FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Communication Network Interface Inc./
  3. N79CNI-900KM

N79CNI-900KMTwo Way Personal Communicator

Communication Network Interface Inc.
Two Way Personal Communicator - FCC ID N79CNI-900KM - Communication Network Interface Inc.
Click to zoom

Application Details

Equipment Class
PCT - PCS Licensed Transmitter worn on body
Date of Grant
Mar 31, 2005
Application Purpose
Original Equipment
Date of Application
Mar 31, 2005
Equipment Note
Two Way Personal Communicator
Frequency Range
901.00000000 - 902.00000000
Company
Communication Network Interface Inc.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Getting Started Guide for CNI-900KM Getting Started Guide for CNI-900KM Document title: Getting Started Guide for CNI-900KM Edition Date Version Remarks 1 September 17, 2002 Version 0.1 Preliminary Release Copyright 2002, Communication Network Interface, Inc. All rights reserved. Communication Network Interface and CNI are registered trademarks of Communication Network Interface, Inc. MOBITALK is a registered trademark of Communication Network Interface, Inc. Mobitex is a trademark of the Swedish Telecommunications Administrations. MSN, ICQ and Yahoo are registered trademarks of respective owners of the trademarks. This document is for supply to licensed customers or parties only. The contents are confidential, and any disclosure to persons not directly authorized by CNI is strictly prohibited. No part of this publication, or any software included with it, may be reproduced, distributed, stored in a retrieval system, or transmitted in any form or by any means without the prior written permission of the copyright holder. This document may contain technical inaccuracies or typographical errors. CNI and its subsidiaries waive responsibility for any labor, material, or cost incurred by any person or party as a result of using this document. CNI and its subsidiaries or other affiliates shall not be liable for any damages including, but not limited to, consequential, indirect or incidental, special damages, or loss of profits or loss of data. Communication Network Interface, Inc. 13F Dae-A Bldg. 165-5 Dong-Gyo Dong, Ma-Po Ku, Seoul 121-200 KOREA Phone : +82-2-330-5611 Fax : +82-2-330-5773 Getting Started Guide for CNI-900KM Table Of Contents GETTING TO KNOW YOUR MOBITALK......................................................................................... 1 FULLY CHARGE BEFORE USE ...................................................................................................... 2 STARTING YOUR MOBTALK ..........................................................................................................2 T URNING YOUR MOBITALK ON/OFF............................................................................................................................ 2 MOBITALK HOME SCREEN........................................................................................................................................... 3 N AVIGATING USING TRACKWHEEL.................................................................................................................................. 4 E NTERING E-MAIL ADDRESS........................................................................................................................................... 4 E NTERING SYMBOLIC CHARACTERS................................................................................................................................4 K EYS AND KEY COMBINATIONS....................................................................................................................................... 5 CUSTOMIZING YOUR MOBITALK .................................................................................................. 6 H OW TO SET VALUES........................................................................................................................................................ 6 MOBITALK PROGRAMS ................................................................................................................. 6 M ESSENGER.................................................................................................................................................................... 6 SMS ................................................................................................................................................................................ 7 C HAT............................................................................................................................................................................... 7 M AIL............................................................................................................................................................................... 8 A DDRESS BOOK............................................................................................................................................................... 8 C ALCULATOR................................................................................................................................................................... 9 DESKTOP SOFTWARE ................................................................................................................... 9 Getting Started Guide for CNI-900KM Getting to know Your MOBITALK Front Back LED LCD Trackwheel ESC Enter Del/Backspace CAP(sym)R-arrowSpaceL-arrow ALT Serial Port Reset Button Strap Hole Speaker Connect the Serial Port to the serial cable provided. (For information about connectin g the serial port, see “Fully Char ge Before Use,” page 2.) In case of difficulty Press the Reset Button with a sharp-end tool (such as a sharp pencil) to restart the system. Power Home Key Getting Started Guide for CNI-900KM Fully Charge Before Use Please follow the instructions below to fully charge your MOBITALK: „ Connect the serial cable both to the serial port of the MOBITALK and to the power adapter cable. „ It takes 3 hours to fully charge your MOBITALK. „ Red LED: Charging „ Green LED: Fully charged Your MOBITALK is now ready for use. The following sections will help you understand the functions of your MOBITALK. Starting your MOBTALK Turning Your MOBITALK ON/Off To turn your MOBITALK on, press and hold the Power button for 4 seconds. To turn it off, press and hold the Power button for 3 seconds. Power Save Mode Power Save Mode is set to one minute. To get out of the Power Save Mode, press the ESC or Power button once. To chan ge the Power Save Mode setting, go to General Settings in Functions. Serial Port Getting Started Guide for …

Text truncated - open the document above for the full version.

Attestation Statements

Communication Network Interface, Inc. 3F, JungSoft Bldg., 274-5 Seohyeon-Dong, Bundang-Gu, Seongnam-Si, Gyeonggi-Do, 463-824 Korea Date: March 2, 2005 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch, 7435 Oakland Mills Road Columbia, MD 21046, U.S.A. Subject: Authorization Letter FCC ID: N79CNI-900KM Company: Communication Network Interface, Inc. EUT Type: Two Way Personal Communicator FCC Part 24 Subpart D/ Part 90 To whom it may concern: We, the undersigned. hereby authorized HYUNDAI Calibration & Certification Technologies Co., Ltd. to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these manners. Any and all acts carried out by HYUNDAI Calibration & Certification Technologies Co., Ltd. on our behalf shall have the same effect as acts of our own. This authorization is valid until Dec. 31, 2005. Sincerely Yours, Mr. Jeonghun Yang – R&D Director Communication Network Interface, Inc. Communication Network Interface, Inc. 3F, JungSoft Bldg., 274-5 Seohyeon-Dong, Bundang-Gu, Seongnam-Si, Gyeonggi-Do, 463-824 Korea Date: March 2, 2005 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch, 7435 Oakland Mills Road Columbia, MD 21046, U.S.A. Subject: Request for Confidentiality FCC ID: N79CNI-900KM Company: Communication Network Interface, Inc. EUT Type: Two Way Personal Communicator FCC Part 24 Subpart D/ Part 90 Gentlemen: In accordance with 0.459 of CFR 47, Communication Network Interface, Inc. hereby requests confidentiality of the Block Diagrams attachment, Schematic Diagrams attachment, Operational Description attachment, and Part List/Tune-Up Procedure attachment for the above-referenced Certification application. These documents contain detailed system and equipment description and related information about the product which Communication Network Interface, Inc. considers to be proprietary, confidential, and a custom design and, otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, Communication Network Interface, Inc. feels this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Sincerely Yours, Mr. Jeonghun Yang – R&D Director Communication Network Interface, Inc. Communication Network Interface, Inc. 3F, JungSoft Bldg., 274-5 Seohyeon-Dong, Bundang-Gu, Seongnam-Si, Gyeonggi-Do, 463-824 Korea Date: March 2, 2005 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch, 7435 Oakland Mills Road Columbia, MD 21046, U.S.A. Subject: User's Manual RF Exposure Warning Statement FCC ID: N79CNI-900KM Company: Communication Network Interface, Inc. EUT Type: Two Way Personal Communicator FCC Part 24 Subpart D/ Part 90 Gentlemen: Communication Network Interface, Inc. hereby confirms that the attached RF exposure warning page will be readily visible to the user, and will be placed at a prominent location in the front section of the user's manual. Should you have any questions or comments concerning the above, please do not hesitate contact me. Sincerely Yours, Mr. Jeonghun Yang – R&D Director Communication Network Interface, Inc.

Cover Letter(s)

SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNKI-DO, 467-701, KOREA TEL: +82 31 639 8518 FAX: +82 31 639 8525 http://www.hct.co.kr March 17, 2005 Test Site: HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. FRN: 0005866421 SUBJECT: Communication Network Interface, Inc. FCC ID: N79CNI-900KM FCC Part 24 Subpart D/ Part 90 Gentlemen: Submitted herewith, on behalf of FCC Part 24 Subpart D and Part 90, is an application for Certification of the following Two Way Personal Communicator: Trade Name/Model(s): CNI / CNI-900KM EUT Type: Two Way Personal Communicator - Prototype Tx Frequency: 896 MHz — 902 MHz Rx Frequency: 929 MHz — 942 MHz Max. RF Output Power: 0.288 mW (24.59 dBm) Maximum SAR: 0.827 W/kg Body SAR Attached is the applicant’s Letter of measurement report test data and plots, FCC ID label and location, test setup photographs, internal and external photographs, block diagram, circuit diagrams & description, operational description, parts list and the user's manual. Should you have any questions or comments concerning the above, please contact the undersigned. Report prepared by: Ki-Soo Kim Manager of Product Compliance Team cc: Mr. Jeonghun Yang – Communication Network Interface, Inc. [email protected]

Cover Letter(s)

Butch dela Cruz Subject: FW: FCC Part 24D, 90 Application. (FCC ID: N79CNI-900KM): Communication Network Interface, Inc. From: 박근호 (HCT) [mailto:[email protected]] Sent: Sunday, March 27, 2005 3:48 AM To: Butch dela Cruz Cc: 정문진 과장(HCT); PCTEST - Randy Ortanez; PCTEST - Andrea Zaworski; PCTEST - Al Cirwithian; PCTEST - Accounting; 'KiSoo Kim (HCT)' Subject: Re: FCC Part 24D, 90 Application. (FCC ID: N79CNI-900KM): Communication Network Interface, Inc. Dear Sir, Thanks very much for your support. According to your requests on the below questions, we'd like to send the answers on each questions under each question as belows; If you have questions or comments on this application, please do not hesitate to conatct us. Thanks and Best Regards, Keun- Ho Park - HCT ----- Original Message ----- From: Butch dela Cruz To: [email protected] Cc: 'KiSoo Kim (HCT)' ; PCTEST - Accounting ; PCTEST - Al Cirwithian ; PCTEST - Andrea Zaworski ; PCTEST - Randy Ortanez Sent: Saturday, March 26, 2005 7:41 AM Subject: FCC Part 24D, 90 Application. (FCC ID: N79CNI-900KM): Communication Network Interface, Inc. Hi Mr. Park, Please see below our questions regarding the Communication Network Interface, Inc. TCB application. 1. The unit has a serial port. Is there a Doc test report? ===> Please find the attached test report. (filename: EMI_Part 15 Test-Report) 2. The conducted power is 32.6 dBm and the EIRP data is 24.6 dBm. Please explain the loss. ====> We changed the matching circuit of the Antenna feeding port to reduce the ERP Power. It doesn't effect to the operation of the product. User can use the CNI-900KM without any problems. 3. Please indicate the antenna location in the internal photos. ===> Please find the attached in the internal photos. (filename: Internal photo(page: 12, 13) If you have any questions please do not hesitate to contact us. Best Regards, Butch dela Cruz

External Photos

Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 EXTERNAL PHOTO HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr

ID Label/Location Info

Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 ID LABEL HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 (See below photo) LABELLING REQUIREMENTS PER §§ 2.925 The Label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr

Internal Photos

Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 INTERNAL PHOTO HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr

RF Exposure Info

© 2005 RF Exposure Evaluation - Maximum Permissible Exposure (MPE) 1. Introduction This document attempts to prove the safety of radiation generated by RF devices to the human body. The limit for Maximum Permissible Exposure (MPE), specified in FCC 1.1210, is listed below. The power generated by this product is measured by a power meter. Through use of the Friis transmission formula and the maximum gain of the antenna, the distance from the product at which compliance with the MPE limit is achieved may be calculated. Alternatively, near field measurements may be performed to demonstrate compliance at a specific measurement distance. Near field probe: Wandel & Goltermann EMR-20. 2. RF Exposure Limit According to FCC 1.1310: the criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified in 1.1307(b). LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (Minutes) (A) Limits For Occupational / Control Exposures 30-300 61.4 .163 1.0 6 300-1500 ... ... F/300 6 1500-100,000 ... ... 5 6 (B) Limits For General Population / Uncontrolled Exposure 30-300 27.5 .073 .2 30 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 3. Friis Formula Friis transmission formula: Pd = (P out *G) / (4pr 2 ) Where: Pd = power density in mW/cm 2 (MPE limit) P out = output power to antenna in mW G = gain of antenna in linear scale p = 3.1416 r = distance between observation point and center of the radiator in cm Ref.: David K. Cheng, Field and Wave Electromagnetics, Second Edition, Page 640, Eq. (11.133) © 2005 4. EUT Operating Condition Software provided by the client enabled the EUT to transmit and receive data at lowest, middle, and highest channels individually. 5. Climate Condition The temperature and relative humidity: 22°C and 78% RH 6. Measurement Results Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) F2 899 0.288 0.0573 1. Data taken with all transmitters operating simultaneously 7. Conclusion The device meets the mobile 20cm separation distance as specified in Section 2.1091 of the FCC Rules. An appropriate RF exposure compliance statement will be placed in the user’s manual.

Test Report

HYUNDAI CALIBRATION & CERTIFICATION TECH. CO., LTD. PRODUCT COMPLIANCE DIVISION SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr CERTIFICATE OF COMPLIANCE FCC Part 24 & 90 Certification Communication Network Interface, Inc. 3F, JungSoft Bldg., 274-5 Seohyeon-Dong, Bundang-Gu, Seongnam-Si, Gyeonggi-Do, 463-824 Korea Date of Issue: March 15, 2005 Test Report No.: HCT-SAR05-0313 Test Site: HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. FRN: 0005866421 N79CNI-900KM Communication Network Interface, Inc. FCC ID : APPLICANT : EUT Type: Two Way Personal Communicator - Prototype Tx Frequency: 896 MHz — 902 MHz Rx Frequency: 929 MHz — 942 MHz Max. RF Output Power: 0.288 mW (24.59 dBm) Trade Name: CNI Model No.: CNI-900KM Equipment Class: PCS Licensed Transmitter Application Type: Certification FCC Rule Part(s): FCC Part 24 Subpart D/ Part 90 Maximum SAR: 0.827 W/kg Body SAR This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in §2.947. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. The results in this report apply only to the sample tested. Hyundai C-Tech Co., Ltd. certifies that no party to this application has been denied FCC benefits pursuant to section 5301 of the Anti- Drug Abuse Act of 1998, 21 U.S. C. 853(a) Report prepared by : Ki-Soo Kim Manager of Product Compliance Team This report only responds to the tested sample and may not be reproduced, except in full, without written approval of the HCT Co., Ltd. Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr 2 of 26 TABLE OF CONTENTS 1 - GENERAL INFORMATION.......................................................................................................................................3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................3 1.2 OBJECTIVE .............................................................................................................................................................3 1.3 RELATED SUBMITTAL(S)/GRANT(S).....................................................................................................................3 1.4 TEST METHODOLOGY ...........................................................................................................................................3 1.5 TEST FACILITY........................................................................................................................................................4 2 - SYSTEM TEST CONFIGURATION..........................................................................................................................4 2.1 JUSTIFICATION ......................................................................................................................................................4 2.2 BLOCK DIAGRAM....................................................................................................................................................4 2.3 EQUIPMENT MODIFICATIONS ..............................................................................................................................4 2.4 TEST SETUP BLOCK DIAGRAM.............................................................................................................................4 3 - SUMMARY OF TEST RESULTS...............................................................................................................................5 3.1 FREQUENCY AVAILABLE.......................................................................................................................................5 3.2 SUMMARY OF TEST RESULTS .............................................................................................................................5 3.3 LABEL REQUIREMENT...........................................................................................................................................5 4 - RF POWER OUTPUT................................................................................................................................................6 4.1 APPLICABLE STANDARD .......................................................................................................................................6 4.2 TEST PROCEDURE ................................................................................................................................................6 4.3 TEST RESULTS .......................................................................................................................................................6 5 - MODULATION CHARACTERISTIC..........................................................................................................................7 5.1 APPLICABLE STANDARD .......................................................................................................................................7 5.2 TEST PROCEDURE..................................................................................................................................................7 5.3 TEST RESULTS ...................................................................................................................................................8-10 6 - OCCUPIED BANDWIDTH.........................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 TEST SETUP PHOTO HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr Report No.: HCT-SAR05-0313 FCC ID: N79CNI-900KM Date: March 15, 2005 HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hct.co.kr

Contact Information

Applicant

CALI Kim(Senior Sales & Marketing Manager)
[email protected]82-2-330-5623Fax: 82-2-330-5770

Technical Contact

PCTEST Engineering Lab., Inc.Randy Ortanez
[email protected]410-290-6652

6660-B Dobbin Road · Columbia, Maryland · United States

Test Firm

HCT Co., LTDSang Lee
[email protected]82-31-645-6420Fax: 82-31-645-6401

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224D901 MHz - 902 MHz267.00 mW8K25F1D1 ppm
Confidentiality
Long Term
Grant Notes
Output is ERP. This device is considered a mobile device with respect to RF exposure. For mobile exposure conditions, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.

Other Applications from Communication Network Interface Inc.

Radio Pocket Modem - FCC ID N79CNI-903M-1 - Communication Network Interface Inc.
N79CNI-903M-1

Radio Pocket Modem

Dec 12, 2001

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Radio Packet Modem - FCC ID N79CNI-803D - Communication Network Interface Inc.
N79CNI-803D

Radio Packet Modem

Apr 05, 2001

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
TWM3 Digital Data Communication Equipment - FCC ID N79CNI-930M - Communication Network Interface Inc.
N79CNI-930M

TWM3 Digital Data Communication Equipment

Oct 30, 2000

Equipment Class

TNT - Licensed Non-Broadcast Transmitter Worn on Body
Radio Packet Modem - FCC ID N79CNI-903M - Communication Network Interface Inc.
N79CNI-903M

Radio Packet Modem

Jul 13, 2000

Equipment Class

TNT - Licensed Non-Broadcast Transmitter Worn on Body
TNB - Licensed Non-Broadcast Station Transmitter - FCC ID N79CNI-800D - Communication Network Interface Inc.
N79CNI-800D

TNB - Licensed Non-Broadcast Station Transmitter

Feb 02, 2000

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter