O4GHRM1GFabric Heart rate monitor

Dayton Industrial Co., Ltd.
Fabric Heart rate monitor - FCC ID O4GHRM1G - Dayton Industrial Co., Ltd.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Mar 15, 2010
Application Purpose
Original Equipment
Date of Application
Mar 15, 2010
Equipment Note
Fabric Heart rate monitor
Frequency Range
2457.00000000 - 2457.00000000
Company
Dayton Industrial Co., Ltd.
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

HEART RATE MONITOR

External Photos

Neutron Engineering Inc. Project No.: 1002C107 Page 2 of 6 1002C107 1002C107 Neutron Engineering Inc. Project No.: 1002C107 Page 2 of 6 1002C107 1002C107

Internal Photos

Neutron Engineering Inc. 1002C107 Project No.: 1002C107 Page 3 of 6 1002C107 Neutron Engineering Inc. 1002C107 Project No.: 1002C107 Page 4 of 6 1002C107 Neutron Engineering Inc. 1002C107 Project No.: 1002C107 Page 5 of 6 1002C107 Neutron Engineering Inc. 1002C107

Test Report

Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 2 of 36 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutronshall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 3 of 36 Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 10 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 3.4 DESCRIPTION OF SUPPORT UNITS 12 4 . EMC EMISSION TEST 13 4.1 CONDUCTED EMISSION MEASUREMENT 13 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 4.1.2 MEASUREMENT INSTRUMENTS LIST 13 4.1.3 TEST PROCEDURE 14 4.1.4 DEVIATION FROM TEST STANDARD 14 4.1.5 TEST SETUP 14 4.1.6 EUT OPERATING CONDITIONS 14 4.1.7 TEST RESULTS 15 4.2 RADIATED EMISSION MEASUREMENT 16 4.2.1 RADIATED EMISSION LIMITS 16 4.2.2 MEASUREMENT INSTRUMENTS LIST 17 4.2.3 TEST PROCEDURE 20 4.2.4 DEVIATION FROM TEST STANDARD 20 4.2.5 TEST SETUP 21 4.2.6 EUT OPERATING CONDITIONS 22 4.2.7 TEST RESULTS (BETWEEN 30 – 1000 MHz) 23 4.2.8 TEST RESULTS (ABOVE 1000 MHz) 25 5 . BANDWIDTH TEST 29 5.1 MEASUREMENT INSTRUMENTS LIST 29 5.2 TEST PROCEDURE 29 5.3 DEVIATION FROM STANDARD 29 5.4 TEST SETUP 29 5.5 EUT OPERATION CONDITIONS 29 5.6 TEST RESULTS 30 6 . ANTENNA CONDUCTED SPURIOUS EMISSION 31 Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 4 of 36 Table of Contents Page 6.1 APPLIED PROCEDURES / LIMIT 31 6.1.1 MEASUREMENT INSTRUMENTS LIST 31 6.1.2 TEST PROCEDURE 31 6.1.3 DEVIATION FROM STANDARD 31 6.1.4 TEST SETUP 31 6.1.5 EUT OPERATION CONDITIONS 32 6.1.6 TEST RESULTS 33 7 . EUT TEST PHOTO 35 Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 5 of 36 1. CERTIFICATION E q u i p m e n t : Heart rate monitor Trade Name : N/A Model Name. : HRM1G A p p l i c a n t : Dayton Industrial Co. Ltd. Date of Test : Feb. 23, 2010~ Mar. 01, 2010 T e s t I t e m : ENGINEERING SAMPLE Standards : FCC Part15, Subpart C(15.249)/ ANSI C63.4 : 2003; Canada RSS-210:2007 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FICP-1-1002C107) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 6 of 36 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15, Subpart C (15.249) Canada RSS-210:2007 Canada FCC Test Item Judgment Remark 15.207 Conducted Emission - N/A A2.9(a) 15.209 Radiated emission PASS A2.9(a) 15.249 Radiated Spurious EmissionPASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 7 of 36 2.1 TEST FACILITY The test facilities used to collect the test data in this report is C01/OS02 at the location of No.132-1, Lane 329, Sec. 2, Palian Road, Shijr City, Taipei, Taiwan. Neutron's test firm number for FCC 95335 Neutron's test firm number for IC 4428A-1 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 A. Conducted Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE C01 ANSI150 KHz ~ 30MHz 1.94 B. Radiated Measurement : Test Site Method Measurement Frequency Range Ant. H / V U,(dB) NOTE OS-01 ANSI30MHz ~ 200MHz V 3.82 30MHz ~ 200MHz H 3.60 200MHz ~ 1,000MHz V 3.86 200MHz ~ 1,000MHz H 3.94 OS-02 ANSI30MHz ~ 200MHz V 2.48 30MHz ~ 200MHz H 2.16 200MHz ~ 1,000MHz V 2.50 200MHz ~ 1,000MHz H 2.66 Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 8 of 36 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Equipment Heart rate monitor Trade Name N/A Model Name. HRM1G OEM Brand/Model Name N/A Model Difference N/A Product Description The EUT is a Heart rate monitor. Product Type Low Power Communication Device Operation Frequency: 2457 MHz Modulation Type: GFSK Number Of Channel 1CH Antenna Designation: Printed antenna Antenna Gain(Peak) 1.80 dBi Output Power: 42.30 dBuV/m (AV Max.) Based on the application, features, or specification exhibited in User's Manual, the EUT is considered as an ITE/Computing Device. More details of EUT technical spe…

Text truncated - open the document above for the full version.

Test Setup Photos

Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 35 of 36 7. EUT TEST PHOTO Radiated Measurement Photos TX Mode - Radiated emissions below 30MHz (Plot 1) TX Mode - Radiated emissions below 1000MHz (Plot 2) Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 35 of 36 7. EUT TEST PHOTO Radiated Measurement Photos TX Mode - Radiated emissions below 30MHz (Plot 1) TX Mode - Radiated emissions below 1000MHz (Plot 2) Neutron Engineering Inc. Report No.: NEI-FICP-1-1002C107 Page 36 of 36 Radiated Measurement Photos TX Mode - Radiated emissions Above 1000MHz (Plot 3)

Contact Information

Applicant

Wong Lap Fai(Project Manager)
[email protected]+852 2422 4404Fax: +852 2480 4627

Test Firm

BTL Inc.Andy Yeh
[email protected]+886-2-2641-8198Fax: +886-2-2641-8698

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.46 GHz - 2.46 GHz-
Confidentiality
Long Term

Other Applications from Dayton Industrial Co., Ltd.

O4G387

RS HMI Control

May 19, 2026

Equipment Class

DTS - Digital Transmission System
LINK2CARE - FCC ID O4GHRM25 - Dayton Industrial Co., Ltd.
O4GHRM25

LINK2CARE

Feb 10, 2026

Equipment Class

DTS - Digital Transmission System
E-Bike HMI with BLE and ANT+ - FCC ID O4GT3 - Dayton Industrial Co., Ltd.
O4GT3

E-Bike HMI with BLE and ANT+

Dec 16, 2023

Equipment Class

DTS - Digital Transmission System
SMART BIKE SENSOR with Bluetooth and ANT+ function. - FCC ID O4GTPMS - Dayton Industrial Co., Ltd.
O4GTPMS

SMART BIKE SENSOR with Bluetooth and ANT+ function.

Jul 18, 2022

Equipment Class

DTS - Digital Transmission System
E-Bike controller with BLE and ANT+ function - FCC ID O4GTCU2 - Dayton Industrial Co., Ltd.
O4GTCU2

E-Bike controller with BLE and ANT+ function

Dec 28, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter