Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
2.PRODUCT SPECIFICATION 2.1Scope of Remote Keyless Entry in BCM system. 21.1Key part : TRANSMITTER is inside of the remote key, and it sends the rolling code to the RECEIVER by radio frequency. 2.1.2RECEIVER : It receives the rolling code and decodes that, thereafter RECEIVER drives the actuator. 2.2Specification 2.2.1TRANSMITTER 2.2.2RECEIVER Storage temperature range -30 ~ 80°C ModulationFSK ITEM SPECIFICATION Rated supply voltage DC 3V Operating voltage range DC 2.5 ~ 3.2V Operating temperature range -20 ~+60°C Frequency 315.00MHz Code Rolling Code(Hopping Algorithm) - 30 ~ + 80°C Max Humidity95% Battery life 2 Year(10Times/Day)(Lithium 3V 1EA) Below than 5.5mA (in alarm setting condition) Standby Current Specification Item DC 9 ~ 16V Operating Voltage DC 12V Rated Supply Voltage Operating Temperature
SHINCHANG ELECTRICS CO., LTD. 734-2, Wonshi-dong, Danwon-gu, Ansan-si, Gyunggi-do, 425-090, Korea Tel: +82-41-0910-472, Fax: +82-41-9010-419 Date: May 07, 2008 Compliance Certification Services Certification Division 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize Mr. Y.K.Kwon/Director of ONETECH Corp., and hereafter referred to as ONETECH, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Mr. Y.K.Kwon of ONETECH on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing CCS as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Mr. Woo, Jung / Director Shinchang Electrics Co., Ltd.
SHINCHANG ELECTRICS CO., LTD. 734-2, Wonshi-dong, Danwon-gu, Ansan-si, Gyunggi-do, 425-090, Korea Tel: +82-41-901-0472, Fax: +82-41-901-0419 Date: January 18, 2010 FCC Laboratory 7435 Oakland Mills Road Columbia, MD 21046 Attention: Application Examiner Reviewing Engineer Re: Request for confidentiality per Section 0.459 of FCC Rules Applicant: Shinchang Electrics Co., Ltd. FCC ID: NYOSEKS-TF10ARX To whom it may concern, Request is hereby submitted, on behalf of my client, Shinchang Electrics, Co., Ltd, to withhold from public review certain portions of the application for equipment certification for the referenced FCC identifier. In particular, the following sections of the application and report are requested to be kept confidential: Schematics Block Diagram Rationale for request for confidentiality: Shinchang Electrics Co., Ltd has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the confidential portions of this application to competitors would give them competitive advantage in developing similar products. If you have questions or need further information, please contact the undersigned. Sincerely Yours, Mr. Woo, Jung / Director Shinchang Electrics Co., Ltd.
FCC ID. : NYOSEKS-TF10ARX Page 1 of 2 Report No.: E101R-029 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID. : NYOSEKS-TF10ARX Page 2 of 2 Report No.: E101R-029 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904)
FCC ID. : NYOSEKS-TF10ARX Page 1 of 1 Report No.: E101R-029 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) IDENTIFICATION LABEL: PROPOSED FCC ID LABEL The FCC ID shall be permanently affixed to the rear side of the equipment FCC ID AREA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. Made in Korea FCC ID : NYOSEKS-TF10ARX
FCC ID. : NYOSEKS-TF10ARX Page 1 of 5 Report No.: E101R-029 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID. : NYOSEKS-TF10ARX Page 2 of 5 Report No.: E101R-029 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID. : NYOSEKS-TF10ARX Page 3 of 5 Report No.: E101R-029 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID. : NYOSEKS-TF10ARX Page 4 of 5 Report No.: E101R-029 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID. : NYOSEKS-TF10ARX Page 5 of 5 Report No.: E101R-029 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904)
FCC ID. : NYOSEKS-TF10ARX Page 1 of 9 Report No.: E101R-029 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) ELECTROMAGNETIC EMISSION C OMPLIANCE REPORT FOR SUPERHETRODYNE RECEIVER Test Report No. : E101R-029 AGR No. : A101A-026 Applicant : Shinchang Electrics Co., Ltd. Address : 734-2, Wonshi-dong, Danwon-gu, Ansan-si, Kyungki-do, 425-090, Korea Manufacturer : Shinchang Electrics Co., Ltd. Address : 734-2, Wonshi-dong, Danwon-gu, Ansan-si, Kyungki-do, 425-090, Korea Type of Equipment : Remote Keyless Entry System FCC ID : NYOSEKS-TF10ARX Model No. : SEKS-TF10ARx Serial number : N/A Total page of Report : 9 pages (including this page) Date of Incoming : January 07, 2010 Date of issuing : January 18, 2010 SUMMARY The equipment complies with the regulation; FCC PART 15 SUBPART B §15.101 This test report contains only the result of a single test of the sample supplied for the examination. It is not a general valid assessment of the features of the respective products of the mass-production. Prepared by: Reviewed by: Young-Min, Choi / Asst. Chief Engineer Y. K. Kwon / Managing Director EMC/RF Center EMC/RF Center ONETECH Corp. ONETECH Corp. FCC ID. : NYOSEKS-TF10ARX Page 2 of 9 Report No.: E101R-029 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) CONTENTS Page 1. VERIFICATION OF COMPLIANCE .............................................................................................................................. 3 2. GENERAL INFORMATION............................................................................................................................................. 4 2.1 PRODUCT DESCRIPTION.................................................................................................................................................. 4 2.2 MODEL DIFFERENCES:................................................................................................................................................... 4 2.3 RELATED SUBMITTAL(S) / GRANT(S)............................................................................................................................. 4 2.4 PURPOSE OF THE TEST.................................................................................................................................................... 4 2.5 TEST METHODOLOGY..................................................................................................................................................... 4 2.6 TEST FACILITY................................................................................................................................................................ 4 3. SYSTEM TEST CONFIGURATION................................................................................................................................ 5 3.1 JUSTIFICATION................................................................................................................................................................ 5 3.2 PERIPHERAL EQUIPMENT................................................................................................................................................ 5 3.3 MODE OF OPERATION DURING THE TEST........................................................................................................................ 5 3.4 EQUIPMENT MODIFICATIONS......................................................................................................................................... 5 3.5 CONFIGURATION OF TEST SYSTEM................................................................................................................................6 4. PRELIMINARY TEST ....................................................................................................................................................... 6 4.1 AC POWER LINE CONDUCTED EMISSIONS TESTS.......................................................................................................... 6 4.2 RADIATED EMISSIONS TESTS.......................................................................................................................................... 6 5. FINAL RESULT OF MEASURMENT ............................................................................................................................. 7 5.1 RADIATED EMISSION TEST............................................................................................................................................. 7 6. FIELD STRENGTH CALCULATION ............................................................................................................................. 8 7. LIST OF TEST EQUIPMENT........................................................................................................................................... 9 FCC ID. : NYOSEKS-TF10ARX Page 3 of 9 Report No.: E101R-029 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) 1. VERIFICATION OF COMPLIANCE APPLICANT : Shinchang Electrics Co., Ltd. ADDRESS : 734-2, Wo…
Text truncated - open the document above for the full version.
FCC ID. : NYOSEKS-TF10ARX Page 1 of 1 Report No.: E101R-029 This report shall not be reproduced except in full without our written approval. EMC-003 (Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289 FAX: 82-31-766-2904) Radiated Emission Test
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 315 MHz - 315 MHz | - |
UNIT ASSY-WIRELESS CHARGING
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzUNIT ASSY-WIRELESS CHARGING
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterUNIT ASSY-WIRELESS CHARGING
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterRemote Keyless Entry Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Rear Occupant Alert
Equipment Class
FDS - Part 15 Field Disturbance Sensor