FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Dayton Industrial Co., Ltd./
  3. O4GJOULE2

O4GJOULE2GPS Bike Computer

Dayton Industrial Co., Ltd.
GPS Bike Computer - FCC ID O4GJOULE2 - Dayton Industrial Co., Ltd.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Nov 09, 2011
Application Purpose
Original Equipment
Date of Application
Nov 09, 2011
Equipment Note
GPS Bike Computer
Frequency Range
2457.00000000 - 2457.00000000
Company
Dayton Industrial Co., Ltd.
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Joule GPS Quickstart Guide | Guía de usuario | Mode d’emploi | Benutzerhandbuch | Manuale dell’utente | Gebruikershandleiding | DRAFT/ 11 09 11-B /JOULE gps/QUICKSTART INSTALLATIONINTRODUCTION INT HANDLEBAR MOUNT INT O-Rings: Crisscross under stem, latch on hooks OR Zip tie around stem, through slots STEM MOUNT INT INT Lorem ipsum dolor sit amet, consectetur adipiscing elit. Aliquam mattis, dui sit amet mattis dapibus, massa justo aliquet lorem, lobortis accumsan libero tortor eget orci. Duis eleifend pellentesque massa, sit amet rutrum urna luctus a. Integer varius urna vel mi posuere porttitor. Praesent semper blandit turpis, eget elementum enim dictum id. Donec rhoncus gravida enim, ultricies pharetra mi lacinia vel. Morbi mattis magna ac augue eleifend viverra. Quisque porttitor fermentum vulputate. Duis ac ante a erat cursus rhoncus in ac m INT HR 121--- ------ 17.2 1:06:45 CAD BALANCE5 SEC 110145 AV HRMAX HR KPHRIDE TIME 9:34A71º Highlight in Dashboard, ...see detail at bottom USB Port Time Temperature Heading Battery Level NAVIGATION OVERVIEW [ENTER] button * Press once to move through Dashboards * Hold for 3 seconds - Go to Menu * Hold for 3 seconds in Menus - Go to Dashboard Shifts “highlight box” to the right and down Shifts “highlight box” to the left and up Press to mark intervals [PLUS] button [MINUS] button [INTERVAL] button BUTTONSFUNCTION DASHBOARDS 1,2 & 3 DRAFT/ 11 09 11-B /JOULE gps/QUICKSTART Each Dashboard displaysorem ipsum dolor sit amet, consectetur adipiscing elit. Aliquam mattis, dui sit amet mattis dapibus, massa DASHBOARD 1DASHBOARD 2DASHBOARD 3 WATTS 4515% 2196 17.2 1:06:45 PWR ZONE MPHCAD 170894 AV WATTSMX WATTS AV PWR ZONEHR ZONE OTHERRIDE TIME 1:06:45 RIDE TIME 9:34A71º Zones Additional Detail A A B B AV MPHMX MPH C AV CADMX CAD D OTHEROTHER E MILESKJ F CD EF WATTS --- 2196 380 MPHCAD 170894 AV WATTSMX WATTS KJ 9:34A71º A A B B AV CADMX CAD C Countdown OFF D KJ/HRTSS E C D E 1:06:45 RIDE TIME --- 89 689 WATTS OFF Countdown AV WATTSMX WATTS HR5 SEC 9:34A71º A A B B AV HRMX HR C 5 MIN20 MIN D CD AV MPHMX MPH Press • [ENTER] to advance through Dashboards INT [ENTER] DRAFT/ 11 09 11-B /JOULE gps/QUICKSTART Each Dashboard displaysorem ipsum dolor sit amet, consectetur adipiscing elit. Aliquam mattis, dui sit amet mattis dapibus, massa DASHBOARD 4 (INTERVALS) DASHBOARD 5 (GPS MAP) DASHBOARDS 4 & 5 ie: callout ie: callout ie: callout ie: callout ie: callout ie: callout ie: callout ie: callout Press • [ENTER] to advance through Dashboards INT [ENTER] INTERVALS Intervals are useful for viewing ride data specic to a section of your ride, such as a ball or other period of high intensity riding. [INTERVAL] INT INT Press & Hold 3 sec. to go to Interval Mode [INTERVAL] Press & Hold 3 sec. to go back to Ride Mode back -> RIDE MODEINTERVAL MODE Displays data for current interval Add copy.... ENTIRE RIDE Add copy... INTERVAL 2 INTERVAL 1 UP TO 99 INTERVALS 11:31 A 2 11:31 INT A NOTE: THIS INTERVAL ART FROM JOULE 1 - CONVERTING TO JOULE GPS NOW NOTE: THESE TWO ARE SCREEN CAPTURES - CONVERTING NOW DRAFT/ 11 09 11-B /JOULE gps/QUICKSTART MENU Enter Menu to review ride history, pair sensors, use the workout function, and congure the device. PAIRING text here DOWNLOAD Install PowerAgent software from www.cycleops.com/poweragent to download ride data INT MicroUSB USB GO FOR A RIDE RIDE PAUSE SAVE LAST RIDE LAST 1 WK LAST 2 WK LAST 4 WK BIKE1: FIND BIKE1: PAIR BIKE1: ZERO WO: DISTANCE WO: TIMER DEV: TRIP DEV: ALTI DEV: CLOCK BACK->DASH DEV: UNITS DEV: LANGUAGE BACK->MENU BIKE1: WHEEL BACK->MENU WO: KJ BACK->MENU ALL RIDES PICK RIDE BACK->MENU CLEAR BACK->MENU HISTORY NOTE: PAIRING TREE WILL GO HERE SENSOR WORKOUT DEVICE BACK TO DASHBOARD Press • [ENTER] to advance through Dashboards NOTE: THIS TABLE FROM JOULE 1 - EDITING NOW TO JOULE GPS NOTE: THIS IS A SCREEN CAPTURE, RENDERING NOW RIDE AND DOWNLOAD TO BE PLACED ALONG BOTTOM Model: Joule 2.0 FCC statement NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CASUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER AUTHORITY TO OPERATE THE EQUIPMENT. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Pa rt 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and , if not installed and used in accordance with the instructions, may cause harmful interference to radio commu nications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or mor e the following measures:  Reorient or relocate the receiving antenna  Increase the separation between the equipment and receiver  Connect the equipment into an outlet on a circuit different from that to which the receiver is corrected  Consult the dealer or experience radio / TV technician for help Canada Statement IC: 7666A‐JOULE2 This Device complies with RSS‐210 of IC Rules; Operation is subject to the following two conditions: (1) This device may not cause interference and (2) This device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. This device meets the ex emption from the routine evaluation limits in section 2.5 of RSS 102 and u…

Text truncated - open the document above for the full version.

External Photos

Neutron Engineering Inc. Project No.: 1110C174 Page 2 of 8 1110C174 1110C174 Neutron Engineering Inc. Project No.: 1110C174 Page 2 of 8 1110C174 1110C174

Internal Photos

Neutron Engineering Inc. Project No.: 1110C174 Page 3 of 8 1110C174 1110C174 Neutron Engineering Inc. Project No.: 1110C174 Page 3 of 8 1110C174 1110C174 Neutron Engineering Inc. Project No.: 1110C174 Page 4 of 8 1110C174 1110C174 Neutron Engineering Inc. Project No.: 1110C174 Page 4 of 8 1110C174 1110C174 Neutron Engineering Inc. Project No.: 1110C174 Page 5 of 8 1110C174 1110C174 Neutron Engineering Inc. Project No.: 1110C174 Page 5 of 8 1110C174 1110C174 Neutron Engineering Inc. Project No.: 1110C174 Page 6 of 8 1110C174 1110C174 Neutron Engineering Inc. Project No.: 1110C174 Page 6 of 8 1110C174 1110C174 Neutron Engineering Inc. Project No.: 1110C174 Page 7 of 8 1110C174 1110C174 Neutron Engineering Inc. Project No.: 1110C174 Page 7 of 8 1110C174 1110C174 Neutron Engineering Inc. Project No.: 1110C174 Page 8 of 8 1110C174 1110C174 Neutron Engineering Inc. Project No.: 1110C174 Page 8 of 8 1110C174 1110C174

Test Report

Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 1 of 48 FCC/IC Radio Test Report FCC ID: O4GJOULE2 IC: 7666A-JOULE2 This report concerns (check one): Original Grant Class II Change Issued Date : Nov. 01, 2011 Project No. : 1110C174 Equipment : GPS Bike Computer Model Name : JOULE 2.0 Applicant : Dayton Industrial Co. Ltd. Address : 2-12 Kwai Fat Road, 11- A Kwai Chung,New Territories, Hong Kong Manufacturer : Kendy Electronics (Dongguan) Co. Ltd. Address : Xingsi Huangtang Village, Hengli Town, Dongguan City, Guangdong Province, P.R. China Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: Oct. 24, 2011 Date of Test: Oct. 24, 2011 ~ Oct. 31, 2011 Testing Engineer : (Ivan Cao) Technical Manager : (Leo Hung) Authorized Signatory : (Steven Lu) Neutron Engineering Inc. No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL : (0769) 8318-3000 FAX : (0769) 8319-6000 Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 2 of 48 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 3 of 48 Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 9 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 3.4 DESCRIPTION OF SUPPORT UNITS 11 4 . EMC EMISSION TEST 12 4.1 CONDUCTED EMISSION MEASUREMENT 12 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 12 4.1.2 MEASUREMENT INSTRUMENTS LIST 12 4.1.3 TEST PROCEDURE 13 4.1.4 DEVIATION FROM TEST STANDARD 13 4.1.5 TEST SETUP 13 4.1.6 EUT OPERATING CONDITIONS 13 4.1.7 TEST RESULTS 14 4.2 RADIATED EMISSION MEASUREMENT 16 4.2.1 RADIATED EMISSION LIMITS 16 4.2.2 MEASUREMENT INSTRUMENTS LIST 17 4.2.3 TEST PROCEDURE 20 4.2.4 DEVIATION FROM TEST STANDARD 20 4.2.5 TEST SETUP 21 4.2.6 EUT OPERATING CONDITIONS 22 4.2.7 TEST RESULTS (BETWEEN 30 – 1000 MHz) 24 4.2.8 TEST RESULTS (ABOVE 1000 MHz) 30 4.2.9 TEST RESULTS (2400 – 2483.5 MHz) 38 5 . BANDWIDTH TEST 39 5.1 MEASUREMENT INSTRUMENTS LIST 39 5.2 TEST PROCEDURE 39 5.3 DEVIATION FROM STANDARD 39 5.4 TEST SETUP 39 5.5 EUT OPERATION CONDITIONS 39 5.6 TEST RESULTS 40 6 . ANTENNA CONDUCTED SPURIOUS EMISSION 41 Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 4 of 48 Table of Contents Page 6.1 APPLIED PROCEDURES / LIMIT 41 6.1.1 MEASUREMENT INSTRUMENTS LIST 41 6.1.2 TEST PROCEDURE 41 6.1.3 DEVIATION FROM STANDARD 41 6.1.4 TEST SETUP 41 6.1.5 EUT OPERATION CONDITIONS 41 6.1.6 TEST RESULTS 42 7 . EUT TEST PHOTO 45 Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 5 of 48 1. CERTIFICATION Equipment : GPS Bike Computer Brand Name : N/A Model Name. : JOULE 2.0 A p p l i c a n t : Dayton Industrial Co. Ltd. Date of Test : Oct. 24, 2011 ~ Oct. 31, 2011 T e s t I t e m : ENGINEERING SAMPLE Standards : FCC Part15, Subpart C(15.249)/ ANSI C63.4 : 2003; Canada RSS-210:2010 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FICP-1-1110C174) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 6 of 48 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15, Subpart C (15.249) Canada RSS-210:2010 StandardSection FCC RSS-210 Test Item Judgment Remark 15.207 Conducted Emission PASS 15.209 Radiated Emission PASS 15.249 A2.9(a) Radiated Spurious Emission PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 7 of 48 2.1 TEST FACILITY The test facilities used to collect the test data in this report is DG-C02/DG-CB03at the location of No.3,Jinshagang 1st Road, ShiXia, Dalang Town,Dong Guan, China.523792 Neutron's test firm number for FCC 319330 Neutron's test firm number for IC 4428B-1 2.2 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2: The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of conf…

Text truncated - open the document above for the full version.

Test Setup Photos

Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 45 of 48 7. EUT TEST PHOTO Conducted Measurement Photos Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 45 of 48 7. EUT TEST PHOTO Conducted Measurement Photos Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 46 of 48 Radiated Measurement Photos 9K~30MHz Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 46 of 48 Radiated Measurement Photos 9K~30MHz Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 47 of 48 Radiated Measurement Photos 30M~1000MHz Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 47 of 48 Radiated Measurement Photos 30M~1000MHz Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 48 of 48 Radiated Measurement Photos Above 1000MHz Neutron Engineering Inc. Report No.: NEI-FICP-1-1110C174 Page 48 of 48 Radiated Measurement Photos Above 1000MHz

Contact Information

Applicant

Wong Lap Fai(Project Manager)
[email protected]+852 2422 4404Fax: +852 2480 4627

Test Firm

BTL Inc.Daisy Dai
[email protected]008676983183000Fax: 0086 769 83196000

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.46 GHz - 2.46 GHz-
Confidentiality
Long Term

Other Applications from Dayton Industrial Co., Ltd.

O4G387

RS HMI Control

May 19, 2026

Equipment Class

DTS - Digital Transmission System
LINK2CARE - FCC ID O4GHRM25 - Dayton Industrial Co., Ltd.
O4GHRM25

LINK2CARE

Feb 10, 2026

Equipment Class

DTS - Digital Transmission System
E-Bike HMI with BLE and ANT+ - FCC ID O4GT3 - Dayton Industrial Co., Ltd.
O4GT3

E-Bike HMI with BLE and ANT+

Dec 16, 2023

Equipment Class

DTS - Digital Transmission System
SMART BIKE SENSOR with Bluetooth and ANT+ function. - FCC ID O4GTPMS - Dayton Industrial Co., Ltd.
O4GTPMS

SMART BIKE SENSOR with Bluetooth and ANT+ function.

Jul 18, 2022

Equipment Class

DTS - Digital Transmission System
E-Bike controller with BLE and ANT+ function - FCC ID O4GTCU2 - Dayton Industrial Co., Ltd.
O4GTCU2

E-Bike controller with BLE and ANT+ function

Dec 28, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter