Date: June 24, 2025 Rev: 0.2 HACS-F041 Covered List Attestation Letter HCT America, Inc. ([email protected]) 840 Yosemite Way Milpitas, CA 95035 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 1 of 3 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America INC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America INC Covered List Attestation Letter Date: June 24, 2025 Rev: 0.2 HACS-F041 Covered List Attestation Letter HCT America, Inc. ([email protected]) 840 Yosemite Way Milpitas, CA 95035 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 2 of 3 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America INC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America INC REVISION TABLE Rev Description of Change Date Approved 0.0 Original Release 07/15/2024 QM 0.1 Updated address 05/12/2025 QM 0.2 Adding Kaspersky 06/24/2025 QM
Date : May. 1 2, 2025 Rev : 2.5 HACS-F004 FCC Agent Authorization Letter HCT America, Inc. ([email protected]) 840 Yosemite Way Milpitas, CA 95035 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 1 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America INC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America INC FCC Agent Authorization Letter Date : May. 1 2, 2025 Rev : 2.5 HACS-F004 FCC Agent Authorization Letter HCT America, Inc. ([email protected]) 840 Yosemite Way Milpitas, CA 95035 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 2 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America INC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America INC REVISION TABLE Rev Description of Change Date Approved 1.0 Original Release(Obsolete) 06/14/2012 QM 2.0 Updated template(Obsolete) 10/01/2012 QM 2.1 Updated address(Obsolete) 01/10/2014 QM 2.2 Updated address 11/18/2016 QM 2.3 Fixed Typo “Agent” 11/09/2017 QM 2.4 Update company name and editorial modification 7/15/2024 QM 2.5 Updated address 05/12/2025 QM
Date: May 12, 2025 Rev: 3.2 HACS-F003 FCC Confidentiality Request Letter HCT America, Inc. ([email protected]) 840 Yosemite Way Milpitas, CA 95035 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 1 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America INC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America INC. FCC Confidentiality Request Letter Date: May 12, 2025 Rev: 3.2 HACS-F003 FCC Confidentiality Request Letter HCT America, Inc. ([email protected]) 840 Yosemite Way Milpitas, CA 95035 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 2 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America INC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America INC. REVISION TABLE Rev Description of Change Date Approved 1.0 Original Release(Obsolete) 06/14/2012 QM 2.0 Updated template(Obsolete) 10/01/2012 QM 2.1 Updated address(Obsolete) 01/10/2014 QM 2.2 Updated address 11/18/2016 QM 3.0 Updated LTC and STC Confidentiality table 11/09/2017 QM 3.1 Update company name and editorial modification 7/15/2024 QM 3.2 Updated address 05/12/2025 QM
PSR-V-9533-N FCC/IC Label
TEST REPORT FCC MPE Test for PSR-V-9533-N Certification APPLICANT ADRF KOREA, Inc. REPORT NO. HCT-RF-2605-FC014 DATE OF ISSUE May 14, 2026 Tested by Kyung Soo Kang Technical Manager Jong Seok Lee F-TP22-03(Rev.06) 1 / 5 The report shall not be (partly) reproduced except in full without approval of the laboratory. HCT CO., LTD.2-6, 73, 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea Tel. +82 31 645 6300 Fax. +82 31 645 6401 The report shall not be (partly) reproduced except in full without approval of the laboratory. F-TP22-03 (Rev. 06) Page 2 of 5 HCT CO.,LTD. 2-6, 73, 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea Tel. +82 31 645 6300 Fax. +82 31 645 6401 TEST REPORT REPORT NO. HCT-RF-2605-FC014 DATE OF ISSUE May 14, 2026 A pplicantADRF KOREA, Inc. 196-16 IYEO-RO BAEKSA-MYEON ICHEON-SI, GYEONGGI-DO, 17316, KOREA Product Name Model Name BDA PSR-V-9533-N FCC IDN52-PSR-V-9533-N Date of TestFebruary 25, 2026 ~ May 14, 2026 Location of TestӍ Permanent Testing Lab ӎ On Site Testing (Address: 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi- do, Republic of Korea) Test Standard UsedCFR 47 Part 2.1091 Test ResultsPASS The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC014 F-TP22-03 (Rev. 06) Page 3 of 5 REVISION HISTORY The revision history for this test report is shown in table. Revision No. Date of Issue Description 0 May 14, 2026 Initial Release Notice Content Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules under normal use and maintenance. The results shown in this test report only apply to the sample(s), as received, provided by the applicant, unless otherwise stated. The test results have only been applied with the test methods required by the standard(s). The laboratory is not accredited for the test results marked *. Information provided by the applicant is marked **. Test results provided by external providers are marked ***. When confirmation of authenticity of this test report is required, please contact www.hct.co.kr The test results in this test report are not associated with the ((KS Q) ISO/IEC 17025) accreditation by KOLAS (Korea Laboratory Accreditation Scheme) / A2LA (American Association for Laboratory Accreditation) that are under the ILAC (International Laboratory Accreditation Cooperation) Mutual Recognition Agreement (MRA). The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC014 F-TP22-03 (Rev. 06) Page 4 of 5 RF Exposure Statement 1. LIMITS According to §1.1310 and §2.1091 RF exposure is calculated. (B) Limits for General Population/Uncontrolled Exposures Frequency range (MHz) Electric field Strength (V/m) Magnetic field Strength (A/m) Power density (mW/cm²) Averaging time (minutes) 0.3 - 1.34 1.34 - 30 30 - 300 300 - 1500 1500 - 100.000 614 824/f 27.5 1.63 2.19/f 0.073 #) (100) #) (180/f²) 0.2 f/1500 1.0 30 30 30 30 30 F = frequency in MHz # = Plane-wave equivalent power density 2. MAXIMUM PERMISSIBLE EXPOSURE Prediction Prediction of MPE limit at a given distance S = PG/4πR² S = Power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC014 F-TP22-03 (Rev. 06) Page 5 of 5 3. RESULTS [Uplink] - VHF (150.05 ~ 173.4 MHz) Maximum output Power at antenna input terminal 27.50 dBm Maximum output Power at antenna input terminal 562.34 mW Prediction distance 65.00 cm Prediction frequency 150.05 MHz Antenna Gain(typical) 9.15 dBi Antenna Gain(numeric) 8.22 - Power density at prediction frequency(S) 0.0871 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.1000 mW/cm 2 # Antenna Gain(dBi) = Antenna Gain(dBd) + 2.15 dB = 7 dBd + 2.15 dB = 9.15 dBi [Downlink] - VHF (150.05 ~ 173.4 MHz) Maximum output Power at antenna input terminal 33.50 dBm Maximum output Power at antenna input terminal 2 238.72 mW Prediction distance 65.00 cm Prediction frequency 150.05 MHz Antenna Gain(typical) 1.00 dBi Antenna Gain(numeric) 1.26 - Power density at prediction frequency(S) 0.0531 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.1000 mW/cm 2 # Antenna Gain(dBi) = Antenna Gain(dBd) + 2.15 dB = -1.15 dBd + 2.15 dB = 1.00 dBi
TEST REPORT FCC Test for PSR-V-9533-N Certification APPLICANT ADRF KOREA, Inc. REPORT NO. HCT-RF-2605-FC013 DATE OF ISSUE May 14, 2026 Tested by Kyung Soo Kang Technical Manager Jong Seok Lee F-TP22-03(Rev.06) 1 / 91 The report shall not be (partly) reproduced except in full without approval of the laboratory. HCT CO., LTD.2-6, 73, 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea Tel. +82 31 645 6300 Fax. +82 31 645 6401 The report shall not be (partly) reproduced except in full without approval of the laboratory. F-TP22-03 (Rev. 06) Page 2 of 91 HCT CO.,LTD. 2-6, 73, 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea Tel. +82 31 645 6300 Fax. +82 31 645 6401 TEST REPORT REPORT NO. HCT-RF-2605-FC013 DATE OF ISSUE May 14, 2026 A pplicantADRF KOREA, Inc. 196-16 IYEO-RO BAEKSA-MYEON ICHEON-SI, GYEONGGI-DO, 17316, KOREA Product Name Model Name BDA PSR-V-9533-N FCC IDN52-PSR-V-9533-N Date of TestFebruary 25, 2026 ~ May 14, 2026 Location of TestӍ Permanent Testing Lab ӎ On Site Testing (Address: 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi- do, Republic of Korea) Test Standard UsedCFR 47 Part 2, Part 90 Test ResultsPASS The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC013 F-TP22-03 (Rev. 06) Page 3 of 91 REVISION HISTORY The revision history for this test report is shown in table. Revision No. Date of Issue Description 0 May 14, 2026 Initial Release Notice Content Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules under normal use and maintenance. The results shown in this test report only apply to the sample(s), as received, provided by the applicant, unless otherwise stated. The test results have only been applied with the test methods required by the standard(s). The laboratory is not accredited for the test results marked *. Information provided by the applicant is marked **. Test results provided by external providers are marked ***. When confirmation of authenticity of this test report is required, please contact www.hct.co.kr The test results in this test report are not associated with the ((KS Q) ISO/IEC 17025) accreditation by KOLAS (Korea Laboratory Accreditation Scheme) / A2LA (American Association for Laboratory Accreditation) that are under the ILAC (International Laboratory Accreditation Cooperation) Mutual Recognition Agreement (MRA). The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC013 F-TP22-03 (Rev. 06) Page 4 of 91 CONTENTS 1. GENERAL INFORMATION 5 1.1. APPLICANT INFORMATION 5 1.2. PRODUCT INFORMATION 5 1.3. TEST INFORMATION 5 2. FACILITIES AND ACCREDITATIONS 6 2.1. FACILITIES 6 2.2. EQUIPMENT 6 3. TEST SPECIFICATIONS 7 3.1. STANDARDS 7 3.2. ADDITIONAL DESCRIPTIONS ABOUT TEST 8 3.3. MEASUREMENTUNCERTAINTY 10 3.4. STANDARDS ENVIRONMENTAL TEST CONDITIONS 10 3.5. TEST DIAGRAMS 11 4. TEST EQUIPMENTS 13 5. TEST RESULT 14 5.1. AGC THRESHOLD 14 5.2. OUT-OF-BAND REJECTION 20 5.3. OCCUPIED BANDWIDTH 22 5.4. INPUT-VERSUS-OUTPUT SIGNAL COMPARISON 44 5.5. INPUT/OUTPUT POWER AND AMPLIFIER/BOOSTER GAIN 66 5.6. NOISE FIGURE 73 5.7. OUT-OF-BAND/OUT-OF-BLOCK EMISSIONS AND SPURIOUS EMISSIONS 76 5.8. RADIATED SPURIOUS EMISSIONS 83 5.9. FREQUENCY STABILITY 86 6. Annex A_EUT AND TEST SETUP PHOTO 91 The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC013 F-TP22-03 (Rev. 06) Page 5 of 91 1. GENERAL INFORMATION 1.1. APPLICANT INFORMATION Company Name ADRF KOREA, Inc. Company Address 196-16 IYEO-RO BAEKSA-MYEON ICHEON-SI, GYEONGGI-DO, 17316, KOREA 1.2. PRODUCT INFORMATION EUT Type BDA EUT Serial Number PSRV9533NXXXXXX Power Supply AC 110~220 Vac Frequency Range Band Name Uplink / Downlink (MHz) VHF 150.05 ~ 173.4 Tx Output Power Band Name Uplink Downlink VHF 27 dBm 33 dBm Antenna Gain Band Name Uplink Downlink VHF 7 dBd -1.15 dBd 1.3. TEST INFORMATION FCC Rule Parts CFR 47 Part 2, Part 90 Measurement Standards KDB 935210 D05 v01r04, KDB 971168 D01 v03r01, ANSI C63.26-2015 Test Location 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC013 F-TP22-03 (Rev. 06) Page 6 of 91 2. FACILITIES AND ACCREDITATIONS 2.1. FACILITIES The SAC(Semi-Anechoic Chamber) and conducted measurement facility used to collect the radiated data are located at the 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea. The site is constructed in conformance with the requirements of ANSI C63.4. (Version :2014) and CISPR Publication 22. Detailed description of test facility was submitted to the Commission and accepted dated February 26, 2026(Registration Number: KR0032). 2.2. EQUIPMENT Radiated emissions are measured with one or more of the following types of linearly polarized antennas: tuned dipole, bi-conical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum analyzers with pre-selectors and quasi-peak detectors are used to perform radiated measurements. Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for making measurements. All receiving equipment conforms to CISPR Publication 16-1, ˑRadio Interference Measuring Apparatus and Measurement Methods.˒ The report shall not be (partly) reproduced except in full without approval of the laboratory. Report…
Text truncated - open the document above for the full version.
The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC013 F-TP22-03 (Rev. 06) Page 75 of 91 Plot data of Noise Figure Noise Figure / VHF (150.05 ~ 173.4) / Uplink Noise Figure / VHF (150.05 ~ 173.4) / Downlink The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC013 F-TP22-03 (Rev. 06) Page 76 of 91 5.7. OUT-OF-BAND/OUT-OF-BLOCK EMISSIONS AND SPURIOUS EMISSIONS §2.1051 Measurements required: Spurious emissions at antenna terminals. The radio frequency voltage or powers generated within the equipment and appearing on a spurious frequency shall be checked at the equipment output terminals when properly loaded with a suitable artificial antenna. Curves or equivalent data shall show the magnitude of each harmonic and other spurious emission that can be detected when the equipment is operated under the conditions specified in §2.1049 as appropriate. The magnitude of spurious emissions which are attenuated more than 20 dB below the permissible value need not be specified. §90.219 Use of signal boosters. (e) Device Specifications. In addition to the general rules for equipment certification in §90.203(a)(2) and part 2, subpart J of this chapter, a signal booster must also meet the rules in this paragraph. (3) Spurious emissions from a signal booster must not exceed −13 dBm within any 100 kHz measurement bandwidth. Test Procedures: Measurements were in accordance with the test methods section 4.7 of KDB 935210 D05 v01r04. Spurious emissions shall be measured using a single test signal sequentially tuned to frequencies within each authorized frequency band of operation. Intermodulation products shall be measured using two CW signals with all available channel spacing with the center between these channels being equal to the center frequency f 0 as determined from Out-of-band rejection test. 4.7.2 Out-of-band/out-of-block emissions conducted measurements a) Connect a signal generator to the input of the EUT. b) If the signal generator is not capable of producing two independent modulated carriers simultaneously, then two discrete signal generators can be connected, with an appropriate combining network to support the two- signal test. c) Configure the two signal generators to produce CW on frequencies spaced consistent with f 0 , with amplitude levels set to just below the AGC threshold. d) Connect a spectrum analyzer to the EUT output. e) Set the span to 100 kHz. f) Set RBW = 300 Hz with VBW ͖ 3 × RBW. g) Set the detector to power averaging (rms). h) Place a marker on highest intermodulation product amplitude. i) Capture the plot for inclusion in the test report. j) Repeat steps c) to h) with the composite input power level set to 3 dB above the AGC threshold. k) Repeat steps b) to i) for all operational bands. The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC013 F-TP22-03 (Rev. 06) Page 77 of 91 4.7.3 EUT spurious emissions conducted measurements a) Connect a signal generator to the input of the EUT. b) Configure the signal generator to produce a CW signal. c) Set the frequency of the CW signal to the center channel of the EUT passband. d) Set the output power level so that the resultant signal is just below the AGC threshold. e) Connect a spectrum analyzer to the output of the EUT, using appropriate attenuation as necessary. f) Set the RBW = 100 kHz. (i.e., for 30 MHz to 1 GHz PLMRS and/or PSRS booster devices) g) Set the VBW = 3 × RBW. h) Set the Sweep time = auto-couple. i) Set the detector to PEAK. j) Set the spectrum analyzer start frequency to 30 MHz (or the lowest radio frequency signal generated in the EUT, without going below 9 kHz if the EUT has additional internal clock frequencies), and the stop frequency to 10 times the highest allowable frequency of the EUT passband. k) Select MAX HOLD, and use the marker peak function to find the highest emission(s) outside the passband. (This could be either at a frequency lesser or greater than the passband frequencies.) l) Capture a plot for inclusion in the test report. m) Repeat steps c) to l) for each authorized frequency band/block of operation. The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC013 F-TP22-03 (Rev. 06) Page 78 of 91 Test Results: Plot data of Out-of-band/out-of-block emissions Out-of-band (two adjacent test signals) / VHF (150.05 ~ 173.4) / Uplink / 12.5kHz +3 dB above Out-of-band (two adjacent test signals) / VHF (150.05 ~ 173.4) / Uplink / 12.5kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC013 F-TP22-03 (Rev. 06) Page 79 of 91 Out-of-band (two adjacent test signals) / VHF (150.05 ~ 173.4) / Uplink / 25kHz +3 dB above Out-of-band (two adjacent test signals) / VHF (150.05 ~ 173.4) / Uplink / 25kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC013 F-TP22-03 (Rev. 06) Page 80 of 91 Out-of-band (two adjacent test signals) / VHF (150.05 ~ 173.4) / Downlink / 12.5kHz +3 dB above Out-of-band (two adjacent test signals) / VHF (150.05 ~ 173.4) / Downlink / 12.5kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC013 F-TP22-03 (Rev. 06) Page 81 of 91 Out-of-band (two adjacent test signals) / VHF (150.05 ~ 173.4) / Downlink / 25kHz +3 dB above Out-of-band (two adjacent test signals) / VHF (150.05 ~ 173.4) / Downlink / 25kHz The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2605-FC013 F-TP22-03 (Rev. 06) Page 82 of 91 Plot data of Spurious Emissions Spurious / VHF (150.05 ~ 173.4) / Uplink Spurious / VHF (150.05 ~ 173.4) / Downlink Note: Only the worst case plot for simultaneous spurious…
Text truncated - open the document above for the full version.
3116 W Vanowen St. · Burbank, 91505 · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 9 | 150.05 MHz - 173.4 MHz | 493.00 mW | F1W | Amp |
| 2 | 9 | 150.05 MHz - 173.4 MHz | 2.109 W | F1W | Amp |
Equipment Class
B9B - Part 90 Class B Industrial Booster (non-SMR)Equipment Class
B9A - Part 90 Class A Industrial Booster (non-SMR)Equipment Class
B9B - Part 90 Class B Industrial Booster (non-SMR)Equipment Class
B9A - Part 90 Class A Industrial Booster (non-SMR)Public Safety Repeater
Equipment Class
B9A - Part 90 Class A Industrial Booster (non-SMR)