FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Diset, S.A./
  3. NXM-C15102

NXM-C15102KURIO MOTION

Diset, S.A.
KURIO MOTION - FCC ID NXM-C15102 - Diset, S.A.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 07, 2015
Application Purpose
Original Equipment
Date of Application
Jul 07, 2015
Equipment Note
KURIO MOTION
Frequency Range
2412.00000000 - 2462.00000000
Company
Diset, S.A.
Country
Spain

Documents & Files

Select a file to view

Users Manual

β†—

Attestation Statements

β†—
β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

RF Exposure Info

β†—

Test Report

β†—
β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

CATALANA de INVESTIGACION y DESARROLLO de ELECTRONICA INTERACTIVE S.L.U Viladecans Business Park, Edificio Brasil, C/ Catalunya, 83-85 Pl.1 B1, 08840 VILADECANS - BARCELONA, SPAIN Tel: +33 4 74 99 14 93 Fax: +33 4 74 99 06 61 http://www.group-kd.com 2015/6/26 FCC ID: NXM-C15102 We hereby declare that our device with the FCC ID above does not initiate and it can not be configured to initiate any transmission on any non-US frequencies or unauthorized frequencies. This includes probes, beacons, and ad-hoc mode transmissions. Our operation is limited to the following frequencies and modes: 802.11b Channel 1 (2412MHz) – Channel 11 (2462MHz) 802.11g Channel 1 (2412MHz) – Channel 11 (2462MHz) 802.11n (20MHz) Channel 1 (2412MHz) – Channel 11 (2462MHz) 802.11n (40MHz) Channel 3 (2422MHz) – Channel 9 (2452MHz) BT 2.1 + EDR Channel 0 (2402MHz) – Channel 78 (2480MHz) Name : Nicolas Cherrier Title : Safety manager Signature:

Attestation Statements

CATALANA de INVESTIGACION y DESARROLLO de ELECTRONICA INTERACTIVE S.L.U DATE:2015/6/26 FCC DECLARATION OF CONFORMITY (DoC) Trade Name(s): CIDE INTERACTIVE FCC ID: NXM-C15102 Model Number(s): C15102 Our device above has been tested and found to be compliant with the FCC Part 15 Class B limits as a computer peripheral. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Details of test lab and documentation Test Lab Name: BUREAU VERITAS HONG KONG LIMITED, EMC CENTRE FCC Test Site Accreditation Number (as seen on FCC website): 945348 Test report number and issue date: (5215)161-1119 / Jun 12, 2015 Declaring Party Name, Nicolas Cherrier Title, Safety manager Signature

External Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 4 Report Version 1 Reference No.: 150513N003 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 4 Report Version 1 Reference No.: 150513N003 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 4 Report Version 1 Reference No.: 150513N003 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 4 Report Version 1 Reference No.: 150513N003

Internal Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version 1 Reference No.: 150513N003 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version 1 Reference No.: 150513N003 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version 1 Reference No.: 150513N003 ANT

RF Exposure Info

FCC SAR Test Report Report Format Version 5.0.0 Page No. : 1 of 24 Report No. : SA150515E02 Issued Date : Jun. 08, 2015 FCC SAR Test Report Report No. : SA150515E02 Applicant : CATALANA de INVESTIGACION y DESARROLLO de ELECTRONICA INTERACTIVE S.L.U Address : Viladecans Business Park, Edificio Brasil, C/ Catalunya, 83-85 Pl.1 B1, 08840 VILADECANS - BARCELONA, SPAIN Product : KURIO MOTION FCC ID : NXM-C15102 Brand : CIDE INTERACTIVE Model No. : C15102 Standards : FCC 47 CFR Part 2 (2.1093) / IEEE C95.1:1992 / IEEE 1528:2003 IEEE 1528a-2005 / KDB 865664 D01 v01r03 / KDB 865664 D02 v01r01 KDB 248227 D01 v02 / KDB 447498 D01 v05r02 / KDB 616217 D04 v01r01 Sample Received Date : May 15, 2015 Date of Testing : May 27, 2015 CERTIFICATION: The above equipment have been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., China Branch - Dongguan Lab, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s SAR characteristics under the conditions specified in this report. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval, or endorsement by A2LA or any government agencies. No: 2951.01 Prepared By : Rona Chen / Specialist Approved By : Gordon Lin / Assistant Manager This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. FCC SAR Test Report Report Format Version 5.0.0 Page No. : 2 of 24 Report No. : SA150515E02 Issued Date : Jun. 08, 2015 Table of Contents Release Control Record ............................................................................................................................................................... 3 1. Summary of Maximum SAR Value ....................................................................................................................................... 4 2. Description of Equipment Under Test ................................................................................................................................. 5 3. SAR Measurement System ................................................................................................................................................... 6 3.1 Definition of Specific Absorption Rate (SAR) ............................................................................................................... 6 3.2 SPEAG DASY System ................................................................................................................................................. 6 3.2.1 Robot.................................................................................................................................................................. 7 3.2.2 Probes ................................................................................................................................................................ 8 3.2.3 Data Acquisition Electronics (DAE) .................................................................................................................... 8 3.2.4 Phantoms ........................................................................................................................................................... 9 3.2.5 Device Holder ..................................................................................................................................................... 9 3.2.6 System Validation Dipoles ................................................................................................................................ 10 3.2.7 Tissue Simulating Liquids ................................................................................................................................. 10 3.3 SAR System Verification ............................................................................................................................................ 13 3.4 SAR Measurement Procedure ................................................................................................................................... 14 3 .4.1 Area & Zoom Scan Procedure ......................................................................................................................... 14 3.4.2 Volume Scan Procedure................................................................................................................................... 14 3 .4.3 Power Drift Monitoring ...................................................................................................................................... 15 3.4.4 Spatial Peak SAR Evaluation .............................................…

Text truncated - open the document above for the full version.

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 56 Report Version 1 Test Report No.: RF150513N003-4 TEST REPORT Applicant CATALANA de INVESTIGACION y DESARROLLO de ELECTRONICA INTERACTIVE S.L.U Address Viladecans Business Park, Edificio Brasil, C/ Catalunya, 83-85 Pl.1 B1, 08840 VILADECANS - BARCELONA, SPAIN Manufacturer or Supplier Foshan City NanHai District XinHe XinMei Toys Factory Address Yongan Industrial Zone, Guanyao, Nanhai District, Foshan, Guangdong, China. Product KURIO MOTION Brand Name CIDE INTERACTIVE Model C15102 Additional Model & Model Difference N/A Date of tests May 13, 2015 ~ May 27, 2015 The tests have been carried out according to the requirements of the following standard: FCC Part 15, Subpart C, Section 15.247 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Yuqiang Yin Project Engineer / EMC Department Approved by Glyn He Supervisor / EMC Department Date: May 28, 2015 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 56 Report Version 1 Test Report No.: RF150513N003-4 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 4 1 SUMMARY OF TEST RESULTS .................................................................................................... 5 2 MEASUREMENT UNCERTAINTY ................................................................................................ 5 3 GENERAL INFORMATION ............................................................................................................ 6 3.1 GENERAL DESCRIPTION OF EUT........................................................................................... 6 3.2 DESCRIPTION OF TEST MODES............................................................................................. 7 3.2.1 CONFIGURATION OF SYSTEM UNDER TEST ............................................................... 8 3.2.2 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................................... 8 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ........................................................... 11 3.4 DESCRIPTION OF SUPPORT UNITS ...................................................................................... 11 4 TEST TYPES AND RESULTS ...................................................................................................... 12 4.1 CONDUCTED EMISSION MEASUREMENT ........................................................................... 12 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ............................................... 12 4.1.2 TEST INSTRUMENTS ..................................................................................................... 12 4.1.3 TEST PROCEDURES ..................................................................................................... 13 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................... 13 4.1.5 TEST SETUP ................................................................................................................... 14 4.1.6 EUT OPERATING CONDITIONS .................................................................................... 14 4.1.7 TEST RESULTS .............................................................................................................. 15 4.2 RADIATED EMISSION MEASUREMENT ................................................................................ 17 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT .................................................... 17 4.2.2 TEST INSTRUMENTS ..................................................................................................... 18 4.2.3 TEST PROCEDURES ..................................................................................................... 19 4.2.4 DEVIATION FROM TEST STANDARD ........................................................................... 19 4.2.5 TEST SETUP ................................................................................................................... 20 4.2.6 EUT OPERATING CONDITIONS .................................................................................... 20 4.2.7 TEST RESULTS .............................................................................................................. …

Text truncated - open the document above for the full version.

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 53 Report Version 1 Test Report No.: RF150513N003-3 TEST REPORT Applicant CATALANA de INVESTIGACION y DESARROLLO de ELECTRONICA INTERACTIVE S.L.U Address Viladecans Business Park, Edificio Brasil, C/ Catalunya, 83-85 Pl.1 B1, 08840 VILADECANS - BARCELONA, SPAIN Manufacturer or Supplier Foshan City NanHai District XinHe XinMei Toys Factory Address Yongan Industrial Zone, Guanyao, Nanhai District, Foshan, Guangdong, China. Product KURIO MOTION Brand Name CIDE INTERACTIVE Model C15102 Additional Model & Model Difference N/A Date of tests May 13, 2015 ~ May 27, 2015 the tests have been carried out according to the requirements of the following standards: FCC Part 15, Subpart C, Section 15.247 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Yuqiang Yin Project Engineer / EMC Department Approved by Glyn He Supervisor / EMC Department Date: May 28, 2015 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 53 Report Version 1 Test Report No.: RF150513N003-3 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 5 1 SUMMARY OF TEST RESULTS ...................................................................................................... 6 2 MEASUREMENT UNCERTAINTY .................................................................................................. 6 3 GENERAL INFORMATION.............................................................................................................. 7 3.1 GENERAL DESCRIPTION OF EUT ........................................................................................... 7 3.2 DESCRIPTION OF TEST MODES ............................................................................................. 7 3.2.1. CONFIGURATION OF SYSTEM UNDER TEST ............................................................... 9 3.2.2. TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................................... 9 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS .......................................................... 11 3.4 DESCRIPTION OF SUPPORT UNITS ..................................................................................... 11 4 TEST TYPES AND RESULTS ....................................................................................................... 12 4.1. CONDUCTED EMISSION MEASUREMENT ........................................................................... 12 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ............................................... 12 4.1.2 TEST INSTRUMENTS ..................................................................................................... 12 4.1.3 TEST PROCEDURES ..................................................................................................... 13 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................... 13 4.1.5 TEST SETUP ................................................................................................................... 14 4.1.6 EUT OPERATING CONDITIONS .................................................................................... 14 4.1.7 TEST RESULTS............................................................................................................... 15 4.2. RADIATED EMISSION AND BANDEDGE MEASUREMENT .................................................. 17 4.2.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT ...................... 17 4.2.2 TEST INSTRUMENTS .................................................................................................... 18 4.2.3 TEST PROCEDURES ..................................................................................................... 19 4.2.4 DEVIATION FROM TEST STANDARD ........................................................................... 20 4.2.5 TEST SETUP .................................................................................................................. 20 4.2.6 EUT OPERATING CONDITIONS ................................................................................... 20 4.2.7 TEST RESULTS .............................................................................................................. 21 4.3. NUMBER OF HOPPING …

Text truncated - open the document above for the full version.

Test Setup Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version 1 Reference No.: 150513N003 SET-UP FOR CONDUCTED EMISSION TEST Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version 1 Reference No.: 150513N003 SET-UP FOR RADIATED EMISSION TEST Frequency Range< 30MHz~1GHz > Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version 1 Reference No.: 150513N003 Frequency Range< Above 1GHz >

Contact Information

Applicant

Karine Matringe
[email protected]+33474990660Fax: +34933354485

Test Firm

Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchAlec Hu
[email protected]86-769-85935656Fax: 86-769-85991080

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz154.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. SAR compliance has been demonstrated as described in this filing. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except as evaluated in this filing. End-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements. The highest reported SAR value for body-worn use condition is 0.23 W/kg.

Other Applications from Diset, S.A.

Tablet PC - FCC ID NXM-C15150M - Diset, S.A.
NXM-C15150M

Tablet PC

Jul 08, 2015

Equipment Class

DTS - Digital Transmission System
KURIO XTREME 2 - FCC ID NXM-C15150I - Diset, S.A.
NXM-C15150I

KURIO XTREME 2

Jul 08, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
KURIO TAB2 - FCC ID NXM-C15105 - Diset, S.A.
NXM-C15105

KURIO TAB2

Jul 07, 2015

Equipment Class

DTS - Digital Transmission System
KURIO XTREME - FCC ID NXM-C14150 - Diset, S.A.
NXM-C14150

KURIO XTREME

Jul 22, 2014

Equipment Class

DTS - Digital Transmission System
Kurio Phone - FCC ID NXM-C14500 - Diset, S.A.
NXM-C14500

Kurio Phone

May 26, 2014

Equipment Class

PCE - PCS Licensed Transmitter held to ear