Date: April 11, 2023 Subject: Vehicle Manufacturer Regulatory Text Requirement Statement We declare that all the information will be provided to the Vehicle Manufacturer so that the statements below is passed on to the end user of FPK8I5DTR2 to ensure compliance with FCC and ISED Canada certification requirements. Likewise, we declare that we will also provide the Vehicle Manufacturer with the certification statements and marks required in every country where the FPK8I5DTR2 is type approved. In addition to above, Visteon also declare that will pass onto car manufacturer the most relevant technical features of the device as well as brand name and model name: Model name: FPK8I5DTR2 Brand name: Visteon Operation frequency: 125 kHZ No. of Channels: 1 Modulation: ASK Antenna specification: Coil antenna - For FCC Compliance: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate. This device complies with the portable exposure requirements of FCC Part 2.1093. - For ISED Canada Compliance: English RSS-Gen Information for the Certification of Radio Apparatus. This device complies with ISED license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. The radio transmitter (IC: 3043A-FPK8I5DTR2) have been approved by ISED Canada to operate with the antenna type given above, with the maximum permissible gain indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. This device complies with the safety requirements for RF exposure in accordance with RSS-102 Issue 5 for portable use conditions with 0mm separation. Français: Cet appareil est conforme au(x) standard(s) RSS exempts de licence d’Industrie Canada. Son exploitation est soumise aux deux conditions suivantes: (1) cet appareil ne doit pas occasionner d’interférence et (2) cet appareil doit supporter toutes les interférences, y compris celles qui pourraient rovoquer un mauvais fonctionnement de cet appareil. Cet émetteur radio (IC: 3043A-FPK8I5DTR2 ) a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne spécifié ci-dessus avec le gain d’antenne maximal autorisé indiqué. Les types d'antennes non inclus dans cette liste ayant un gain supér gain maximal indiqué pour ce type sont strictement interdits pour une utilisation avec cet appareil. Cet appareil est conforme aux exigences de sécurité relatives à l’exposition aux radio fréq conformément à la norme RSS-102 Issue 5 pour les conditions d’utilisation portable av separation de 0mm. Brazil Para maiores informações, consulte o site da ANATEL www.anatel.gov.br “Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente autorizados” (Translation: This equipment is not entitled to protection against harmful interference and may not cause interference in duly authorized systems) Taiwan 低功率射頻器材技術規範3.8.2警語 取得審驗證明之低功率射頻器材,非經核准,公司、商號或使用者均不得擅自變更頻率 、加大功率或變更原設計之特性及功能。低功率射頻器材之使用不得影響飛航安全及干 擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。前 述合法通信,指依電信管理法規定作業之無線電通信。低功率射頻器材須忍受合法通信 或工業、科學及醫療用電波輻射性電機設備之干擾。 Moldova Visteon declare that vehicle manufacturer will be informed to provide a user manual in Romanian language when they place the device in Moldova market. Ukraine Visteon declare that vehicle manufacturer will be informed to provide a user manual in Ukrainian language when they place the device in Ukraine market. Customs Union Visteon declare that vehicle manufacturer will be informed to provide a user manual in Russian language when they place the device in Custom union market. Signed by: Victor Lindauer, Project Technical Development Lead
Heidi Sepanik Corporate Secretary Visteon’ | Visteon Corporation One Village Center Drive Van Buren Township, MI, 48111 U.S.A \ (734) 710-4672 Q (734) 736-8560 © Fex number a [email protected] ween visteon.cam CFR 47 §2.911 (d)(5) Attestation Date: February 17, 2023 FCC ID: NT8-FPK8I5DTR2 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Visteon Corporation (“the applicant”) certifies that the equipment for which authorization 1. is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. 2. Visteon Corporation (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment and is not an affiliate or subsidiary of an entity identified on the Covered List. Sincerely yours, ord Ov Sep Gv Name: Heidi Sepanik Title: Corporate Secretary Telephone: (734) 70-4672 e-mail: [email protected]
Visteon Corporation One Village Center Drive Van Buren Township, MI, 48111 www.visteon.com Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(7) Agent Designation Attestation Date: February 20, 2023 FCC ID: NT8-FPK8I5DTR2 To whom it may concern: Visteon Corporation (“the applicant”) as required by section §2.911(d)(7), will also serve as the agent for service of process for the above referenced FCC ID. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility under CFR 47 §2.929(c) to inform the FCC whenever the agent information changes. Contact Person: Terry SanSouci Company name: Visteon Corporation FCC FRN: 0007336639 Company US Address: One Village Center Drive, Van Buren Township, MI, 48111 United States Email: [email protected] Sincerely yours, Contact Person: Terry SanSouci Company Name: Visteon Corporation Company US Address: One Village Center Drive, Van Buren Township, MI, 48111 United States
UL International (UK) Ltd Form-ULID-017798, issue 1 Visteon Corporation One Village Center Drive Van Buren Township, MI, 48111 www.visteon.com Date: February 17, 2023 Telecommunication Certification Body UL International (UK) Ltd Units 1-3, Horizon Wade Road Kingsland Business Park Basingstoke Hampshire RG24 8AH United Kingdom Subject: Authorisation Letter To whom it may concern This is to certify that Visteon Corporation hereby authorises UL International (UK) Ltd. to act as the TCB for the application of the Instrument Cluster with immobilizer circuit model name FPK8I5DTR2, FCC ID: NT8-FPK8I5DTR2 to the FCC. We certify that we are not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. Yours faithfully, _________________________ By: Terry SanSouci Title: Principal Engineer II Hardware Test Company: Visteon Corporation Telephone: (734) 710-7137 e-mail: [email protected]
UL International (UK) Ltd Form-ULID-017798, issue 1 Visteon Corporation One Village Center Drive Van Buren Township, MI, 48111 www.visteon.com Date: April 12, 2023 Telecommunication Certification Body UL International (UK) Ltd Units 1-3, Horizon Wade Road Kingsland Business Park Basingstoke Hampshire RG24 8AH United Kingdom Subject: Permanent Confidentiality Request Certification Application FCC ID: NT8-FPK8I5DTR2 To whom it may concern Pursuant to Sections 0.457(d) and 0.459 of CFR 47, Visteon Corporation request that the following information, provided to support the FCC application for Instrument Cluster with immobilizer circuit model name FPK8I5DTR2, FCC ID: NT8-FPK8I5DTR2 be held permanently confidential: Schematics Block Diagrams Parts List Operational Description The above material contains trade secrets not customarily released to public that are judged to have the potential to cause detriment to the applicant and provide unjustified benefits to its competitors. This information should not be available for public disclosure for an indefinite period of time. Yours faithfully, ------------------------------- By: Terry SanSouci Title: Environmental Validation Engineer Company: Visteon Corporation Telephone: (734) 710-7137 e-mail: [email protected]
UL International (UK) Ltd Form-ULID-017798, issue 1 Visteon Corporation One Village Center Drive Van Buren Township, MI, 48111 www.visteon.com Date: February 17, 2023 Telecommunication Certification Body UL International (UK) Ltd Units 1-3, Horizon Wade Road Kingsland Business Park Basingstoke Hampshire RG24 8AH United Kingdom Subject: Short Term Confidentiality Request FCC ID: NT8-FPK8I5DTR2 To whom it may concern In accordance with §0.457 and §0.459 of CFR 47, Visteon Corporation requests the short-term confidentiality of the items 180 days from grant date market for our device, FCC ID: NT8-FPK8I5DTR2 External Photos Internal Photos Test Set Up Photos User Guide These items contain proprietary information related to the design of the product which has not yet been released to the market. The public disclosure of this information prior to public launch may be harmful to Visteon Corporation and provide unjust benefits to its competitors. A period 180 days from grant date market for our device is requested to protect this information before formal market launch. If the launch date is re-scheduled to be earlier than this period, Visteon Corporation will inform again to cancel this restriction. Please contact the undersigned if there are any further questions or additional information needed in this matter. Yours faithfully, ------------------------------- By: Terry SanSouci Title: Principal Engineer II Hardware Test Company: Visteon Corporation Telephone: (734) 710-7137 e-mail: [email protected]
External photos of instrument cluster with an immobilizer circuit Model FPK8I5DTR2 FCC ID: NT8-FPK8I5DTR2 IC: 3043A-FPK8I5DTR2, HVIN: PWB26554 Front side Back side
External photos of instrument cluster with an immobilizer circuit Model FPK8I5DTR2 FCC ID: NT8-FPK8I5DTR2 IC: 3043A-FPK8I5DTR2, HVIN: PWB26580 Front side Back side
Mechanical Lock surrounded by induction loop (coil) antenna
Internal photos of instrument cluster with an immobilizer circuit Model FPK8I5DTR2 FCC ID: NT8-FPK8I5DTR2 IC: 3043A-FPK8I5DTR2, HVIN: PWB26554 Transponder
Internal photos of instrument cluster with an immobilizer circuit Model FPK8I5DTR2 FCC ID: NT8-FPK8I5DTR2 IC: 3043A-FPK8I5DTR2, HVIN: PWB26580 Transponder
UL International Ltd (UK) Ltd Unit 1-3 Horizon, Wade Road, Kingsland Business Park, Basingstoke, RG24 8AH, UK T: +44 (0)1256 312000 / F: +44 (0)1256 312001 / W: www.ul.com Registered in England and Wales Company Number: 2117901 RF Exposure Analysis – SAR Test Exemption – Visteon Corporation FPK8I5DTR2 FCC ID: NT8-FPK8I5DTR2 The FPK8I5DTR2 equipment operates using a 125 kHz transmitter. The following FCC Rule Parts and Procedures are applicable: KDB447498 D04 V01 – Interim General RF Exposure Guidance Part 1.1307(b)(3)(i)(A) - Blanket RF exposure exemption (i) Part 1.1307(b)(3)(i)(C) - SAR test exemption (ii) Part 1.1307(b)(3)(i)(B) - SAR test exemption (iii) For the FPK8I5DTR2 Operating Frequency: 125 kHz Tx Power max (declared inc. tune up tolerance): 84.0dBμV/m @3m = -11.2 dBm EIRP = -13.35 dBm ERP Measured radiated power – Ref KDB447498 D04 Section 3.1.2 – When an antenna port is not available on the device to support conducted power measurement, e.g.: with built-in integral antennas, the available maximum output power or ERP, whichever is larger, and tolerance allowed for production units shall be used to determine RF exposure test exemption and compliance. Evaluation From Part 1.1307, RF exposure exemption applies if the maximum transmitted power is less than the maximum of the following three criteria: i) Less than 1 mw Blanket exemption. P TH = 0.001 W – §1.1307(b)(3)(i)(A) ii) determination of exemption under the MPE-based §1.1307(b)(3)(i)(C), if i) not met iii) determination of exemption under the SAR-based §1.1307(b)(3)(i)(B) if both i) and ii) are not met; Conclusion The FPK8I5DTR2 source-based, time-averaged power is -13.35 dBm (0.046 mW). i.e.: less than 1 mW (0 dBm), so complies with the RF exposure blanket exemption in accordance with §1.1307(b)(3)(i)(A).
UL INTERNATIONAL GERMANY GMBH Hedelfinger Str. 61 70327 Stuttgart, Germany [email protected] TEST REPORT Test Report No. : UL-RPT-RP-14374669-616-FCC Applicant * : Visteon Corporation Model No. * : FPK8I5DTR2 FCC ID * : NT8-FPK8I5DTR2 Technology * : RFID – 125 kHz Test Standard(s) : FCC Parts 15.205,15.209(a),15.215 For details of applied tests refer to test result summary 1. This test report shall not be reproduced in full or partial, without the written approval of UL International Germany GmbH. 2. The results in this report apply only to the sample tested. 3. The test results in this report are traceable to the national or international standards. 4. Test Report Version 1.2 supersede Version 1.1 with immediate effect Test Report No. UL-RPT-RP-14374669-616-FCC Version 1.2, Issue Date 20 April 2023 replaces Test Report No. UL-RPT-RP-14374669-616-FCC Version 1.1, Issue Date 28 February 2023, which is no longer valid. 5. 6. Result of the tested sample: PASS All information marked with a (*) were provided by customer / applicant or authorized representative ______________________________ ___________________________ Prepared by: Muhammad Faiq, Khan Approved by: Rachid, Acharkaoui Title: Project Engineer Title: Operations Manager Date: 20 April 2023 Date: 20 April 2023 This laboratory is accredited by DAkkS. The tests reported herein have been performed in accordance with its’ terms of accreditation. UL INTERNATIONAL GERMANY GMBH TEST REPORT NO: UL-RPT-RP-14374669-616-FCC TEST REPORT VERSION 1.2 ISSUE DATE: 20 APRIL 2023 Page 2 of 32 FCC 15.215 - Template Ver. 1.5 This page has been left intentionally blank. UL INTERNATIONAL GERMANY GMBH TEST REPORT NO: UL-RPT-RP-14374669-616-FCC TEST REPORT VERSION 1.2 ISSUE DATE: 20 APRIL 2023 Page 3 of 32 FCC 15.215 - Template Ver. 1.5 Table of Contents 1. Customer Information * ............................................................................................................. 4 1.1. Applicant Information 4 1.2. Manufacturer Information 4 2. Summary of Testing ................................................................................................................... 5 2.1. General Information 5 Applied Standards 5 Location 5 Date information 5 2.2. Summary of Test Results 6 2.3. Methods and Procedures 6 2.4. Deviations from the Test Specification 6 3. Equipment Under Test (EUT) .................................................................................................... 7 3.1. Identification of Equipment Under Test (EUT) * 7 3.2. Description of EUT * 7 3.3. Modifications Incorporated in the EUT 7 3.4. Additional Information Related to Testing * 8 3.5. Support Equipment 8 A. Support Equipment (In-house) 8 B. Support Equipment (Manufacturer supplied) 8 4. Operation and Monitoring of the EUT during Testing ............................................................. 9 4.1. Operating Modes 9 4.2. Configuration and Peripherals 9 5. Measurements, Examinations and Derived Results ...............................................................10 5.1. General Comments 10 5.2. Test Results 11 5.2.1. Transmitter 20 dB Bandwidth 11 5.2.2. Transmitter Fundamental Field Strength 15 5.2.3. Transmitter Radiated Spurious Emissions 19 6. Measurement Uncertainty ........................................................................................................26 7. Used equipment ........................................................................................................................27 8. Open-Area-Test Site comparison .............................................................................................28 9. Report Revision History ...........................................................................................................32 UL INTERNATIONAL GERMANY GMBH TEST REPORT NO: UL-RPT-RP-14374669-616-FCC TEST REPORT VERSION 1.2 ISSUE DATE: 20 APRIL 2023 Page 4 of 32 FCC 15.215 - Template Ver. 1.5 1. Customer Information * 1.1. Applicant Information Company Name: Visteon Corporation Company Address: One Village Center Drive Van Buren Township, MI, 48111 USA Contact Person: Heidi Sepanik Contact E-Mail Address: [email protected] Contact Phone No.: +1 734 710 4672 1.2.Manufacturer Information Company Name: Visteon Corporation Company Address: One Village Center Drive Van Buren Township, MI, 48111 USA Contact Person: Heidi Sepanik Contact E-Mail Address: [email protected] Contact Phone No.: +1 734 710 4672 UL INTERNATIONAL GERMANY GMBH TEST REPORT NO: UL-RPT-RP-14374669-616-FCC TEST REPORT VERSION 1.2 ISSUE DATE: 20 APRIL 2023 Page 5 of 32 FCC 15.215 - Template Ver. 1.5 2. Summary of Testing 2.1. General Information Applied Standards Specification Reference: 47CFR15.205 and 47CFR15.209 Specification Title: Code of Federal Regulations Volume 47 (Telecommunications): Part 15 Subpart C (Intentional Radiators) - Sections 15.205 and 15.209 Specification Reference: 47CFR15.215 Specification Title: Code of Federal Regulations Volume 47 (Telecommunications): Part 15 Subpart C (Intentional Radiators) - Sections 15.215 Test Firm Registration: 399704 Location Location of Testing: UL International Germany GmbH Hedelfinger Str. 61 70327 Stuttgart Germany Date information Order Date: 15 January 2022 EUT arrived: 05 October 2022 & 17 January 2023 Test Dates: 11 October 2022 to 20 January 2023 EUT returned: -/- UL INTERNATIONAL GERMANY GMBH TEST REPORT NO: UL-RPT-RP-14374669-616-FCC TEST REPORT VERSION 1.2 ISSUE DATE: 20 APRIL 2023 Page 6 of 32 FCC 15.215 - Template Ver. 1.5 2.2. Summary of Test Results Clause Measurement Complied Did not comply Not performed Not applicable Part 15.207 Transmitter AC Conducted Emissions (1) ☐ ☐ ☐ ☒ Part 15.215(c) Transmitter 20 dB Bandwidth ☒ ☐ ☐ ☐ Part 15.209(a) Transmitter Fundamental Field Strength ☒ ☐ ☐ ☐ Part 15.209(a)(c) Transmitter Radiated Emissions ☒ ☐ ☐ ☐ Decision rule: If the decision rule is not included in the applied customer specification or testing standard, the binary statement…
Text truncated - open the document above for the full version.
UL International (UK) LTD Unit 1-3 Horizon, Wade Road, Kingsland Business Park, Registered in England and Wales Basingstoke, Hampshire, RG24 8AH, UK. Company Registration No.: 2117901 Tel: +44 (0) 1256 312000 / Web: www.ul.com Justification for no antenna gain information As the loop coil antenna connected to the 125 kHz transmitter is integral and the output is measured as a fieldstrength at a given distance, antenna gain information is, therefore, not required. Only radiated measurements are used to show compliance with the FCC limits for fundamental and spurious emissions.
Visteon Corporation FCC ID: NT8-FPK8I5DTR2 UL-RPT-RP-14374669-616 IC: 3043A- FPK8I5DTR2 UL International Germany GmbH Muhammad Faiq Khan 20.04.2023 Hedelfinger Str. 61/ 70327 Stuttgart/ Germany Template version: 2.0 Page 1 of 2 Test Setup Photographs for Model No. / PMN: FPK8I5DTR2 1. Radiated Emissions Photo 1: Radiated Test Setup from 9 kHz to 30 MHz Photo 2: Radiated Test Setup from 9 kHz to 30 MHz Visteon Corporation FCC ID: NT8-FPK8I5DTR2 UL-RPT-RP-14374669-616 IC: 3043A- FPK8I5DTR2 UL International Germany GmbH Muhammad Faiq Khan 20.04.2023 Hedelfinger Str. 61/ 70327 Stuttgart/ Germany Template version: 2.0 Page 2 of 3 Photo 2: Radiated Test Setup from 30 MHz to 1 GHz Photo 1: Radiated Test Setup from 30 MHz to 1 GHz Visteon Corporation FCC ID: NT8-FPK8I5DTR2 UL-RPT-RP-14374669-616 IC: 3043A- FPK8I5DTR2 UL International Germany GmbH Muhammad Faiq Khan 20.04.2023 Hedelfinger Str. 61/ 70327 Stuttgart/ Germany Template version: 2.0 Page 3 of 3 2. Emission Bandwidth ( 99% / 20 dB) Photo 5: (99% / 20 dB) Bandwidth Test Setup Photo 6: (99% / 20 dB) Bandwidth Test Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |
Battery Pack Control Module (BPCM)
Equipment Class
JAB - Part 15 Class B Digital DeviceBattery Pack Control Module (BPCM)
Equipment Class
DTS - Digital Transmission System
Bluetooth Telematics Device
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
BT Unit
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterSense Line Assembly (SLA)
Equipment Class
JAB - Part 15 Class B Digital Device