CATALANA de INVESTIGACION y DESARROLLO de ELECTRONICA INTERACTIVE S.L.U Viladecans Business Park, Edificio Brasil, C/ Catalunya, 83-85 Pl.1 B1, 08840 VILADECANS - BARCELONA, SPAIN Tel: +33 4 74 99 14 93 Fax: +33 4 74 99 06 61 http://www.group-kd.com 2015/6/26 FCC ID: NXM-C15150I We hereby declare that our device with the FCC ID above does not initiate and it can not be configured to initiate any transmission on any non-US frequencies or unauthorized frequencies. This includes probes, beacons, and ad-hoc mode transmissions. Our operation is limited to the following frequencies and modes: 802.11b Channel 1 (2412MHz) β Channel 11 (2462MHz) 802.11g Channel 1 (2412MHz) β Channel 11 (2462MHz) 802.11n (20MHz) Channel 1 (2412MHz) β Channel 11 (2462MHz) 802.11n (40MHz) Channel 3 (2422MHz) β Channel 9 (2452MHz) BT 2.1 + EDR Channel 0 (2402MHz) β Channel 78 (2480MHz) Name : Nicolas Cherrier Title : Safety manager Signature:
CATALANA de INVESTIGACION y DESARROLLO de ELECTRONICA INTERACTIVE S.L.U DATEοΌ2015/6/26 FCC DECLARATION OF CONFORMITY (DoC) Trade Name(s): CIDE INTERACTIVE FCC ID : NXM-C15150I Model Number(s): C15150I Our device above has been tested and found to be compliant with the FCC Part 15 Class B limits as a computer peripheral. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Details of test lab and documentation Test Lab Name: BUREAU VERITAS HONG KONG LIMITED, EMC CENTRE FCC Test Site Accreditation Number (as seen on FCC website): 945348 Test report number and issue date: (5215)161-1119 / Jun 12, 2015 Declaring Party Name, Nicolas Cherrier Title, Safety manager Signature
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 4 Report Version 1 Reference No.: 150513N003 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 4 Report Version 1 Reference No.: 150513N003 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 4 Report Version 1 Reference No.: 150513N003 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 4 Report Version 1 Reference No.: 150513N003
Search|RSS |Updates |E-Filing |Initiatives |Consumers |Find People Office of Engineering and Technology FCC > FCC E-filing > Inquiry System Home Page > View Inquiry FCC Site Map OET Home Page Site Options Basic KDB Search Advanced KDB Search Submit an Inquiry Reply to an Inquiry Response Category List FAQ Search Major Guidance Publications Draft Laboratory Division Publications Draft Laboratory Division Publications (Expired) Draft Publication Moderation Policy Related Sites Equipment Authorization Presentations Equipment Authorization System (EAS) Telecommunications Certification Bodies (TCB) Measurement Procedures Reply to an OET Inquiry Response Currently Displaying Inquiry Tracking Number: 244227 Contact Information: Customer First Name: Sam Customer Last Name: Tung Telephone Number: +86-769-89982098 Extension: 8008 E-mail Address: [email protected] Address: Line 1: Line 2: P.O. Box: City: State: Zip Code: Country: Inquiry Details on 06/08/2015: First category: Equipment Authorization Process * Second category: Declaration of Conformity (DOC) [Equip Auth] Third category: Subject: Label requirement of the product sujected to multiple authorization procedures Inquiry: Dear Sir/Madam Good day? Based on KDB 784748, it's not required to label the statement of 15.19 (a) on the product that is subjected both of the FCC DoC and Certification procedures, but the DoC logo and FCC ID must be labelled, is it right? Looking forward your reply? Thanks & Regards? Sam Tung FCC Response on 06/08/2015: Go to our website: www.fcc.gov/oet/ea click on labelling guidelines KDB #784748 - Labelling Quick Guide for additional information. The device much have the appropriate FCC logo and FCC ID. The label on the device/produce shall be permanently affixed to the produce and shall be readily visible to the purchaser at the time of the purchase. The label must be designed to last the expected lifetime of the equiment in the environment in which the equipment may be operated andmust not be readily detachable. For more information, see Section 15.19 of the FCC Rules and Regulations. ---Reply from Customer on 06/08/2015--- Dear Sir/Madam Thanks for your quick reply! and may I understand that it's not compulsory to place the FCC compliance statement of 15.19 on the label for the product that is subjected to the FCC DoC and FCC certification prcedure? Sir, please give me a cleare answer because the manufacturer is doubt about this, thanks! (Quote from KDB784748 D01 Labelling Part 15 18 Guidelines v08 ) 7. Multiple Authorization Procedures: A device subject to multiple authorization procedures requires appropriate testing and labelling for each of the respective authorization procedures. As a general rule, the DoC text statement supersedes any Verification statement. For devices subject to DoC and Verification, or Certification and Verification, the labelling requirements for DoC or Certification need only apply. When a device is authorized under both the DoC and Certification procedures, the DoC logo and FCC ID (or FCC IDs if applicable) are required. (End of quote) Sincerely Sam Tung FCC Response on 06/09/2015: Page 1 of 2OET Inquiry System Inquiry Tracking Number 244227 2015-06-30https://apps.fcc.gov/oetcf/kdb/forms/ReplyToResponse2.cfm The FCC logo is to be displayed only on a device that require DoC approval. If the device requires certification, it must have a FCC ID number displayed on it. The compliance statement is to appear in the instruction manual or pamphlet supplied to the user. Please refer to the FCC Rules and Regulations for additional information. Thanks FCC Response on 06/10/2015: You received a response on June 9, 2015. Thanks Enter any additional comments below: *(This is a text only field. Users will be able to upload attachments after clicking on the "Proceed" button below) Proceed Clear Please use the Submit Inquiry link at www.fcc.gov/labhelp to send any comments or suggestions for this site Federal Communications Commission 445 12th Street, SW Washington, DC 20554 More FCC Contact Information... Phone: 888-CALL-FCC (225-5322) TTY: 888-TELL-FCC (835-5322) Fax: 202-418-0232 E-mail: [email protected] - Privacy Policy - Web Policies & Notices - Customer Service Standards - Freedom of Information Act Page 2 of 2OET Inquiry System Inquiry Tracking Number 244227 2015-06-30https://apps.fcc.gov/oetcf/kdb/forms/ReplyToResponse2.cfm
11.8 mm 26.7 mm 28.4 mm 17.30 mm 4.3 mm V01 (LG) : Legal mark ings update V04 ( LG ) : Legal mark ings update V02 (LG) : Legal mark ings update V05 ( LG ) : Legal mark ings update V03 (LG) : Legal mark ings update C15150I_ALL_AW_SLK_back_06_150707 Location on unit : Stand plate Location on unit : Bottom cover
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version 1 Reference No.: 150513N003 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version 1 Reference No.: 150513N003 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version 1 Reference No.: 150513N003 ANT
FCC SAR Test Report Report Format Version 5.0.0 Page No. : 1 of 24 Report No. : SA150515E02-2 Issued Date : Jun. 08, 2015 FCC SAR Test Report Report No. : SA150515E02-2 Applicant : CATALANA de INVESTIGACION y DESARROLLO de ELECTRONICA INTERACTIVE S.L.U Address : Viladecans Business Park, Edificio Brasil, C/ Catalunya, 83-85 Pl.1 B1, 08840 VILADECANS - BARCELONA, SPAIN Product : KURIO XTREME 2 FCC ID : NXM-C15150I Brand : CIDE INTERACTIVE Model No. : C15150I Standards : FCC 47 CFR Part 2 (2.1093) / IEEE C95.1:1992 / IEEE 1528:2003 IEEE 1528a-2005 / KDB 865664 D01 v01r03 / KDB 865664 D02 v01r01 KDB 248227 D01 v02 / KDB 447498 D01 v05r02 / KDB 616217 D04 v01r01 Sample Received Date : May 15, 2015 Date of Testing : May 27, 2015 CERTIFICATION: The above equipment have been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., China Branch - Dongguan Lab, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sampleβs SAR characteristics under the conditions specified in this report. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval, or endorsement by A2LA or any government agencies. No: 2951.01 Prepared By : Rona Chen / Specialist Approved By : Gordon Lin / Assistant Manager This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. FCC SAR Test Report Report Format Version 5.0.0 Page No. : 2 of 24 Report No. : SA150515E02-2 Issued Date : Jun. 08, 2015 Table of Contents Release Control Record ............................................................................................................................................................... 3 1. Summary of Maximum SAR Value ....................................................................................................................................... 4 2. Description of Equipment Under Test ................................................................................................................................. 5 3. SAR Measurement System ................................................................................................................................................... 6 3.1 Definition of Specific Absorption Rate (SAR) ............................................................................................................... 6 3.2 SPEAG DASY System ................................................................................................................................................. 6 3.2.1 Robot.................................................................................................................................................................. 7 3.2.2 Probes ................................................................................................................................................................ 8 3.2.3 Data Acquisition Electronics (DAE) .................................................................................................................... 8 3.2.4 Phantoms ........................................................................................................................................................... 9 3.2.5 Device Holder ..................................................................................................................................................... 9 3.2.6 System Validation Dipoles ................................................................................................................................ 10 3.2.7 Tissue Simulating Liquids ................................................................................................................................. 10 3.3 SAR System Verification ............................................................................................................................................ 13 3.4 SAR Measurement Procedure ................................................................................................................................... 14 3.4.1 Area & Zoom Scan Procedure ......................................................................................................................... 14 3.4.2 Volume Scan Procedure................................................................................................................................... 14 3.4.3 Power Drift Monitoring ...................................................................................................................................... 15 3.4.4 Spatial Peak SAR Evaluation .....................................β¦
Text truncated - open the document above for the full version.
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 53 Report Version 1 Test Report No.: RF150513N003-1 TEST REPORT Applicant CATALANA de INVESTIGACION y DESARROLLO de ELECTRONICA INTERACTIVE S.L.U Address Viladecans Business Park, Edificio Brasil, C/ Catalunya, 83-85 Pl.1 B1, 08840 VILADECANS - BARCELONA, SPAIN Manufacturer or Supplier Foshan City NanHai District XinHe XinMei Toys Factory Address Yongan Industrial Zone, Guanyao, Nanhai District, Foshan, Guangdong, China. Product KURIO XTREME 2 Brand Name CIDE INTERACTIVE Model C15150I Additional Model & Model Difference N/A Date of tests May 13, 2015 ~ May 27, 2015 the tests have been carried out according to the requirements of the following standards: FCC Part 15, Subpart C, Section 15.247 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Yuqiang Yin Project Engineer / EMC Department Approved by Glyn He Supervisor / EMC Department Date: May 28, 2015 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 53 Report Version 1 Test Report No.: RF150513N003-1 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 5 1 SUMMARY OF TEST RESULTS ...................................................................................................... 6 2 MEASUREMENT UNCERTAINTY .................................................................................................. 6 3 GENERAL INFORMATION.............................................................................................................. 7 3.1 GENERAL DESCRIPTION OF EUT ........................................................................................... 7 3.2 DESCRIPTION OF TEST MODES ............................................................................................. 7 3.2.1. CONFIGURATION OF SYSTEM UNDER TEST ............................................................... 9 3.2.2. TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................................... 9 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS .......................................................... 11 3.4 DESCRIPTION OF SUPPORT UNITS ..................................................................................... 11 4 TEST TYPES AND RESULTS ....................................................................................................... 12 4.1. CONDUCTED EMISSION MEASUREMENT ........................................................................... 12 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ............................................... 12 4.1.2 TEST INSTRUMENTS ..................................................................................................... 12 4.1.3 TEST PROCEDURES ..................................................................................................... 13 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................... 13 4.1.5 TEST SETUP ................................................................................................................... 14 4.1.6 EUT OPERATING CONDITIONS .................................................................................... 14 4.1.7 TEST RESULTS............................................................................................................... 15 4.2. RADIATED EMISSION AND BANDEDGE MEASUREMENT .................................................. 17 4.2.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT ...................... 17 4.2.2 TEST INSTRUMENTS .................................................................................................... 18 4.2.3 TEST PROCEDURES ..................................................................................................... 19 4.2.4 DEVIATION FROM TEST STANDARD ........................................................................... 20 4.2.5 TEST SETUP .................................................................................................................. 20 4.2.6 EUT OPERATING CONDITIONS ................................................................................... 20 4.2.7 TEST RESULTS .............................................................................................................. 21 4.3. NUMBER OF HOPPIβ¦
Text truncated - open the document above for the full version.
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 56 Report Version 1 Test Report No.: RF150513N003-2 TEST REPORT Applicant CATALANA de INVESTIGACION y DESARROLLO de ELECTRONICA INTERACTIVE S.L.U Address Viladecans Business Park, Edificio Brasil, C/ Catalunya, 83-85 Pl.1 B1, 08840 VILADECANS - BARCELONA, SPAIN Manufacturer or Supplier Foshan City NanHai District XinHe XinMei Toys Factory Address Yongan Industrial Zone, Guanyao, Nanhai District, Foshan, Guangdong, China. Product KURIO XTREME 2 Brand Name CIDE INTERACTIVE Model C15150I Additional Model & Model Difference N/A Date of tests May 13, 2015 ~ May 27, 2015 The tests have been carried out according to the requirements of the following standard: FCC Part 15, Subpart C, Section 15.247 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Yuqiang Yin Project Engineer / EMC Department Approved by Glyn He Supervisor / EMC Department Date: May 28, 2015 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 56 Report Version 1 Test Report No.: RF150513N003-2 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 4 1 SUMMARY OF TEST RESULTS .................................................................................................... 5 2 MEASUREMENT UNCERTAINTY ................................................................................................ 5 3 GENERAL INFORMATION ............................................................................................................ 6 3.1 GENERAL DESCRIPTION OF EUT........................................................................................... 6 3.2 DESCRIPTION OF TEST MODES............................................................................................. 7 3.2.1 CONFIGURATION OF SYSTEM UNDER TEST ............................................................... 8 3.2.2 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................................... 8 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ........................................................... 11 3.4 DESCRIPTION OF SUPPORT UNITS ...................................................................................... 11 4 TEST TYPES AND RESULTS ...................................................................................................... 12 4.1 CONDUCTED EMISSION MEASUREMENT ........................................................................... 12 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ............................................... 12 4.1.2 TEST INSTRUMENTS ..................................................................................................... 12 4.1.3 TEST PROCEDURES ..................................................................................................... 13 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................... 13 4.1.5 TEST SETUP ................................................................................................................... 14 4.1.6 EUT OPERATING CONDITIONS .................................................................................... 14 4.1.7 TEST RESULTS .............................................................................................................. 15 4.2 RADIATED EMISSION MEASUREMENT ................................................................................ 17 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT .................................................... 17 4.2.2 TEST INSTRUMENTS ..................................................................................................... 18 4.2.3 TEST PROCEDURES ..................................................................................................... 19 4.2.4 DEVIATION FROM TEST STANDARD ........................................................................... 19 4.2.5 TEST SETUP ................................................................................................................... 20 4.2.6 EUT OPERATING CONDITIONS .................................................................................... 20 4.2.7 TEST RESULTS ............................................................................................................β¦
Text truncated - open the document above for the full version.
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version 1 Reference No.: 150513N003 SET-UP FOR CONDUCTED EMISSION TEST Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version 1 Reference No.: 150513N003 SET-UP FOR RADIATED EMISSION TEST Frequency Range< 30MHz~1GHz > Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version 1 Reference No.: 150513N003 Frequency Range< Above 1GHz >
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 5.00 mW |

Tablet PC
Equipment Class
DTS - Digital Transmission System
KURIO MOTION
Equipment Class
DTS - Digital Transmission System
KURIO TAB2
Equipment Class
DTS - Digital Transmission System
KURIO XTREME
Equipment Class
DTS - Digital Transmission System
Kurio Phone
Equipment Class
PCE - PCS Licensed Transmitter held to ear