
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
HEART RATE MONITOR
Neutron Engineering Inc. Project No.: 1002C107 Page 2 of 6 1002C107 1002C107 Neutron Engineering Inc. Project No.: 1002C107 Page 2 of 6 1002C107 1002C107
Neutron Engineering Inc. 1002C107 Project No.: 1002C107 Page 3 of 6 1002C107 Neutron Engineering Inc. 1002C107 Project No.: 1002C107 Page 4 of 6 1002C107 Neutron Engineering Inc. 1002C107 Project No.: 1002C107 Page 5 of 6 1002C107 Neutron Engineering Inc. 1002C107
Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 2 of 36 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutronshall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 3 of 36 Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 10 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 3.4 DESCRIPTION OF SUPPORT UNITS 12 4 . EMC EMISSION TEST 13 4.1 CONDUCTED EMISSION MEASUREMENT 13 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 4.1.2 MEASUREMENT INSTRUMENTS LIST 13 4.1.3 TEST PROCEDURE 14 4.1.4 DEVIATION FROM TEST STANDARD 14 4.1.5 TEST SETUP 14 4.1.6 EUT OPERATING CONDITIONS 14 4.1.7 TEST RESULTS 15 4.2 RADIATED EMISSION MEASUREMENT 16 4.2.1 RADIATED EMISSION LIMITS 16 4.2.2 MEASUREMENT INSTRUMENTS LIST 17 4.2.3 TEST PROCEDURE 20 4.2.4 DEVIATION FROM TEST STANDARD 20 4.2.5 TEST SETUP 21 4.2.6 EUT OPERATING CONDITIONS 22 4.2.7 TEST RESULTS (BETWEEN 30 – 1000 MHz) 23 4.2.8 TEST RESULTS (ABOVE 1000 MHz) 25 5 . BANDWIDTH TEST 29 5.1 MEASUREMENT INSTRUMENTS LIST 29 5.2 TEST PROCEDURE 29 5.3 DEVIATION FROM STANDARD 29 5.4 TEST SETUP 29 5.5 EUT OPERATION CONDITIONS 29 5.6 TEST RESULTS 30 6 . ANTENNA CONDUCTED SPURIOUS EMISSION 31 Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 4 of 36 Table of Contents Page 6.1 APPLIED PROCEDURES / LIMIT 31 6.1.1 MEASUREMENT INSTRUMENTS LIST 31 6.1.2 TEST PROCEDURE 31 6.1.3 DEVIATION FROM STANDARD 31 6.1.4 TEST SETUP 31 6.1.5 EUT OPERATION CONDITIONS 32 6.1.6 TEST RESULTS 33 7 . EUT TEST PHOTO 35 Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 5 of 36 1. CERTIFICATION E q u i p m e n t : Heart rate monitor Trade Name : N/A Model Name. : HRM1G A p p l i c a n t : Dayton Industrial Co. Ltd. Date of Test : Feb. 23, 2010~ Mar. 01, 2010 T e s t I t e m : ENGINEERING SAMPLE Standards : FCC Part15, Subpart C(15.249)/ ANSI C63.4 : 2003; Canada RSS-210:2007 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FICP-1-1002C107) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 6 of 36 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15, Subpart C (15.249) Canada RSS-210:2007 Canada FCC Test Item Judgment Remark 15.207 Conducted Emission - N/A A2.9(a) 15.209 Radiated emission PASS A2.9(a) 15.249 Radiated Spurious EmissionPASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 7 of 36 2.1 TEST FACILITY The test facilities used to collect the test data in this report is C01/OS02 at the location of No.132-1, Lane 329, Sec. 2, Palian Road, Shijr City, Taipei, Taiwan. Neutron's test firm number for FCC 95335 Neutron's test firm number for IC 4428A-1 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 A. Conducted Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE C01 ANSI150 KHz ~ 30MHz 1.94 B. Radiated Measurement : Test Site Method Measurement Frequency Range Ant. H / V U,(dB) NOTE OS-01 ANSI30MHz ~ 200MHz V 3.82 30MHz ~ 200MHz H 3.60 200MHz ~ 1,000MHz V 3.86 200MHz ~ 1,000MHz H 3.94 OS-02 ANSI30MHz ~ 200MHz V 2.48 30MHz ~ 200MHz H 2.16 200MHz ~ 1,000MHz V 2.50 200MHz ~ 1,000MHz H 2.66 Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 8 of 36 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Equipment Heart rate monitor Trade Name N/A Model Name. HRM1G OEM Brand/Model Name N/A Model Difference N/A Product Description The EUT is a Heart rate monitor. Product Type Low Power Communication Device Operation Frequency: 2457 MHz Modulation Type: GFSK Number Of Channel 1CH Antenna Designation: Printed antenna Antenna Gain(Peak) 1.80 dBi Output Power: 42.30 dBuV/m (AV Max.) Based on the application, features, or specification exhibited in User's Manual, the EUT is considered as an ITE/Computing Device. More details of EUT technical spe…
Text truncated - open the document above for the full version.
Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 35 of 36 7. EUT TEST PHOTO Radiated Measurement Photos TX Mode - Radiated emissions below 30MHz (Plot 1) TX Mode - Radiated emissions below 1000MHz (Plot 2) Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 35 of 36 7. EUT TEST PHOTO Radiated Measurement Photos TX Mode - Radiated emissions below 30MHz (Plot 1) TX Mode - Radiated emissions below 1000MHz (Plot 2) Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 36 of 36 Radiated Measurement Photos TX Mode - Radiated emissions Above 1000MHz (Plot 3)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.46 GHz - 2.46 GHz | - |
RS HMI Control
Equipment Class
DTS - Digital Transmission System
LINK2CARE
Equipment Class
DTS - Digital Transmission System
E-Bike HMI with BLE and ANT+
Equipment Class
DTS - Digital Transmission System
SMART BIKE SENSOR with Bluetooth and ANT+ function.
Equipment Class
DTS - Digital Transmission System
E-Bike controller with BLE and ANT+ function
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter