Date: June 24, 2025 Rev: 0.2 HACS-F041 Covered List Attestation Letter HCT America, Inc. ([email protected]) 840 Yosemite Way Milpitas, CA 95035 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 1 of 3 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America INC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America INC Covered List Attestation Letter Date: June 24, 2025 Rev: 0.2 HACS-F041 Covered List Attestation Letter HCT America, Inc. ([email protected]) 840 Yosemite Way Milpitas, CA 95035 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 2 of 3 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America INC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America INC REVISION TABLE Rev Description of Change Date Approved 0.0 Original Release 07/15/2024 QM 0.1 Updated address 05/12/2025 QM 0.2 Adding Kaspersky 06/24/2025 QM
Date : May. 1 2, 2025 Rev : 2.5 HACS-F004 FCC Agent Authorization Letter HCT America, Inc. ([email protected]) 840 Yosemite Way Milpitas, CA 95035 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 1 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America INC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America INC FCC Agent Authorization Letter Date : May. 1 2, 2025 Rev : 2.5 HACS-F004 FCC Agent Authorization Letter HCT America, Inc. ([email protected]) 840 Yosemite Way Milpitas, CA 95035 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 2 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America INC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America INC REVISION TABLE Rev Description of Change Date Approved 1.0 Original Release(Obsolete) 06/14/2012 QM 2.0 Updated template(Obsolete) 10/01/2012 QM 2.1 Updated address(Obsolete) 01/10/2014 QM 2.2 Updated address 11/18/2016 QM 2.3 Fixed Typo “Agent” 11/09/2017 QM 2.4 Update company name and editorial modification 7/15/2024 QM 2.5 Updated address 05/12/2025 QM
Date: May 12, 2025 Rev: 3.2 HACS-F003 FCC Confidentiality Request Letter HCT America, Inc. ([email protected]) 840 Yosemite Way Milpitas, CA 95035 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 1 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America INC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America INC. FCC Confidentiality Request Letter Date: May 12, 2025 Rev: 3.2 HACS-F003 FCC Confidentiality Request Letter HCT America, Inc. ([email protected]) 840 Yosemite Way Milpitas, CA 95035 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 2 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America INC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America INC. REVISION TABLE Rev Description of Change Date Approved 1.0 Original Release(Obsolete) 06/14/2012 QM 2.0 Updated template(Obsolete) 10/01/2012 QM 2.1 Updated address(Obsolete) 01/10/2014 QM 2.2 Updated address 11/18/2016 QM 3.0 Updated LTC and STC Confidentiality table 11/09/2017 QM 3.1 Update company name and editorial modification 7/15/2024 QM 3.2 Updated address 05/12/2025 QM
PSR-U-9533-N FCC/IC Label
TEST REPORT FCC MPE Test for PSR-U-9533-N Certification APPLICANT ADRF KOREA, Inc. REPORT NO. HCT-RF-2605-FC002 DATE OF ISSUE May 11, 2026 Tested by Kyung Soo Kang Technical Manager Jong Seok Lee F-TP22-03(Rev.06) 1 / 6 The report shall not be (partly) reproduced except in full without approval of the laboratory. HCT CO., LTD.2-6, 73, 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea Tel. +82 31 645 6300 Fax. +82 31 645 6401 The report shall not be (partly) reproduced except in full without approval of the laboratory. F-TP22-03 (Rev. 06) Page 2 of 6 HCT CO.,LTD. 2-6, 73, 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea Tel. +82 31 645 6300 Fax. +82 31 645 6401 TEST REPORT REPORT NO. HCT-RF-2605-FC002 DATE OF ISSUE May 11, 2026 A pplicantADRF KOREA, Inc. 196-16 IYEO-RO BAEKSA-MYEON ICHEON-SI, GYEONGGI-DO, 17316, KOREA Product Name Model Name BDA PSR-U-9533-N FCC IDN52-PSR-U-9533-N Date of TestFebruary 3, 2026 ~ May 8, 2026 Location of TestӍ Permanent Testing Lab ӎ On Site Testing (Address: 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi- do, Republic of Korea) Test Standard UsedCFR 47 Part 2.1091 Test ResultsPASS The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC002 F-TP22-03 (Rev. 06) Page 3 of 6 REVISION HISTORY The revision history for this test report is shown in table. Revision No. Date of Issue Description 0 May 11, 2026 Initial Release Notice Content Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules under normal use and maintenance. The results shown in this test report only apply to the sample(s), as received, provided by the applicant, unless otherwise stated. The test results have only been applied with the test methods required by the standard(s). The laboratory is not accredited for the test results marked *. Information provided by the applicant is marked **. Test results provided by external providers are marked ***. When confirmation of authenticity of this test report is required, please contact www.hct.co.kr The test results in this test report are not associated with the ((KS Q) ISO/IEC 17025) accreditation by KOLAS (Korea Laboratory Accreditation Scheme) / A2LA (American Association for Laboratory Accreditation) that are under the ILAC (International Laboratory Accreditation Cooperation) Mutual Recognition Agreement (MRA). The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC002 F-TP22-03 (Rev. 06) Page 4 of 6 RF Exposure Statement 1. LIMITS According to §1.1310 and §2.1091 RF exposure is calculated. (B) Limits for General Population/Uncontrolled Exposures Frequency range (MHz) Electric field Strength (V/m) Magnetic field Strength (A/m) Power density (mW/cm²) Averaging time (minutes) 0.3 - 1.34 1.34 - 30 30 - 300 300 - 1500 1500 - 100.000 614 824/f 27.5 1.63 2.19/f 0.073 #) (100) #) (180/f²) 0.2 f/1500 1.0 30 30 30 30 30 F = frequency in MHz # = Plane-wave equivalent power density 2. MAXIMUM PERMISSIBLE EXPOSURE Prediction Prediction of MPE limit at a given distance S = PG/4πR² S = Power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC002 F-TP22-03 (Rev. 06) Page 5 of 6 3. RESULTS [Uplink] - UHF (406.1 ~ 420 MHz) Maximum output Power at antenna input terminal 27.50 dBm Maximum output Power at antenna input terminal 562.34 mW Prediction distance 40.00 cm Prediction frequency 406.10 MHz Antenna Gain(typical) 9.15 dBi Antenna Gain(numeric) 8.22 - Power density at prediction frequency(S) 0.2300 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.2707 mW/cm 2 - UHF (421 ~ 430 MHz) Maximum output Power at antenna input terminal 27.50 dBm Maximum output Power at antenna input terminal 562.34 mW Prediction distance 40.00 cm Prediction frequency 421.00 MHz Antenna Gain(typical) 9.15 dBi Antenna Gain(numeric) 8.22 - Power density at prediction frequency(S) 0.2300 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.2807 mW/cm 2 - UHF (450 ~ 512 MHz) Maximum output Power at antenna input terminal 27.50 dBm Maximum output Power at antenna input terminal 562.34 mW Prediction distance 40.00 cm Prediction frequency 450.00 MHz Antenna Gain(typical) 10.15 dBi Antenna Gain(numeric) 10.35 - Power density at prediction frequency(S) 0.2895 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.3000 mW/cm 2 The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC002 F-TP22-03 (Rev. 06) Page 6 of 6 [Downlink] - UHF (406.1 ~ 420 MHz) Maximum output Power at antenna input terminal 33.50 dBm Maximum output Power at antenna input terminal 2 238.72 mW Prediction distance 40.00 cm Prediction frequency 406.10 MHz Antenna Gain(typical) 1.50 dBi Antenna Gain(numeric) 1.41 - Power density at prediction frequency(S) 0.1573 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.2707 mW/cm 2 - UHF (421 ~ 430 MHz) Maximum output Power at antenna input terminal 33.50 dBm Maximum output Power at antenna input terminal 2 238.72 mW Prediction distance 40.00 cm Prediction frequency 421.00 MHz Antenna Gain(…
Text truncated - open the document above for the full version.
TEST REPORT FCC Test for PSR-U-9533-N Certification APPLICANT ADRF KOREA, Inc. REPORT NO. HCT-RF-2605-FC001 DATE OF ISSUE May 11, 2026 Tested by Kyung Soo Kang Technical Manager Jong Seok Lee F-TP22-03(Rev.06) 1 / 190 The report shall not be (partly) reproduced except in full without approval of the laboratory. HCT CO., LTD.2-6, 73, 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea Tel. +82 31 645 6300 Fax. +82 31 645 6401 The report shall not be (partly) reproduced except in full without approval of the laboratory. F-TP22-03 (Rev. 06) Page 2 of 190 HCT CO.,LTD. 2-6, 73, 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea Tel. +82 31 645 6300 Fax. +82 31 645 6401 TEST REPORT REPORT NO. HCT-RF-2605-FC001 DATE OF ISSUE May 11, 2026 A pplicantADRF KOREA, Inc. 196-16 IYEO-RO BAEKSA-MYEON ICHEON-SI, GYEONGGI-DO, 17316, KOREA Product Name Model Name BDA PSR-U-9533-N FCC IDN52-PSR-U-9533-N Date of TestFebruary 3, 2026 ~ May 8, 2026 Location of TestӍ Permanent Testing Lab ӎ On Site Testing (Address: 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi- do, Republic of Korea) Test Standard UsedCFR 47 Part 2, Part 90 Test ResultsPASS The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 3 of 190 REVISION HISTORY The revision history for this test report is shown in table. Revision No. Date of Issue Description 0 May 11, 2026 Initial Release Notice Content Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules under normal use and maintenance. The results shown in this test report only apply to the sample(s), as received, provid ed by the applicant, unless otherwise stated. The test results have only been applied with the test methods required by the standard(s). The laboratory is not accredited for the test results marked *. Information provided by the applicant is marked **. Test results provided by external providers are marked ***. When confirmation of authenticity of this test report is required, please contact www.hct.co.kr The test results in this test report are not associated with the ((KS Q) ISO/IEC 17025) accreditation by KOLAS (Korea Laboratory Accreditation Scheme) / A2LA (American Association for Laboratory Accreditation) that are under the ILAC (International Laboratory Accreditation Cooperation) Mutual Recognition Agreement (MRA). The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 4 of 190 CONTENTS 1. GENERAL INFORMATION 5 1.1. APPLICANT INFORMATION 5 1.2. PRODUCT INFORMATION 5 1.3. TEST INFORMATION 5 2. FACILITIES AND ACCREDITATIONS 6 2.1. FACILITIES 6 2.2. EQUIPMENT 6 3. TEST SPECIFICATIONS 7 3.1. STANDARDS 7 3.2. ADDITIONAL DESCRIPTIONS ABOUT TEST 8 3.3. MEASUREMENTUNCERTAINTY 10 3.4. STANDARDS ENVIRONMENTAL TEST CONDITIONS 10 3.5. TEST DIAGRAMS 11 4. TEST EQUIPMENTS 13 5. TEST RESULT 14 5.1. AGC THRESHOLD 14 5.2. OUT-OF-BAND REJECTION 16 5.3. OCCUPIED BANDWIDTH 21 5.4. INPUT-VERSUS-OUTPUT SIGNAL COMPARISON 82 5.5. INPUT/OUTPUT POWER AND AMPLIFIER/BOOSTER GAIN 140 5.6. NOISE FIGURE 155 5.7. OUT-OF-BAND/OUT-OF-BLOCK EMISSIONS AND SPURIOUS EMISSIONS 161 5.8. RADIATED SPURIOUS EMISSIONS 179 5.9. FREQUENCY STABILITY 182 6. Annex A_EUT AND TEST SETUP PHOTO 190 The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 5 of 190 1. GENERAL INFORMATION 1.1. APPLICANT INFORMATION Company Name ADRF KOREA, Inc. Company Address 196-16 IYEO-RO BAEKSA-MYEON ICHEON-SI, GYEONGGI-DO, 17316, KOREA 1.2. PRODUCT INFORMATION EUT Type BDA EUT Serial Number PSRU9533NXXXXXX Power Supply AC 110~220 Vac Frequency Range Band Name Uplink / Downlink (MHz) UHF 406.1 ~ 420 421 ~ 430 450 ~ 512 Tx Output Power Band Name Uplink Downlink UHF 27 dBm 33 dBm Antenna Peak Gain Band Name Uplink Downlink UHF (406.1 ~ 420 MHz) 9.15 dBi 7 dBd 1.5 dBi -0.65 dBd UHF (421 ~ 430 MHz) UHF (450 ~ 512 MHz) 10.15 dBi 8 dBd 1.3. TEST INFORMATION FCC Rule Parts CFR 47 Part 2, Part 90 Measurement Standards KDB 935210 D05 v01r04, KDB 971168 D01 v03r01, ANSI C63.26-2015 Test Location 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 6 of 190 2. FACILITIES AND ACCREDITATIONS 2.1. FACILITIES The SAC(Semi-Anechoic Chamber) and conducted measurement facility used to collect the radiated data are located at the 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea. The site is constructed in conformance with the requirements of ANSI C63.4. (Version :2014) and CISPR Publication 22. Detailed description of test facility was submitted to the Commission and accepted dated February 26, 2026(Registration Number: KR0032). 2.2. EQUIPMENT Radiated emissions are measured with one or more of the following types of linearly polarized antennas: tuned dipole, bi-conical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum analyzers with pre-selectors and quasi-peak detectors are used to perform radiated measurements. Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for making measurements. All receiving equipment conforms to CISPR Publication 16-1, ˑRadio Interference Measuring Apparatus and…
Text truncated - open the document above for the full version.
The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 93 of 190 Input @ + 3 dB AGC threshold / UHF (406.1 ~ 420) / Uplink / FM (25 kHz) / Mask C Output @ + 3 dB AGC threshold / UHF (406.1 ~ 420) / Uplink / FM (25 kHz) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 94 of 190 Input / UHF (421 ~ 430) / Uplink / P25 Phase 1 (C4FM) / Mask D Output / UHF (421 ~ 430) / Uplink / P25 Phase 1 (C4FM) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 95 of 190 Input @ + 3 dB AGC threshold / UHF (421 ~ 430) / Uplink / P25 Phase 1 (C4FM) / Mask D Output @ + 3 dB AGC threshold / UHF (421 ~ 430) / Uplink / P25 Phase 1 (C4FM) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 96 of 190 Input / UHF (421 ~ 430) / Uplink / P25 Phase 2 (H-CPM) / Mask D Output / UHF (421 ~ 430) / Uplink / P25 Phase 2 (H-CPM) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 97 of 190 Input @ + 3 dB AGC threshold / UHF (421 ~ 430) / Uplink / P25 Phase 2 (H-CPM) / Mask D Output @ + 3 dB AGC threshold / UHF (421 ~ 430) / Uplink / P25 Phase 2 (H-CPM) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 98 of 190 Input / UHF (421 ~ 430) / Uplink / FM (12.5 kHz) / Mask D Output / UHF (421 ~ 430) / Uplink / FM (12.5 kHz) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 99 of 190 Input @ + 3 dB AGC threshold / UHF (421 ~ 430) / Uplink / FM (12.5 kHz) / Mask D Output @ + 3 dB AGC threshold / UHF (421 ~ 430) / Uplink / FM (12.5 kHz) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 100 of 190 Input / UHF (421 ~ 430) / Uplink / FM (25 kHz) / Mask C Output / UHF (421 ~ 430) / Uplink / FM (25 kHz) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 101 of 190 Input @ + 3 dB AGC threshold / UHF (421 ~ 430) / Uplink / FM (25 kHz) / Mask C Output @ + 3 dB AGC threshold / UHF (421 ~ 430) / Uplink / FM (25 kHz) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 102 of 190 Input / UHF (450 ~ 512) / Uplink / P25 Phase 1 (C4FM) / Mask D Output / UHF (450 ~ 512) / Uplink / P25 Phase 1 (C4FM) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 103 of 190 Input @ + 3 dB AGC threshold / UHF (450 ~ 512) / Uplink / P25 Phase 1 (C4FM) / Mask D Output @ + 3 dB AGC threshold / UHF (450 ~ 512) / Uplink / P25 Phase 1 (C4FM) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 104 of 190 Input / UHF (450 ~ 512) / Uplink / P25 Phase 2 (H-CPM)/ Mask D Output / UHF (450 ~ 512) / Uplink / P25 Phase 2 (H-CPM)/ Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 105 of 190 Input @ + 3 dB AGC threshold / UHF (450 ~ 512) / Uplink / P25 Phase 2 (H-CPM)/ Mask D Output @ + 3 dB AGC threshold / UHF (450 ~ 512) / Uplink / P25 Phase 2 (H-CPM)/ Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 106 of 190 Input / UHF (450 ~ 512) / Uplink / FM (12.5 kHz) / Mask D Output / UHF (450 ~ 512) / Uplink / FM (12.5 kHz) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 107 of 190 Input @ + 3 dB AGC threshold / UHF (450 ~ 512) / Uplink / FM (12.5 kHz) / Mask D Output @ + 3 dB AGC threshold / UHF (450 ~ 512) / Uplink / FM (12.5 kHz) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 108 of 190 Input / UHF (450 ~ 512) / Uplink / FM (25 kHz) / Mask C Output / UHF (450 ~ 512) / Uplink / FM (25 kHz) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 109 of 190 Input @ + 3 dB AGC threshold / UHF (450 ~ 512) / Uplink / FM (25 kHz) / Mask C Output @ + 3 dB AGC threshold / UHF (450 ~ 512) / Uplink / FM (25 kHz) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 110 of 190 Input / UHF (406.1 ~ 420) / Downlink / P25 Phase 1 (C4FM) / Mask C Output / UHF (406.1 ~ 420) / Downlink / P25 Phase 1 (C4FM) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 111 of 190 Input @ + 3 dB AGC threshold / UHF (406.1 ~ 420) / Downlink / P25 Phase 1 (C4FM) / Mask C Output @ + 3 dB AGC threshold / UHF (406.1 ~ 420) / Downlink / P25 Phase 1 (C4FM) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 112 of 190 Input / UHF (406.1 ~…
Text truncated - open the document above for the full version.
The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 163 of 190 Test Results: Plot data of Out-of-band/out-of-block emissions Out-of-band (two adjacent test signals) / UHF (406.1 ~ 420) / Uplink / 12.5kHz +3 dB above Out-of-band (two adjacent test signals) / UHF (406.1 ~ 420) / Uplink / 12.5kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 164 of 190 Out-of-band (two adjacent test signals) / UHF (406.1 ~ 420) / Uplink / 25kHz +3 dB above Out-of-band (two adjacent test signals) / UHF (406.1 ~ 420) / Uplink / 25kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 165 of 190 Out-of-band (two adjacent test signals) / UHF (421 ~ 430) / Uplink / 12.5kHz +3 dB above Out-of-band (two adjacent test signals) / UHF (421 ~ 430) / Uplink / 12.5kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 166 of 190 Out-of-band (two adjacent test signals) / UHF (421 ~ 430) / Uplink / 25kHz +3 dB above Out-of-band (two adjacent test signals) / UHF (421 ~ 430) / Uplink / 25kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 167 of 190 Out-of-band (two adjacent test signals) / UHF (450 ~ 512) / Uplink / 12.5kHz +3 dB above Out-of-band (two adjacent test signals) / UHF (450 ~ 512) / Uplink / 12.5kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 168 of 190 Out-of-band (two adjacent test signals) / UHF (450 ~ 512) / Uplink / 25kHz +3 dB above Out-of-band (two adjacent test signals) / UHF (450 ~ 512) / Uplink / 25kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 169 of 190 Out-of-band (two adjacent test signals) / UHF (406.1 ~ 420) / Downlink / 12.5kHz +3 dB above Out-of-band (two adjacent test signals) / UHF (406.1 ~ 420) / Downlink / 12.5kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 170 of 190 Out-of-band (two adjacent test signals) / UHF (406.1 ~ 420) / Downlink / 25kHz +3 dB above Out-of-band (two adjacent test signals) / UHF (406.1 ~ 420) / Downlink / 25kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 171 of 190 Out-of-band (two adjacent test signals) / UHF (421 ~ 430) / Downlink / 12.5kHz +3 dB above Out-of-band (two adjacent test signals) / UHF (421 ~ 430) / Downlink / 12.5kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 172 of 190 Out-of-band (two adjacent test signals) / UHF (421 ~ 430) / Downlink / 25kHz +3 dB above Out-of-band (two adjacent test signals) / UHF (421 ~ 430) / Downlink / 25kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 173 of 190 Out-of-band (two adjacent test signals) / UHF (450 ~ 512) / Downlink / 12.5kHz +3 dB above Out-of-band (two adjacent test signals) / UHF (450 ~ 512) / Downlink / 12.5kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 174 of 190 Out-of-band (two adjacent test signals) / UHF (450 ~ 512) / Downlink / 25kHz +3 dB above Out-of-band (two adjacent test signals) / UHF (450 ~ 512) / Downlink / 25kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 175 of 190 Plot data of Spurious Emissions Spurious / UHF (406.1 ~ 420) / Uplink Spurious / UHF (421 ~ 430) / Uplink The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 176 of 190 Spurious / UHF (450 ~ 512) / Uplink Note: Only the worst case plot for simultaneous spurious emissions. The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 177 of 190 Spurious / UHF (406.1 ~ 420) / Downlink Spurious / UHF (421 ~ 430) / Downlink The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 178 of 190 Spurious / UHF (450 ~ 512) / Downlink Note: Only the worst case plot for simultaneous spurious emissions. The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC001 F-TP22-03 (Rev. 06) Page 179 of 190 5.8. RADIATED SPURIOUS EMISSIONS Test Requirements: § 2.1053 Measurements required: Field strength of spurious radiation. (a) Measurements shall be made to detect spurious emissions that may be radiated directly from the cabinet, control circuits, power leads, or intermediate circuit elements under normal conditions of installation and operation. Curves or equivalent data shall be supplied showing the magnitude of each harmonic and other spurious emission. For this test, single sideband, independent sideband, and controlled carrier transmitters shall be modulated under the conditions specified in paragraph (c) of §2.1049, as appropriate. For equipment operating on frequencies below 890 MHz, an open field test is normally required, with the measuring instrument antenna located in the far-field at all test …
Text truncated - open the document above for the full version.
3116 W Vanowen St. · Burbank, 91505 · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 9 | 406.1 MHz - 420 MHz | 562.00 mW | F1W | Amp |
| 2 | 9 | 421 MHz - 430 MHz | 532.00 mW | F1W | Amp |
| 3 | 9 | 450 MHz - 512 MHz | 533.00 mW | F1W | Amp |
| 4 | 9 | 406.1 MHz - 420 MHz | 2.234 W | F1W | Amp |
| 5 | 9 | 421 MHz - 430 MHz | 2.158 W | F1W | Amp |
| 6 | 9 | 450 MHz - 512 MHz | 2.07 W | F1W | Amp |
Equipment Class
B9A - Part 90 Class A Industrial Booster (non-SMR)Equipment Class
B9B - Part 90 Class B Industrial Booster (non-SMR)Equipment Class
B9B - Part 90 Class B Industrial Booster (non-SMR)Equipment Class
B9A - Part 90 Class A Industrial Booster (non-SMR)Public Safety Repeater
Equipment Class
B9A - Part 90 Class A Industrial Booster (non-SMR)