Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC ID: NW9-9000RCR Front View of Device
FCC ID: NW9-9000RCR Bottom View of Device
FCC ID: NW9-9000RCR Front View of the Printed Wiring Board
FCC ID: NW9-9000RCR Bottom View of the Printed Wiring Board
Date: 2000-04-10 TEST REPORT Page 1 of 8 No.: HM102328 Law Man KitKitty ChoyPatrick Wong Testing EngineerVerify byPatrick Wong for Managing Director APPLICANT: (CODE : SKC001) SKY CITY INT’L LTD. 25/F., North Point Asia-Pacific Centre, 10 North Point Road, North Point, Hong Kong DATE OF SAMPLES RECEIVED: 2000-03-15 TEST DURATION 2000-04-06 DESCRIPTION OF SAMPLE(S): A sample of product said to be: Product:MULTI-FUNCTION REMOTE CONTROL LANTERN Manufacturer:SKY CITY INT’L LTD. Model Number:SL9000RC Brand Name:N/A Rating:12Vd.c. 300mA with Jack Origin:CHINA Additional Model Number:SL9000ARC, SL9000WRC, SL9000SWRC, SL9000MWRC, SL9000AMRC, SL9000ASRC, SCD9000RC, SCD9000ARC, SCD9000WRC, SCD9000SWRC, SCD9000MWRC, SCD9000AWRC, SCD9000ASRC The AC Adaptor used for the test was a Model: LF12300D-41, Input: 120V a.c. 60Hz, Output: 12V d.c. 300mA INVESTIGATIONS REQUESTED: Measurement to the relevant clauses of F.C.C. Rules and Regulations Part 15 Subpart B - Unintentional Radiator. RESULT/ REMARK: Please see attached sheet(s). CONCLUSION: From the measurement data obtained, the tested sample was considered to have COMPLIED after modification by customer with the clause 15.109(a) for the Receiver Section of Federal Communication Rules and Regulation Part 15 and ANSI C63.4-1992 Section 12.1.1.1-2. TEST EQUIPMENT AUDIT: Please see Appendix A Date: 2000-04-10 TEST REPORT Page 2 of 8 No.: HM102328 T E S T S U M M A R Y (A)Measurement of Radiated Emissions .............................................Satisfactory (B)Line Conducted Voltage Test. .......................................................Satisfactory T E S T D A T A Please refer to the attached result sheets. Date: 2000-04-10 TEST REPORT Page 3 of 8 No.: HM102328 *** RECEIVER SECTION *** (A) Measurement of Radiated Interference TEST REFERENCE: FCC Rules Part 15 Subpart B section 15.109(a) TEST CONDITION : Normal TEST DATE : 2000.04.06 ================================================================== EmissionMeterPolarizationAntennaField Strength FCC FrequencyReadingFactor(at 3m) Limit MHzdB( μ V)H-VdBdB( μ V/m) μ V/m μ V/m ##319.85422.0H+19.541.5118.9200 639.708<1.0+<28.5<29.529.9200 959.562<1.0+<25.8<26.821.9500 1279.416<1.0+<26.2<27.222.9500 1599.270<1.0+<28.0<29.028.2500 1919.124<1.0+<28.5<29.529.9500 2238.978<1.0+<30.6<31.638.0500 2558.832<1.0+<32.0<33.044.7500 2878.686<1.0+<33.2<34.251.3500 3198.540<1.0+<33.3<34.351.9500 ================================================================== ============SUMMARY=========== All data is within limits ============================================================== Broad-band Antennas were used and both polarizations of emissions were measured Polarizations at highest reading indicated as: H -- HorizontalV -- Vertical ============================================================== Date: 2000-04-10 TEST REPORT Page 4 of 8 No.: HM102328 NOTES FOR THE RADIATION MEASUREMENT (1) Test site facility: Open field test site located at Taipo (Hong Kong) with a metal ground plane on filed with the FCC pursuant to section 2.948 of the FCC Rules. (2) Distance between the ET and measuring antenna: 3 meters. (3) Measuring instrumentations: CISPR Quasi-peak type field strength meter (25 MHz - 1000 MHz and 1GHz-18GHz ).6dB bandwidth set at 120KHz. Also, peak level of the fundamental emissions was measured in order to determine compliance with the 20dB peak to average limit specified in Section 15.231 of the FCC new Rules. (4) Measuring antenna: Broad band antenna for the frequency range 25-1000 MHz, connected with 10 meters coaxial cable.Horn antenna for the frequency range 1-18 GHz, connected with high frequency coaxial cable.Cable loss of the coaxial cable. Cable included in the Antenna Factor for measurement data. The antenna are capable of measuring both horizontal and vertical polarizations. (5) Frequency range scanned: The frequency range from 25 MHz to 1000 MHz had been searched. Readings of the highest emissions relating to the limit were reported as above. (6) Arrangement of EUT: During the test, the sample was operated at rated supply voltage and arranged for maximum emissions. (7) Measuring Procedure: In accordance with the relevant clauses of the FCC Rules Part 15 section 15.109(a) and ANSI C63.4:1992 section 12.1.1.1-2. For superregenerative receivers, an independent signal generator had been used to radiated an unmodulated were (cw) signal to the receiver at its operating frequency in order to “cohere” or resolve the individual components of the characteristic broadband emission from such a receiver. The level of such signal may need to be adjusted in order to accomplish this. (8) Measuring Uncertainty: The calculated uncertainty for measurement performed at 3M test distance are:- 30MHz to 300MHz = ± 3.7dB, 300MHz to 1000MHz = + 3.0dB/-2.7dB. 1GHz to 18GHz = +3.3dB/-3.4dB. Remark: Purpose of this test is to provide the Applicant with the necessary test data of their device for the submission to FCC with application for Equipment Authorization under FCC’s Equipment Authorization Program. This test itself is not an Approval Test. Date: 2000-04-10 TEST REPORT Page 5 of 8 No.: HM102328 (B) Measurement of Line-Conducted Voltage onto AC Power Line TEST REFERENCE:FCC Rules Part 15 Subpart B Section 15.107(a) (Class B) TEST CONDITION:Normal TEST DATE:2000-04-10 (1) Between "Live” and "Ground” ======================================================================== == Frequency Range of EmissionMaximum Measured Radio NoiseFCC Limit (Class B) MHzdB( μμ V) μμ V μμ V 0.45-0.8025.4918.81250.00 0.80-1.6016.446.64250.00 1.60-3.000.001.00250.00 3.00-5.000.001.00250.00 5.00-7.000.001.00250.00 7.00-9.000.001.00250.00 9.00-11.000.001.00250.00 11.00-13.000.001.00250.00 13.00-15.000.001.00250.00 15.00-17.000.001.00250.00 17.00-19.000.001.00250.00 19.00-21.000.001.00250.00 21.00-23.000.001.00250.00 23.00-25.000.001.00250.00 25.00-27.000.001.00250.00 27.00-30.0011.333.69250.00 ====================================================…
Text truncated - open the document above for the full version.
10 Dai Wang St., Taipo Ind'l Estate · NT · Hong Kong
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 319.854 MHz - 319.854 MHz | - |

Multi-Function Lantern Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Multi-Function Lantern
Equipment Class
CXX - Communications Rcvr for use w/ licensed Tx and CBs
CYY - Communications Receiver used w/Pt 15 Transmitter
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
RECHARGEABLE REMOTE CONTROL LANTERN
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
CRR - Superregenerative Receiver
Equipment Class
CRR - Superregenerative Receiver