FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Dayton Industrial Co., Ltd./
  3. O4GIPDWAP2

O4GIPDWAP2information Technology Equipment

Dayton Industrial Co., Ltd.
information Technology Equipment - FCC ID O4GIPDWAP2 - Dayton Industrial Co., Ltd.
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Apr 18, 2011
Application Purpose
Original Equipment
Date of Application
Apr 18, 2011
Equipment Note
information Technology Equipment
Frequency Range
2450.00000000 - 2466.00000000
Company
Dayton Industrial Co., Ltd.
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

fisica Sensor Case Warnings Before beginning or modifying any exercise program, please consult your physician. If you have a pacemaker or other implanted electronic device, consult your physician before using a heart rate sensor. This product is intended for recreational use only and is not intended for medical purposes. Heart rate and other readings could be influenced by interference from external sources. If you use this product with navigation software, always be aware of your surround- ings and do not fixate on the screen. Moreover, set destinations and other user inputs prior to your departure to ensure your attention stays on task and your facilities are directed to your activity and not the device. This device contains no user user-serviceable parts and repairs/modifications should only be made by a technician authorized by Wahoo Fitness. Any unauthorized modifications or repairs will void your warranty. Do not leave device exposed to excessive heat or cold. California Proposition 65 The enclosed hardware and its packaging contain chemicals the State of California has found to cause cancer, birth defects or reproductive harm. FCC Rules Part 15 The enclosed hardware device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) it must accept any interference received, including interfer- ence that may cause undesired operation. Limited Warranty Wahoo Fitness warrants this product to be free from defects in material and workmanship, under normal use, for one year from the date of original purchase. Defects that have resulted from improper or unreasonable use or maintenance, accident, excess moisture, insects, improper packing, lightning, power surges, or unauthorized tampering, alteration or modification are not covered. Wahoo Fitness will, at its discretion, repair or replace with a comparable product, at no charge to the customer for parts or labor, so long as customer is responsible for shipping costs. Products may be new, refurbished or reconditioned and are warranted for the unexpired period of the original purchase, or 60 days from return, whichever is greater. Any products replaced become the property of Wahoo Fitness. WHERE PERMITTED, THE PROVISIONS OF THIS LIMITED WARRANTY ARE IN LIEU OF ANY OTHER WRITTEN WARRANTY, WHETHER EXPRESS OR IMPLIED, WRITTEN OR ORAL, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL WAHOO FITNESS BE LIABLE FOR SPECIAL, INCIDENTAL, CONSE- QUENTIAL OR INDIRECT DAMAGES. SOME PLACES DO NOT ALLOW LIMITATIONS ON THE EXCLUSION OR LIMITATION OF LIABILITY TO SPECIFIED AMOUNTS, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. To obtain warranty service, contact Wahoo Fitness for shipping instructions and an RMA tracking number. Return your device, freight prepaid, along with the original sales receipt which is a required proof of purchase for warranty repairs, with the RMA tracking number written on the outside of the package, and mail to Wahoo Fitness. Legal Compatible With “Made for iPhone” means that an electronic accessory has been designed to connect specifically to iPhone and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPhone may affect wireless performance. iPhone is a trademark of Apple Inc., registered in the U.S. and other countries. fisica Download Wahoo Fitness Utility App from iTunes. Insert fisicasecurely into 30-pin connector at bottem of iPhone, iPod touch or iPad. Open Wahoo Fitness Utility and select Sensor tab. Select sensor you would like to pair with iPhone, iPod touch or iPad. Ensure the sensor is within 5’ of fisica. Done! Your sensor should show data from the sensor, the signal strength and the serial number of your sensor. Since ANT+ sensors ‘sleep’ when not in use, you may have to ‘awaken’ it - for example, a footpod can be activated by taking a few steps. Other Apps Each App has a unique way in which it works with sensors so there is no universal method for usingfisicawith all Apps. One common feature is that each App can be ‘paired’ with a particular sensor to avoid readings from other people’s sensors. Check our website for the current list of Apps compatible with yourfisicasensor key. 3rd Party Sensors fisicawill work with all wireless sensors that conform to the ANT+ standard. However, third party sensors have not been tested or verified by Wahoo Fitness and the accuracy of the data produced may not be as precise as those of Wahoo Fitness sensors Contact Wahoo Fitness Please feel free to contact Wahoo Fitness for any questions you have regarding your product. Wahoo Fitness L.L.C. 1604 athens Hwy Gainesville, Georgia, USA 30507 (404) 939-2447 www.wahoofi AP201 tness.com I n s t r u c t i o n s fisica Warnings Before beginning or modifying any ex ercise program, please consult your physician. If you have a pacemaker or other implanted electronic device, consult your physician before using a heart rate monitor. This product is intended for recreational use only and is not intended for medical purposes. Heart rate and other readings could be influenced by interference from external sources. If you use this product with navigation software, always be aware of your surround- ings and do not fixate on the screen. Morover, set destinations and other user inputs prior to your departure to ensure your attention and facilities are directed on your activity and not the device. This device contains no user user-serviceable parts and repairs/modifications should only be made by a technician authorized by Wahoo Fitness. Any unauthorized modifications or repairs will void your warranty. Do not leave device exposed to excessive heat or cold. California Proposition 65 The enclosed hardware and its packa…

Text truncated - open the document above for the full version.

External Photos

Neutron Engineering Inc. Project No.: 1101C099 Page 2 of 6 1101C099 1101C099 Neutron Engineering Inc. Project No.: 1101C099 Page 2 of 6 1101C099 1101C099

Internal Photos

Neutron Engineering Inc. Project No.: 1101C099 Page 3 of 6 1101C099 1101C099 Neutron Engineering Inc. Project No.: 1101C099 Page 3 of 6 1101C099 1101C099 Neutron Engineering Inc. Project No.: 1101C099 Page 4 of 6 1101C099 1101C099 Neutron Engineering Inc. Project No.: 1101C099 Page 4 of 6 1101C099 1101C099 Neutron Engineering Inc. Project No.: 1101C099 Page 5 of 6 1101C099 1101C099 Neutron Engineering Inc. Project No.: 1101C099 Page 5 of 6 1101C099 1101C099 Neutron Engineering Inc. Project No.: 1101C099 Page 6 of 6 1101C099 1101C099 Neutron Engineering Inc. Project No.: 1101C099 Page 6 of 6 1101C099 1101C099

Test Report

Neutron Engineering Inc. Report No.: NEI-FICP-1-1101C099 Page 2 of 49 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FICP-1-1101C099 Page 3 of 49 Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 9 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 3.4 DESCRIPTION OF SUPPORT UNITS 11 4 . EMC EMISSION TEST 12 4.1 CONDUCTED EMISSION MEASUREMENT 12 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 12 4.1.2 MEASUREMENT INSTRUMENTS LIST 12 4.1.3 TEST PROCEDURE 13 4.1.4 DEVIATION FROM TEST STANDARD 13 4.1.5 TEST SETUP 13 4.1.6 EUT OPERATING CONDITIONS 13 4.1.7 TEST RESULTS 14 4.2 RADIATED EMISSION MEASUREMENT 15 4.2.1 RADIATED EMISSION LIMITS 15 4.2.2 MEASUREMENT INSTRUMENTS LIST 16 4.2.3 TEST PROCEDURE 19 4.2.4 DEVIATION FROM TEST STANDARD 19 4.2.5 TEST SETUP 20 4.2.6 EUT OPERATING CONDITIONS 20 4.2.7 TEST RESULTS (BETWEEN 30 – 1000 MHz) 21 4.2.8 TEST RESULTS (ABOVE 1000 MHz) 25 4.2.9 TEST RESULTS (2400 – 2483.5 MHz) 39 5 . BANDWIDTH TEST 40 5.1 MEASUREMENT INSTRUMENTS LIST 40 5.2 TEST PROCEDURE 40 5.3 DEVIATION FROM STANDARD 40 5.4 TEST SETUP 40 5.5 EUT OPERATION CONDITIONS 40 5.6 TEST RESULTS 41 6 . ANTENNA CONDUCTED SPURIOUS EMISSION 43 Neutron Engineering Inc. Report No.: NEI-FICP-1-1101C099 Page 4 of 49 Table of Contents Page 6.1 APPLIED PROCEDURES / LIMIT 43 6.1.1 MEASUREMENT INSTRUMENTS LIST 43 6.1.2 TEST PROCEDURE 43 6.1.3 DEVIATION FROM STANDARD 43 6.1.4 TEST SETUP 43 6.1.5 EUT OPERATION CONDITIONS 43 6.1.6 TEST RESULTS 44 7 . EUT TEST PHOTO 49 Neutron Engineering Inc. Report No.: NEI-FICP-1-1101C099 Page 5 of 49 1. CERTIFICATION E q u i p m e n t : Information Technology Equipment Brand Name : N/A Model Name. : AP201 A p p l i c a n t : Dayton Industrial Co. Ltd. Date of Test : Jan. 06, 2011 ~ Mar. 07, 2011 T e s t I t e m : ENGINEERING SAMPLE Standards : FCC Part15, Subpart C(15.249)/ ANSI C63.4 : 2003 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FICP-1-1101C099) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). Neutron Engineering Inc. Report No.: NEI-FICP-1-1101C099 Page 6 of 49 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15, Subpart C (15.249) Canada RSS-210:2010 StandardSection FCC RSS-210 Test Item Judgment Remark 15.207 Conducted Emission - Note(1) 15.209 Radiated Emission PASS 15.249 A2.9(a) Radiated Spurious Emission PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Neutron Engineering Inc. Report No.: NEI-FICP-1-1101C099 Page 7 of 49 2.1 TEST FACILITY The test facilities used to collect the test data in this report is DG-C02/DG-CB03at the location of No.3,Jinshagang 1st Road, ShiXia, Dalang Town,Dong Guan, China.523792 Neutron's test firm number for FCC 319330 Neutron's test firm number for IC 4428B-1 2.2 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2: The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 A. Conducted Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE DG-C02 CISPR 150 KHz ~ 30MHz 1.94 B. Radiated Measurement : Test Site Method Measurement Frequency Range Ant. H / V U,(dB) NOTE 30MHz ~ 200MHz V 2.48 30MHz ~ 200MHz H 2.16 200MHz ~ 1,000MHz V 2.50 DG-CB03 CISPR 200MHz ~ 1,000MHz H 2.66 Neutron Engineering Inc. Report No.: NEI-FICP-1-1101C099 Page 8 of 49 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Equipment Information Technology Equipment Brand Name N/A Model Name. AP201 OEM Brand/Model Name N/A Model Difference N/A Product Description The EUT is a Information Technology Equipment . Product Type Low Power Communication Device Operation Frequency: 2450~2466 MHz Modulation Type: GFSK Date rate: 1Mbps Number Of Channel 3CH .Please see note 2. Antenna Designation: Chip antenna Antenna Gain(Peak) 2.0 dBi Output Power: 40.17dBuV/m (AV …

Text truncated - open the document above for the full version.

Test Setup Photos

Neutron Engineering Inc. Report No.: NEI-FICP-1-1101C099 Page 49 of 49 7. EUT TEST PHOTO Radiated Measurement Photos Neutron Engineering Inc. Report No.: NEI-FICP-1-1101C099 Page 49 of 49 7. EUT TEST PHOTO Radiated Measurement Photos

Contact Information

Applicant

Wong Lap Fai(Project Manager)
[email protected]+852 2422 4404Fax: +852 2480 4627

Technical Contact

Neutron Engineering Inc.Cathy Wang
[email protected]+886-769-83183000

No.3,Jinshagang 1st Rd, ShiXia,Dalang Town · Dongguan · China

Non-Technical Contact

Neutron Engineering Inc.Cathy Wang
[email protected]+886-769-83183000

Test Firm

BTL Inc.Daisy Dai
[email protected]008676983183000Fax: 0086 769 83196000

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.45 GHz - 2.47 GHz-
Confidentiality
Long Term

Other Applications from Dayton Industrial Co., Ltd.

O4G387

RS HMI Control

May 19, 2026

Equipment Class

DTS - Digital Transmission System
LINK2CARE - FCC ID O4GHRM25 - Dayton Industrial Co., Ltd.
O4GHRM25

LINK2CARE

Feb 10, 2026

Equipment Class

DTS - Digital Transmission System
E-Bike HMI with BLE and ANT+ - FCC ID O4GT3 - Dayton Industrial Co., Ltd.
O4GT3

E-Bike HMI with BLE and ANT+

Dec 16, 2023

Equipment Class

DTS - Digital Transmission System
SMART BIKE SENSOR with Bluetooth and ANT+ function. - FCC ID O4GTPMS - Dayton Industrial Co., Ltd.
O4GTPMS

SMART BIKE SENSOR with Bluetooth and ANT+ function.

Jul 18, 2022

Equipment Class

DTS - Digital Transmission System
E-Bike controller with BLE and ANT+ function - FCC ID O4GTCU2 - Dayton Industrial Co., Ltd.
O4GTCU2

E-Bike controller with BLE and ANT+ function

Dec 28, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter