R. 0.459 (1998), following grant of the application. In support of this request, Advanced Tracking Technology Inc. submits the following: 1. Identification of the specific information for which confidential treatment is sought: The materials set fourth in the Operational Description, Block Diagram, and Schematics, which are segregated from the non-confidential exhibits of the application, are those for which confidentiality is sought. 2. Identification of the Commission proceeding in which the information was submitted or a description of the circumstances giving rise to the submission: The proceeding is that involving the application for equipment authorization (certification) under FCC ID No: N3F-ST869 3. Explanation of the degree to which the information is commercial or financial, or contains a trade secret or is privileged: ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 This material includes a detailed theory of operation and circuit diagrams, (schematic diagrams). As such, this material is treated as highly confidential business information. 4. Explanation of the degree to which the information concerns a service that is subject to competition: The material for which confidentiality is sought is employed in the design and manufacture of this low power transmitting equipment that is offered on a highly competitive basis. Customers for this equipment have a variety of competing sources. 5. Explanation of how disclosure of the information could result in substantial competitive harm: Disclosure would, in effect, give away the fruits of the labors of Advanced Tracking Technology Inc.’s engineering personnel, who have designed the equipment and the manufacturing process. Disclosure would also offer competitors additional unwarranted insight into the state of the product development, thereby allowing competitors an advantage, not available to Advanced Tracking Technology Inc. 6. Identification of any measures taken by the submitting party to prevent unauthorized disclosure: The information for which confidential treatment is sought is kept confidential by Advanced Tracking Technology Inc. and not made available to third parties except pursuant to non-disclosure agreements. 7. Identification of whether the information is available to the public and the extent of any previous disclosure of the information to third parties: To the knowledge of those preparing this application, the information has not been disclosed publicly heretofore. While the general theory of operation of this equipment has been the subject of numerous disclosures in industry and standards groups as well as in rule making proceedings of the FCC, the protection sought is narrowly drawn and pertains to certain specific implementations of the low power radio technology. 8. Justification of the period during which the submitting party asserts that the material should not be available for public disclosure: This material should not be disclosed for at least 25 years. While improvements in design are made relatively frequently, disclosure of the design information would lead to insights into both design and manufacturing techniques that could have an adverse competitive effect for many years to come. This equipment is designed for commercial, industrial, and governmental applications. As such, unlike most consumer equipment, this equipment will be used for more than a decade in some cases. Moreover, this equipment will be used in revenue collection and secure access control applications (e.g. volume and pressurized piping facilities). As such, it is important that the design not be made available to unauthorized persons who might attempt to use knowledge of the design to compromise the applications for which the equipment will be employed. 9. Any other information that the party seeking confidential treatment believes may be useful in assessing whether its request for confidentiality should be granted: See item 8 above. Note that the equipment for which approval is being sought will be employed in applications that inherently place a premium on security. Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers

External Photos

ROGERS LABS, INC. Advanced Tracking Technology Inc. 4405 W. 259th Terrace MODEL: ST-869 Shadow Tracker Premier Louisburg, KS 66053 Test #: 02725A FCCID#: N3F-ST869 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 15C Page 1 of 1 ST869ExtPho 07/30/2002 External Photos of ST-869.

ID Label/Location Info

ROGERS LABS, INC. Advanced Tracking Technology Inc. 4405 W. 259th Terrace MODEL: ST-869 Shadow Tracker Premier Louisburg, KS 66053 Test #: 02725A FCCID#: N3F-ST869 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 15C Page 1 of 1 ST869IdLbl.doc 07/30/2002 FCC ID Label Location and information for ST-869

Internal Photos

ROGERS LABS, INC. Advanced Tracking Technology Inc. 4405 W. 259th Terrace MODEL: ST-869 Shadow Tracker Premier Louisburg, KS 66053 Test #: 02725A FCCID#: N3F-ST869 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 15C Page 1 of 2 ST869IntPho.doc 07/30/2002 Internal Photographs of ST-869. ROGERS LABS, INC. Advanced Tracking Technology Inc. 4405 W. 259th Terrace MODEL: ST-869 Shadow Tracker Premier Louisburg, KS 66053 Test #: 02725A FCCID#: N3F-ST869 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 15C Page 2 of 2 ST869IntPho.doc 07/30/2002

Test Report

ENGINEERING TEST REPORT FOR APLLICATION of GRANT of CERTIFICATION FOR CFR 47, PART 15C - INTENTIONAL RADIATORS Paragraph 15.247 Spread Spectrum Frequency Hopping Transmitter For Advanced Tracking Technology Inc. PO Box 168 Sugar Land, TX 77487 Paul Glass, SHADOW TRACKER PREMIER Model: ST-869 Frequency 902-928 MHz FCC ID#: N3F-ST869 Test Date: July 25, 2002 Certifying Engineer: Scot D. Rogers ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone: (913) 837-3214 FAX: (913) 837-3214 This report shall not be reproduced except in full, without the written approval of the laboratory. This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214 NVLAP Accredited Laboratory NVLAP Lab Code: 200087-0 ROGERS LABS, INC. Advanced Tracking Technology Inc. 4405 W. 259th Terrace MODEL: ST-869 SHADOW TRACKER PREMIER Louisburg, KS 66053 Test #: 02725A FCCID#: N3F-ST869 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 15c (15.247) Page 2 of 29 SahdowTrackerPremierTstRpt.doc 7/31/2002 TABLE OF CONTENTS FORWARD:.............................................................................................................3 1) APPLICABLE STANDARDS & TEST PROCEDURES.......................................3 2.1033(b) Application for Certification....................................................................................................4 2) EQUIPMENT TESTED......................................................................................5 3) EQUIPMENT FUNCTION AND TESTING PROCEDURES................................5 4) EQUIPMENT AND CABLE CONFIGURATIONS................................................5 Conducted Emission Test Procedure............................................................................................................5 Radiated Emission Test Procedure:.............................................................................................................6 5) LIST OF TEST EQUIPMENT............................................................................6 6) UNITS OF MEASUREMENTS...........................................................................7 7) TEST SITE LOCATIONS..................................................................................7 8) SUBPART B – UNINTENTIONAL RADIATORS................................................8 Conducted EMI.............................................................................................................................................8 Radiated EMI.............................................................................................................................................10 Conducted (7 Highest Emissions)...............................................................................................................14 Data: General Radiated Emissions from EUT (6 Highest Emissions).........................................................14 Summary of Results for Conducted Emissions...........................................................................................14 Summary of Results for Radiated Emissions..............................................................................................15 Statement of Modifications and Deviations................................................................................................15 9) SUBPART C - INTENTIONAL RADIATORS....................................................15 15.203 Antenna Requirements....................................................................................................................15 15.205 Restricted Bands of Operation........................................................................................................15 Data: Emissions in Restricted Bands..........................................................................................................16 Summary of Results for Radiated Emissions in Restricted Bands:...........................................................16 15.209 Radiated Emissions Limits; General Requirements.......................................................................16 Radiated EMI.............................................................................................................................................16 Data: General Radiated Emissions from EUT (6 Highest Emissions).........................................................18 Summary of Results for Radiated Emissions:............................................................................................18 15.247 Operation in the Band 902-928 MHz..............................................................................................18 Data: Radiated Emissions from EUT..........................................................................................................24 Data: Radiated Emissions and substitution power required.........................................................................25 Summary of Results for Radiated Emissions of Intentional Radiator.......................................................25 Statement of Modifications and Deviations................................................................................................25 NVLAP Accredited Laboratory NVLAP Lab Code: 200087-0 ROGERS LABS, INC. Advanced Tracking Technology Inc. 4405 W. 259th Terrace MODEL: ST-869 SHADOW TRACKER PREMIER Louisburg, KS 66053 Test #: 02725A FCCID#: N3F-ST869 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 15c (15.247) Page 3 of 29 SahdowTrackerPremierTstRpt.doc 7/31/2002 FORWARD: The following is submitted for consideration in obtaining a Grant of Certification for spread spectrum intentional radiators per CFR Paragraph 15.247. Name of Applicant: Advanced Tracking Technology Inc. PO Box 168 Sugar Land, TX 77487 Model: ST-869 Spread Spectrum Frequency Hopping Transmitter. FCC I.D.: N3F-ST869. Frequency Range: …

Text truncated - open the document above for the full version.

Test Setup Photos

ROGERS LABS, INC. Advanced Tracking Technology Inc. 4405 W. 259th Terrace MODEL: ST-869 Shadow Tracker Premier Louisburg, KS 66053 Test #: 02725A FCCID#: N3F-ST869 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 15C Page 1 of 2 ST869Tsup.doc 07/30/2002 Test Setup Photographs EUT ROGERS LABS, INC. Advanced Tracking Technology Inc. 4405 W. 259th Terrace MODEL: ST-869 Shadow Tracker Premier Louisburg, KS 66053 Test #: 02725A FCCID#: N3F-ST869 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 15C Page 2 of 2 ST869Tsup.doc 07/30/2002

Contact Information

Applicant

Paul M. Glass(President)
800-279-0035

Test Firm

Rogers Labs, Inc.Scot Rogers
[email protected]913-837-3214Fax: 913-837-3214

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.4 MHz - 927.6 MHz200.00 mW
Confidentiality
Long Term
Grant Notes
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Advanced Tracking Technology Inc.

Transceiver Module - FCC ID N3F-ATTI201 - Advanced Tracking Technology Inc.
N3F-ATTI201

Transceiver Module

Jul 13, 2006

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter