FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. MOBASE ELECTRONICS CO., LTD./
  3. NYOSEKS-FS10APM

NYOSEKS-FS10APMRemote Keyless Entry System

MOBASE ELECTRONICS CO., LTD.
Remote Keyless Entry System - FCC ID NYOSEKS-FS10APM - MOBASE ELECTRONICS CO., LTD.
Click to zoom

Application Details

Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Date of Grant
Aug 01, 2011
Application Purpose
Original Equipment
Date of Application
Aug 01, 2011
Equipment Note
Remote Keyless Entry System
Frequency Range
315.00000000 - 315.00000000
Company
MOBASE ELECTRONICS CO., LTD.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

0.GENERAL 0.1.Make Shinchang Electrics Co.,Ltd. 0.2.Model No. - Transmitter : SEKS-TF10ATx - Receiver : SEKSFS10APM 0.3.Name and address of manufacturer Shinchang Electrics Co.,Ltd. 734-2, Wonshi-Dong, Ansan-Si, Kyonggi-Do, Korea. 0.4.Address of assembly plant Shinchang Electrics Co.,Ltd. 734-2, Wonshi-Dong, Ansan-Si, Kyonggi-Do, Korea. THN Co., Ltd. 973-3 Galsan-Dong, Dalseo-Gu, Daegu, korea. 2.PRODUCT SPECIFICATION 2.1SCOPE OF REMOTE KEYLESS ENTRY SYSTEM 2.1.1KEY PART : TRANSMITTER is inside of the REMOTE KEY, and it sends the ROLLING CODE to the RECEIVER by Radio Frequency. 2.1.2RECEIVER : It receives the ROLLING CODE and decodes that, thereafter RECEIVER drives the actuator. 2.2SPECIFICATIONS 2.2.1TRANSMITTER 2.2.2RECEIVER Storage temperature range -30 ~ 80°C ModulationFSK ITEM SPECIFICATION Rated supply voltage DC 3V Operating voltage range DC 2.5 ~ 3.2V Operating temperature range -20 ~+60°C Frequency315MHz Code Rolling Code(Hopping Algorithm) Battery life 2 Year(10Times/Day)(Lithium 3V 1EA) Electric field strength 10mW (433.92MHz) Below than 5mA Operating Temperature - 30 ~ + 80°C Max Humidity95% Standby Current (in alarm setting condition) Specification Item DC 9 ~ 16V Operating Voltage DC 12V Rated Supply Voltage 3.USER MANUAL 3.1NAME : IPM system - This system is IPM and inculdes RKE. - RKE in IPM system is intended for auto door lock or unlock or PANIC in vehicle. - This IPM system is to be installde on motor vehicles as *OE item. *OE : Original Equipment. *IPM : Anti Theft Alarm System. *RKE : Remote Keyless Entry. 3.2SYSTEM CONSTRUCTION 3.2.1SYSTEM IN VEHICLE 3.2.1SYSTEM FOR TEST * Through the use of lamp, operating state is displayed by lamp. lamp 'ON' means that actuator is operated by door lock or unlock or PANIC output signal. ANTENNA BATTERY DOOR ACTUATOR ROLLING CODE ANTENNA RECEIVER BATTERY lamp RECEIVER LOCK or UNLOCK or PANIC DATA ROLLING CODE (315MHz) 2.3Operating summary ① TRANSMITTER's button is pushed. ② TRANSMITTER sends the code by radio frequency. ③ RECEIVER gets the code and decodes it. ④ RECEIVER judges the code whether it is right code or not. ⑤ RECEIVER checks door lock or unlock ⑥ RECEIVER drives the actuator. 2.3.1LOCK & UNLOCK ① If LOCK or UNLOCK button is pushed for less than 1 sec, then TRANSMITTER sends the LOCK or UNLOCK DATA. 2.4Caution ① Danger of explosion if battery is incorrectly replaced. ② Replace only with the same or equivalent type recommended by the manufacturer. ③ Dispose of used batteries according to the manufacturer's instructions.

Cover Letter(s)

SHINCHANG ELECTRICS CO., LTD. 734-2, Wonshi-dong, Danwon-gu, Ansan-si, Gyunggi-do, 425-090, Korea Tel: +82-41-0910-472, Fax: +82-41-9010-419 Date: May 07, 2008 Compliance Certification Services Certification Division 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize Mr. Y.K.Kwon/Director of ONETECH Corp., and hereafter referred to as ONETECH, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Mr. Y.K.Kwon of ONETECH on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing CCS as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Mr. Woo, Jung / Director Shinchang Electrics Co., Ltd.

Cover Letter(s)

SHINCHANG ELECTRICS CO., LTD. 734-2, Wonshi-dong, Danwon-gu, Ansan-si, Gyunggi-do, 425-090, Korea Tel: +82-41-901-0472 Fax: +82-41-901-0419 Date: July 29, 2011 FCC Laboratory 7435 Oakland Mills Road Columbia, MD 21046 Attention: Application Examiner Reviewing Engineer Re: Request for confidentiality per Section 0.459 of FCC Rules Applicant: Shinchang Electrics Co., Ltd. FCC ID: NYOSEKS-FS10APM To whom it may concern, Request is hereby submitted, on behalf of my client, Shinchang Electrics, Co., Ltd, to withhold from public review certain portions of the application for equipment certification for the referenced FCC identifier. In particular, the following sections of the application and report are requested to be kept confidential: Schematics Block Diagram Parts List Rationale for request for confidentiality: Shinchang Electrics Co., Ltd has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the confidential portions of this application to competitors would give them competitive advantage in developing similar products. If you have questions or need further information, please contact the undersigned. Sincerely Yours, Mr. Woo, Jung / Director Shinchang Electrics Co., Ltd.

External Photos

FCC ID.: NYOSEKS-FS10APM Page 1 of 6 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID.: NYOSEKS-FS10APM Page 2 of 6 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID.: NYOSEKS-FS10APM Page 3 of 6 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID.: NYOSEKS-FS10APM Page 4 of 6 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID.: NYOSEKS-FS10APM Page 5 of 6 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID.: NYOSEKS-FS10APM Page 6 of 6 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904)

ID Label/Location Info

FCC ID.: NYOSEKS-FS10APM Page 1 of 1 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) IDENTIFICATION LABEL: PROPOSED FCC ID LABEL The FCC ID shall be permanently affixed to the top side of the equipment This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. Made in Korea FCC ID : NYOSEKS-FS10APM FCC ID AREA

Internal Photos

FCC ID.: NYOSEKS-FS10APM Page 1 of 5 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID.: NYOSEKS-FS10APM Page 2 of 5 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID.: NYOSEKS-FS10APM Page 3 of 5 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID.: NYOSEKS-FS10APM Page 4 of 5 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID.: NYOSEKS-FS10APM Page 5 of 5 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904)

Test Report

Page 1 of 9 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) ELECTROMAGNETIC EMISSION C OMPLIANCE REPORT Test Report No. : E117R-064 AGR No. : A111A-067R Applicant : Shinchang Electrics Co., Ltd. Address : 734-2, Wonshi-dong, Danwon-gu, Ansan-si, Kyungki-do, 425-090, Korea Manufacturer : Shinchang Electrics Co., Ltd. Address : 734-2, Wonshi-dong, Danwon-gu, Ansan-si, Kyungki-do, 425-090, Korea Type of Equipment : Remote Keyless Entry System FCC ID : NYOSEKS-FS10APM IC Certification No. : 3109A-SEKSFS10APM Model No. : SEKSFS10APM Serial number : N/A Total page of Report : 9 pages (including this page) Date of Incoming : June 17, 2011 Date of issuing : July 26, 2011 SUMMARY The equipment complies with the regulation; FCC CFR 47 PART 15 SUBPART B, Section 15.101 and IC RSS-210 Issue 8 and RSS-Gen Issue 3. This test report contains only the result of a single test of the sample supplied for the examination. It is not a general valid assessment of the features of the respective products of the mass-production. Prepared by: Reviewed by: Young-Min, Choi / Chief Engineer Y. K. Kwon / Exe. Managing Director EMC/RF Center EMC/RF Center ONETECH Corp. ONETECH Corp. Page 2 of 9 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) CONTENTS Page 1. VERIFICATION OF COMPLIANCE .............................................................................................................................. 3 2. GENERAL INFORMATION............................................................................................................................................. 4 2.1 PRODUCT DESCRIPTION.................................................................................................................................................. 4 2.2 MODEL DIFFERENCES:................................................................................................................................................... 4 2.3 RELATED SUBMITTAL(S) / GRANT(S)............................................................................................................................. 4 2.4 PURPOSE OF THE TEST.................................................................................................................................................... 4 2.5 TEST METHODOLOGY..................................................................................................................................................... 4 2.6 TEST FACILITY................................................................................................................................................................ 4 3. SYSTEM TEST CONFIGURATION................................................................................................................................ 5 3.1 JUSTIFICATION................................................................................................................................................................ 5 3.2 PERIPHERAL EQUIPMENT................................................................................................................................................ 5 3.3 MODE OF OPERATION DURING THE TEST........................................................................................................................ 5 3.4 EQUIPMENT MODIFICATIONS......................................................................................................................................... 5 3.5 CONFIGURATION OF TEST SYSTEM................................................................................................................................6 4. PRELIMINARY TEST ....................................................................................................................................................... 6 4.1 AC POWER LINE CONDUCTED EMISSION TEST............................................................................................................. 6 4.2 RADIATED EMISSION TEST............................................................................................................................................. 6 5. FINAL RESULT OF MEASURMENT ............................................................................................................................. 7 5.1 RADIATED EMISSION TEST............................................................................................................................................. 7 6. FIELD STRENGTH CALCULATION ............................................................................................................................. 8 7. LIST OF TEST EQUIPMENT........................................................................................................................................... 9 Page 3 of 9 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) 1. VERIFICATION OF COMPLIANCE APPLICANT : Shinchang Electrics Co., Ltd. ADDRESS : 734-2, Wonshi-don…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID. : NYOSEKS-FS10APM Page 1 of 1 Report No.: E117R-064 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon 1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) Radiated Emission Test

Contact Information

Applicant

Ryu Hee-Tack(Head Project Manager)
[email protected]+82-31-8090-2611Fax: +82-31-8090-2609

Test Firm

ONETECH Corp.Ki Hong Nam
[email protected]82-31-799-9580Fax: 82-31-799-9599

Technical Specifications

#Rule PartsFrequency RangePower Output
115B315 MHz - 315 MHz-
Confidentiality
Long Term

Other Applications from MOBASE ELECTRONICS CO., LTD.

NYOMBECNEM2606

UNIT ASSY-WIRELESS CHARGING

Jul 21, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
NYOMBECNEE2606

UNIT ASSY-WIRELESS CHARGING

Jul 06, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
NYOMBECWPC2606

UNIT ASSY-WIRELESS CHARGING

Apr 28, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
NYOMBECFOB2505

Remote Keyless Entry Transmitter

Jul 06, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Rear Occupant Alert - FCC ID NYOMBECROA2207 - MOBASE ELECTRONICS CO., LTD.
NYOMBECROA2207

Rear Occupant Alert

Nov 08, 2023

Equipment Class

FDS - Part 15 Field Disturbance Sensor